1.Research on BP Neural Network Method for Identifying Cell Suspension Concentration Based on GHz Electrochemical Impedance Spectroscopy
An ZHANG ; A-Long TAO ; Qi-Hang RAN ; Xia-Yi LIU ; Zhi-Long WANG ; Bo SUN ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1302-1312
ObjectiveThe rapid advancement of bioanalytical technologies has heightened the demand for high-throughput, label-free, and real-time cellular analysis. Electrochemical impedance spectroscopy (EIS) operating in the GHz frequency range (GHz-EIS) has emerged as a promising tool for characterizing cell suspensions due to its ability to rapidly and non-invasively capture the dielectric properties of cells and their microenvironment. Although GHz-EIS enables rapid and label-free detection of cell suspensions, significant challenges remain in interpreting GHz impedance data for complex samples, limiting the broader application of this technique in cellular research. To address these challenges, this study presents a novel method that integrates GHz-EIS with deep learning algorithms, aiming to improve the precision of cell suspension concentration identification and quantification. This method provides a more efficient and accurate solution for the analysis of GHz impedance data. MethodsThe proposed method comprises two key components: dielectric property dataset construction and backpropagation (BP) neural network modeling. Yeast cell suspensions at varying concentrations were prepared and separately introduced into a coaxial sensor for impedance measurement. The dielectric properties of these suspensions were extracted using a GHz-EIS dielectric property extraction method applied to the measured impedance data. A dielectric properties dataset incorporating concentration labels was subsequently established and divided into training and testing subsets. A BP neural network model employing specific activation functions (ReLU and Leaky ReLU) was then designed. The model was trained and tested using the constructed dataset, and optimal model parameters were obtained through this process. This BP neural network enables automated extraction and analytical processing of dielectric properties, facilitating precise recognition of cell suspension concentrations through data-driven training. ResultsThrough comparative analysis with conventional centrifugal methods, the recognized concentration values of cell suspensions showed high consistency, with relative errors consistently below 5%. Notably, high-concentration samples exhibited even smaller deviations, further validating the precision and reliability of the proposed methodology. To benchmark the recognition performance against different algorithms, two typical approaches—support vector machines (SVM) and K-nearest neighbor (KNN)—were selected for comparison. The proposed method demonstrated superior performance in quantifying cell concentrations. Specifically, the BP neural network achieved a mean absolute percentage error (MAPE) of 2.06% and an R² value of 0.997 across the entire concentration range, demonstrating both high predictive accuracy and excellent model fit. ConclusionThis study demonstrates that the proposed method enables accurate and rapid determination of unknown sample concentrations. By combining GHz-EIS with BP neural network algorithms, efficient identification of cell concentrations is achieved, laying the foundation for the development of a convenient online cell analysis platform and showing significant application prospects. Compared to typical recognition approaches, the proposed method exhibits superior capabilities in recognizing cell suspension concentrations. Furthermore, this methodology not only accelerates research in cell biology and precision medicine but also paves the way for future EIS biosensors capable of intelligent, adaptive analysis in dynamic biological research.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Experimental study on autologous osteochondral transplantation in the treatment of recurrent anterior dislocation of the shoulder joint with articular cartilage defect in rabbits.
Tao LIU ; Sen FANG ; Fang-Xiang LIU ; Ming-Tao ZHANG ; Zhi-Tao YANG ; Bo-Rong ZHANG ; Jun-Wen LIANG ; Xi-Hao WANG ; Jin JIANG ; Xiang-Dong YUN
China Journal of Orthopaedics and Traumatology 2025;38(6):619-625
OBJECTIVE:
To explore clinical effect of autologous osteochondral transplantation (AOT) in the treatment of recurrent anterior dislocation of the shoulder joint with glenoid cartilage defect in rabbits by establishing a model of recurrent anterior dislocation of the shoulder joint with < 20% glenoid cartilage defect in rabbits.
METHODS:
Twenty-four male New Zealand white rabbits, aged 6-month-old, weighed (2.69±0.17) kg were selected. The labrum of shoulder joint of rabbits was artificially destroyed to establish a model of recurrent anterior dislocation of shoulder joint with cartilage defect. They were divided into AOT surgery group and simple suture group, with 12 rabbits in each group. AOT group were underwent AOT surgery, while simple suture group was treated with simple Bankart suture for recurrent shoulder joint dislocation. At 6 and 12 weeks after operation, 6 rabbits between two groups were sacrificed for sampling. The dietary conditions, activity conditions, mental states of rabbits and healing conditions of grafts in the specimens were observed and compared between two groups. HE staining was used to observe cell creep, cell morphology, inflammatory cell infiltration, fibrochondrocytes and their arrangement. Masson staining was used to observe the formation and arrangement of collagen fibers; Safrane-green staining was used to observe the regeneration of articular cartilage, subchondral bone and bone tissue. Bone mineral density (BMD), bone volume (BV) and trabecular thickness (Tb.Th) between two groups were measured by Micro-CT to evaluate the remodeling of shoulder glenoid bone defects by autologous osteochondral cartilage.
RESULTS:
After different surgical interventions were carried out in both groups of rabbits, at 6 weeks after the operation, the abduction, extension, internal rotation and external rotation of the shoulder joint on the operated side showed limited range of motion compared with the contralateral side, while adduction and forward flexion showed no obvious abnormalities compared with the contralateral side. At 12 weeks after operation, the range motion of tshoulder joints in both groups of rabbits had returned to the state before modeling. The effects of HE staining, Masson staining and safrane-green staining at 12 weeks after operation in both groups were stronger than the staining results at 6 weeks after operation. Moreover, the results of HE staining, Masson staining and safranin fixation green staining in AOT group at 6 and 12 weeks after operation were all higher than those in simple suture group. Micro-CT scan results at 6 and 12 weeks after operation showed that BMD (0.427±0.014), (0.466±0.032) g·cm-3, BV(116.171±3.527), (159.327±3.500) mm3, and Tb.Th (0.230±0.006), (0.285±0.009) mm in AOT group, which were higher than those of simple suture group in BMD(0.358±0.011), (0.384±0.096) g·cm-3, BV(72.657±3.903), (118.713±3.860) mm3, and Tb.Th(0.204±0.009), (0.243±0.007) mm;and the differences were statistically significant (P<0.05).
CONCLUSION
AOT procedure could effectively promote osteogenesis and fibrocartilage regeneration in the cartilage defect area of the shoulder glenoid <20%, which is conducive to reshaping the structure of the shoulder glenoid.
Animals
;
Rabbits
;
Male
;
Transplantation, Autologous
;
Cartilage, Articular/injuries*
;
Shoulder Dislocation/physiopathology*
;
Bone Transplantation
;
Shoulder Joint/surgery*
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Mechanism of Regulating MK2 to Improve Bone Marrow Inflammatory Damage after Hematopoietic Stem Cell Transplantation.
Zhao-Hui WANG ; Bo LONG ; Yu-Han WANG ; Zhi-Ting LIU ; Zi-Jie XU ; Shuang DING
Journal of Experimental Hematology 2025;33(5):1453-1460
OBJECTIVE:
To investigate the role of MK2 inhibitor MMI-0100 on inflammatory response after allogeneic hematopoietic stem cell transplantation (allo-HSCT) and related mechanisms.
METHODS:
An allo-HSCT mouse model was established. Recipient rats were randomly divided into BMT+NaCl group and BMT+MMI-0100 group, and were injected with NaCl and MMI-0100 every day after transplantation, respectively. Samples of the two groups were collected on d 7 and 14, femur paraffin sections were stained with HE, and pathological changes in the bone marrow cavity were observed under the light microscope. The gene and protein expression levels of pro-inflammatory cytokines IL-1β and IL-18 were detected by qPCR and Western blot. Macrophage typing was detected by flow cytometry. The expression levels of NLRP3 and Caspase-1 were detected by Western blot.
