1.Quality Evaluation of Naomaili Granules Based on Multi-component Content Determination and Fingerprint and Screening of Its Anti-neuroinflammatory Substance Basis
Ya WANG ; Yanan KANG ; Bo LIU ; Zimo WANG ; Xuan ZHANG ; Wei LAN ; Wen ZHANG ; Lu YANG ; Yi SUN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):170-178
ObjectiveTo establish an ultra-performance liquid fingerprint and multi-components determination method for Naomaili granules. To evaluate the quality of different batches by chemometrics, and the anti-neuroinflammatory effects of water extract and main components of Naomaili granules were tested in vitro. MethodsThe similarity and common peaks of 27 batches of Naomaili granules were evaluated by using Ultra performance liquid chromatography (UPLC) fingerprint detection. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was used to determine the content of the index components in Naomaili granules and to evaluate the quality of different batches of Naomaili granules by chemometrics. LPS-induced BV-2 cell inflammation model was used to investigate the anti-neuroinflammatory effects of the water extract and main components of Naomaili granules. ResultsThe similarity of fingerprints of 27 batches of samples was > 0.90. A total of 32 common peaks were calibrated, and 23 of them were identified and assigned. In 27 batches of Naomaili granules, the mass fractions of 14 components that were stachydrine hydrochloride, leonurine hydrochloride, calycosin-7-O-glucoside, calycosin,tanshinoneⅠ, cryptotanshinone, tanshinoneⅡA, ginsenoside Rb1, notoginsenoside R1, ginsenoside Rg1, paeoniflorin, albiflorin, lactiflorin, and salvianolic acid B were found to be 2.902-3.498, 0.233-0.343, 0.111-0.301, 0.07-0.152, 0.136-0.228, 0.195-0.390, 0.324-0.482, 1.056-1.435, 0.271-0.397, 1.318-1.649, 3.038-4.059, 2.263-3.455, 0.152-0.232, 2.931-3.991 mg∙g-1, respectively. Multivariate statistical analysis showed that paeoniflorin, ginsenoside Rg1, ginsenoside Rb1 and staphylline hydrochloride were quality difference markers to control the stability of the preparation. The results of bioactive experiment showed that the water extract of Naomaili granules and the eight main components with high content in the prescription had a dose-dependent inhibitory effect on the release of NO in the cell supernatant. Among them, salvianolic acid B and ginsenoside Rb1 had strong anti-inflammatory activity, with IC50 values of (36.11±0.15) mg∙L-1 and (27.24±0.54) mg∙L-1, respectively. ConclusionThe quality evaluation method of Naomaili granules established in this study was accurate and reproducible. Four quality difference markers were screened out, and eight key pharmacodynamic substances of Naomaili granules against neuroinflammation were screened out by in vitro cell experiments.
2.Application effect of narrow band imaging combined with magnifying endoscopy in early gastric cancer screening
Ting ZHANG ; Na HE ; Na YE ; Ya-jun LI ; Bo HAO
Journal of Regional Anatomy and Operative Surgery 2025;34(9):776-779
Objective To analyze the application effect of narrow band imaging(NBI)combined with magnifying endoscopy(ME)in early gastric cancer(EGC)screening.Methods A total of 199 patients who found focal lesions by ordinary white light endoscopy(WLE)were selected from April 2022 to October 2023.NBI combined with ME examination was performed,and histopathological examination of the specimen obtained from the lesion area was conducted.The pathological diagnosis results were recorded,and the endoscopic image qualities of WLE and NBI combined with ME examination were observed.The consistency between WLE,NBI combined with ME and patho-logical diagnosis was analyzed.The diagnostic value of WLE and NBI combined with ME for EGC was evaluated.Results The image qualities of microvascular and glandular duct by NBI combined with ME were better than those by WLE(P<0.05).The consistency between WLE diagnosis and pathological diagnosis was comparatively strong(Kappa=0.687).The consistency between NBI combined with ME and pathological diagnosis was very strong(Kappa=0.947).The consistency between NBI combined with ME and pathological diagnosis was better than that of WLE.The sensitivity,specificity,positive predictive value,negative predictive value,accuracy,and area under the curve(AUC)of NBI combined with ME in diagnosing EGC were higher than those of WLE,with statistically significant differences(P<0.05).The AUC of NBI combined with ME for diagnosing EGC was higher than that of WLE,with statistically significant difference(Z=3.493,P=0.000).Conclusion NBI combined with ME can increase the diagnostic efficiency of EGC,along with good image quality.
3.Design and performance verification of high altitude adaptive oxygen generator
Bo WANG ; Xiao-feng LIU ; Wen-jia LIU ; Yi LI ; Ya-nan WU ; Shu-jie CUI ; Wei ZHANG
Chinese Medical Equipment Journal 2025;46(4):29-34
Objective To design a high altitude adaptive oxygen generator for the crews to alleviate their high altitude reaction in high altitude environment and meet their requirements for oxygen supply.Methods A high altitude adaptive oxygen generator based on the mature pressure swing adsorption oxygen production method was designed with the key technologies of discharge capacity compensation of air compression pump and airway fusion of molecular sieve tower,which had the components of molecular sieve tower,air compression pump,controller,cooling fan,cooler,solenoid valve,regulator,flow meter and etc.Trials were carried out at the simulated altitude and field plateau environment so as to verify the high altitude adaptive performance of the oxygen generator developed.Results The trial results showed the oxygen generator met the desired objectives and the requirements for oxygen volume fraction in GJB 2799-1996 General specification for medical oxygen generator using molecular sieve method.Conclusion The oxygen generartor provides oxygen supply effectively for vehicle operators in plateau environments or the ones rushing into the plateau.[Chinese Medical Equipment Journal,2025,46(4):29-34]
4.Application effect of narrow band imaging combined with magnifying endoscopy in early gastric cancer screening
Ting ZHANG ; Na HE ; Na YE ; Ya-jun LI ; Bo HAO
Journal of Regional Anatomy and Operative Surgery 2025;34(9):776-779
Objective To analyze the application effect of narrow band imaging(NBI)combined with magnifying endoscopy(ME)in early gastric cancer(EGC)screening.Methods A total of 199 patients who found focal lesions by ordinary white light endoscopy(WLE)were selected from April 2022 to October 2023.NBI combined with ME examination was performed,and histopathological examination of the specimen obtained from the lesion area was conducted.The pathological diagnosis results were recorded,and the endoscopic image qualities of WLE and NBI combined with ME examination were observed.The consistency between WLE,NBI combined with ME and patho-logical diagnosis was analyzed.The diagnostic value of WLE and NBI combined with ME for EGC was evaluated.Results The image qualities of microvascular and glandular duct by NBI combined with ME were better than those by WLE(P<0.05).The consistency between WLE diagnosis and pathological diagnosis was comparatively strong(Kappa=0.687).The consistency between NBI combined with ME and pathological diagnosis was very strong(Kappa=0.947).The consistency between NBI combined with ME and pathological diagnosis was better than that of WLE.The sensitivity,specificity,positive predictive value,negative predictive value,accuracy,and area under the curve(AUC)of NBI combined with ME in diagnosing EGC were higher than those of WLE,with statistically significant differences(P<0.05).The AUC of NBI combined with ME for diagnosing EGC was higher than that of WLE,with statistically significant difference(Z=3.493,P=0.000).Conclusion NBI combined with ME can increase the diagnostic efficiency of EGC,along with good image quality.
5.Design and performance verification of high altitude adaptive oxygen generator
Bo WANG ; Xiao-feng LIU ; Wen-jia LIU ; Yi LI ; Ya-nan WU ; Shu-jie CUI ; Wei ZHANG
Chinese Medical Equipment Journal 2025;46(4):29-34
Objective To design a high altitude adaptive oxygen generator for the crews to alleviate their high altitude reaction in high altitude environment and meet their requirements for oxygen supply.Methods A high altitude adaptive oxygen generator based on the mature pressure swing adsorption oxygen production method was designed with the key technologies of discharge capacity compensation of air compression pump and airway fusion of molecular sieve tower,which had the components of molecular sieve tower,air compression pump,controller,cooling fan,cooler,solenoid valve,regulator,flow meter and etc.Trials were carried out at the simulated altitude and field plateau environment so as to verify the high altitude adaptive performance of the oxygen generator developed.Results The trial results showed the oxygen generator met the desired objectives and the requirements for oxygen volume fraction in GJB 2799-1996 General specification for medical oxygen generator using molecular sieve method.Conclusion The oxygen generartor provides oxygen supply effectively for vehicle operators in plateau environments or the ones rushing into the plateau.[Chinese Medical Equipment Journal,2025,46(4):29-34]
6.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
7.Association between insulin resistance and idiopathic central precocious puberty in girls and the diagnostic value of insulin resistance
Jin-Bo LI ; Ya XIAO ; Shu-Qin JIANG ; Xiang-Yang LUO ; Hong-Ru ZHANG ; Jun SUN ; Wen-Hui SHI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(12):1487-1492
Objective To explore the relationship between insulin resistance and idiopathic central precocious puberty(ICPP)in girls and the diagnostic value of insulin resistance.Methods Clinical data of 245 girls aged 4 to 7.5 years with low luteinizing hormone(LH)levels(0.2-0.83 IU/L),normal body weight(body mass index standard deviation score between-2 and+2),and early breast development who visited the Department of Pediatric Endocrinology,Henan Provincial Maternal and Child Health Hospital from January 2022 to March 2025 were retrospectively analyzed.According to the Expert Consensus on the Diagnosis and Treatment of Central Precocious Puberty(2022),patients were assigned to an ICPP group(n=123)or a control group(n=122).Correlations between the homeostasis model assessment of insulin resistance(HOMA-IR)and selected indices were assessed.Multivariable logistic regression was used to evaluate the association between HOMA-IR and ICPP,and the diagnostic performance of various indices for ICPP was evaluated.Results HOMA-IR was higher in the ICPP group than in the control group(P<0.001)and was positively correlated with LH peak(rs=0.467,P<0.05)and the LH peak/FSH peak ratio(rs=0.444,P<0.05).The multivariable logistic regression model including age,BMI,and basal LH showed that HOMA-IR was closely associated with ICPP(OR=2.756,95%CI:1.940-3.913).Receiver operating characteristic curve analysis showed that the areas under the curve for basal LH,HOMA-IR,and their combination in diagnosing ICPP were 0.735,0.735,and 0.805,respectively(P<0.05),and the combined model had a greater area under the curve than either basal LH or HOMA-IR alone(both P<0.05).Conclusions HOMA-IR is closely associated with ICPP in girls with low LH and normal body weight,and combining HOMA-IR with basal LH improves early identification and diagnostic efficiency in this population.
8.Association between insulin resistance and idiopathic central precocious puberty in girls and the diagnostic value of insulin resistance
Jin-Bo LI ; Ya XIAO ; Shu-Qin JIANG ; Xiang-Yang LUO ; Hong-Ru ZHANG ; Jun SUN ; Wen-Hui SHI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(12):1487-1492
Objective To explore the relationship between insulin resistance and idiopathic central precocious puberty(ICPP)in girls and the diagnostic value of insulin resistance.Methods Clinical data of 245 girls aged 4 to 7.5 years with low luteinizing hormone(LH)levels(0.2-0.83 IU/L),normal body weight(body mass index standard deviation score between-2 and+2),and early breast development who visited the Department of Pediatric Endocrinology,Henan Provincial Maternal and Child Health Hospital from January 2022 to March 2025 were retrospectively analyzed.According to the Expert Consensus on the Diagnosis and Treatment of Central Precocious Puberty(2022),patients were assigned to an ICPP group(n=123)or a control group(n=122).Correlations between the homeostasis model assessment of insulin resistance(HOMA-IR)and selected indices were assessed.Multivariable logistic regression was used to evaluate the association between HOMA-IR and ICPP,and the diagnostic performance of various indices for ICPP was evaluated.Results HOMA-IR was higher in the ICPP group than in the control group(P<0.001)and was positively correlated with LH peak(rs=0.467,P<0.05)and the LH peak/FSH peak ratio(rs=0.444,P<0.05).The multivariable logistic regression model including age,BMI,and basal LH showed that HOMA-IR was closely associated with ICPP(OR=2.756,95%CI:1.940-3.913).Receiver operating characteristic curve analysis showed that the areas under the curve for basal LH,HOMA-IR,and their combination in diagnosing ICPP were 0.735,0.735,and 0.805,respectively(P<0.05),and the combined model had a greater area under the curve than either basal LH or HOMA-IR alone(both P<0.05).Conclusions HOMA-IR is closely associated with ICPP in girls with low LH and normal body weight,and combining HOMA-IR with basal LH improves early identification and diagnostic efficiency in this population.
9.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail