1.The Effect of Zhiqiao Gancao Decoction (枳壳甘草汤) on Intervertebral Disc Nucleus Pulposus Cell Apoptosis and the Hippo-YAP/TAZ Signaling Pathway in Tail Intervertebral Disc Degeneration Model Rats
Zaishi ZHU ; Zeling HUANG ; Junming CHEN ; Bo XU ; Binjie LU ; Hua CHEN ; Xingxing DUAN ; Yuwei LI ; Xiaofeng SHEN
Journal of Traditional Chinese Medicine 2025;66(5):509-517
ObjectiveTo investigate the possible mechanism by which Zhiqiao Gancao Decoction (枳壳甘草汤, ZGD) delays intervertebral disc degeneration (IDD) based on the Hippo-yes-associated protein (YAP)/transcriptional co-activator with PDZ-binding motif (TAZ) signaling pathway. MethodsA total of 50 SD rats were randomly divided into sham surgery group, model group, low-dose ZGD group, high-dose ZGD group, and high-dose ZGD + inhibitor group, with 10 rats in each group. In the sham surgery group, the rats were pierced in the skin and muscle at the Co6/7/8 segments of the tail with a 21G needle (depth approximately 2 mm) without damaging the intervertebral disc. In the other groups, rats were injected with a 21G needle at the Co6/7/8 segments of the tail to establish an IDD model by piercing the tail intervertebral disc 5 mm. One week after modeling, rats in the low-dose and high-dose ZGD groups were given 6.24 and 12.24 g/(kg·d) of the decoction via gastric gavage, respectively. The high-dose ZGD + inhibitor group was given 12.24 g/(kg·d) of the decoction and an intraperitoneal injection of YAP/TAZ inhibitor Verteporfin 10 mg/kg. The sham surgery and model groups were given 5 ml/(kg·d) of normal saline via gavage. The gavage was given once a day, and the intraperitoneal injection was given every other day. After 4 weeks of continuous intervention, the pathological changes of the tail intervertebral discs were observed using HE staining, Oil Red O-Green staining, and Toluidine Blue staining. Immunohistochemistry was used to detect the expression of aggrecan and MMP3 in the nucleus pulposus. TUNEL fluorescence staining was performed to detect apoptosis in the nucleus pulposus, and the apoptosis rate was calculated. Western blot was used to detect the Hippo-YAP/TAZ signaling pathway, including YAP, phosphorylated YAP (p-YAP), phosphorylated MST1/2 (p-MST1/2), phosphorylated TAZ (p-TAZ) and apoptosis-related proteins, such as Cleaved Caspase 3, P53, Bcl-2 and Bax. ResultsCompared with sham surgery group, the rats in the model group showed significant degenerative changes in the intervertebral disc. The levels of aggrecan, Bcl-2, and YAP proteins in the nucleus pulposus decreased, while the levels of p-MST1/2, p-YAP, p-TAZ, P53, Bax, Cleaved Caspase 3, MMP3 proteins, and the apoptosis rate increased (P < 0.01). Compared with the model group, the drug intervention groups showed partial recovery in intervertebral disc degeneration. The levels of aggrecan, Bcl-2, and YAP proteins increased, while the levels of p-MST1/2, p-YAP, p-TAZ, P53, Bax, Cleaved Caspase 3, MMP3 proteins, and the apoptosis rate decreased (P<0.05 or P<0.01). The high-dose ZGD group showed more significant recovery in intervertebral disc degeneration compared to the low-dose ZGD group, with a decrease in the levels of p-MST1/2, p-YAP, p-TAZ, P53, Bax, Cleaved Caspase 3, MMP3 proteins, and apoptosis rate, and an increase in the levels of aggrecan, Bcl-2, and YAP proteins (P<0.05 or P<0.01). Compared with the high-dose ZGD group, the high-dose ZGD + inhibitor group showed a reduced recovery in intervertebral disc degeneration, with an increase in the levels of p-MST1/2, p-YAP, p-TAZ, P53, Bax, Cleaved Caspase 3, MMP3 proteins, and apoptosis rate, and a decrease in the levels of aggrecan, Bcl-2, and YAP proteins (P<0.05 or P<0.01). ConclusionZGD may delay intervertebral disc degeneration by inhibiting the phosphorylation of YAP in the nucleus pulposus, maintaining the function of the Hippo-YAP/TAZ signaling pathway, and reducing apoptosis of nucleus pulposus cells.
