1.Association between incidence of hand-foot-mouth disease and meteorological factors
YANG Ya ; FEI Jie ; YANG Yiwei ; ZHANG Bing ; ZHANG Qian ; LU Yihan
Journal of Preventive Medicine 2025;37(4):346-349,355
Objective:
To examine the association between incidence of hand-foot-mouth disease (HFMD) and meteorological factors, so as to provide the basis for the prevention and control of HFMD.
Methods:
The number of HFMD cases in Jiading District, Shanghai Municipality from 2016 to 2023 were collected through the Chinese Disease Prevention and Control Information System, and meteorological data were obtained from the Shanghai Meteorological Bureau. The associations of daily average temperature, daily average relative humidity, and daily average atmospheric pressure with the daily number of HFMD cases were analyzed using a distributed lag non-linear model (DLNM).
Results:
A total of 21 555 HFMD cases were reported in Jiading District from 2016 to 2023, with an average annual incidence of 132.57/100 000. There were 12 762 male cases (59.21%) and 8 793 female cases (40.79%). The main peak of incidence occurred from June to August, and the secondary peak was from October to December. DLNM analysis showed that the incidence risk of HFMD first increased and then decreased with the increase of daily average temperature, and first decreased and then increased with the prolongation of the lag time. The cumulative lag risk was higher when the daily average temperature ranged from 18.4 to 35.1 ℃, and the maximum cumulative lag effect was observed at 27.8 ℃ (RR=5.522, 95%CI: 4.751-6.370). The incidence risk of HFMD first increased and then decreased with the increase of daily average relative humidity, and first decreased, then increased and then decreased again with the prolongation of the lag time. The cumulative lag risk was higher when the daily average relative humidity ranged from 71.7% and 90.8%, and the maximum cumulative lag effect was observed at 81.8% (RR=1.603, 95%CI: 1.321-1.995). The incidence risk of HFMD decreased with the increase of daily average atmospheric pressure, and decreased with the prolongation of the lag time when the daily average atmospheric pressure was greater than 1 015.80 hPa. When the daily average atmospheric pressure was less than 1 015.80 hPa, the incidence risk of HFMD increased with the prolongation of the lag time. The maximum cumulative lag effect was observed at 986.80 hPa (RR=8.513, 95%CI: 1.401-36.625).
Conclusion
The incidence risk of HFMD in Jiading District initially increases and then decreases with increasing temperature and relative humidity, while it decreases with increasing atmospheric pressure, and these effects exhibit a lagged response.
2.Research Progress of Vagal Nerve Regulation Mechanism in Acupuncture Treatment of Atrial Fibrillation.
Lu-Lu CAO ; Hui-Rong LIU ; Ya-Jie JI ; Yin-Tao ZHANG ; Bing-Quan WANG ; Xiao-Hong XUE ; Pei WANG ; Zhi-Hui LUO ; Huan-Gan WU
Chinese journal of integrative medicine 2025;31(3):281-288
Atrial fibrillation (AF) is the most common arrhythmia in clinical practice. It has a high prevalence and poor prognosis. The application of antiarrhythmic drugs and even surgery cannot completely treat the disease, and there are many sequelae. AF can be classified into the category of "palpitation" in Chinese medicine according to its symptoms. Acupuncture has a significant effect on AF. The authors find that an important mechanism of acupuncture in AF treatment is to regulate the cardiac vagus nerve. Therefore, this article intends to review the distribution and function of vagus nerve in the heart, the application and the regulatroy effect for the treatment of AF.
Atrial Fibrillation/physiopathology*
;
Humans
;
Acupuncture Therapy
;
Vagus Nerve/physiology*
;
Animals
3.Causal Associations between Particulate Matter 2.5 (PM 2.5), PM 2.5 Absorbance, and Inflammatory Bowel Disease Risk: Evidence from a Two-Sample Mendelian Randomization Study.
Xu ZHANG ; Zhi Meng WU ; Lu ZHANG ; Bing Long XIN ; Xiang Rui WANG ; Xin Lan LU ; Gui Fang LU ; Mu Dan REN ; Shui Xiang HE ; Ya Rui LI
Biomedical and Environmental Sciences 2025;38(2):167-177
OBJECTIVE:
Several epidemiological observational studies have related particulate matter (PM) exposure to Inflammatory bowel disease (IBD), but many confounding factors make it difficult to draw causal links from observational studies. The objective of this study was to explore the causal association between PM 2.5 exposure, its absorbance, and IBD.
METHODS:
We assessed the association of PM 2.5 and PM 2.5 absorbance with the two primary forms of IBD (Crohn's disease [CD] and ulcerative colitis [UC]) using Mendelian randomization (MR) to explore the causal relationship. We conducted two-sample MR analyses with aggregated data from the UK Biobank genome-wide association study. Single-nucleotide polymorphisms linked with PM 2.5 concentrations or their absorbance were used as instrumental variables (IVs). We used inverse variance weighting (IVW) as the primary analytical approach and four other standard methods as supplementary analyses for quality control.
RESULTS:
The results of MR demonstrated that PM 2.5 had an adverse influence on UC risk (odds ratio [ OR] = 1.010; 95% confidence interval [ CI] = 1.001-1.019, P = 0.020). Meanwhile, the results of IVW showed that PM 2.5 absorbance was also causally associated with UC ( OR = 1.012; 95% CI = 1.004-1.019, P = 0.002). We observed no causal relationship between PM 2.5, PM 2.5 absorbance, and CD. The results of sensitivity analysis indicated the absence of heterogeneity or pleiotropy, ensuring the reliability of MR results.
CONCLUSION
Based on two-sample MR analyses, there are potential positive causal relationships between PM 2.5, PM 2.5 absorbance, and UC.
Humans
;
Mendelian Randomization Analysis
;
Particulate Matter/analysis*
;
Polymorphism, Single Nucleotide
;
Inflammatory Bowel Diseases/genetics*
;
Air Pollutants/analysis*
;
Crohn Disease/genetics*
;
Colitis, Ulcerative/genetics*
;
Genome-Wide Association Study
;
Risk Factors
;
Environmental Exposure
5.Real-world Study of the Safety and Efficacy of Pembrolizumab in the Treatment of Advanced Non-small Cell Lung Cancer
WAN NING ; WANG BING ; GUO YA ; HE ZIJIAN ; YANG CHEN ; YANG NING ; LU LIQING ; LIANG HONGYI ; XIAO WEIBIN ; YANG DANDAN ; CHEN ZHUOJIA ; FANG WENFENG ; LIANG WEITING
Chinese Journal of Lung Cancer 2024;27(10):745-754
Background and objective Pembrolizumab(PEM)has been shown to be effective in clinical trials for the treatment of advanced non-small cell lung cancer(NSCLC),but clinical trials were based on cohorts of patients selected on specific criteria,and whether the findings are consistent with real-world patients is debatable.The aim of this study is to evaluate the efficacy and safety of PEM in the treatment of advanced NSCLC based on real-world data.Methods A retro-spective collection of real-world data from patients with advanced NSCLC receiving PEM was conducted.Propensity score matching was used to eliminate inter-group differences and assess the efficacy and safety of PEM compared to chemotherapy.Results Among 450 matched patients,the incidence rates of any-grade adverse events were 79.87%in the PEM group and86.71%inthe chemotherapy group,while the incidence rates of grade>3 adverse events were 4.03%and 7.31%,respectively.The objective response rates were 48.63%for PEM and 36.00%for chemotherapy(P=0.011).The median progression-free survival was 15.5 months for PEM and 8.8 months for chemotherapy(P<0.001),and the median overall survival was not reached for PEM and 26.2 months for chemotherapy(P<0.001).Conclusion PEM treatment for advanced NSCLC demonstrates favorable survival outcomes and acceptable safety in real-world clinical practice.
