1.Diagnostic yield and safety of pancreatic cystic lesions: A comparison between EUS-FNA and EUS-FNB.
Xiaoyu YU ; Mingmei YE ; Yawen NI ; Qianqi LIU ; Pan GONG ; Yuanyuan HUANG ; Xiaoyan WANG ; Li TIAN
Journal of Central South University(Medical Sciences) 2025;50(2):227-236
OBJECTIVES:
In recent years, the incidence and detection rate of pancreatic cystic lesions (PCLs) have increased significantly. Endoscopic ultrasound (EUS) plays an indispensable role in the diagnosis and differential diagnosis of PCLs. However, evidence comparing the diagnostic performance of EUS-guided fine-needle aspiration (EUS-FNA) and fine-needle biopsy (FNB) remains limited. This study aims to compare the diagnostic yield, adequacy of tissue acquisition, and safety between EUS-FNA and EUS-FNB in evaluating PCLs to inform clinical practice.
METHODS:
A retrospective review was conducted on patients with PCLs who underwent either EUS-FNA or EUS-FNB between January 2014 and August 2021. The diagnostic yield, tissue acquisition adequacy, and incidence of adverse events were compared between the 2 groups.
RESULTS:
A total of 90 patients with PCLs were included (52 in the FNA group and 38 in the FNB group). The diagnostic yield was similar between the FNA and FNB groups (94.2% vs 94.7%, P>0.05). The adequacy of tissue acquisition was 71.2% in the FNA group and 81.6% in the FNB group (P>0.05). No statistically significant difference was observed in the incidence of adverse events between the 2 groups (P>0.05).
CONCLUSIONS
Both EUS-FNA and EUS-FNB demonstrate equally high diagnostic yields and tissue adequacy in PCLs, with excellent safety profiles. Both methods are safe and effective diagnostic tools for evaluating PCLs.
Humans
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects*
;
Retrospective Studies
;
Female
;
Male
;
Pancreatic Cyst/diagnostic imaging*
;
Middle Aged
;
Biopsy, Fine-Needle/adverse effects*
;
Aged
;
Pancreatic Neoplasms/diagnosis*
;
Adult
;
Endosonography/methods*
;
Pancreas/pathology*
;
Diagnosis, Differential
2.Updated techniques of guidance in prostatic biopsy puncture.
National Journal of Andrology 2024;30(12):1141-1146
Pathological results are a gold standard for the diagnosis of prostate cancer (PCa), one of the ways to obtain the pathological tissue is prostate biopsy. With the advances in detection technology, biochemical examination and medical imaging have greatly improved the detection rate of PCa. However, the final therapeutic option depends on pathological results, and therefore the precision of prostate biopsy and puncturing technique is highly required. Specific requirements include pinpoint positioning of the lesion and exact sampling of the positive tissue to reduce pain caused by unnecessary invalid punctures, accurate navigation for deep lesions to avoid damage to the urethra and bladder and reduce bleeding and other complications. Current development of medical imaging and artificial intelligence has significantly promoted biopsy puncture techniques. This review updates the application of image fusion and robotics in prostate biopsy.
Humans
;
Male
;
Prostatic Neoplasms/pathology*
;
Prostate/pathology*
;
Image-Guided Biopsy/methods*
;
Punctures/methods*
;
Biopsy, Needle/methods*
;
Robotics
3.Evaluation of accuracy of pathological diagnosis based on thyroid core needle biopsy.
Yan XIONG ; Xin LI ; Li LIANG ; Dong LI ; Li Min YAN ; Xue Ying LI ; Ji Ting DI ; Ting LI
Journal of Peking University(Health Sciences) 2023;55(2):234-242
OBJECTIVE:
To explore the protocol for diagnosing thyroid nodules based on core needle biopsy (CNB) and study the biomarkers' application in distinguishing indeterminate samples.
METHODS:
Patients with thyroid nodules treated at Peking University First Hospital from 2015 to 2020 were reviewed. In the study, 598 cases with CNB and matched resected specimens were retrieved. According to "diagnostic categories of thyroid CNB" proposed by the Korean Endocrine Pathology Thyroid Core Needle Biopsy Study Group, the CNB samples were diagnosed as follows: Ⅰ, unsatisfactory; Ⅱ, benign; Ⅲ, indeterminate; Ⅳ, follicular neoplasm; Ⅴ, suspicious for malignancy; and Ⅵ, malignant. The samples of CNB Ⅲ were stained by immunohistochemistry (IHC) using antibodies against CK19, Galectin-3, HBME-1, and CD56, and detected by next-generation sequencing (NGS) using an OncoAim® thyroid cancer multigene assay kit (Singlera Genomics) that detected 26 genes. Taking the resected specimens' classification as the gold standard, the predictive value of CNB for determining the malignancy of thyroid nodules and the biomarkers for distinguishing the samples of CNB Ⅲ was calculated.