2.Construction of Differentiation and Treatment System of Malignant Tumor under the Theory of "Ying-WeiDisorder" in The Inner Canon of Yellow Emperor (《黄帝内经》)
Yi LI ; Xiaochen JIANG ; Fudong LIU ; Qian SHEN ; Bo PANG ; Baojin HUA ; Bingkui PIAO
Journal of Traditional Chinese Medicine 2024;65(23):2408-2412
Ying and wei qi is derived from the essence of water and grain, and is the basic material to maintain the normal life activities of the body. Ying and wei qi has the difference of nature of yin and yang or the clear and the turbid. When the relationship between ying and wei qi is out of order and in reverse disorder, it will lead to the occurrence of various diseases. Based on the analysis of the theory of "ying-wei disorder" in The Inner Canon of Yellow Emperor (《黄帝内经》), this paper started from the perspective of the exuberance and debilitation, circulation and function of ying qi and wei qi, focused on the theoretical understanding that the change of deficiency and excess ("fall") and the change of circulation ("move"), and refined the core mechanism of "ying-wei disorder", which is the depletion of ying qi and wei qi, stagnation of ying qi and wei qi, and disharmony of ying qi and wei qi, and finally summarized the syndrome identification and treatment method of supporting ying qi and assisting wei qi, promoting ying qi and moving wei qi, regulating ying qi and wei qi, and constructed the syndrome identification and treatment system for ying-wei disorder of malignant tumor in clinic.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
7.IgA nephropathy with mesangial type Ⅲ collagen deposition:2 cases report
Jie-Bo HUANG ; Xiao-Fan CAI ; Zhong-Hua ZHAO ; Zhi-Gang ZHANG ; Qiang SHEN ; Hao WANG ; Hui-Juan WU
Fudan University Journal of Medical Sciences 2024;51(3):426-430
As interstitial collagen,type Ⅲ collagen(Col Ⅲ)does not express in normal glomeruli.However,in Col Ⅲ nephropathy,a large amount of Col Ⅲ deposit in the mesangial and subendothelial area of the glomeruli.IgA nephropathy with Col Ⅲ deposition was extremely rare.In this article,we reported two cases of such disease.After treating with immunosuppressive agents or traditional Chinese medicine decoction,the renal function of the two patients remained stable and the urinary protein levels reduced significantly.
8.Disease characteristics and costs of pediatric Mycoplasma Pneumoniae pneumonia hospitalization:a retrospective study at municipal hospitals from 2019 to 2023 in Shanghai
Ying-Wen WANG ; Feng WANG ; Li-Bo WANG ; Ai-Zhen LU ; Yi WANG ; Yong-Hao GUI ; Quan LU ; Yong YIN ; Jian-Hua ZHANG ; Ying-Zi YE ; Hong XU ; Bing SHEN ; Dan-Ping GU ; Xiao-Yan DONG ; Jia-Yu WANG ; Wen HE ; Xiao-Bo ZHANG
Fudan University Journal of Medical Sciences 2024;51(4):515-521
Objective To investigate disease characteristics and hospitalization costs of children with Mycoplasma Pneumoniae pneumonia(MPP)admitted to Shanghai municipal medical hospitals from 2019 to 2023.Methods Depending on the Shanghai Municipal Hospital Pediatric Alliance,we retrospectively investigated community acquired MPP pediatric patients hospitalized in 22 municipal hospitals with pediatric qualifications(including 4 children's hospitals)in Shanghai from Jan 2019 to Dec 2023.We collected the patients'diagnosis codes,gender,age,length of hospital stay,hospitalization costs,and whether they progressed to severe Mycoplasma pneumoniae pneumonia(SMPP).Results From 2019 to 2023,a total of 29 045 hospitalized children with MPP were treated,with 6 035 cases(20.8%)identified as SMPP in the 22 hospitals.Trend analysis revealed a rising trend with years in the proportion of SMPP patients(χ2trend=365.498,P<0.001).Among the 4 children's hospitals,there were 18 710 cases with MPP,including 4 078 cases(21.8%)of SMPP.The proportion of SMPP patients also showed an increasing trend with years(χ2trend=14.548,P<0.001),and the proportion in 2023(23.0%)was higher than that in previous years with statistical significance.There were statistical differences in the seasonal distribution of MPP cases between different years,with higher proportions in summer and autumn overall.The age distribution of hospitalized MPP children varied among different years,with school-age children accounting for the majority(56.8%)in 2023.There was no difference in the distribution of severe cases between different genders,but there were differences in the proportion of severe cases among different age groups in different years,with a gradual increase in severe cases among children aged 1 to 3 years(χ2trend=191.567,P<0.001).The average length of hospital stay for MPP during the epidemic was higher than that during non-epidemic periods,and there were statistically significant differences in the average length of hospital stay between different years(P<0.001).The individual hospitalization costs during the epidemic were higher than in other years,and there were statistically significant differences in individual hospitalization costs between different years(P<0.001).The total hospitalization costs were still higher in 2019 and 2023.The individual hospitalization costs for SMPP were higher than for non-SMPP cases.Conclusion MPP outbreaks occurred in Shanghai in 2019 and 2023,with the higher proportions in summer and autumn overall.Compared to previous years,the number of hospitalized MPP children in Shanghai was higher in 2023,with a higher proportion of SMPP cases,especially among children under 3 years old.The individual per capita hospitalization expenses for SMPP cases were higher than for non-SMPP cases.
9.Comparison of anterior lateral ligament reconstruction and anterior lateral complex repair in the treatment of anterior cruciate ligament combined with anterior lateral ligament injury with high-grade pivot shift.
Xue-Feng JIA ; Qing-Hua WU ; Tong-Bo DENG ; Xiao-Zhen SHEN ; Jian-Ping YE ; He FANG ; Rong-Chang ZHOU ; Yang CAO ; You-Fen CHEN ; Qi-Ning YANG ; Guo-Hong XU
China Journal of Orthopaedics and Traumatology 2024;37(11):1101-1106
OBJECTIVE:
To retrospectively analyze the clinical efficacy of anterior cruciate ligament (ACL) reconstruction combined with anterolateral complex repair and ACL reconstruction combined with ALL reconstruction in the treatment of anterior cruciate ligament injuries with high-grade pivot shift.
METHODS:
From January 2018 to June 2022, 49 patients combined ACL and ALL injuries with high-grade pivot shift were retrospectively studied from three hospitals, 29 of them underwent ACL reconstruction with anterolateral complex repair (repair group), including 23 males and 6 females with an average age of (27.5±4.8) years old, ranged from 20 to 37 years old;the injured sides were 13 on the left and 16 on the right, and 11 patients were suffered with meniscus injury. The other 20 patients underwent ACL and ALL reconstruction (reconstruction group) including 17 males and 3 females with the mean age of (27.1±4.5) years old, ranged from 20 to 38 years old;the injured sides were 8 on the left and 12 on the right, and 6 patients were suffered with meniscus injury. Knee stability (pivot shift test, KT-2000), range of motion, knee function (Lysholm scoring scale, Cincinnati sports activity scale (CSAS) scoring scale, and Tegner activity level score between two groups were compared.
RESULTS:
A total of 49 patients were followed up, the repair group receiving 13 to 20(15.3±1.8) months and the reconstruction group receiving 12 to 21(16.0±2.2) months. There was no statistically significant difference in the preoperative pivot shift test grading distribution between two groups (P>0.05). At the last postoperative follow-up, there were 24 patients with grade 0 and 5 patients with grade 1 in the repair group, and there were 18 patients with grade 0 and 2 patients with grade 1 in the reconstruction group, there is no significant difference in the distribution of axial shift test grading between two groups(P>0.05). The preoperative KT-2000 tibial displacement of two groups were (9.39±0.77) mm (repair group) and (9.14±0.78) mm (reconstruction group) respectively, with no statistically significant difference (P>0.05). At the final postoperative follow-up, there were 24 patients with KT-2000 tibial displacement <3 mm and 5 patients with 3 to 5 mm in the repair group, while 18 patients with <3 mm and 2 patients with 3 to 5 mm in the reconstruction group, KT-2000 tibial displacement distribution of two groups was no significant difference (P>0.05), but the KT-2000 tibial displacement in the reconstruction group (1.30±0.86) mm was significantly smaller than that in the repair group (1.99±1.11) mm (P<0.05). The final postoperative follow-up range of motion of the contralateral side knee between two groups was no significant difference (P>0.05). The range of motion of the suffering knee in the repair group was less than that in the reconstruction group (P<0.05). There was no significant difference in preoperative Lysholm and CSAS scores between two groups (P>0.05). At the final postoperative follow-up, both groups showed significant improvement in Lysholm and CSAS scores, while the Lysholm and CSAS scores of the reconstruction group were better than those of the repair group, and the difference was statistically significant (P<0.05). Significant differences was found in Tegner scores between two groups, which 16 patients in the repair group returned to their pre-injury activity level, and 17 patients in the reconstruction group returned to their pre-injury level (P<0.05).
CONCLUSION
Compared to anterolateral complex repair, combined ACL and ALL reconstruction in the treatment of ACL injuries with high-grade pivot shift results in better knee joint function and stability. This is advantageous in reducing the risk of ACL reconstruction failure.
Humans
;
Male
;
Female
;
Adult
;
Anterior Cruciate Ligament Reconstruction/methods*
;
Anterior Cruciate Ligament Injuries/surgery*
;
Young Adult
;
Retrospective Studies
;
Anterior Cruciate Ligament/surgery*
;
Range of Motion, Articular
10.GABAergic Retinal Ganglion Cells Projecting to the Superior Colliculus Mediate the Looming-Evoked Flight Response.
Man YUAN ; Gao TAN ; Danrui CAI ; Xue LUO ; Kejiong SHEN ; Qinqin DENG ; Xinlan LEI ; Wen-Bo ZENG ; Min-Hua LUO ; Lu HUANG ; Chaoran REN ; Yin SHEN
Neuroscience Bulletin 2024;40(12):1886-1900
The looming stimulus-evoked flight response to approaching predators is a defensive behavior in most animals. However, how looming stimuli are detected in the retina and transmitted to the brain remains unclear. Here, we report that a group of GABAergic retinal ganglion cells (RGCs) projecting to the superior colliculus (SC) transmit looming signals from the retina to the brain, mediating the looming-evoked flight behavior by releasing GABA. GAD2-Cre and vGAT-Cre transgenic mice were used in combination with Cre-activated anterograde or retrograde tracer viruses to map the inputs to specific GABAergic RGC circuits. Optogenetic technology was used to assess the function of SC-projecting GABAergic RGCs (scpgRGCs) in the SC. FDIO-DTA (Flp-dependent Double-Floxed Inverted Open reading frame-Diphtheria toxin) combined with the FLP (Florfenicol, Lincomycin & Prednisolone) approach was used to ablate or silence scpgRGCs. In the mouse retina, GABAergic RGCs project to different brain areas, including the SC. ScpgRGCs are monosynaptically connected to parvalbumin-positive SC neurons known to be required for the looming-evoked flight response. Optogenetic activation of scpgRGCs triggers GABA-mediated inhibition in SC neurons. Ablation or silencing of scpgRGCs compromises looming-evoked flight responses without affecting image-forming functions. Our study reveals that scpgRGCs control the looming-evoked flight response by regulating SC neurons via GABA, providing novel insight into the regulation of innate defensive behaviors.
Animals
;
Superior Colliculi/physiology*
;
Retinal Ganglion Cells/physiology*
;
GABAergic Neurons/physiology*
;
Mice, Transgenic
;
Mice
;
Optogenetics
;
Visual Pathways/physiology*
;
Mice, Inbred C57BL
;
Photic Stimulation/methods*
;
gamma-Aminobutyric Acid/metabolism*
;
Male

Result Analysis
Print
Save
E-mail