1.Analysis of clinical applicability and implementation of expert consensus on the implementation and removal of protective restraints in psychiatry
Jianing GU ; Dongmei XU ; Jing SHAO ; Jing GAO ; Zhuang CAI ; Yanhua QU ; Xiaolu YE ; Mengqian ZHANG ; Dongli MEI ; Yanhong ZHANG ; Bo YANG ; Gen CHENG ; Lina WANG ; Junrong YE ; Ruiyue LIN ; Yongling ZHOU ; Runjuan MA
Chinese Journal of Nursing 2025;60(11):1359-1365
Objective To understand the clinical applicability and implementation of expert consensus on the implementation and removal of protective restraints in psychiatry,and to provide references for promoting the standardized practice of psychiatric protective restraints and updating the consensus.Methods By the convenience sampling method,a questionnaire survey was conducted among nurses from 480 hospitals in 30 provinces from June 15 to July 15,2024.The survey was conducted using the instrument for evaluating clinical applicability of guide-lines(version 2.0)and a self-compiled questionnaire on the clinical implementation of the restraint consensus.Results A total of 7,844 valid questionnaires were collected,with a valid questionnaire recovery rate of 93.78%.The results of clinical applicability scoring showed that the consensus had the lowest availability score(64.72%)and the highest acceptability score(76.74%).The results showed that nurses' receiving training and the level of their hospitals were the main influencing factors for scores in various dimensions(P<0.05).4,774 participants(87.42%)believed that the application of consensus could enhance the standardization of nurses' restraint operations.The safety rate of the restraint consensus was 79.51%,and the economic ratio was 76.87%.Among the evaluators,1,739(22.17%)believed that there were implementation obstacles in the consensus.Conclusion The clinical applicability of the consensus is relatively good,and the application of the consensus helps to improve the standardization of clinical operations.In the future,efforts should be made to strengthen the promotion and training of the consensus,develop hierarchical promotion strategies according to the characteristics of medical institutions,and improve the quality of evidence for the consensus,so as to further enhance the clinical application effect of the consensus.
2.Shear wave elastography for evaluating therapeutic effect of ultrasound-guided drug injection for muscle injury
Lingjie YANG ; Guoxiang SUN ; Ping HU ; Qizhi HE ; Ming LI ; Hai LI ; Zhuang TANG ; Bo SHEN
Chinese Journal of Interventional Imaging and Therapy 2025;22(7):463-466
Objective To observe the value of shear wave elastography(SWE)for evaluating therapeutic effect of ultrasound-guided drug injection for muscle injury.Methods Eighty patients with unilateral muscle injury were retrospectively included,including 40 cases underwent ultrasound-guided drug injection(group A)and 40 cases underwent electromagnetic wave physiotherapy plus external application of Yunnan Baiyao Gao(group B).Pain intensity was assessed using visual analogue scale(VAS)before treatment and 3 weeks after the final treatment,while the Young modulus(E)value of the injured muscle was measured before treatment and 1,2 and 3 weeks after final treatment,and the improvements of VAS scores and E values were compared between groups.Results The total effective rate in group A(35/40,87.50%)was higher than that in group B(21/40,52.50%;P<0.05).Before treatment,no significant difference of VAS score was found between group A(8.07±0.83)and group B(7.88±0.85)(P>0.05).After treatment,VAS scores decreased in both groups(both P<0.05),which in group A(2.30±1.07)was more obviously than that in group B(4.80±0.82)(P<0.05).After treatment,E values of injury muscles increased significantly in both groups(P<0.05),while group A had a greater increase in overall magnitude and overall rate than group B(P<0.05).Conclusion Ultrasound-guided drug injection therapy had significant therapeutic effect for muscle injuries,which could be dynamically monitored with SWE.