RESULTS:
The study included 598 patients, of which none were CNB Ⅰ, 40 cases were CNB Ⅱ, 40 cases were CNB Ⅲ, 32 cases were CNB Ⅳ, 35 cases were CNB Ⅴ, and 451 cases were CNB Ⅵ. The predictive value of CNB Ⅳ for determining follicular neoplasm was sensitivity (Sen) 100.00% and specificity (Sep) 100.00%, CNB Ⅴ-Ⅵ for determining malignancy was Sen 94.55% and Sep 100.00%, CNB Ⅱ for determining benign lesions was Sen 75.00% and Sep 99.80%. The predictive value of biomarkers for determining malignancy in cases of CNB Ⅲ was Sen 96.30% and Sep 92.31% by NGS, and Sen 81.48% and Sep 92.30% by IHC.
CONCLUSION
The Korean "diagnostic categories of thyroid CNB", which considers the histological specificity of CNB samples and the habits of clinicians, have strong operability, high diagnosis rate, and high clinical value. Under this framework, the cases of CNB Ⅵ should be treated with surgical operation, the cases of CNB Ⅴ-Ⅵ are recommended to be treated as malignant neoplasms, and the major cases of CNB Ⅱ could be followed up without worrisome except the one considered malignant by ultrasound. The value of biomarkers in distinguishing the cases of CNB Ⅲ is significant.
Humans
;
Thyroid Nodule/surgery*
;
Biopsy, Large-Core Needle/methods*
;
Thyroid Neoplasms/surgery*
;
Biomarkers
4.Application of Rapid HE Staining in Cytological Rapid On-site Evaluation of Peripheral Lung Cancer Needle Biopsy.
Jian HE ; Guilan XIA ; Shiping WANG ; Kun CHEN
Chinese Journal of Lung Cancer 2023;26(8):572-578
BACKGROUND:
Rapid on-site evaluation (ROSE) is a technique used for simultaneous evaluation of biopsy specimens through rapid cytology staining. Diff-Quik (DQ) staining is the most commonly employed method for cytological rapid on-site evaluation (C-ROSE). However, the utilization of DQ staining for on-site cytological interpretation remains uncommon among pathologists in China, posing challenges to the implementation of C-ROSE. This study aims to assess the application of rapid hematoxylin-eosin (HE) staining and DQ staining for C-ROSE during percutaneous needle biopsy of peripheral lung cancer and evaluate the value of rapid HE staining in C-ROSE.
METHODS:
Computed tomography (CT)-guided lung biopsies were conducted on 300 patients diagnosed with peripheral lung cancer. The patients were randomly assigned to two groups for C-ROSE using either rapid HE staining or DQ staining, and subsequently the two methods were compared and evaluated.
RESULTS:
The concordance rate between C-ROSE and histopathological diagnosis was 96.7%. The median staining time for rapid HE staining was 160 s, while that for DQ staining was 120 s, representing a significant difference between the two groups (P<0.001). However, there were no significant differences observed in terms of total biopsy time, concordance rate with histopathology, cytology specimen peeling rate, and incidence of serious adverse reactions between the two groups (P>0.05).
CONCLUSIONS
Both staining methods comply with C-ROSE criteria in the biopsy setting of peripheral lung cancer. Rapid HE staining is more aligned with domestic clinical requirements and holds potential for further promotion and adoption in C-ROSE.
Humans
;
Lung Neoplasms/pathology*
;
Eosine Yellowish-(YS)
;
Rapid On-site Evaluation
;
Biopsy, Needle/methods*
;
Staining and Labeling
5.Influencing Factors of Bethesda Ⅲ Results in Fine-Needle Aspiration Biopsy of Thyroid Nodules.
Jian LIU ; Shang-Hong XIE ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(6):929-933
Objective To investigate the influencing factors of Bethesda Ⅲ results in fine-needle aspiration biopsy of thyroid nodules.Methods A total of 300 thyroid nodules with cytological diagnosis results were analyzed retrospectively,including 100 Bethesda Ⅲ nodules and 50 nodules of Bethesda Ⅱ,Ⅳ,Ⅴ,and Ⅵ categories,respectively.Univariate analysis and Logistic regression analysis were performed on the clinical data of patients and the ultrasound signs of thyroid nodules to clarify the factors influencing the diagnosis of Bethesda Ⅲ nodules.Results Univariate analysis showed that Bethesda Ⅲ nodules were mostly adjacent to the capsule(P<0.001),with no blood flow in the color Doppler assessment(P=0.011)and lack of blood supply(P=0.033)and maximum diameter ≤0.9 cm(P=0.038)as revealed by the contrast-enhanced ultrasound.Logistic regression showed that the position close to the capsule(OR=5.110,95%CI=2.153-12.130,P<0.001)and color Doppler without blood flow signal(OR=3.015,95%CI=1.094-8.311,P=0.033)were independent risk factors for the diagnosis of Bethesda Ⅲ nodules.Conclusions The puncture difficulty caused by the dangerous position of thyroid nodules close to the capsule and the aspiration difficulty caused by the absence of blood flow signal in color Doppler are the main factors influencing the diagnosis of Bethesda Ⅲ nodules.Therefore,corresponding avoidance measures should be taken during the aspiration process to reduce the diagnosis results of Bethesda Ⅲ nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Thyroid Neoplasms/diagnosis*
;
Biopsy, Fine-Needle/methods*
;
Retrospective Studies
;
Ultrasonography/methods*
6.Influencing Factors and Prediction Model of Performance of Needle Visualization in Fine Needle Aspiration of Thyroid Nodules.
Liang-Kai WANG ; Jia-Jia TANG ; Wen-Quan NIU ; Xin-Ying JIA ; Xue-Hua XI ; Jiao-Jiao MA ; Hui-Lin LI ; Zhe SUN ; Xin-Yi LIU ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):366-373
Objective To investigate the influencing factors and establish a model predicting the performance of needle visualization in fine-needle aspiration (FNA) of thyroid nodules. Methods This study prospectively included 175 patients who underwent FNA of thyroid nodules in the Department of Ultrasound in China-Japan Friendship Hospital and compared the display of the needle tips in the examination of 199 thyroid nodules before and after the application of needle visualization.We recorded the location,the positional relationship with thyroid capsule,ultrasonic characteristics,and the distribution of the soft tissue strip structure at the puncture site of the nodules with unclear needle tips display before using needle visualization.Furthermore,according to the thyroid imaging reporting and data system proposed by the American College of Radiology,we graded the risk of the nodules.Lasso-Logistic regression was employed to screen out the factors influencing the performance of needle visualization and establish a nomogram for prediction. Results The needle tips were not clearly displayed in the examination of 135 (67.8%) and 53 (26.6%) nodules before and after the application of needle visualization,respectively,which showed a significant difference (P<0.001).Based on the positional relationship between the nodule and capsule,anteroposterior/transverse diameter (A/T) ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site,a nomogram was established to predict the probability of unclear display of the needle tips after application of needle visualization.The C-index of the prediction model was 0.75 (95%CI=0.67-0.84) and the area under the receiver operating characteristic curve was 0.72.The calibration curve confirmed the appreciable reliability of the prediction model,with the C-index of 0.70 in internal validation. Conclusions Needle visualization can improve the display of the needle tip in ultrasound-guided FNA of thyroid nodules.The nomogram established based on ultrasound features such as the positional relationship between the nodule and capsule,A/T ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site can predict whether needle visualization is suitable for the examination of nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Biopsy, Fine-Needle/methods*
;
Reproducibility of Results
;
Ultrasonography
;
Retrospective Studies
;
Thyroid Neoplasms
7.Recent advances in diagnosis of pulmonary nodule.
Chinese Journal of Surgery 2022;60(5):498-503
With the popularization of health screening and the widespread use of low-dose computed tomography, the detection rate of lung nodules has increased year after year. However, the false positive rates testified by surgery of these lung nodules are still high. Therefore, it is vital in clinical practice to avoid overtreatment or undertreatment. But a series of problems on how to make an accurate diagnosis, how to reduce the psychological pressure of patients and follow up with regular imaging, how to clarify the indications for surgery and adopt the most minimally invasive diagnosis and treatment methods, etc. remain unsolved. Over the past decade, the diagnostic techniques for pulmonary nodules have improved significantly, including imaging progress such as the optimization of traditional imaging techniques (CT, MRI) and the emergence of new technologies (radiomics, artificial intelligence). In addition, histological improvements including percutaneous transthoracic needle biopsy, bronchoscopy, and minimally invasive surgical biopsy, etc. have brought more reliable and precise options for characterization of pulmonary nodules.
Artificial Intelligence
;
Biopsy, Needle/methods*
;
Bronchoscopy
;
Humans
;
Lung Neoplasms/diagnosis*
;
Tomography, X-Ray Computed
8.Analysis of 53 cases of transjugular liver biopsy.
Lei WANG ; Zhen Dong YUE ; Hong Wei ZHAO ; Zhen Hua FAN ; Yi Fan WU ; Yu ZHANG ; Rui Zhao QI ; Ke ZHANG ; Li JIANG ; Hui Guo DING ; Yue Ning ZHANG ; Fu Quan LIU
Chinese Journal of Hepatology 2022;30(2):220-223
Objective: To investigate the practicability and safety of transjugular liver biopsy (TJLB). Methods: Data of 53 cases with transjugular liver biopsy from June 2015 to June 2020 were collected. LABS-100 was used in all patients who underwent transjugular liver biopsy. Among them, 45 cases and eight were biopsied via hepatic vein and intrahepatic segment of the inferior vena cava. The surgical indications, related complications, and postoperative pathological diagnosis were analyzed and summarized. Results: TJLB was successful in all patients, with an average of 2.8 punctures per case. Satisfactory liver tissue and histopathological diagnosis was obtained in all patients. Two cases developed a cervical hematoma that was improved spontaneously, and one patient developed an intrahepatic hematoma that was improved after conservative treatment. Conclusion: TJLB is a practical and safe method for patients with contraindications to percutaneous liver biopsy.
Biopsy/methods*
;
Biopsy, Needle/methods*
;
Humans
;
Jugular Veins
;
Liver Diseases/pathology*
9.Core-Needle Biopsy Does Not Show Superior Diagnostic Performance to Fine-Needle Aspiration for Diagnosing Thyroid Nodules
Ilah SHIN ; Eun Kyung KIM ; Hee Jung MOON ; Jung Hyun YOON ; Vivian Youngjean PARK ; Si Eun LEE ; Hye Sun LEE ; Jin Young KWAK
Yonsei Medical Journal 2020;61(2):161-168
needle aspiration (FNA) and core-needle biopsy (CNB) for thyroid nodules according to nodule size.MATERIALS AND METHODS: This retrospective study included 320 thyroid nodules from 320 patients who underwent both FNA and CNB at outside clinics and proceeded with surgery in our institution between July 2012 and May 2019. According to nodule size, the diagnostic performances of FNA and CNB were calculated using various combinations of test-negatives and test-positives defined by the Bethesda categories and were compared using the generalized estimated equation and the Delong method.RESULTS: There were 279 malignant nodules in 279 patients and 41 benign nodules in 41 patients. The diagnostic performance of FNA was mostly not different from CNB regardless of nodule size, except for negative predictive value, which was better for FNA than CNB when applying Criteria 1 and 2. When applying Criteria 3, the specificity and positive predictive value of FNA were superior to CNB regardless of size. When applying Criteria 4, diagnostic performance did not differ between FNA and CNB regardless of size. After applying Criteria 5, diagnostic performance did not differ between FNA and CNB in nodules ≥2 cm. However, in nodules ≥1 cm and all nodules, the sensitivity, accuracy, and negative predictive value of CNB were better than those of FNA.CONCLUSION: CNB did not show superior diagnostic performance to FNA for diagnosing thyroid nodules.]]>
Biopsy
;
Biopsy, Fine-Needle
;
Biopsy, Large-Core Needle
;
Humans
;
Methods
;
Retrospective Studies
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
10.Present and Future of Endoscopic Ultrasound-Guided Tissue Acquisition in Solid Pancreatic Tumors
Jae Keun PARK ; Kwang Hyuck LEE
Clinical Endoscopy 2019;52(6):541-548
Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is a well-established method for pathological diagnosis of solid pancreatic neoplasm. It can be performed either as EUS-guided fine-needle aspiration (EUS-FNA) or EUS-guided fine-needle biopsy (EUS-FNB). The incidence of adverse events related to EUS-TA is less than 1%. The factors that affect the diagnostic accuracy and specimen adequacy include the techniques used, type and size of the needle, competency of endosonographers, presence of cytopathologists/cytotechnologists, and rapid on-site examination. EUS-TA may contribute to precision medicine through obtaining tissue samples for next-generation sequencing. The current status, several clinical issues for diagnostic yield and adverse events, and future perspectives of EUS-FNA/FNB for diagnosing pancreatic neoplasm have been discussed in this review article.
Biopsy, Fine-Needle
;
Diagnosis
;
Incidence
;
Methods
;
Needles
;
Pancreatic Neoplasms
;
Precision Medicine

Result Analysis
Print
Save
E-mail