1.Biomechanical parameters assessed during running among running-related athletes with recurrent hamstring strain injury: A scoping review
Reil Vinard Espino ; Consuelo Suarez ; Lewis Ingram ; Donald Manlapaz ; Kris Anthony Agarao
Philippine Journal of Allied Health Sciences 2024;7(2):9-27
Background:
Hamstring strain injury (HSI) is the most common cause of missing practices and sporting events among running-related athletes.
The incidence rate of recurrence in individuals with HSI ranges from 12% to 63%. While various risk factors for HSI have been identified, the
alterations and role of biomechanical factors as potential causes of injury have been largely overlooked.
Objectives:
To report the critical biomechanical parameters assessed among running-related athletes with a recurrent HSI and to present common testing protocols in assessing the biomechanical parameters among running-related athletes with a recurrent HSI.
Methods:
Eligibility Criteria: Included studies investigated biomechanical parameters assessed among collegiate or elite running-related athletes with recurrent HSI. Sources of Evidence: This scoping review was registered in OSF and was conducted based on PRISMA-ScR. Six electronic databases were systematically searched from 1993 to May 2022. Charting Methods: The reviewers created a data charting tool for the scoping review.
Results:
Out of 874 articles, a total of 10 articles were
included in the scoping review. The critical biomechanical parameters assessed include trunk flexion, hip flexion, and knee extension angles
(kinematic variables), flight and stance times and velocity (spatiotemporal variables), and EMG activity of biceps femoris, semitendinosus,
semimembranosus, vastus lateralis, and rectus femoris, knee flexion and extension angle peak joint torque (kinetic variables). The most common
running test protocols used were the 30-meter overground repeated sprint test, a percentage of maximum running velocity (treadmill), and
repeated sprints on a non-motorized treadmill. The most common protocols for isokinetic muscle testing were 60 degrees (concentric), 300 degrees
(concentric), and 180 degrees (eccentric) per second angular velocities.
Conclusion
The review demonstrated a need for more research on this
topic, leading to only limited biomechanical parameters being discussed in the literature. This underscores the need for more rigorous research
that could have practical applications for athletes and coaches.
Biomechanical Phenomena
;
Athletes
2.Study on injectable chitosan hydrogel with tendon-derived stem cells for enhancing rotator cuff tendon-to-bone healing.
Huawei WEN ; Qingsong ZHANG ; Ming TANG ; Ya'nan LI ; Hongfei TAN ; Yushun FANG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):91-98
OBJECTIVE:
To explore the effect of chitosan (CS) hydrogel loaded with tendon-derived stem cells (TDSCs; hereinafter referred to as TDSCs/CS hydrogel) on tendon-to-bone healing after rotator cuff repair in rabbits.
METHODS:
TDSCs were isolated from the rotator cuff tissue of 3 adult New Zealand white rabbits by Henderson step-by-step enzymatic digestion method and identified by multidirectional differentiation and flow cytometry. The 3rd generation TDSCs were encapsulated in CS to construct TDSCs/CS hydrogel. The cell counting kit 8 (CCK-8) assay was used to detect the proliferation of TDSCs in the hydrogel after 1-5 days of culture in vitro, and cell compatibility of TDSCs/CS hydrogel was evaluated by using TDSCs alone as control. Another 36 adult New Zealand white rabbits were randomly divided into 3 groups ( n=12): rotator cuff repair group (control group), rotator cuff repair+CS hydrogel injection group (CS group), and rotator cuff repair+TDSCs/CS hydrogel injection group (TDSCs/CS group). After establishing the rotator cuff repair models, the corresponding hydrogel was injected into the tendon-to-bone interface in the CS group and TDSCs/CS group, and no other treatment was performed in the control group. The general condition of the animals was observed after operation. At 4 and 8 weeks, real-time quantitative PCR (qPCR) was used to detect the relative expressions of tendon forming related genes (tenomodulin, scleraxis), chondrogenesis related genes (aggrecan, sex determining region Y-related high mobility group-box gene 9), and osteogenesis related genes (alkaline phosphatase, Runt-related transcription factor 2) at the tendon-to-bone interface. At 8 weeks, HE and Masson staining were used to observe the histological changes, and the biomechanical test was used to evaluate the ultimate load and the failure site of the repaired rotator cuff to evaluate the tendon-to-bone healing and biomechanical properties.
RESULTS:
CCK-8 assay showed that the CS hydrogel could promote the proliferation of TDSCs ( P<0.05). qPCR results showed that the expressions of tendon-to-bone interface related genes were significantly higher in the TDSCs/CS group than in the CS group and control group at 4 and 8 weeks after operation ( P<0.05). Moreover, the expressions of tendon-to-bone interface related genes at 8 weeks after operation were significantly higher than those at 4 weeks after operation in the TDSCs/CS group ( P<0.05). Histological staining showed the clear cartilage tissue and dense and orderly collagen formation at the tendon-to-bone interface in the TDSCs/CS group. The results of semi-quantitative analysis showed that compared with the control group, the number of cells, the proportion of collagen fiber orientation, and the histological score in the TDSCs/CS group increased, the vascularity decreased, showing significant differences ( P<0.05); compared with the CS group, the proportion of collagen fiber orientation and the histological score in the TDSCs/CS group significantly increased ( P<0.05), while there was no significant difference in the number of cells and vascularity ( P>0.05). All samples in biomechanical testing failed at the repair site during the testing process. The ultimate load of the TDSCs/CS group was significantly higher than that of the control group ( P<0.05), but there was no significant difference compared to the CS group ( P>0.05).
CONCLUSION
TDSCs/CS hydrogel can induce cartilage regeneration to promote rotator cuff tendon-to-bone healing.
Rabbits
;
Animals
;
Rotator Cuff/surgery*
;
Chitosan
;
Hydrogels
;
Rotator Cuff Injuries/surgery*
;
Wound Healing
;
Tendons/surgery*
;
Collagen
;
Stem Cells
;
Biomechanical Phenomena
3.Research progress on biomechanics for internal fixation in tibial plateau fracture.
Jialun LIU ; Yingze ZHANG ; Zhanle ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):113-118
OBJECTIVE:
To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.
METHODS:
The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.
RESULTS:
Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.
CONCLUSION
Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
Humans
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal
;
Fracture Fixation, Intramedullary
;
Tibial Fractures/surgery*
;
Tibial Plateau Fractures
4.Study on gene therapy for DPOAE and ABR threshold changes in adult Otof-/- mice.
Zijing WANG ; Qi CAO ; Shaowei HU ; Xintai FAN ; Jun LV ; Hui WANG ; Wuqing WANG ; Huawei LI ; Yilai SHU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2024;38(1):49-56
Objective:This study aims to analyze the threshold changes in distortion product otoacoustic emissions(DPOAE) and auditory brainstem response(ABR) in adult Otof-/- mice before and after gene therapy, evaluating its effectiveness and exploring methods for assessing hearing recovery post-treatment. Methods:At the age of 4 weeks, adult Otof-/- mice received an inner ear injection of a therapeutic agent containing intein-mediated recombination of the OTOF gene, delivered via dual AAV vectors through the round window membrane(RWM). Immunofluorescence staining assessed the proportion of inner ear hair cells with restored otoferlin expression and the number of synapses.Statistical analysis was performed to compare the DPOAE and ABR thresholds before and after the treatment. Results:AAV-PHP. eB demonstrates high transduction efficiency in inner ear hair cells. The therapeutic regimen corrected hearing loss in adult Otof-/- mice without impacting auditory function in wild-type mice. The changes in DPOAE and ABR thresholds after gene therapy are significantly correlated at 16 kHz. Post-treatment,a slight increase in DPOAE was observeds,followed by a recovery trend at 2 months post-treatment. Conclusion:Gene therapy significantly restored hearing in adult Otof-/- mice, though the surgical delivery may cause transient hearing damage. Precise and gentle surgical techniques are essential to maximize gene therapy's efficacy.
Mice
;
Animals
;
Otoacoustic Emissions, Spontaneous/physiology*
;
Hearing/physiology*
;
Ear, Inner
;
Hearing Loss/therapy*
;
Genetic Therapy
;
Auditory Threshold/physiology*
;
Evoked Potentials, Auditory, Brain Stem/physiology*
;
Membrane Proteins
5.Macroscopic and mesoscopic biomechanical analysis of the bone unit in idiopathic scoliosis.
