1.Distribution characteristics of polymorphonuclear neutrophil pulmonary infiltration and the mechanism of neutrophil elastase in promoting lung injury in the early stages of severe burns.
Xin ZHANG ; Chunfang ZHENG ; Jiahui CHEN ; Zaiwen GUO ; Linbin LI ; Jiamin HUANG ; Bingwei SUN
Chinese Critical Care Medicine 2025;37(5):431-437
OBJECTIVE:
To investigate the distribution characteristics of polymorphonuclear neutrophil (PMN) in the lungs during the early stage of severe burns and the mechanism of neutrophil elastase (NE) promoting lung injury.
METHODS:
6-8-week-old male C57BL/6J mice were selected for the experiments. A 30% total body surface area (TBSA) III degree burn mouse model was established (severe burn group); the Sham-injury group was treated with 37 centigrade water. In the sodium sivelestat intervention group (SV intervention group), NE competitive inhibitor, sivelestat, 100 mg/kg, was injected via tail vein immediately after injury, while other groups received an equal volume of saline. Ten mice were harvested from each group to observe survival for 72 hours. Respiratory function tests were tested at 0 (immediate), 3, 6, 12, and 24 hours after molding. hematoxylin-eosin (HE) and immunohistochemical staining were used to observe lung tissue structure, inflammatory changes and PMN infiltration. The PMN absolute count in mice lung tissue was detected buy flow cytometry. At 6, 12, and 24 hours after molding, PMN counts and the concentration of NE [enzyme linked immunosorbent assay (ELISA)] in peripheral blood plasma, lung tissue, and bronchoalveolar lavage fluid (BALF) were detected.
RESULTS:
(1) HE staining results showed that compared with the Sham-injury group, the lungs of mice in the severe burn group showed inflammatory changes and PMN infiltration, with more significant changes at 6 hours. Immunohistochemistry results also confirmed that the expression of NE protein released from PMN significantly increased after 6 hours of severe burn injury [(3.79±0.62)% vs. (0.18±0.05)%, t = 11.56, P < 0.01]. (2) Compared with the Sham-injury group, the number of PMN and the concentration of NE in the peripheral blood and lung tissues in the severe burn group were significantly increased (F values were 13.709, 55.350 and 29.890, 13.286, respectively, all P < 0.01), peaking at 6 hours [plasma PMN count (×109/L): 2.92±1.01 vs. 0.92±0.29, lung tissue PMN absolute count (cells): 48 788.03±11 833.91 vs. 1 516.72±415.35, plasma NE (ng/L): 24 522.71±3 842.92 vs. 7 009.34±4 067.86, lung tissue NE (ng/L): 262 189.04±9 695.13 vs. 65 026.03± 16 016.31, all P < 0.01]. The number of PMN in the lung of severely burned mice was highly correlated with NE concentration (r = 0.892, P < 0.001). There was no significantly difference in the PMN absolute count in the BALF of mice between the Sham-injury group and severe burn group (F = 1.403, P > 0.05). The Sham-injury group and severe burn group contained a small amount of NE in the BALF, and the concentration of NE in the BALF of the severely burned 6 hours and 12 hours groups were significantly higher than those of the Sham-injury group (ng/L: 328.58±158.10, 415.30±240.89 vs. 61.95±15.80, both P < 0.05). (3) Kaplan-Meier survival curve showed that the 72-hour survival rate of mice in the SV intervention group was significantly higher than that in the severe burn group (100% vs. 10%, Log-Rank test: χ2 = 19.12, P < 0.001). (4) Compared with the Sham-injury group, all lung function indices of the severe burn group decreased significantly. All lung function indices of SV intervention group improved gradually over time, which were significantly better than those of the severe burn group. (5) Compared with the Sham-injury group, the PMN absolute count in lung tissue and the concentration of NE in plasma and lung tissue were significantly higher in the SV intervention group (F values were 46.709, 3.535, 32.701, respectively, all P < 0.05), with a peak at 6 hours. Compared with the severe burn group, the SV intervention group had a higher PMN absolute count in lung tissue (cells: 8 870.80±7 013.89 vs. 25 974.92±22 240.8, P < 0.05), and higher plasma and lung tissue NE concentrations (ng/L: 14 955.94±3 944.41 vs. 21 972.75±4 573.05, 81 956.87±38 658.35 vs. 168 182.30±83 513.91, both P < 0.01) were significantly decreased.
CONCLUSIONS
In the early stage of severe burns, there is a significant infiltration of PMN into the lungs. The NE promotes lung injury in the early stage of severe burn, and improve lung injury by inhibiting the action of NE.
Animals
;
Burns/metabolism*
;
Leukocyte Elastase/metabolism*
;
Male
;
Mice, Inbred C57BL
;
Mice
;
Neutrophils/metabolism*
;
Lung/metabolism*
;
Disease Models, Animal
;
Neutrophil Infiltration
;
Lung Injury/metabolism*
;
Glycine/analogs & derivatives*
;
Sulfonamides
2.A Self-Developed Mobility Augmented Reality System Versus Conventional X-rays for Spine Positioning in Intraspinal Tumor Surgery: A Case-Control Study
Wenyao HONG ; Xiaohua HUANG ; Tian LI ; Juntao LUO ; Yuqing LIU ; Shengyue HUANG ; Zhongyi CHEN ; Bingwei HE ; Yuxing WEN ; Yuanxiang LIN
Neurospine 2024;21(3):984-993
Objective:
To evaluate the efficacy of a self-developed mobile augmented reality navigation system (MARNS) in guiding spinal level positioning during intraspinal tumor surgery based on a dual-error theory.
Methods:
This retrospective study enrolled patients diagnosed with intraspinal tumors admitted to Fujian Provincial Hospital between May and November 2023. The participants were divided into conventional x-rays and self-developed MARNS groups according to the localization methods they received. Position time, length of intraoperative incision variation, and location accuracy were systematically compared.
Results:
A total of 41 patients (19 males) with intraspinal tumors were included, and MARNS was applied to 21 patients. MARNS achieved successful lesion localization in all patients with an error of 0.38±0.12 cm. Compared to x-rays, MARNS significantly reduced positioning time (129.00±13.03 seconds vs. 365.00±60.43 seconds, p<0.001) and length of intraoperative incision variation (0.14 cm vs. 0.67 cm, p=0.009).
Conclusion
The self-developed MARNS, based on augmented reality technology for lesion visualization and perpendicular projection, offers a radiation-free complement to conventional x-rays.
3.A Self-Developed Mobility Augmented Reality System Versus Conventional X-rays for Spine Positioning in Intraspinal Tumor Surgery: A Case-Control Study
Wenyao HONG ; Xiaohua HUANG ; Tian LI ; Juntao LUO ; Yuqing LIU ; Shengyue HUANG ; Zhongyi CHEN ; Bingwei HE ; Yuxing WEN ; Yuanxiang LIN
Neurospine 2024;21(3):984-993
Objective:
To evaluate the efficacy of a self-developed mobile augmented reality navigation system (MARNS) in guiding spinal level positioning during intraspinal tumor surgery based on a dual-error theory.
Methods:
This retrospective study enrolled patients diagnosed with intraspinal tumors admitted to Fujian Provincial Hospital between May and November 2023. The participants were divided into conventional x-rays and self-developed MARNS groups according to the localization methods they received. Position time, length of intraoperative incision variation, and location accuracy were systematically compared.
Results:
A total of 41 patients (19 males) with intraspinal tumors were included, and MARNS was applied to 21 patients. MARNS achieved successful lesion localization in all patients with an error of 0.38±0.12 cm. Compared to x-rays, MARNS significantly reduced positioning time (129.00±13.03 seconds vs. 365.00±60.43 seconds, p<0.001) and length of intraoperative incision variation (0.14 cm vs. 0.67 cm, p=0.009).
Conclusion
The self-developed MARNS, based on augmented reality technology for lesion visualization and perpendicular projection, offers a radiation-free complement to conventional x-rays.
4.A Self-Developed Mobility Augmented Reality System Versus Conventional X-rays for Spine Positioning in Intraspinal Tumor Surgery: A Case-Control Study
Wenyao HONG ; Xiaohua HUANG ; Tian LI ; Juntao LUO ; Yuqing LIU ; Shengyue HUANG ; Zhongyi CHEN ; Bingwei HE ; Yuxing WEN ; Yuanxiang LIN
Neurospine 2024;21(3):984-993
Objective:
To evaluate the efficacy of a self-developed mobile augmented reality navigation system (MARNS) in guiding spinal level positioning during intraspinal tumor surgery based on a dual-error theory.
Methods:
This retrospective study enrolled patients diagnosed with intraspinal tumors admitted to Fujian Provincial Hospital between May and November 2023. The participants were divided into conventional x-rays and self-developed MARNS groups according to the localization methods they received. Position time, length of intraoperative incision variation, and location accuracy were systematically compared.
Results:
A total of 41 patients (19 males) with intraspinal tumors were included, and MARNS was applied to 21 patients. MARNS achieved successful lesion localization in all patients with an error of 0.38±0.12 cm. Compared to x-rays, MARNS significantly reduced positioning time (129.00±13.03 seconds vs. 365.00±60.43 seconds, p<0.001) and length of intraoperative incision variation (0.14 cm vs. 0.67 cm, p=0.009).
Conclusion
The self-developed MARNS, based on augmented reality technology for lesion visualization and perpendicular projection, offers a radiation-free complement to conventional x-rays.
5.A Self-Developed Mobility Augmented Reality System Versus Conventional X-rays for Spine Positioning in Intraspinal Tumor Surgery: A Case-Control Study
Wenyao HONG ; Xiaohua HUANG ; Tian LI ; Juntao LUO ; Yuqing LIU ; Shengyue HUANG ; Zhongyi CHEN ; Bingwei HE ; Yuxing WEN ; Yuanxiang LIN
Neurospine 2024;21(3):984-993
Objective:
To evaluate the efficacy of a self-developed mobile augmented reality navigation system (MARNS) in guiding spinal level positioning during intraspinal tumor surgery based on a dual-error theory.
Methods:
This retrospective study enrolled patients diagnosed with intraspinal tumors admitted to Fujian Provincial Hospital between May and November 2023. The participants were divided into conventional x-rays and self-developed MARNS groups according to the localization methods they received. Position time, length of intraoperative incision variation, and location accuracy were systematically compared.
Results:
A total of 41 patients (19 males) with intraspinal tumors were included, and MARNS was applied to 21 patients. MARNS achieved successful lesion localization in all patients with an error of 0.38±0.12 cm. Compared to x-rays, MARNS significantly reduced positioning time (129.00±13.03 seconds vs. 365.00±60.43 seconds, p<0.001) and length of intraoperative incision variation (0.14 cm vs. 0.67 cm, p=0.009).
Conclusion
The self-developed MARNS, based on augmented reality technology for lesion visualization and perpendicular projection, offers a radiation-free complement to conventional x-rays.
6.A Self-Developed Mobility Augmented Reality System Versus Conventional X-rays for Spine Positioning in Intraspinal Tumor Surgery: A Case-Control Study
Wenyao HONG ; Xiaohua HUANG ; Tian LI ; Juntao LUO ; Yuqing LIU ; Shengyue HUANG ; Zhongyi CHEN ; Bingwei HE ; Yuxing WEN ; Yuanxiang LIN
Neurospine 2024;21(3):984-993
Objective:
To evaluate the efficacy of a self-developed mobile augmented reality navigation system (MARNS) in guiding spinal level positioning during intraspinal tumor surgery based on a dual-error theory.
Methods:
This retrospective study enrolled patients diagnosed with intraspinal tumors admitted to Fujian Provincial Hospital between May and November 2023. The participants were divided into conventional x-rays and self-developed MARNS groups according to the localization methods they received. Position time, length of intraoperative incision variation, and location accuracy were systematically compared.
Results:
A total of 41 patients (19 males) with intraspinal tumors were included, and MARNS was applied to 21 patients. MARNS achieved successful lesion localization in all patients with an error of 0.38±0.12 cm. Compared to x-rays, MARNS significantly reduced positioning time (129.00±13.03 seconds vs. 365.00±60.43 seconds, p<0.001) and length of intraoperative incision variation (0.14 cm vs. 0.67 cm, p=0.009).
Conclusion
The self-developed MARNS, based on augmented reality technology for lesion visualization and perpendicular projection, offers a radiation-free complement to conventional x-rays.
7.Analysis of the diagnosis and treatment of 68 cases of iatrogenic ureteral stricture
Peng ZHANG ; Bingwei HUANG ; Guicao YIN ; Shengqi ZHENG ; Zhe LI ; Shuo QIAO ; Xuesong LI
Journal of Modern Urology 2023;28(7):613-618
【Objective】 To investigate the common etiology, characteristics and treatment of iatrogenic ureteral stricture. 【Methods】 The clinical data of 226 patients with ureteral stricture repaired during May 2019 and Mar. 2022 were retrospectively analyzed, including 68 cases of iatrogenic ureteral stricture. According to the etiology, the patients were divided into urinary group and non-urinary group. 【Results】 There were 42 females and 26 males, aged 25 to 67 (average 49.0±10.4) years. Upper ureteral stricture was detected in 24 (35.3%) cases, who received oral mucosal repair of the ureter. Middle ureteral stricture was detected in 12 (17.6%) cases, who underwent ileal ureterography. Lower ureteral stricture was observed in 24 (35.3%) cases, who were treated with vesical wall flap ureteroplasty. Full-length stricture was observed in 8 (11.8%) cases,who were treated with ileal ureterography. There were significant differences in age, gender, stenosis side, stenosis location and length, surgical methods and types between patients in the urinary group and non-urinary group (P<0.05). During the follow-up of 8 to 20 (average 12.3±5.6) months, the symptoms and renal function of all patients improved, and no recurrence occurred. 【Conclusion】 Invasive endourological surgery is the most common cause of iatrogenic ureteral stenosis. Different treatment strategies should be adopted according to patients’ condition, time of diagnosis and location and length of ureteral injury.
8.Regulatory effects of the Nocardia rubra cell wall skeleton on the biological function of human neutrophils
Yunxi YANG ; Jiamin HUANG ; Lu LIU ; Linbin LI ; Chunfang ZHENG ; Yuying ZHOU ; Bingwei SUN
Chinese Journal of Burns 2023;39(7):625-632
Objective:To investigate the regulatory effects and mechanism of Nocardia rubra cell wall skeleton (Nr-CWS) on the biological function of human neutrophils. Methods:The experimental research method was used. Fifteen healthy adult volunteers (7 males and 8 females, aged 24 to 45 years) were recruited from Suzhou Physical Examination Center for physical examination from May to October 2022, the peripheral venous blood was collected, and neutrophils were extracted by immunomagnetic bead sorting. The cells were divided into normal control group without any treatment, Nr-CWS alone group treated with Nr-CWS of final mass concentration 60 ng/mL alone, endotoxin/lipopolysaccharide (LPS) alone group stimulated with LPS of final mass concentration 1 μg/mL alone, and LPS+Nr-CWS group stimulated with LPS first and then treated with Nr-CWS as before. After 1 h of culture, the chemotaxis distance, chemotactic cell percentage, chemotactic index, maximum chemotactic speed, and chemotactic function score of neutrophils were detected using the modified agarose chemotactic model; the proportion and fluorescence intensity of phagocytosis cells, the level of reactive oxygen species (ROS), the protein expression levels of granular protein CD35, CD66b, and CD63, and the concentrations of inflammatory cytokines of interleukin 2 (IL-2), IL-4, IL-6, IL-10, IL-17A, tumor necrosis factor alpha (TNF-α), and interferon-γ in cell culture supernatant were detected by flow cytometry. The number of samples in each group in the above experiments was 15. Data were statistically analyzed with analysis of variance for factorial design and independent sample t test. Results:After 1 h of culture, the chemotactic function score of cells in normal control group, Nr-CWS alone group, LPS alone group, and LPS+Nr-CWS group were 15.0, 14.5±0.5, 1.5±0.5, 12.0±1.5, respectively. Compared with those in normal control group, the chemotaxis distance, chemotactic cell percentage, chemotactic index, maximum chemotactic speed, and chemotactic function score of cells were significantly decreased in LPS alone group and LPS+Nr-CWS group (with t values of 18.36, 18.88, 54.28, 18.36, 46.77, 10.58, 14.74, 6.84, 10.58, and 4.24, respectively, P<0.05); compared with those in LPS alone group, the five chemotactic function indexes as above in LPS+Nr-CWS group were significantly increased (with t values of 11.47, 14.65, 11.62, 11.47, and 13.75, respectively, P<0.05). After 1 h of culture, compared with those in normal control group, the proportion and fluorescence intensity of phagocytosis cells were significantly increased in Nr-CWS alone group (with t values of 6.86 and 6.73, respectively, P<0.05), and the above two indexes were significantly decreased in LPS alone group (with t values of 7.35 and 22.72, respectively, P<0.05) and LPS+Nr-CWS group (with t values of 21.37 and 13.10, respectively, P<0.05). After 1 h of culture, compared with that in normal control group, the level of ROS of cells in LPS alone group was significantly increased ( t=6.64, P<0.05); compared with that in LPS alone group, the level of ROS of cells in LPS+Nr-CWS group was significantly decreased ( t=5.46, P<0.05). After 1 h of culture, compared with those in normal control group, the protein expressions of CD35, CD66b, and CD63 of cells were significantly increased in LPS alone group and LPS+Nr-CWS group (with t values of 16.75, 17.45, 10.82, 5.70, 19.35, and 15.37, respectively, P<0.05); compared with those in LPS alone group, the protein expressions of CD35, CD66b, and CD63 of cells were significantly decreased in LPS+Nr-CWS group (with t values of 4.92, 5.72, and 3.18, respectively, P<0.05). After 1 h of culture, compared with those in normal control group, the concentrations of IL-2, IL-4, IL-6, IL-10, IL-17A, TNF-α, and interferon-γ in cell culture supernatant were significantly increased in LPS alone group (with t values of 22.10, 9.50, 7.21, 10.22, 24.88, 8.43, and 47.48, respectively, P<0.05), and the concentrations of IL-6, IL-10, IL-17A, TNF-α, and interferon-γ in cell culture supernatant were significantly increased in LPS+Nr-CWS group (with t values of 4.68, 5.12, 8.02, 5.58, and 7.13, respectively, P<0.05); compared with those in LPS alone group, the concentrations of IL-2, IL-4, IL-6, IL-10, IL-17A, TNF-α, and interferon-γ in cell culture supernatant were significantly decreased in LPS+Nr-CWS group (with t values of 5.39, 2.83, 5.79, 2.90, 5.87, 4.88, and 39.64, respectively, P<0.05). Conclusions:Nr-CWS can enhance the phagocytosis ability of neutrophils in normal condition and improve the chemotactic function, ROS level, degranulation protein level, and inflammatory factor level of human neutrophils in infectious condition. Nr-CWS can enhance the anti-infection ability of human neutrophils by regulating its biological behavior in innate immunity.