RESULTS:
Inflammatory cell infiltration in the bone marrow cavity was significantly reduced in the BMT+MMI-0100 group. Western blot results showed that the protein expression levels of IL-1β and IL-18 in the BMT+MMI-0100 group were decreased compared to the BMT+NaCl group on day 7 and day 14 (all P <0.01). The qPCR results showed that compared to the BMT+NaCl group, the IL-18 gene expression levels in the BMT+MMI-0100 group were significantly reduced on day 7 and day 14 (both P <0.01). In the BMT+MMI-0100 group, the expression level of IL-1β gene decreased on day 7 (P <0.05), but increased and was higher than that in the BMT+NaCl group on day 14 (P <0.05). Flow cytometry results showed that the expression of M1 macrophages and M1/M2 ratio decreased in the BMT+MMI-0100 group compared to BMT+NaCl group (all P <0.05). Western blot results showed that the protein expression levels of NLRP3 and Caspase-1 in the BMT+MMI-0100 group were lower than those in the BMT+NaCl group (all P <0.05).
CONCLUSION
MMI-0100 can ameliorate bone marrow inflammatory injury after allo-HSCT and may act by reducing NLRP3 expression to promote M2 polarization.
Animals
;
Interleukin-1beta/metabolism*
;
Rats
;
Interleukin-18/metabolism*
;
Hematopoietic Stem Cell Transplantation/adverse effects*
;
Mice
;
NLR Family, Pyrin Domain-Containing 3 Protein/metabolism*
;
Inflammation
;
Bone Marrow/pathology*
;
Protein Serine-Threonine Kinases/metabolism*
;
Intracellular Signaling Peptides and Proteins/antagonists & inhibitors*
;
Caspase 1/metabolism*
;
Macrophages
;
Transplantation, Homologous
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
9.Disease burden and clinical status of congenital heart disease combined with heart failure in China: a survey and analysis
Zixian SHENG ; Yuxing YUAN ; Fangjie WANG ; Zhi CHEN ; Ying GUO ; Xing SHEN ; Xuecun LIANG ; Lingjuan LIU ; Jiajin LI ; Xiaoli YAN ; Bo PAN ; Jie TIAN
Chinese Journal of Pediatrics 2025;63(2):148-156
Objective:To investigate the disease burden, clinical characteristics and independent risk factors affecting in-hospital outcomes of children with congenital heart disease (CHD) combined with heart failure (HF) in China.Methods:(1) Descriptive study: based on the global burden of disease study 2021, available data on children under 15 years of age with CHD and HF in China from 1990 to 2021 were collected. The prevalence and trends in different age subgroups (<1 year, 1-<2 years, 2-<5 years, 5-<10 years, 10-<15 years) were analyzed, and the annual percentage change (EAPC) was estimated using linear regression. (2) Retrospective cohort study: a total of 1 062 children with CHD and HF from a multicenter study on pediatric HF in China were included. The children were divided into two groups:<2 years group and 2-<18 years group. Data on demographics, clinical features, diagnosis, treatments, and in-hospital outcomes were analyzed. Mann-Whitney U test and chi-square test were used for group comparisons.Multivariable Logistic regression was applied to identify factors influencing outcomes (in-hospital mortality and adverse cardiovascular events). Results:(1) From 1990 to 2021, the number of children with CHD and HF in China increased from 333 000 (95% uncertainty interval ( UI) 271 000-405 000) to 368 000 (95% UI 296 000-459 000), a growth of 10.8% (95% UI 5.0%-16.6%). Concurrently the prevalence rate increased from 104.5 (95% UI 85.1-127.3) per 100 000 to 142.0 (95% UI 114.0-176.8) per 100 000, a growth of 35.9% (95% UI 28.7%-43.0%), with an EAPC of 1.5% (95% CI 1.2%-1.8%). Although the number of cases in the<1 year and 1-<2 years groups decreased by 41.0% and 25.6%, respectively, the prevalence in all age groups showed an upward trend:<1 year EAPC 0.6% (95% CI 0.5%-0.7%); 1-<2 years EAPC 0.9% (95% CI 0.8%-1.0%); 2-<5 years EAPC 1.2% (95% CI 1.0%-1.4%); 5-<10 years EAPC 1.5% (95% CI 1.2%-1.8%); 10-<15 years EAPC 2.1% (95% CI 1.9%-2.3%). (2) The multicenter study revealed that among 1 062 hospitalized children, 528 (49.7%) were male and 534 (50.3%) were female, with the age at admission