3.Risk factors for postoperative respiratory failure in patients with esophageal cancer and the prediction model establishment
Bo YANG ; Yue BAI ; Lili LANG ; Qun CAO ; Gongjian ZHU ; Leiyun ZHUANG ; Daqiang SUN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):353-359
Objective To explore the risk factors for postoperative respiratory failure (RF) in patients with esophageal cancer, construct a predictive model based on the least absolute shrinkage and selection operator (LASSO)-logistic regression, and visualize the constructed model. Methods A retrospective analysis was conducted on patients with esophageal cancer who underwent surgical treatment in the Department of Thoracic Surgery, Sun Yat-sen University Cancer Center Gansu Hospital from 2020 to 2023. Patients were divided into a RF group and a non-RF (NRF) group according to whether RF occurred after surgery. Clinical data of the two groups were collected, and LASSO-logistic regression was used to optimize feature selection and construct the predictive model. The model was internally validated by repeated sampling 1000 times based on the Bootstrap method. Results A total of 217 patients were included, among which 24 were in the RF group, including 22 males and 2 females, with an average age of (63.33±9.10) years; 193 were in the NRF group, including 161 males and 32 females, with an average age of (62.14±8.44) years. LASSO-logistic regression analysis showed that the percentage of forced expiratory volume in one second/forced vital capacity (FEV1/FVC) to predicted value (FEV1/FVC%pred) [OR=0.944, 95%CI (0.897, 0.993), P=0.026], postoperative anastomotic fistula [OR=4.106, 95%CI (1.457, 11.575), P=0.008], and postoperative lung infection [OR=3.776, 95%CI (1.373, 10.388), P=0.010] were risk factors for postoperative RF in patients with esophageal cancer. Based on the above risk factors, a predictive model was constructed, with an area under the receiver operating characteristic curve of 0.819 [95%CI (0.737, 0.901)]. The Hosmer-Lemeshow test for the calibration curve showed that the model had good goodness of fit (P=0.527). The decision curve showed that the model had good clinical net benefit when the threshold probability was between 5% and 50%. Conclusion FEV1/FVC%pred, postoperative anastomotic fistula, and postoperative lung infection are risk factors for postoperative RF in patients with esophageal cancer. The predictive model constructed based on LASSO-logistic regression analysis is expected to help medical staff screen high-risk patients for early individualized intervention.
4.Survey and analysis of use and quality control of nitrocellulose membranes in in vitro diagnostic reagent manufacturing enterprises
Zheng-shan WU ; Bo-yang ZHUANG ; Qian-qian LI ; Yu-ting ZHU
Chinese Medical Equipment Journal 2025;46(7):75-80
Totally 45 in vitro diagnostic(IVD)reagent manufacturing enterprises were investigated in terms of the use and quality control of nitrocellulose(NC)membranes.The influences of the NC membrane performance indexes on IVD reagent quality were analyzed,including the within-run stability,crawling speed,protein absorption and pore size.The defficiencies of the enterprises were pointed out in the acceptance standard of NC membrane,and some suggestions were put forward including enhancing the performance of domestic NC membrane,improving the acceptance standard,optimizing NC membrane supply chain management by the enterprises and strengthening the internal management of the enterprises.References were provided for the development of IVD industries.[Chinese Medical Equipment Journal,2025,46(7):75-80]
5.Shear wave elastography for evaluating therapeutic effect of ultrasound-guided drug injection for muscle injury
Lingjie YANG ; Guoxiang SUN ; Ping HU ; Qizhi HE ; Ming LI ; Hai LI ; Zhuang TANG ; Bo SHEN
Chinese Journal of Interventional Imaging and Therapy 2025;22(7):463-466
Objective To observe the value of shear wave elastography(SWE)for evaluating therapeutic effect of ultrasound-guided drug injection for muscle injury.Methods Eighty patients with unilateral muscle injury were retrospectively included,including 40 cases underwent ultrasound-guided drug injection(group A)and 40 cases underwent electromagnetic wave physiotherapy plus external application of Yunnan Baiyao Gao(group B).Pain intensity was assessed using visual analogue scale(VAS)before treatment and 3 weeks after the final treatment,while the Young modulus(E)value of the injured muscle was measured before treatment and 1,2 and 3 weeks after final treatment,and the improvements of VAS scores and E values were compared between groups.Results The total effective rate in group A(35/40,87.50%)was higher than that in group B(21/40,52.50%;P<0.05).Before treatment,no significant difference of VAS score was found between group A(8.07±0.83)and group B(7.88±0.85)(P>0.05).After treatment,VAS scores decreased in both groups(both P<0.05),which in group A(2.30±1.07)was more obviously than that in group B(4.80±0.82)(P<0.05).After treatment,E values of injury muscles increased significantly in both groups(P<0.05),while group A had a greater increase in overall magnitude and overall rate than group B(P<0.05).Conclusion Ultrasound-guided drug injection therapy had significant therapeutic effect for muscle injuries,which could be dynamically monitored with SWE.
6.Analysis of clinical applicability and implementation of expert consensus on the implementation and removal of protective restraints in psychiatry
Jianing GU ; Dongmei XU ; Jing SHAO ; Jing GAO ; Zhuang CAI ; Yanhua QU ; Xiaolu YE ; Mengqian ZHANG ; Dongli MEI ; Yanhong ZHANG ; Bo YANG ; Gen CHENG ; Lina WANG ; Junrong YE ; Ruiyue LIN ; Yongling ZHOU ; Runjuan MA
Chinese Journal of Nursing 2025;60(11):1359-1365
Objective To understand the clinical applicability and implementation of expert consensus on the implementation and removal of protective restraints in psychiatry,and to provide references for promoting the standardized practice of psychiatric protective restraints and updating the consensus.Methods By the convenience sampling method,a questionnaire survey was conducted among nurses from 480 hospitals in 30 provinces from June 15 to July 15,2024.The survey was conducted using the instrument for evaluating clinical applicability of guide-lines(version 2.0)and a self-compiled questionnaire on the clinical implementation of the restraint consensus.Results A total of 7,844 valid questionnaires were collected,with a valid questionnaire recovery rate of 93.78%.The results of clinical applicability scoring showed that the consensus had the lowest availability score(64.72%)and the highest acceptability score(76.74%).The results showed that nurses' receiving training and the level of their hospitals were the main influencing factors for scores in various dimensions(P<0.05).4,774 participants(87.42%)believed that the application of consensus could enhance the standardization of nurses' restraint operations.The safety rate of the restraint consensus was 79.51%,and the economic ratio was 76.87%.Among the evaluators,1,739(22.17%)believed that there were implementation obstacles in the consensus.Conclusion The clinical applicability of the consensus is relatively good,and the application of the consensus helps to improve the standardization of clinical operations.In the future,efforts should be made to strengthen the promotion and training of the consensus,develop hierarchical promotion strategies according to the characteristics of medical institutions,and improve the quality of evidence for the consensus,so as to further enhance the clinical application effect of the consensus.
7.Survey and analysis of use and quality control of nitrocellulose membranes in in vitro diagnostic reagent manufacturing enterprises
Zheng-shan WU ; Bo-yang ZHUANG ; Qian-qian LI ; Yu-ting ZHU
Chinese Medical Equipment Journal 2025;46(7):75-80
Totally 45 in vitro diagnostic(IVD)reagent manufacturing enterprises were investigated in terms of the use and quality control of nitrocellulose(NC)membranes.The influences of the NC membrane performance indexes on IVD reagent quality were analyzed,including the within-run stability,crawling speed,protein absorption and pore size.The defficiencies of the enterprises were pointed out in the acceptance standard of NC membrane,and some suggestions were put forward including enhancing the performance of domestic NC membrane,improving the acceptance standard,optimizing NC membrane supply chain management by the enterprises and strengthening the internal management of the enterprises.References were provided for the development of IVD industries.[Chinese Medical Equipment Journal,2025,46(7):75-80]
8.Current progress in role of circular RNA in stroke
Di LÜ ; Hengqian DUAN ; Zhujun ZHUANG ; Peng CHEN ; Renhua YANG ; Zhiqiang SHEN ; Bo HE
Chinese Journal of Pathophysiology 2024;40(6):1114-1121
Stroke is a cerebrovascular disease characterized by high rates of disability,recurrence and mortal-ity.It results primarily from cerebrovascular rupture or transient/permanent occlusion.Due to the complex pathological mechanism of stroke and the lack of early-stage biomarkers,effective treatment options remain limited.Circular RNAs(circRNAs)are stable and conserved endogenous long noncoding RNA that regulate the pathological process of stroke,in-cluding oxidative stress,inflammation,apoptosis and autophagy.In addition,the regulatory roles of circRNAs in stroke include ceRNA,DNA methylation and histone modification.This review provides a comprehensive overview of circRNA biogenesis,major functions and characteristics.Furthermore,it presents the latest research findings on circRNAs in the context of stroke pathology,with the aim of providing new insights and potential approaches for unraveling the underlying mechanism,diagnosis and treatment of such diseases.
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail