1.Application value of hinge position design of Ilizarov circular external fixator for correcting clubfoot deformity in preventing ankle dislocation.
Dongfeng ZHANG ; Siyu YANG ; Bingke SHI ; Shuliang LI ; Lei ZHEN ; Yushun WANG ; Yingqi ZHANG ; Sihe QIN ; Qi PAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(8):989-993
OBJECTIVE:
To summarize the methods of ankle hinge position design in the correction of clubfoot deformity by Ilizarov method, and to explore its application value in the prevention of ankle dislocation.
METHODS:
A retrospective study was conducted including 28 patients with rigid clubfoot deformity (34 feet) who met the selection criteria and admitted between September 2021 and December 2024. There were 19 males and 9 females with an average age of 31.8 years (range, 19-47 years). According to Dimeglio classification, there were 21 feet of degree Ⅲ and 13 feet of degree Ⅳ. The causes were traumatic sequelae in 9 cases, congenital foot deformity in 15 cases, spina bifida sequelae in 1 case, peripheral neuropathy in 1 case, and cerebral palsy sequelae in 2 cases. The malformation lasted from 6 to 46 years, with an average of 29.3 years. All patients were treated with Ilizarov circular external fixator, and the hinge position of ankle joint was planned according to the standard lateral X-ray film of foot and ankle and the principle of Ilizarov limb deformity correction center of rotation angulation (CORA) before operation. The 2008 International Clubfoot Study Group (ICFSG) scoring system was used to evaluate the efficacy.
RESULTS:
The deformity of rigid clubfoot was completely corrected in all patients, and the patients could walk with plantar weight-bearing, and the ankle weight-bearing walking significantly improved when compared with that before operation. There was no complication such as ankle dislocation, talus impact or extrusion, local skin necrosis, needle tract infection, or numbness of extremities during the correction process. All patients were followed up 5-39 months, with an average of 18.1 months. At last follow-up, according to the ICFSG scoring system, 23 feet were excellent, 10 feet were good, and 1 foot was fair, and the excellent and good rate was 97%.
CONCLUSION
Designing the position of the ankle hinge according to the principle of CORA can effectively avoid ankle dislocation, talus impingement, tibiotalar joint extrusion, and other ankle adverse events in the process of correcting clubfoot deformity, which has good application value in clinical practice.
Humans
;
Male
;
Female
;
Clubfoot/diagnostic imaging*
;
Ilizarov Technique/instrumentation*
;
Adult
;
Retrospective Studies
;
External Fixators
;
Ankle Joint/diagnostic imaging*
;
Middle Aged
;
Joint Dislocations/prevention & control*
;
Treatment Outcome
;
Young Adult
2.The establishment of HCV IgG antibody chemiluminescence detection method and preliminary application
Jun HOU ; Yan HU ; Shunquan WU ; Bingke BAI ; Qiyu JIANG ; Sujuan SHI ; Baojun WANG ; Weijun OU ; Panyong MAO
Chinese Journal of Laboratory Medicine 2015;(3):159-162
Objective To establish a chemiluminecentdetection method ( CLIA ) of HCV IgG antibody for the detection of HCV infection and therefore lay a foundation for the research and development of testing kit.Methods Based upon the indirect ELISA method, the microwell plate was coated with HCV-NS3 and HCV-Core antigen expressed through gene engineering, and the anti-human IgG antibody was labeled with horse radish peroxidase.In this way, the chemiluminesent detection method of HCV IgG antibody was established.Meanwhile, the serum specimen of randomly selected 198 patients infected with HCV from No.302 Hospital of PLA and 222 blood donors, and the results were compared.Results The HCV-IgG antibody, a positive consistent rate of 99.0%( 196/198 ) , a negative consistent rate of 98.2%(218/222), and a total consistent rate of 98.6%(414/420) were found through testing 420 serum specimen with self-made agent and contrast agent.One HCV positive serum was repetitively tested with the self-made agent for 10 times, and a coefficient of variation ( CV) of less than 10% was found.Conclusion The chemiluminescent detection method of HCV IgG antibody is initially established, and the method, with an outstanding specificity and sensitivity, is applicable for screening blood donors, clinically detecting HCV infection as well as epidemiological survey.

Result Analysis
Print
Save
E-mail