6.An Enhancer LncRNA Regulates NFE2 Expression and Proliferation in Human Leukemic K562 Cells
Yan-Fei LU ; Song-Ya QU ; Jing-Jing ZHU ; Chao LIU ; Jian WANG ; Bing-She HAN ; Jun-Fang ZHANG
Progress in Biochemistry and Biophysics 2024;51(1):190-201
ObjectiveTranscription factor NFE2 was observed abnormal expression in myeloproliferative neoplasm (MPN) patients. However, how NFE2 is transcriptionally regulated remains ambiguous. This study aims to explore the elements and molecular mechanisms involved in the transcriptional regulation of NFE2. MethodsActive enhancers were predicted by public NGS data and conformed experimentally via dual luciferase reporter assay. After that, PRO-seq and GRO-seq data was used to detect enhancer RNAs transcribed from these enhancers. RACE was utilized to clone the full length enhancer RNA (eRNA) transcripts, and RT-qPCR was used to measure their expression in different leukemia cell lines as well as the transcript levels during induced differentiation. Finally, to investigate the molecular function of the eRNA, overexpression and knockdown of the eRNA via lentivirus system was performed in K562 cells. ResultsWe identified three enhancers regulating NFE2 transcription, which located at -3.6k, -6.2k and +6.3k from NFE2 transcription start site (TSS) respectively. At the -3.6k enhancer, we cloned an eRNA transcript and characterized that as a lncRNA which was expressed and located in the nucleus in three types of leukemia cell lines. When this lncRNA was overexpressed, expression of NFE2 was upregulated and decreases of K562 cell proliferation and migration ability were observed. While knocking down of this lncRNA, the level of NFE2 decreases correspondingly and the proliferation ability of K562 cells increases accordingly. ConclusionWe identified an enhancer lncRNA that regulates NFE2 transcription positively and suppresses K562 cell proliferation.
7.Development and characteristics of auricular fumigation moxibustion combined with heat-sensitive moxibustion device.
Xue-Tao ZHANG ; Zhen WANG ; Han-Xiao WANG ; Ya-Lu WANG ; Xin WU ; Kun WANG ; Shuai CUI ; Mei-Qi ZHOU ; Hui LUO ; Can-Guang SUN ; Sheng-Bing WU
Chinese Acupuncture & Moxibustion 2023;43(11):1333-1337
A moxibustion device with the functions of auricular fumigation moxibustion and heat-sensitive moxibustion is designed. The smoke of the ignited moxa stick is used for the fumigation moxibustion at the external auditory canal, while the heat generated works on Dazhui (GV 14) for heat-sensitive moxibustion. The device consists of five parts, i.e. combustion chamber, smoke pipe, smoke processing chamber, power module and connector. It solves the limitations such as unpleasant experience in treatment, unfavorable temperature control, easy scalding and excessive manual dependence induced by usual fumigation moxibustion and during heat-sensitive moxibustion. This moxibustion device may improve the safety and convenience when delivering the treatment with fumigation moxibustion and heat-sensitive moxibustion, as well as the work efficiency of medical staff.
Humans
;
Moxibustion
;
Hot Temperature
;
Fumigation
;
Smoke
;
Temperature
8. Roscovitine rescuing neuronal loss and neuroinflammation in brain regions associated with Parkinson’s disease mice
Ye LIU ; Ya-Nan CHU ; Cen-Lu XU ; Jia-Cheng HE ; Bing-Yin SU ; Hao-Ran TAI ; Ya-Nan CHU ; Bing-Yin SU ; Hao-Ran TAI
Acta Anatomica Sinica 2023;54(6):635-643
[Abstract] Objective To investigate the effect and possible mechanism of cell cycle-dependent kinase (Cdk)5 inhibitor Roscovitine on 1-methyl4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced pathological changes in brain regions associated with Parkinson’ s disease (PD) model mice. Methods The effect of Roscovitine on the relative expression levels of P25 and Cdk5 proteins was detected by Western blotting in MPP
9.Development and characteristics of automatic ash-removal heat-sensitive moxibustion device.
Xue-Tao ZHANG ; Han-Xiao WANG ; Zhen WANG ; Ya-Lu WANG ; Shuai CUI ; Mei-Qi ZHOU ; Hui LUO ; Can-Guang SUN ; Ming HAO ; Wen HONG ; Sheng-Bing WU
Chinese Acupuncture & Moxibustion 2023;43(5):597-599
An automatic ash-removal heat-sensitive moxibustion device was developed, which could keep relatively constant temperature of heat-sensitive moxibustion, and realize the automatic ignition and automatic ash removal of moxa sticks during heat-sensitive moxibustion. The automatic ash-removal heat-sensitive moxibustion device comprises a bracket and a moxibustion box fixed on the top of the bracket; the bracket is composed of a base and a movable telescopic arm. This device can solve the problems of temperature instability, moxa ash blocking heat transfer and moxa ash falling during heat-sensitive moxibustion, avoiding the scalding caused by moxa ash falling, and reduce the workload of medical staff.
Humans
;
Hot Temperature
;
Moxibustion
;
Temperature
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve


Result Analysis
Print
Save
E-mail