1.Effects of donor gender on short-term survival of lung transplant recipients: a single-center retrospective cohort study
Xiaoshan LI ; Shiqiang XUE ; Min XIONG ; Rong GAO ; Ting QIAN ; Lin MAN ; Bo WU ; Jingyu CHEN
Organ Transplantation 2025;16(4):591-598
Objective To evaluate the effect of donor gender on short-term survival rate of lung transplant recipients. Methods A retrospective analysis was conducted on the data of 1 066 lung transplant recipients. The log-rank test was used to evaluate the differences in short-term fatality among different donor gender groups and donor-recipient gender combination groups. Multivariate Cox regression, propensity score (PS) regression, and propensity score matching (PSM) were employed to control for confounding factors and further assess the differences in fatality. Subgroup analyses were also performed based on donor gender. Results Multivariate Cox regression analysis showed no statistically significant differences in fatality at 30 days, 1 year, 2 years and 3 years postoperatively between male and female donor groups (all P>0.05). After PS regression and PSM, univariate Cox regression analysis indicated that recipients from female donors had a higher fatality at 2 years postoperatively compared to those from male donors, with hazard ratios (95% confidence intervals) of 1.29 (1.01-1.65) and 1.36 (1.03-1.80) respectively. Multivariate Cox regression analysis also revealed no statistically significant differences in fatality at various follow-up time points among different donor-recipient gender combination groups (all P>0.05). Subgroup analyses based on donor sex showed no statistically significant differences in fatality among recipients of different gender within either male or female donor groups (all P>0.05). Conclusions Female donors may reduce the short-term postoperative survival rate of lung transplant recipients, but this negative impact is not sustainable in the long term. At present, there is no evidence to support the inclusion of sex as a factor in lung allocation rules.
2.Percutaneous endoscopic discectomy with lateral approach and dual-channel method for the treatment of highly free lumbar disc herniation.
Qi-Ming CHEN ; Chun-Hua YU ; Gang CHEN ; Han-Rong XU ; Yi-Biao JING ; Yin-Jiang LU ; Shan-Chun TAO ; Jian-Bo WU
China Journal of Orthopaedics and Traumatology 2025;38(9):924-929
OBJECTIVE:
To explore clinical efficacy of percutaneous endoscopic discectomy with a lateral approach and dual-channel method in treating highly free lumbar disc herniation(LDH).
METHODS:
A retrospective analysis was conducted on 54 patients with highly free LDH who were treated with spinal endoscopic techniques from January 2021 to December 2022. Twenty-seven patients were treated with lateral approach dual-channel(lateral approach dual-channel group), including 16 males and 11 females, with an average age of (54.6±10.5) years old. Twenty-seven patients were treated with unilateral biportal endoscopic (UBE group), including 17 males and 10 females, with an average age of (52.9±12.3) years old. The number of intraoperative fluoroscopy, operation time and hospital stay, as well as visual analogue scale (VAS) and Oswestry diability index (ODI) of low back and leg pain between two patients before operation, 1 day, 1, 3, and 12 months after operation, and the efficacy was evaluated by the modified MacNab criteria at 12 mohths after operation.
RESULTS:
All patients were successfully completed surgical and were followed up, the time raged from 12 to 22 months with an average of (13.57±4.12) months. There was no statistically significant difference in operation time between two groups (P>0.05). The hospital stay of lateral approach dual-channel group was (3.9±1.1) days, which was shorter than that of UBE group (6.5±1.4) days, the number of intraoperative fluoroscopy in lateral approach dual-channel group was (12.7±2.1) times, which was more than that in UBE group (6.6±1.3) times, the differences were statistically significant (t=5.197, -7.532;P<0.05). VAS and ODI for low back pain at 1 day and 1 month after operation, and VAS for leg pain at 1 day after operation of lateral approach dual-channel group were superior to those of UBE group, and the differences were statistically significant (P<0.05). However, there were no statistically significant differences in VAS and ODI for low back and leg pain between two groups before operation and 3 and 12 months after operation (P>0.05). VAS and ODI of low back and leg pain were significantly improved at each time point before and after operation in both groups, and the difference were statistically significant (P<0.05). At 12 months after operation, according to the modified MacNab criteria, the excellent and good rates of therapeutic effects between lateral approach dual-channel group and UBE group were 92.6% (25/27) and 88.9% (24/27), respectively, and the difference was not statistically significant (χ2=0.22, P>0.05).
CONCLUSION
For patients with highly free lumbar intervertebral disc protrusion, both of lateral approach dual-channel method and UBE endoscopic surgery are safe and effective. Endoscopic surgery with lateral approach and dual-channel method could be performed under local anesthesia, allowing for the removal of the nucleus pulposus under direct vision. It is simpler, more efficient.
