1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Association of Body Mass Index with All-Cause Mortality and Cause-Specific Mortality in Rural China: 10-Year Follow-up of a Population-Based Multicenter Prospective Study.
Juan Juan HUANG ; Yuan Zhi DI ; Ling Yu SHEN ; Jian Guo LIANG ; Jiang DU ; Xue Fang CAO ; Wei Tao DUAN ; Ai Wei HE ; Jun LIANG ; Li Mei ZHU ; Zi Sen LIU ; Fang LIU ; Shu Min YANG ; Zu Hui XU ; Cheng CHEN ; Bin ZHANG ; Jiao Xia YAN ; Yan Chun LIANG ; Rong LIU ; Tao ZHU ; Hong Zhi LI ; Fei SHEN ; Bo Xuan FENG ; Yi Jun HE ; Zi Han LI ; Ya Qi ZHAO ; Tong Lei GUO ; Li Qiong BAI ; Wei LU ; Qi JIN ; Lei GAO ; He Nan XIN
Biomedical and Environmental Sciences 2025;38(10):1179-1193
OBJECTIVE:
This study aimed to explore the association between body mass index (BMI) and mortality based on the 10-year population-based multicenter prospective study.
METHODS:
A general population-based multicenter prospective study was conducted at four sites in rural China between 2013 and 2023. Multivariate Cox proportional hazards models and restricted cubic spline analyses were used to assess the association between BMI and mortality. Stratified analyses were performed based on the individual characteristics of the participants.
RESULTS:
Overall, 19,107 participants with a sum of 163,095 person-years were included and 1,910 participants died. The underweight (< 18.5 kg/m 2) presented an increase in all-cause mortality (adjusted hazards ratio [ aHR] = 2.00, 95% confidence interval [ CI]: 1.66-2.41), while overweight (≥ 24.0 to < 28.0 kg/m 2) and obesity (≥ 28.0 kg/m 2) presented a decrease with an aHR of 0.61 (95% CI: 0.52-0.73) and 0.51 (95% CI: 0.37-0.70), respectively. Overweight ( aHR = 0.76, 95% CI: 0.67-0.86) and mild obesity ( aHR = 0.72, 95% CI: 0.59-0.87) had a positive impact on mortality in people older than 60 years. All-cause mortality decreased rapidly until reaching a BMI of 25.7 kg/m 2 ( aHR = 0.95, 95% CI: 0.92-0.98) and increased slightly above that value, indicating a U-shaped association. The beneficial impact of being overweight on mortality was robust in most subgroups and sensitivity analyses.
CONCLUSION
This study provides additional evidence that overweight and mild obesity may be inversely related to the risk of death in individuals older than 60 years. Therefore, it is essential to consider age differences when formulating health and weight management strategies.
Humans
;
Body Mass Index
;
China/epidemiology*
;
Male
;
Female
;
Middle Aged
;
Prospective Studies
;
Rural Population/statistics & numerical data*
;
Aged
;
Follow-Up Studies
;
Adult
;
Mortality
;
Cause of Death
;
Obesity/mortality*
;
Overweight/mortality*
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Multicolor Fluorescent Copper Nanoclusters/Starch Composites and Their Application in Fingermark Development
Chuan-Jun YUAN ; Ming LI ; Yi-Fei SUN ; Jia-Ming LYU ; Zhi-Bo GAO ; Shi-Qiang SUN ; Pei-Liang HAN ; Feng-He LIU
Chinese Journal of Analytical Chemistry 2025;53(1):55-64,中插1-中插3
On the basis of that the fluorescence wavelength of copper nanoclusters(CuNCs)could cover the entire visible region,multicolor fluorescent CuNCs/starch composites were prepared and applied in fingermark development.With L-glutathione as the reducing agent and protective ligand,blue emissive and orange emissive CuNCs solutions were obtained in alkaline solutions at 90℃and 25℃,respectively.With the aggregation-induced emission effect induced by ethanol as a poor solvent,the fluorescence of orange emissive CuNCs with a higher intensity was achieved in an ethanol-water solution.With ascorbic acid as the reducing agent and 3-mercaptopropionic acid as the protective agent,green emissive CuNCs solution was prepared in an acid solution.Particle morphologies,chemical compositions and optical properties of these three CuNCs above were investigated using physical characterization and spectroscopic analysis,indicating that well-dispersed CuNCs had excellent photoluminescent properties.These CuNCs solutions were combined with starch to form composite powders by simply drying.The influences of the type of CuNCs and the ratio of CuNCs to starch on the emission wavelength and fluorescence intensity of the products were studied.The obtained CuNCs/starch composites could emit blue,green and orange fluorescence under 365 nm ultraviolet light,respectively,which were suitable for fingermark development.Minutiae and partial level-3 features of latent fingermarks could be effectively developed.High-quality fluorescence fingermark images would be captured using appropriate optical filters to eliminate background interference of various substrates.
9.Research Progress on Electrochemical Sensing Techniques for Detection of Telomerase Activity
Hai-Tang YANG ; Peng-Hua SHU ; Wen-Lin LIU ; Wen-Bo MA ; Zi-Jun YANG ; Zhi-Feng DENG ; Xin-Yun ZHANG ; Wei WEI
Chinese Journal of Analytical Chemistry 2025;53(6):864-874
The telomere structure in the cell nucleus is crucial for maintaining the stability and functions of chromosomes.Telomerase is a ribonucleoprotein reverse transcriptase,which catalyzes the elongation of telomeres using its own RNA as a template,thereby counteracting the shortening of telomeres caused by chromosome replication and cell division.Due to its overexpression in over 85%of malignant tumor cells,telomerase has emerged as a highly promising biomarker and a novel target for cancer therapy.In recent years,given the importance of precise quantification of telomerase activity in guiding medical diagnosis and treatment strategies,researchers have developed various high-performance telomerase detection techniques.Among these,electrochemical biosensing technique has cause much attention due to its high sensitivity,operational convenience,rapid response,and ease of miniaturization.This paper focused on the latest advances in electrochemical sensing technique for detection of telomerase activity,aiming to provide inspiration for designing novel telomerase activity detection strategies by elucidating three unique properties of telomerase primer extension products.
10.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.

Result Analysis
Print
Save
E-mail