of 5.4 (2.2,18.2) months. The majority of the children (77.9%, 827/1 062) were under 2 years of age, whereas 22.1% (235/1 062) were aged between 2-<18 years. Children with complex congenital heart defects accounted for the highest proportion (48.6%, 516/1 062), while those with isolated CHD made up 31.5% (335/1 062). Statistically significant differences were observed in several variables in demographics, clinical features, diagnosis, treatments, and outcomes between the two age groups (all P<0.05). The use of renin-angiotensin-aldosterone system inhibitors (41.1%, 436/1 062) and beta-blockers (8.7%, 92/1 062) was lower in hospitalized children with CHD and HF. Logistic regression identified complex CHD ( OR=7.73, 95% CI 2.24-26.63; OR=3.17, 95% CI 1.92-5.23), pulmonary hyperperfusion ( OR=2.15, 95% CI 1.01-4.18; OR=2.00, 95% CI 1.35-2.97), left ventricular ejection fraction<55% ( OR=2.13, 95% CI 1.08-4.21; OR=2.80, 95% CI 1.45-5.56), arterial oxygen partial pressure ( OR=0.99, 95% CI 0.98-0.99; OR=0.99, 95% CI 0.98-0.99), and serum calcium levels ( OR=0.31, 95% CI 0.17-0.58; OR=0.42, 95% CI 0.28-0.62) as independent risk factors for in-hospital mortality and cardiovascular events. Conclusions:The disease burden of CHD combined with HF in China has shown a continuous upward trend from 1990 to 2021, with higher growth rates in older age groups. Complex CHD, pulmonary hyperperfusion, left ventricular ejection fraction <55%, arterial oxygen partial pressure, and serum calcium concentration are independent risk factors for in-hospital mortality and cardiovascular events.
10.Predictive value of IVST,E/A combined AV for hypertensive heart disease and their association with blood pressure grade
Cui-cui LIU ; Yi HE ; Jing-qi QIU ; Shuang LIANG ; Qian WANG ; Zhi-bo ZHANG
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(3):374-379
Objective:To investigate the predictive value of interventricular septal thickness(IVST),the ratio of mitral ear-ly diastolic peak flow velocity to late diastolic peak flow velocity(E/A)combined with aortic valve flow velocity(AV)for hypertensive heart disease(HHD)and its association with blood pressure grade.Methods:A total of 202 patients with hy-pertension suspected of HHD admitted to Qinhuangdao Hospital of Dongfang Hospital,Beijing University of Chinese Medi-cine between May 2020 and May 2023 were enrolled and divided into HHD group(n=102)and non-HHD group(n=100)according to color Doppler energy imaging and blood pressure diagnosis.Blood pressure,IVST,E/A and AV were measured in two groups.The predictive value of IVST,E/A and AV for HHD were evaluated by receiver operating charac-teristic(ROC)curve.According to hypertension grading,patients in HHD group was divided into grade 1~2 group(n=59)and grade 3 group(n=41).The association of IVST,E/A,AV with blood pressure grade in HHD patients were ana-lyzed by Spearman correlation analysis.Results:Compared with patients in non-HHD group,those in HHD group had significant higher IVST,and significant lower E/A and AV(P<0.001 all);Compared with patients in grade 1~2 group,those in grade 3 group had significant higher IVST,and significant lower E/A and AV(P<0.001 all).ROC curve showed that the AUC of IVST,E/A and AV alone and their combination in HHD diagnosis was 0.798(95%CI 0.736~0.851),0.682(95%CI 0.613~0.746),0.810(95%CI 0.748~0.862)and 0.927(95%CI 0.881~0.959)respectively,and the diagnostic value of combined detection was significantly higher than those of single detections(Z=4.431,5.669,3.948,P=0.001 all).Spearman correlation analysis showed that E/A and AV were significant negatively correlated with blood pressure grade(r=-0.725,-0.781),while I VST was significant positively correlated with blood pressure grade(r=0.714),and combined detection possessed a stronger correlation with it in HHD patients(r=0.875,P<0.001 all).Con-clusion:The combined detection of I VST,E/A and AV demonstrates a good predictive value for HHD and exhibits a sig-nificant correlation with blood pressure grade in HHD patients.

Result Analysis
Print
Save
E-mail