Humans
;
Male
;
Female
;
Intervertebral Disc Displacement/surgery*
;
Middle Aged
;
Diskectomy, Percutaneous/methods*
;
Lumbar Vertebrae/surgery*
;
Endoscopy/methods*
;
Adult
;
Retrospective Studies
;
Aged
3.Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
Xiang ZHAO ; Xiang-Hua WANG ; Rong-Xin HE ; Xun-Zi CAI ; Li-Dong WU ; Hao-Bo WU ; Shi-Gui YAN
China Journal of Orthopaedics and Traumatology 2025;38(10):987-993
OBJECTIVE:
To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:
A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:
All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION
The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Aged, 80 and over
;
Workflow
;
Treatment Outcome
4.Exploring the causal relationship between leukocyte telomere length and prostatitis, orchitis, and epididymitis based on a two-sample Mendelian randomization.
Dan-Yang LI ; Shun YU ; Bo-Hui YANG ; Jun-Bao ZHANG ; Guo-Chen YIN ; Lin-Na WU ; Qin-Zuo DONG ; Jin-Long XU ; Shu-Ping NING ; Rong ZHAO
National Journal of Andrology 2025;31(4):306-312
OBJECTIVE:
To investigate the genetic causal relationship of leukocyte telomere length (LTL) with prostatitis, orchitis and epididymitis by two-sample Mendelian randomization (MR).
METHODS:
Using LTL as the exposure factor and prostatitis, orchitis and epididymitis as outcome factors, we mined the Database of Genome-Wide Association Studies (GWAS). Then, we analyzed the causal relationship of LTL with prostatitis, orchitis and epididymitis by Mendelian randomization using inverse variance weighting (IVW) as the main method and weighted median and MR-Egger regression as auxiliary methods, determined the horizontal multiplicity by MR-Egger intercept test, and conducted sensitivity analysis using the leaving-one-out method.
RESULTS:
A total of 121 related single nucleotide polymorphisms (SNPs) were identified in this study. IVW showed LTL to be a risk factor for prostatitis (OR = 1.383, 95% CI: 1.044-1.832, P = 0.024), and for orchitis and epididymitis as well (OR = 1.770, 95% CI: 1.275-2.456, P = 0.000 6).
CONCLUSION
Genetic evidence from Mendelian randomized analysis indicates that shortening of LTL reduces the risk of prostatitis, orchitis and epididymitis.
Humans
;
Male
;
Mendelian Randomization Analysis
;
Epididymitis/genetics*
;
Prostatitis/genetics*
;
Polymorphism, Single Nucleotide
;
Leukocytes
;
Orchitis/genetics*
;
Genome-Wide Association Study
;
Telomere
;
Risk Factors
5.Clinical and genetic analysis of a patient with FSIP2 compound heterozygous variants causing multiple morphological abnormalities of sperm flagella.
Yao-Qi CHEN ; Li-Qi XU ; Yi-Bo DAI ; Liang-Yu YAO ; Shen-Ming YANG ; Lu-Yu HUANG ; Xi YANG ; Yi YU ; Jing-Ming YANG ; Ke-Rong WU
National Journal of Andrology 2025;31(5):395-402
OBJECTIVE:
The aim of this study is to analyze the clinical features and genetic etiology of a patient with multiple morphological abnormalities of the sperm flagella (MMAF) retrospectively.
METHODS:
A severely oligospermic patient from the Reproductive Center of the First Affiliated Hospital of Ningbo University was selected as the study subject. Clinical data and examination results were collected. High-throughput sequencing and bioinformatics were used to analyze the genetic etiology. And Sanger sequencing was employed to validate findings in the family. Transmission electron microscopy (TEM) was used to observe the sperm ultrastructure, and immunofluorescence analysis was performed to examine the localization of FSIP2 protein in the sperm.
RESULTS:
The patient presented with severe oligospermia, and sperm morphology displayed MMAF. TEM revealed fibrous sheath and 9+2 microtubule structural disruptions in the sperm. Sequencing identified compound heterozygous variants in the FSIP2 gene (c.17798C > T, c.5927T > G), inherited from the father and mother, respectively. According to the guidelines of the American College of Medical Genetics and Genomics, the variants were classified as pathogenic. The patient's spouse underwent intracytoplasmic single sperm injection, resulting in one embryo, but no clinical pregnancy occurred after embryo transfer.