9.Neutrophils mediate T lymphocyte function in septic mice via the CD80/cytotoxic T lymphocyte antigen-4 signaling pathway
Ran SUN ; Jiamin HUANG ; Lu LIU ; Yunxi YANG ; Mingming SONG ; Yiming SHAO ; Linbin LI ; Bingwei SUN
Chinese Critical Care Medicine 2021;33(7):849-854
Objective:To investigate the effect of neutrophils on T lymphocyte function in septic mice and the role of CD80/cytotoxic T lymphocyte antigen-4 (CTLA-4) signaling pathway in this modulated effects.Methods:① In vivo experiment: 6-8 weeks old male C57BL/6 mice were divided into sham operation group (Sham group, n = 20), Sham+CTLA-4 antibody treatment group (Sham+aCTLA-4 group, n = 20), cecal ligation and perforation (CLP) induced sepsis model group (CLP group, n = 30) and CLP+CTLA-4 antibody treatment group (CLP+aCTLA-4 group, n = 30) according to the random number table. CLP was used to reproduce mouse sepsis model. The mice in the Sham group were treated identically but their cecums were neither punctured nor ligated. In CTLA-4 antibody treatment groups, 50 μg CTLA-4 antibody was injected intraperitoneally 6 hours and 24 hours after the operation. Forty-eight hours after operation, 6 mice in Sham group and Sham+aCTLA-4 group, 14 mice in CLP group and CLP+aCTLA-4 group were randomly selected to detect the expression of CD69 in spleen. At the same time, spleen, bone marrow and peripheral blood were collected, and the expression of CD80 on neutrophils was detected by flow cytometry. The expression of CTLA-4 on the surface of T lymphocytes in spleen was detected by immunofluorescence and flow cytometry. The remaining mice in each group were used to observe the 96-hour survival after operation.② In vitro experiment 1: neutrophils were extracted from bone marrow of healthy mice and stimulated with LPS (1 mg/L) for 4, 8 and 12 hours respectively. The control group was added with the same amount of phosphate buffered saline (PBS) at each time point, and the expression of CD80 was detected at each time point.③ In vitro experiment 2: splenic T lymphocytes of healthy mice were extracted and divided into PBS control group, LPS group (final concentration of LPS 1 mg/L), neutrophil group and neutrophil+LPS group. In the latter two groups, the co-culture model of neutrophils and T lymphocytes was established, and then the corresponding treatment was given to detect the expression of CTLA-4 on the surface of T lymphocytes. With the above four groups as controls, CTLA-4 antibody treatment groups (final concentration of CTLA-4 antibody 50 mg/L) were set up respectively. After 48 hours, the level of interleukin-2 (IL-2) in the cell supernatant was detected by enzyme linked immunosorbent assay (ELISA). Results:① Results of in vivo experiment: compared with Sham group, the expression of CD80 on neutrophils in spleen, bone marrow and peripheral blood was significantly up-regulated, while the expression of CTLA-4 on the surface of T lymphocytes was significantly increased [(9.98±0.84)% vs. (3.48±0.64)%, P < 0.05]. It suggested that neutrophils may affect T lymphocytes function through CD80/CTLA-4 pathway in sepsis. Compared with CLP group, CTLA-4 antibody could significantly improve the 96-hour cumulative survival rate of CLP mice (56.25% vs. 18.75%, P < 0.05), and increase the expression of CD69 on the surface of T lymphocytes. It suggested that CTLA-4 antibodies might increase T lymphocytes activation in sepsis and improve survival. ② Results of in vitro experiment: with the prolongation of LPS stimulation, the expression of CD80 on neutrophils gradually increased in time-dependent manner as compared with PBS control group [4 hours: (6.35±0.40)% vs. (3.41±0.40)%, 8 hours: (8.57±0.64)% vs. (3.09±0.27)%, 12 hours: (19.83±1.06)% vs. (5.16±0.36)%, all P < 0.05]. Compared with PBS control group, the expression of CTLA-4 on CD4 +/CD8 + T lymphocytes was not significantly affected by LPS stimulation alone, but CTLA-4 was increased after co-culture with neutrophils [CD4 +: (4.92±0.30)% vs. (3.33±0.25)%, CD8 +: (4.26±0.21)% vs. (2.53±0.66)%, both P < 0.05], and the increased trend of CTLA-4 was more obvious after co-culture with LPS-stimulated neutrophils [CD4 +: (6.34±0.50)% vs. (3.33±0.25)%, CD8 +: (6.21±0.41)% vs. (2.53±0.66)%, both P < 0.05]. In the PBS control group and LPS group, CTLA-4 antibody had no significant effect on IL-2 secretion of T lymphocytes. Compared with PBS control group, co-culture with neutrophils could inhibit the secretion of IL-2 by T lymphocytes (ng/L: 1 938.00±68.45 vs. 2 547.00±218.00, P < 0.05), and the inhibitory effect of neutrophils stimulated by LPS was more obvious (ng/L: 1 073.00±34.39 vs. 2 547.00±218.00, P < 0.05). CTLA-4 antibodies could partially restore IL-2 secretion. In conclusion, after promoting the expression of CTLA-4 on the surface of T lymphocytes, neutrophils might mediate the inhibition of T lymphocytes function by reducing the production of IL-2. Conclusions:Neutrophils mediate T lymphocytes dysfunction in sepsis, and the CD80/CTLA-4 pathway plays an important role. The CTLA-4 antibody improves survival and T lymphocytes function in sepsis mice, which may be a new method of immunotherapy for sepsis.
10.Evaluation on application of virtual reality technology in dental implant process training
Yong ZHOU ; Sihui ZHANG ; Xiaoxian ZHAO ; Wanlu CHEN ; Qun LEI ; Bingwei HE ; Wenxiu HUANG ; Dong WU ; Jiang CHEN
Chinese Journal of Stomatology 2021;56(8):799-804
Objective:To explore the application effect and evaluation of virtual reality technology in oral implant therapy training.Methods:In November 2018, one adult patient (female, 36 years old) with missing right mandibular first molar was treated in the Department of Implantology, School and Hospital of Stomatology, Fujian Medical University. The three-dimensional virtual models of mandible and implant surgery tools were established, and the virtual reality software (Unity 3D 5.5.1) was imported. Combined with the virtual reality head mounted display, a virtual reality training system simulating the dental implant treatment process was independently developed. Ten refresher doctors and 20 graduate students in Department of Implantology, School and Hospital of Stomatology, Fujian Medical University from September 2018 to December 2019 were recruited as the experimental objects (no clinical experience was found). According to the level and seniority of doctors, they were randomly divided into virtual training group and conventional training control group, which made the two groups comparable, with 15 in each group. Subjective scores (including anatomical structure, surgical field of vision, cavity preparation, implant placement and process mastery) were given after the corresponding training in the two groups, and the virtual reality training system was used to test. The mesial and distal direction, buccolingual direction, depth and angle deviation of implants before and after the training were analyzed, and the differences between the two groups were compared.Results:The subjective scores of five dimensions in the virtual training group were significantly higher than those in the conventional training control group ( P<0.05). In the virtual training group, the mesial and distal, buccolingual, depth and angle deviation of implants were (0.73±0.33), (0.78±0.41), (0.61±0.32) mm and 6.66°±3.87°. All of them were significantly lower than those in the control group [(0.85±0.32), (1.12±0.38), (0.89±0.24) mm and 9.68°±3.74°] ( P<0.05). Conclusions:The self-developed virtual reality system of oral implant has good application effect, good operability and predictability. It can be effectively carried out in implant education and training, and it can strengthen skills of doctors, and is conducive to the practical operation.

Result Analysis
Print
Save
E-mail