1.SOX11-mediated CBLN2 Upregulation Contributes to Neuropathic Pain through NF-κB-Driven Neuroinflammation in Dorsal Root Ganglia of Mice.
Ling-Jie MA ; Tian WANG ; Ting XIE ; Lin-Peng ZHU ; Zuo-Hao YAO ; Meng-Na LI ; Bao-Tong YUAN ; Xiao-Bo WU ; Yong-Jing GAO ; Yi-Bin QIN
Neuroscience Bulletin 2025;41(12):2201-2217
Neuropathic pain, a debilitating condition caused by dysfunction of the somatosensory nervous system, remains difficult to treat due to limited understanding of its molecular mechanisms. Bioinformatics analysis identified cerebellin 2 (CBLN2) as highly enriched in human and murine proprioceptive and nociceptive neurons. We found that CBLN2 expression is persistently upregulated in dorsal root ganglia (DRG) following spinal nerve ligation (SNL) in mice. In addition, transcription factor SOX11 binds to 12 cis-regulatory elements within the Cbln2 promoter to enhance its transcription. SNL also induced SOX11 upregulation, with SOX11 and CBLN2 co-localized in nociceptive neurons. The siRNA-mediated knockdown of Sox11 or Cbln2 attenuated SNL-induced mechanical allodynia and thermal hyperalgesia. High-throughput sequencing of DRG following intrathecal injection of CBLN2 revealed widespread gene expression changes, including upregulation of numerous NF-κB downstream targets. Consistently, CBLN2 activated NF-κB signaling, and inhibition with pyrrolidine dithiocarbamate reduced CBLN2-induced pain hypersensitivity, proinflammatory cytokines and chemokines production, and neuronal hyperexcitability. Together, these findings identified the SOX11/CBLN2/NF-κB axis as a critical mediator of neuropathic pain and a promising target for therapeutic intervention.
Animals
;
Neuralgia/metabolism*
;
Ganglia, Spinal/metabolism*
;
Up-Regulation
;
Mice
;
NF-kappa B/metabolism*
;
SOXC Transcription Factors/genetics*
;
Male
;
Neuroinflammatory Diseases/metabolism*
;
Mice, Inbred C57BL
;
Nerve Tissue Proteins/genetics*
;
Hyperalgesia/metabolism*
;
Signal Transduction
;
Spinal Nerves
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Construction of a postoperative mortality risk model for patients with acute aortic dissection based on XGBoost-SHAP method
Xin ZHANG ; Min FANG ; Yi CAO ; Ting-Ting LI ; Xian-Kong LIU ; Jia-Yi DANG ; Xue-Sen ZHAO ; Hong-Qin REN ; Jia-Ze GENG ; Kai-Wen WANG ; Tie-Sheng HAN ; Yong-Bo ZHAO ; Dong MA
Medical Journal of Chinese People's Liberation Army 2025;50(10):1226-1234
Objective To develop a predictive model for postoperative mortality risk in patients with acute aortic dissection(AAD)using the Extreme Gradient Boosting(XGBoost)algorithm combined with Shapley Additive Explanation(SHAP),and to establish a prediction website to serve as a diagnostic and therapeutic support platform for clinicians and patients.Methods A retrospective cohort study design was adopted.Data from 782 AAD patients who underwent surgical treatment at the Fourth Hospital of Hebei Medical University from January 2013 to December 2023 were collected,including basic information and initial serum biomarker test results.Patients were randomly divided into training and test sets at a 7:3 ratio.An external validation set consisting of 313 AAD patients admitted to the Second Hospital of Hebei Medical University from January 2020 to December 2023 was also established for further model validation.Variables were screened using LASSO regression,and an XGBoost machine learning model was constructed and interpreted using SHAP.The predictive performance of the model was evaluated using receiver operating characteristic(ROC)curve analysis.Using the Shiny package,the XGBoost model was deployed to shinyapps.io to create a prediction website for postoperative mortality risk in AAD patients.One patient was selected by simple random sampling from the test set and the external validation set respectively for the prediction example on the Shiny webpage.Results The XGBoost model demonstrated high predictive performance for postoperative mortality in AAD patients,with area under the ROC curve(AUC)values of 0.928(95%CI 0.901-0.956)in the training set,0.919(95%CI 0.891-0.949)in the test set,and 0.941(95%CI 0.915-0.967)in the external validation set.SHAP values indicated the following order of variable importance in the model(from highest to lowest):"lactate dehydrogenase""blood chlorine""multiple organ injury""carbon dioxide combining power""prothrombin time""α-hydroxybutyric acid""creatine kinase isoenzyme""Stanford classification""combined use of bedside blood purification""gender""acute kidney injury""gastrointestinal bleeding""brain injury"and"shock".A risk prediction website for adverse postoperative outcomes in AAD patients was developed using XGBoost-SHAP method(https://dun-dunxiaolu.shinyapps.io/document/)and validated with examples.One randomly selected patient from each of the test and external validation sets was applied:the predicted mortality risk value for patient 1(who died postoperatively)was 0.9539,and that for patient 2(who survived postoperatively)was 0.0206.Conclusions The XGBoost-SHAP model demonstrates high accuracy in predicting postoperative mortality risk for AAD patients.The online prediction tool established based on this model enhances the identification efficiency of high-risk postoperative mortality patients.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
9.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
10.18F-FDG PET/CT in Predicting WHO(2021)Histological Grades of Invasive Pulmonary Adenocarcinoma
Qin SHI ; Yifan ZHANG ; Yi YANG ; Bo PAN ; Ming NI
Chinese Journal of Medical Imaging 2025;33(2):171-176,178
Purpose To investigate the role of 18F-FDG PET/CT in predicting histological grade of invasive pulmonary adenocarcinoma in the WHO(2021)classification.Materials and Methods The Clinical,pathological and PET/CT data of 255 patients with invasive pulmonary adenocarcinoma confirmed by surgical pathology were retrospectively analyzed from May 2015 to August 2023.Tertiary tumor grading was performed according to the WHO(2021)classification.The clinicopathologic features,maximum standardized uptake value(SUVmax),maximum standardized uptake,total lesion glycolysis and CT imaging findings were compared among the three tumor grades.Logistic regression analysis was used to screen the independent predictors for grade 3 tumors,and performance evaluation was performed using receiver operating characteristic curve.Results Higher tumor grade was associated with male sex(χ2=11.803,P=0.003),smoking history(χ2=7.702,P=0.021),maximum tumor diameter(H=20.548,P=0.002),lymph node metastasis(P<0.001),vascular cancer thrombus(χ2=33.270,P<0.001),pleural invasion(χ2=15.116,P=0.001)and airway spread(χ2=17.867,P<0.001).SUVmax(H=71.488,P<0.001),total lesion glycolysis(H=30.658,P<0.001)and the proportion of pure solid tumors on CT image(χ2=28.872,P<0.001)all increased significantly with higher tumor grade.A higher SUVmax(OR=1.234,95%CI 1.141-1.334,P<0.001)and pure solid appearance(OR=2.205,95%CI 1.166-4.171,P=0.015)were independent predictors of grade 3 tumors.The area under the receiver operating characteristic curve for SUVmax,CT solid appearance and the combination for predicting grade 3 tumors was 0.793,0.641 and 0.804,respectively,with the SUVmax cut-off of 6.08.Conclusion SUVmax and CT solid appearance are independent predictive factors for grade 3 invasive pulmonary adenocarcinoma.Preoperative 18F-FDG PET/CT can assist in evaluating the grading of invasive pulmonary adenocarcinoma,which improves treatment decision-making.

Result Analysis
Print
Save
E-mail