CONCLUSION
This study reported the mutation of FSIP2 gene c.17798C > T, c.5927T > G in a patient with MMAF. These findings expand the mutational spectrum of the FSIP2 gene and provide insights for genetic and assisted reproductive counseling for patients with MMAF.
Humans
;
Male
;
Sperm Tail/pathology*
;
Heterozygote
;
Oligospermia/genetics*
;
Spermatozoa
;
Mutation
;
Infertility, Male/genetics*
;
Adult
;
Pedigree
;
Retrospective Studies
;
Sperm Injections, Intracytoplasmic
6.Chromatin landscape alteration uncovers multiple transcriptional circuits during memory CD8+ T-cell differentiation.
Qiao LIU ; Wei DONG ; Rong LIU ; Luming XU ; Ling RAN ; Ziying XIE ; Shun LEI ; Xingxing SU ; Zhengliang YUE ; Dan XIONG ; Lisha WANG ; Shuqiong WEN ; Yan ZHANG ; Jianjun HU ; Chenxi QIN ; Yongchang CHEN ; Bo ZHU ; Xiangyu CHEN ; Xia WU ; Lifan XU ; Qizhao HUANG ; Yingjiao CAO ; Lilin YE ; Zhonghui TANG
Protein & Cell 2025;16(7):575-601
Extensive epigenetic reprogramming involves in memory CD8+ T-cell differentiation. The elaborate epigenetic rewiring underlying the heterogeneous functional states of CD8+ T cells remains hidden. Here, we profile single-cell chromatin accessibility and map enhancer-promoter interactomes to characterize the differentiation trajectory of memory CD8+ T cells. We reveal that under distinct epigenetic regulations, the early activated CD8+ T cells divergently originated for short-lived effector and memory precursor effector cells. We also uncover a defined epigenetic rewiring leading to the conversion from effector memory to central memory cells during memory formation. Additionally, we illustrate chromatin regulatory mechanisms underlying long-lasting versus transient transcription regulation during memory differentiation. Finally, we confirm the essential roles of Sox4 and Nrf2 in developing memory precursor effector and effector memory cells, respectively, and validate cell state-specific enhancers in regulating Il7r using CRISPR-Cas9. Our data pave the way for understanding the mechanism underlying epigenetic memory formation in CD8+ T-cell differentiation.
CD8-Positive T-Lymphocytes/metabolism*
;
Cell Differentiation
;
Chromatin/immunology*
;
Animals
;
Mice
;
Immunologic Memory
;
Epigenesis, Genetic
;
SOXC Transcription Factors/immunology*
;
NF-E2-Related Factor 2/immunology*
;
Mice, Inbred C57BL
;
Gene Regulatory Networks
;
Enhancer Elements, Genetic
7.Laboratory Diagnosis and Molecular Epidemiological Characterization of the First Imported Case of Lassa Fever in China.
Yu Liang FENG ; Wei LI ; Ming Feng JIANG ; Hong Rong ZHONG ; Wei WU ; Lyu Bo TIAN ; Guo CHEN ; Zhen Hua CHEN ; Can LUO ; Rong Mei YUAN ; Xing Yu ZHOU ; Jian Dong LI ; Xiao Rong YANG ; Ming PAN
Biomedical and Environmental Sciences 2025;38(3):279-289
OBJECTIVE:
This study reports the first imported case of Lassa fever (LF) in China. Laboratory detection and molecular epidemiological analysis of the Lassa virus (LASV) from this case offer valuable insights for the prevention and control of LF.
METHODS:
Samples of cerebrospinal fluid (CSF), blood, urine, saliva, and environmental materials were collected from the patient and their close contacts for LASV nucleotide detection. Whole-genome sequencing was performed on positive samples to analyze the genetic characteristics of the virus.
RESULTS:
LASV was detected in the patient's CSF, blood, and urine, while all samples from close contacts and the environment tested negative. The virus belongs to the lineage IV strain and shares the highest homology with strains from Sierra Leone. The variability in the glycoprotein complex (GPC) among different strains ranged from 3.9% to 15.1%, higher than previously reported for the seven known lineages. Amino acid mutation analysis revealed multiple mutations within the GPC immunogenic epitopes, increasing strain diversity and potentially impacting immune response.
CONCLUSION
The case was confirmed through nucleotide detection, with no evidence of secondary transmission or viral spread. The LASV strain identified belongs to lineage IV, with broader GPC variability than previously reported. Mutations in the immune-related sites of GPC may affect immune responses, necessitating heightened vigilance regarding the virus.
Humans
;
China/epidemiology*
;
Genome, Viral
;
Lassa Fever/virology*
;
Lassa virus/classification*
;
Molecular Epidemiology
;
Phylogeny
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail