1.Quantification of Atmospheric Total Reactive Nitrogen Oxides by Thermal Decomposition-Broadband Cavity Enhanced Absorption Spectroscopy
Dou SHAO ; Min QIN ; Wu FANG ; Bao-Bin HAN ; Ke TANG ; Jian-Ye XIE ; Xia-Dan ZHAO ; Zhi-Tang LIAO ; En-Bo REN
Chinese Journal of Analytical Chemistry 2025;53(3):387-396
Nitrogen oxides(NOx=NO+NO2)are important precursors of ozone(O3),and NOx and its oxides together constitute reactive nitrogen oxides(NOy)in the atmosphere.A comprehensive understanding of the total NOy level in the atmosphere is of great significance for a deeper understanding of the atmospheric nitrogen cycle and oxidation,as well as for formulating strategies for air pollution prevention and control.In this work,a thermal decomposition-broadband cavity enhanced absorption spectroscopy(TD-BBCEAS)technique for online measurement of total NOy in the atmosphere was developed.With this method,the NOy was efficiently converted into NO2,and the total NOy concentration in the atmosphere was indirectly obtained by measuring NO2.Focusing on the key factors affecting the measurement of total NOy,the influence of NO titration efficiency and other NOy component TD efficiency on measurement accuracy was emphasized.By changing the oxygen(O2)flow rate through the mercury lamp to alter the O3 concentration for titrating NO,the conversion efficiency of NO was evaluated.At O2 flow rate of 6 mL/min,the conversion efficiency of NO was greater than 99%.TD efficiency testing and analysis on NO2,peroxyacetyl nitrate(PAN),nitric acid(HNO3),and nitrous acid(HONO),which account for a large proportion of atmospheric NOy components,was carried out using 680℃as the optimal TD temperature for efficient conversion of NOy.With NO and HONO sample gases as typical verification gases,the conversion efficiency of NOy and the accuracy of NOy measurement by TD-BBCEAS system were verified by switching the on and off modes of mercury lamp and TD device.At integration time of 60 s,the detection limit of the system for NOy was 2.83×1010 molecules/cm3(60 s,2σ).A comparative measurement of actual atmospheric NOy was conducted between the TD-BBCEAS system and the NOy analyzer.The observation results showed a correlation coefficient(R2)of 0.98 and a slope of 0.93,further verifying the feasibility and accuracy of applying the TD-BBCEAS system to measurement of total NOy.
2.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
3.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
4.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
5.Clinical study on neglected perforation of glove during spinal surgery
Xiao-fang SHAO ; Bo WANG ; Shan-shan TAN ; Wen-wen HE ; Yu-feng TIAN
Journal of Regional Anatomy and Operative Surgery 2025;34(5):417-420
Objective To specify the occurrence status,distribution characteristics and risk factors of neglected perforations in surgical gloves used during spinal surgery.Methods A total of 932 surgical gloves used during spinal surgery in our hospital from October 2022 to September 2024 were selected.The occurrence and distribution location of neglected perforations were counted.Univariate and binary Logistic regression analyses were respectively conducted on the factors that might lead to neglected perforations of gloves.Results Among the 932 surgical gloves used in spinal surgery selected in this study,a total of 122 gloves(13.09%)with neglected perforations were detected,of which the proportions of neglected perforations at the index finger of the left and right hands in the gloves were the highest,accounting for 37.50%and 37.93%respectively.The results of univariate and binary Logistic regression analyses showed that grade Ⅲ or Ⅳ surgery,open surgery,combined bone grafting operation,operation time≥120 minutes,use of rotating equipment,and gloves worn by instrument nurses were risk factors for neglected perforations(P<0.05,OR>1.0),while wearing double-layer gloves was a protective factor to avoid the occurrence of neglected perforations(P<0.05,OR<1.0).Conclusion The incidence of neglected perforations in surgical gloves used during spinal surgery is relatively high,especially in the area of the glove index finger.For high-risk spinal surgeries(grade Ⅲ or Ⅳ surgery,open surgeries,combined bone grafting procedures)and requiring rotating equipment,health care workers,especially instrumental nurses,are advised to wear double-layer gloves;furthermore,a 120-minute glove change regime is recommended,in order to reduce the incidence of neglected perforation.
6.Construction and validation of nomogram predictive model for postopera-tive healthcare-associated infection in lung transplant recipients
Sangsang QIU ; Qinfen XU ; Junfei SHAO ; Qinhong HUANG ; Bo WU ; Chunxiao HU ; Jingyu CHEN
Chinese Journal of Infection Control 2025;24(5):674-681
Objective To explore the risk factors for healthcare-associated infection(HAI)in lung transplant re-cipients(LTRs),and construct a predictive nomogram model.Methods Clinical data of patients who underwent lung transplant in Wuxi People's Hospital from January 2019 to December 2023 were analyzed retrospectively.The patients were divided into a training set(n=506)and a validation set(n=218).Independent risk factors were screened through LASSO regression,and multivariate logistic regression was included to construct a nomogram pre-diction model.The discrimination,calibration,and clinical applicability of the model were evaluated using receiver operating characteristic(ROC)curves,Hosmer-Lemeshow goodness-of-fit,and decision curves.Results Among the 506 LTRs,201 developed HAIs,with an incidence of 39.72%.The major infection site was lower respiratory tract,and the major pathogen were Gram-negative bacilli(Acinetobacter baumannii).Older age,use of extracorpo-real membrane oxygenation(ECMO),double-lung transplant,surgery duration>3 hours,long duration of contin-uous fever,frequent abnormal blood routine examination,and long duration of combined use of antimicrobial agents were identified as independent risk factors for HAI after lung transplant.The ROC curve analysis results showed that the areas under the curve(AUCs)of the training set and the validation set were 0.74(95%CI:0.70-0.78)and 0.71(95%CI:0.64-0.78),respectively.The Hosmer-Lemeshow test results showed that there was no sta-tistically significant difference between the predictive and actual probability of HAI(P>0.05).The clinical decision curve results indicated that the model had clinical benefits at a threshold probability value of 7%-71%.Conclusion The nomogram prediction model constructed in this study can effectively evaluate the risk of postoperative infection in LTRs.The model is stable and has high clinical application value,providing scientific reference for postoperative infection prevention and control.
7.EIF5A2 promotes epithelial mesenchymal transition in intrahepatic chol-angiocarcinoma cells through the PI3K/AKT signaling pathway
Shao-hua YANG ; Yong-ping XU ; Zhuo-yu ZHAO ; Shi-bo ZHANG ; Xing-bao FANG ; Zhou-jun LIAO
Chinese Journal of Current Advances in General Surgery 2025;28(10):757-762
Objective:To investigate the the differential expression of EIF5A2 in intrahepatic cholangiocarcinoma cell lines RBE,HCCC9810,and HUCCT1,and its effects on HCCC9810 cell migration and invasion,epithelial mesenchymal transition,and PI3K/AKT signaling pathway.Methods:The differential expression of EIF5A2 in RBE,HCCC9810,and HUCCT1 cell lines was detected using WB method.The HCCC9810 cell line,with the highest expression of EIF5A2,was selected for this experiment.The expression of EIF5A2 in HCCC9810 cell line was silenced by transient transfection of small interfering RNA.The best silencing effect of small interfering RNA was screened by WB.Scratch assay and Tran-swell migration invasion assay were used to detect the effect of silencing EIF5A2 on the migration and invasion ability of HCCC9810 cells.WB was used to detect the effect of silencing EIF5A2 on PI3K/AKT signaling pathway and epithelial mesenchymal transition in HCCC9810 cells.Results:The WB results showed that EIF5A2 had the highest expression in the HCCC9810 cell line,and siRNA1 had the best silencing effect on EIF5A2 in the HCCC9810 cell line.Scratch assay and Transwell migration invasion assay results showed that silencing EIF5A2 in the HCCC9810 cell line resulted in a decrease in cell invasion and metastasis ability(P<0.05).At the same time,the expression of p-PI3K and p-AKT in the PI3K/AKT signaling pathway was significantly decreased(P<0.05),while the epithelial cell marker E-cadherin expression increased(P<0.05)and the stromal cell marker N-cadherin expression decreased(P<0.05).Conclusion:EIF5A2 may promote epi-thelial mesenchymal transition and enhance the migration and invasion ability of intrahepatic cholangiocarcinoma cells through the PI3K/AKT signaling pathway.
8.Development and application of polysaccharide conjugate vaccine carrier protein
Jingxin LI ; Xiao MA ; Ang LIN ; Hongxing PAN ; Bo HAO ; Juan SHAO ; Yuezhu LI ; Yangting XU ; Zhujun SHAO ; Aiqiang XU
Chinese Journal of Preventive Medicine 2025;59(7):1131-1140
The development of polysaccharide conjugate vaccines, which convert polysaccharide antigens into T-cell-dependent immunogens through covalent conjugation with protein carriers, represents a critical strategy for enhancing immune protection in infants and young children. Globally licensed conjugate vaccines currently employ carrier proteins including Tetanus Toxoid, Diphtheria Toxoid, and Cross-Reacting Material 197. Recent advances have focused on three key areas: novel carrier protein discovery, optimized conjugation strategies, and evaluation of immune interference during co-administration of multivalent formulations. These efforts aim to achieve broader serotype coverage, prolonged protective efficacy, and simplified immunization schedules. This review synthesizes recent progress in carrier protein development, encompassing vaccine design principles, manufacturing processes, safety profiles, and epidemiological effectiveness. Furthermore, it critically examines current selection criteria for carrier proteins, their clinical applications, and persistent challenges, providing strategic insights to inform future conjugate vaccine development and immunization policy optimization in China.
9.Application of a new type of navigation assisted reduction device in reduction and fixation of A3N0/1 thoracolumbar fracture with the aid of navigation
Yili LI ; Yibao SUN ; Yaojun DAI ; Shuang CHEN ; Xiaoguang ZHOU ; Yong YANG ; Zhenhui ZHANG ; Zhe SHAO ; Xiaoteng LI ; Bo SUN ; Wei MEI
Chinese Journal of Orthopaedics 2025;45(14):918-927
Objective:To evaluate the clinical efficacy of a novel reduction device in the treatment of A3N0/1 thoracolumbar fracture using navigation-assisted techniques.Methods:A retrospective analysis was conducted on 45 patients (29 males, 16 females; mean age 40.67±16.11 years, range 24-57) with thoracolumbar fractures who underwent fracture reduction and pedicle screw fixation via the Wiltse approach at Zhengzhou Orthopaedic Hospital between January 2022 and January 2023. Injury levels included: T 10 in 2 cases, T 11 in 5 cases, T 12 in 13 cases, L 1 in 20 cases, L 2 in 3 cases, L 3 in 2 cases. All patients underwent fracture reduction via the Wiltse approach using the spinal fracture reduction instrument for vertebral body reduction. Among them, 20 patients received O-arm navigation-assisted internal fixation and vertebral reduction (O-arm group), while 25 received C-arm fluoroscopy-guided internal fixation and vertebral reduction (C-arm group). Operative time, intraoperative blood loss, vertebral reduction time using the instrument, first-time screw placement success rate, screw placement accuracy, and complications were compared. Mid-vertebral body height ratio (MVBHr), local Cobb angle of the fractured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) were compared preoperatively, at 1 week postoperatively, 3 months postoperatively, and final follow-up. Results:All surgeries were successfully completed in both groups. Operative time was significantly shorter in the O-arm group (106.8±14.4 min) than in the C-arm group (119.1±16.4 min, P<0.05). All patients were followed up for a mean duration of 15.9±3.9 months (range 12-20 months). Vertebral reduction time was significantly shorter in the O-arm group (11.0±2.2 min) than in the C-arm group (20.4±5.7 min, P<0.05). The first-time screw placement success rate was significantly higher in the O-arm group (100%) than in the C-arm group (95.3%, P<0.05). Screw placement accuracy (Grade I) was significantly higher in the O-arm group (117 screws, 97.5%) than in the C-arm group (136 screws, 90.7%, P<0.05). No cases of wrong-level surgery, infection, or spinal cord/nerve injury occurred. Both groups showed significant improvements in MVBHr, Cobb angle, VAS, and ODI at all postoperative time points compared to preoperative values ( P<0.05). At final follow-up, the O-arm group demonstrated significantly better outcomes than the C-arm group in MVBHr (90.6%±4.5% vs. 86.4%±6.9%, P<0.05), Cobb angle (7.6°±1.8° vs. 10.1°±3.2°, P<0.05), VAS (1.3±0.4 vs. 1.7±0.6, P<0.05), and ODI (4.6%±1.9% vs. 7.7%±2.0%, P<0.01). Conclusion:O-arm navigation-assisted intrasegmental push reduction for A3N0/1 type thoracolumbar fractures demonstrates advantages including faster and more accurate screw placement, precise reduction with improved outcomes, and significant postoperative pain relief.
10.Diagnostic value of the vesical imaging-reporting and data system in bladder urothelial carcinoma with variant histology
Linjing JIANG ; Xiao YANG ; Lingkai CAI ; Qiang CAO ; Wei TIAN ; Xiaotong LIU ; Bo LIANG ; Meihua JIANG ; Gongcheng WANG ; Qiang SHAO ; Hongliang QUE ; Xuping JIANG ; Qiang LYU
Chinese Journal of Urology 2025;46(10):751-758
Objective:To evaluate the diagnostic value of the vesical imaging-reporting and data system(VI-RADS)for determining muscle invasion in variant histology urothelial carcinoma(VUC)of the bladder.Methods:A retrospective analysis was performed on the pathological and imaging data of 518 bladder cancer patients admitted to Jiangsu Province Hospital between January 2013 and January 2023. Patients were stratified into pure urothelial carcinoma(PUC)group( n = 457)and variant urothelial carcinoma(VUC)group( n = 61)based on the presence of histological variants. In the PUC group,there were 390 males(85.3%)and 67 females(14.7%),with a mean age of(66.9 ± 11.2)years. Tumor characteristics included maximum diameter ≥ 30 mm in 149(32.6%),< 30 mm in 308(67.4%),multiple tumors in 147(32.2%),solitary in 310(67.8%),pedunculated morphology in 143(31.3%)and non-pedunculated in 314(68.7%). Histological grading identified high-grade tumors in 319 patients(69.8%)and low-grade tumors in 138(30.2%). Pathological stage distribution included 191 of T a(41.8%),127 of T 1(27.8%),76 of T 2(16.6%),47 of T 3(10.3%),and 16 of T 4(3.5%)patients. The VUC group included 61 patients,comprising 51 males(83.6%)and 10 females(16.4%),with a mean age of(65.8 ± 11.4)years. Tumor characteristics were maximum diameter ≥ 30 mm in 38(62.3%),< 30 mm in 23(37.7%),multiple tumors in 16(26.2%),solitary in 45(73.8%),pedunculated morphology in 11(18.0%)and non-pedunculated in 50(82.0%). Histological grading identified high-grade tumors in 59 patients(96.7%)and low-grade tumors in 2(3.3%). Pathological stage distribution included 3 of T a(4.9%),15 of T 1(24.6%),15 of T 2(24.6%),20 of T 3(32.8%),and 8 of T 4(13.1%)patients. No statistically significant differences were found between the two groups in gender,age,or tumor multiplicity( P > 0.05). Statistically significant differences were found in pathological grade,pathological stage,maximum tumor diameter,and pedunculated morphology( P < 0.05). Furthermore,an external validation cohort of 278 bladder cancer patients treated between February 2023 and February 2024 from multiple centers(Jiangsu Provincial People’s Hospital,The First Affiliated Hospital of Zhengzhou University,Union Hospital Tongji Medical College Huazhong University of Science and Technology,Jiangsu Provincial Hospital of Traditional Chinese Medicine,Suzhou Municipal Hospital,Huaian First People’s Hospital,Yixing People’s Hospital)was retrospectively analyzed to externally validate the performance of VI-RADS scoring in predicting muscle invasion of VUC. This cohort included a PUC subgroup of 241 patients,comprising 196 males(81.3%)and 45 females(18.7%),with a mean age of(68.0 ± 10.7)years. Tumor characteristics were maximum diameter ≥ 30 mm in 85(35.3%),< 30 mm in 156(64.7%),multiple tumors in 65(27.0%),solitary in 176(73.0%),pedunculated morphology in 76(31.5%)and non-pedunculated in 165(68.5%). Histological grading identified high-grade tumors in 175 patients(72.6%)and low-grade tumors in 66(27.4%). Pathological staging comprised 107 patients of T a(44.4%),78 of T 1(32.4%),22 of T 2(9.1%),22 of T 3(9.1%),and 12 of T 4(5.0%). The VUC subgroup consisted of 37 patients,comprising 29 males(78.4%)and 8 females(21.6%),with a mean age of(70.5 ± 9.5)years. Tumor characteristics were maximum diameter ≥ 30 mm in 23(62.2%),< 30 mm in 14(37.8%),multiple tumors in 9(24.3%),solitary in 28(75.7%),pedunculated morphology in 7(18.9%)and non-pedunculated in 30(81.1%). Histological grading identified high-grade tumors in 36 patients(97.3%)and low-grade tumors in 1(2.7%). Pathological staging comprised 1 patient of T a(2.7%),9 of T 1(24.3%),7 of T 2(18.9%),19 of T 3(51.4%),and 1 of T 4(2.7%). In this validation cohort,no significant differences were found in gender,age,tumor multiplicity,or pedunculated morphology between the PUC and VUC subgroups( P > 0.05). Significant differences were observed in pathological grade,pathological stage,and maximum tumor diameter( P < 0.05). Three radiologists independently reviewed and scored the multiparametric MRI(mp-MRI)in a blinded manner. Inter-reader agreement was assessed using the weighted kappa statistic. Differences in variables between the two groups were compared using t-tests,chi-square tests,or Fisher’s exact test. The diagnostic performance of VI-RADS for muscle invasion in VUC and PUC was comprehensively evaluated using receiver operating characteristic(ROC)curves,the area under the curve(AUC),and cut-off values determined by the Youden’s index. The DeLong test was used to assess whether the diagnostic performance of VI-RADS differed between VUC and PUC. Results:In the retrospective single-center cohort,the AUC of VI-RADS for assessing muscle invasion was 0.895(95% CI 0.864?0.922)in the PUC group,with a cut-off value of > 3,and the AUC was 0.896(95% CI 0.791-0.960)in the VUC group,with a cut-off value of > 3. The difference between the two groups was not statistically significant( P = 0.986). Using a VI-RADS score > 3 as the cut-off value,the accuracy,sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NPV)for diagnosing muscle invasion status in the PUC group were 85.8%(392/457),70.5%(98/139),92.5%(294/318),80.3%(98/122),and 87.8%(294/335),respectively. The corresponding values for the VUC group were 82.0%(50/61),76.7%(33/43),94.4%(17/18),97.1%(33/34),and 63.0%(17/27).In the retrospective multicenter cohort,the AUC of VI-RADS for assessing muscle invasion was 0.891(95% CI 0.845?0.927)in the PUC group,with a cut-off value of > 2,and the AUC was 0.898(95% CI 0.754?0.973)in the VUC group,with a cut-off value of > 3. The difference between the two groups was not statistically significant( P = 0.897). Using a VI-RADS score > 3 as the cut-off value,the accuracy,sensitivity,specificity,PPV,and NPV for diagnosing muscle invasion status in the PUC group were 85.9%(207/241),58.9%(33/56),94.1%(174/185),75.0%(33/44),and 88.3%(174/197),respectively. The corresponding values for the VUC group were 81.1%(30/37),77.8%(21/27),90.0%(9/10),95.5%(21/22),and 60.0%(9/15).In the single-center cohort,the Kappa values for inter-reader agreement in assessing muscle invasion status using VI-RADS were 0.881( P < 0.01)for the PUC group and 0.941( P < 0.01)for the VUC group among the three readers. In the multicenter cohort,the Kappa values were 0.858( P < 0.01)for the PUC group and 0.838( P < 0.01)for the VUC group. Conclusions:VI-RADS demonstrates similarly high diagnostic performance for assessing muscle invasion in both PUC and VUC,which is applicable for diagnosing muscle invasion status in VUC,and shows good inter-reader agreement.

Result Analysis