Zhaoyao WANG ; Rongchang FU ; Yuan MA ; Peng YE
Journal of Biomedical Engineering 2023;40(2):303-312
To investigate the effects of postoperative fusion implantation on the mesoscopic biomechanical properties of vertebrae and bone tissue osteogenesis in idiopathic scoliosis, a macroscopic finite element model of the postoperative fusion device was developed, and a mesoscopic model of the bone unit was developed using the Saint Venant sub-model approach. To simulate human physiological conditions, the differences in biomechanical properties between macroscopic cortical bone and mesoscopic bone units under the same boundary conditions were studied, and the effects of fusion implantation on bone tissue growth at the mesoscopic scale were analyzed. The results showed that the stresses in the mesoscopic structure of the lumbar spine increased compared to the macroscopic structure, and the mesoscopic stress in this case is 2.606 to 5.958 times of the macroscopic stress; the stresses in the upper bone unit of the fusion device were greater than those in the lower part; the average stresses in the upper vertebral body end surfaces were ranked in the order of right, left, posterior and anterior; the stresses in the lower vertebral body were ranked in the order of left, posterior, right and anterior; and rotation was the condition with the greatest stress value in the bone unit. It is hypothesized that bone tissue osteogenesis is better on the upper face of the fusion than on the lower face, and that bone tissue growth rate on the upper face is in the order of right, left, posterior, and anterior; while on the lower face, it is in the order of left, posterior, right, and anterior; and that patients' constant rotational movements after surgery is conducive to bone growth. The results of the study may provide a theoretical basis for the design of surgical protocols and optimization of fusion devices for idiopathic scoliosis.
Humans
;
Scoliosis/surgery*
;
Spinal Fusion/methods*
;
Lumbar Vertebrae/surgery*
;
Osteogenesis
;
Biomechanical Phenomena/physiology*
;
Finite Element Analysis
6.A gait signal acquisition and parameter characterization method based on foot pressure detection combined with Azure Kinect system.
Guofeng XU ; Kai CHEN ; Ying YANG
Journal of Biomedical Engineering 2023;40(2):350-357
The gait acquisition system can be used for gait analysis. The traditional wearable gait acquisition system will lead to large errors in gait parameters due to different wearing positions of sensors. The gait acquisition system based on marker method is expensive and needs to be used by combining with the force measurement system under the guidance of rehabilitation doctors. Due to the complex operation, it is inconvenient for clinical application. In this paper, a gait signal acquisition system that combines foot pressure detection and Azure Kinect system is designed. Fifteen subjects are organized to participate in gait test, and relevant data are collected. The calculation method of gait spatiotemporal parameters and joint angle parameters is proposed, and the consistency analysis and error analysis of the gait parameters of proposed system and camera marking method are carried out. The results show that the parameters obtained by the two systems have good consistency (Pearson correlation coefficient r ≥ 0.9, P < 0.05) and have small error (root mean square error of gait parameters is less than 0.1, root mean square error of joint angle parameters is less than 6). In conclusion, the gait acquisition system and its parameter extraction method proposed in this paper can provide reliable data acquisition results as a theoretical basis for gait feature analysis in clinical medicine.
Humans
;
Biomechanical Phenomena
;
Gait
;
Lower Extremity
;
Foot
;
Gait Analysis
;
Reproducibility of Results
7.Research progress in biomechanics of Bristow-Latarjet procedure for anterior shoulder dislocation.
Shuhan ZHANG ; Min ZHANG ; Zhenxing SHAO ; Guoqing CUI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):518-525
OBJECTIVE:
To review the research progress of the biomechanical study of the Bristow-Latarjet procedure for anterior shoulder dislocation.
METHODS:
The related biomechanical literature of Bristow-Latarjet procedure for anterior shoulder dislocation was extensively reviewed and summarized.
RESULTS:
The current literature suggests that when performing Bristow-Latarjet procedure, care should be taken to fix the bone block edge flush with the glenoid in the sagittal plane in the direction where the rupture of the joint capsule occurs. If traditional screw fixation is used, a double-cortical screw fixation should be applied, while details such as screw material have less influence on the biomechanical characteristics. Cortical button fixation is slightly inferior to screws in terms of biomechanical performance. The most frequent site of postoperative bone resorption is the proximal-medial part of the bone block, and the cause of bone resorption at this site may be related to the stress shielding caused by the screw.
CONCLUSION
There is no detailed standardized guidance for bone block fixation. The optimal clinical treatment plan for different degrees of injury, the factors influencing postoperative bone healing and remodeling, and the postoperative osteoarticular surface pressure still need to be further clarified by high-quality biomechanical studies.
Humans
;
Shoulder Dislocation/surgery*
;
Shoulder Joint/surgery*
;
Biomechanical Phenomena
;
Joint Instability/surgery*
;
Bone Resorption
;
Arthroscopy/methods*
8.Three-dimensional kinematic analysis of knee joint after anterior cruciate ligament reconstruction with personalized femoral positioner based on apex of deep cartilage.
Renjie HE ; Ziwen NING ; Zhengliang SHI ; Ziming GU ; Yanlin LI ; Guoliang WANG ; Chuan HE
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):663-669
OBJECTIVE:
To investigate the changes of knee joint kinematics after anterior cruciate ligament (ACL) reconstruction assisted by personalized femoral positioner based on the apex of deep cartilage (ADC).
METHODS:
Between January 2021 and January 2022, a total of 40 patients with initial ACL rupture who met the selection criteria were randomly divided into the study group (using the personalized femoral positioner based on ADC design to assist ACL reconstruction) and the control group (not using the personalized femoral positioner to assist ACL reconstruction), with 20 patients in each group. Another 20 volunteers with normal knee were collected as a healthy group. There was no significant difference in gender, age, body mass index, and affected side between groups ( P>0.05). Gait analysis was performed at 3, 6, and 12 months after operation using Opti _ Knee three-dimensional knee joint motion measurement and analysis system, and the 6 degrees of freedom (flexion and extension angle, varus and valgus angle, internal and external rotation angle, anteroposterior displacement, superior and inferior displacement, internal and external displacement) and motion cycle (maximum step length, minimum step length, and step frequency) of the knee joint were recorded. The patients' data was compared to the data of healthy group.
RESULTS:
In the healthy group, the flexion and extension angle was (57.80±3.45)°, the varus and valgus angle was (10.54±1.05)°, the internal and external rotation angle was (13.02±1.66)°, and the anteroposterior displacement was (1.44±0.39) cm, the superior and inferior displacement was (0.86±0.20) cm, and the internal and external displacement was (1.38±0.39) cm. The maximum step length was (51.24±1.29) cm, the minimum step length was (45.69±2.28) cm, and the step frequency was (12.45±0.47) step/minute. Compared with the healthy group, the flexion and extension angles and internal and external rotation angles of the patients in the study group and the control group decreased at 3 months after operation, and the flexion and extension angles of the patients in the control group decreased at 6 months after operation, and the differences were significant ( P<0.05); there was no significant difference in the other time points and other indicators when compared with healthy group ( P>0.05). In the study group, the flexion and extension angles and internal and external rotation angles at 6 and 12 months after operation were significantly greater than those at 3 months after operation ( P<0.05), while there was no significant difference in the other indicators at other time points ( P>0.05). There was a significant difference in flexion and extension angle between the study group and the control group at 6 months after operation ( P<0.05), but there was no significant difference of the indicators between the two groups at other time points ( P>0.05).
CONCLUSION
Compared with conventional surgery, ACL reconstruction assisted by personalized femoral positioner based on ADC design can help patients achieve more satisfactory early postoperative kinematic results, and three-dimensional kinematic analysis can more objectively and dynamically evaluate the postoperative recovery of knee joint.
Humans
;
Biomechanical Phenomena
;
Knee Joint/surgery*
;
Femur/surgery*
;
Anterior Cruciate Ligament Injuries/surgery*
;
Range of Motion, Articular
;
Cartilage/surgery*
;
Anterior Cruciate Ligament Reconstruction/methods*
9.Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis.
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):688-693
OBJECTIVE:
The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.
METHODS:
Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.
RESULTS:
In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).
CONCLUSION
Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.
Humans
;
Female
;
Aged
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/surgery*
;
Bone Plates
;
Femur Head
;
Femoral Fractures/surgery*
10.Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis.
Bin WANG ; Xingbo CAI ; Yue ZHANG ; Bihuan ZHANG ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):821-826
OBJECTIVE:
To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.
METHODS:
One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.
RESULTS:
The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.
CONCLUSION
The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.
Humans
;
Lunate Bone/surgery*
;
Finite Element Analysis
;
Titanium
;
Wrist Joint/surgery*
;
Artificial Limbs
;
Range of Motion, Articular
;
Biomechanical Phenomena


Result Analysis