1.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
2.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
3.Correlation analysis between CT equipment and socio economic development situation in medical institutions of various grade and classification in Jiangsu province
Jiaming LU ; Qiming DENG ; Xiang LI ; Xin ZHANG ; Zhengge WANG ; Ming LI ; Ximing WANG ; Cheng LI ; Bing ZHANG ; Chunhong HU
China Medical Equipment 2025;22(3):97-101
Objective:To investigate the situation of computed tomography(CT)equipment and socio economic development of various grades and classifications of medical institutions in Jiangsu Province,and to analyze the interrelationship between them.Methods:From October 20,2023 to November 20,2023,a questionnaire survey was conducted on imported and domestic CT equipment of various grades and classifications of medical institutions in 13 prefecture-level cities in Jiangsu Province through online questionnaire survey of"questionnaire star".The gross domestic product(GDP)of each prefecture-level city in Jiangsu province was used as an indicator of measuring the level of socio-economic development in the region.The CT number,the row number of detector,quality of image,the total examination case number of daily average and the daily average case number of single machine examination of medical institutions of various grades and classifications of 13 prefecture-level cities were used to conduct correlation analysis with GDP values of various districts.Results:A total of 910 questionnaires were distributed,and 512 questionnaires were retrieved.There were 482 valid questionnaires in the 512 questionnaires,and the valid rate was 94.15,which involved to 482 various grade and classification institutions of 13 prefecture-level cities in Jiangsu province.The number of imported and domestic CT equipment in the 13 prefecture-level cities of Jiangsu Province positively correlated with the GDP of each city(r=0.882,0.880,P<0.001).The number of imported CT equipment with 64 rows and more than 64 rows,and with less than 64 rows,and the number of domestic CT equipment with 64 rows and more than 64 rows,and with less than 64 rows all positively correlated with the GDP of each city(r=0.880,0.881,0.736,0.897,P<0.05).The total number of daily average of examinations for imported and domestic CT equipment of 13 prefecture-level cities positively correlated with the GDP of each city(r=0.774,0.814,P<0.05).There were no significant difference in the image quality and the daily average case number of single machine examination between the domestic CT equipment and the imported CT equipment(P>0.05).Conclusion:The medical institutions of city with high level of economic development have more quantitative and more high-end CT equipment,and the quality of image of domestic CT equipment is equal to that of imported CT equipment regardless of the high and low level of economic development.
4.CT manifestations of pancreatitis related perpancreatic aneurysms
Shiyong ZHANG ; Ni HUANG ; Jincheng PENG ; Guo DENG ; Xin ZHENG ; Xiang QING ; Wenbin XIAO ; Bing MING ; Yong ZHANG ; Wen HUANG ; Gang MAI
Chinese Journal of Hepatobiliary Surgery 2025;31(9):685-689
Objective:To explore the CT manifestation characteristics of peripancreatic aneurysms related to pancreatitis (PRPA).Methods:A retrospective analysis was conducted on the clinical data of 15 patients with pancreatitis-related aneurysms collected in Deyang People's Hospital from June 2017 to February 2025. Among them, there were 11 males and 4 females, with an age of (56.5±16.9) years. Record the CT manifestations of the patients, and observe the PRPA tumor-carrying arteries, morphology, quantity, bleeding, calcification, dynamic changes, etc.Results:The CT results showed that there were a total of 26 PRPAs in 15 patients. The aneurysm walls of the PRPAs had no calcification, among which 12 cases were single and 1 case was double. Two cases were multiple. The patients were pancreatitis complicated with muscle fiber dysplasia. Among them, one case had 5 PRPAs and the other had 7 PRPAs. Of the 26 PRPAs, 12 were sac-like, 8 were beaded, 4 were fusiform, and 2 were columnar in shape. The numbers of aneurysm-carrying arteries and PRPA were as follows: 8 in the pancreaticoduodenal artery, 7 in the hepatic artery and its branches, 6 in the splenic artery and its branches, 2 in the left gastric artery, 1 in the gastroduodenal artery, 1 in the middle colonic artery, and 1 in the ileocolonic artery. The CT diagnosis report missed 16 PRPAs, with a missed diagnosis rate of 61.5% (16/26). Among the 11 ruptured PRPAs, 4 were missed, with a missed diagnosis rate of 36.4%. Three missed aneurysms were diagnosed by digital subtraction angiography, and one was retrospectively analyzed by CT. Among the 15 unruptured PRPAs, 12 were missed, with a missed diagnosis rate of 80.0%. All the missed aneurysms were detected by retrospective CT analysis. There were 2 images without re-examination and 24 images with re-examination. Among the PRPAs with re-examination images, 4 disappeared after interventional embolization on the same day, 1 relapsed after interventional embolization on the same day, with a reduction in volume and disappeared after 3 days. Three cases underwent elective interventional embolization, among which two shranked and one enlarged before interventional embolization. Among the 16 cases that did not receive interventional treatment, 7 disappeared on their own, 1 was completely liquefied, 5 shrank but did not disappear, 2 remained stable in size without any change, and 1 increased. Among the re-examined PRPA images, 7 showed signs of enlargement.Conclusion:The main characteristics of PRPA are high rupture rate, prone to missed diagnosis and dynamic changes in size.
5.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
6.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
7.Correlation analysis between CT equipment and socio economic development situation in medical institutions of various grade and classification in Jiangsu province
Jiaming LU ; Qiming DENG ; Xiang LI ; Xin ZHANG ; Zhengge WANG ; Ming LI ; Ximing WANG ; Cheng LI ; Bing ZHANG ; Chunhong HU
China Medical Equipment 2025;22(3):97-101
Objective:To investigate the situation of computed tomography(CT)equipment and socio economic development of various grades and classifications of medical institutions in Jiangsu Province,and to analyze the interrelationship between them.Methods:From October 20,2023 to November 20,2023,a questionnaire survey was conducted on imported and domestic CT equipment of various grades and classifications of medical institutions in 13 prefecture-level cities in Jiangsu Province through online questionnaire survey of"questionnaire star".The gross domestic product(GDP)of each prefecture-level city in Jiangsu province was used as an indicator of measuring the level of socio-economic development in the region.The CT number,the row number of detector,quality of image,the total examination case number of daily average and the daily average case number of single machine examination of medical institutions of various grades and classifications of 13 prefecture-level cities were used to conduct correlation analysis with GDP values of various districts.Results:A total of 910 questionnaires were distributed,and 512 questionnaires were retrieved.There were 482 valid questionnaires in the 512 questionnaires,and the valid rate was 94.15,which involved to 482 various grade and classification institutions of 13 prefecture-level cities in Jiangsu province.The number of imported and domestic CT equipment in the 13 prefecture-level cities of Jiangsu Province positively correlated with the GDP of each city(r=0.882,0.880,P<0.001).The number of imported CT equipment with 64 rows and more than 64 rows,and with less than 64 rows,and the number of domestic CT equipment with 64 rows and more than 64 rows,and with less than 64 rows all positively correlated with the GDP of each city(r=0.880,0.881,0.736,0.897,P<0.05).The total number of daily average of examinations for imported and domestic CT equipment of 13 prefecture-level cities positively correlated with the GDP of each city(r=0.774,0.814,P<0.05).There were no significant difference in the image quality and the daily average case number of single machine examination between the domestic CT equipment and the imported CT equipment(P>0.05).Conclusion:The medical institutions of city with high level of economic development have more quantitative and more high-end CT equipment,and the quality of image of domestic CT equipment is equal to that of imported CT equipment regardless of the high and low level of economic development.
8.CT manifestations of pancreatitis related perpancreatic aneurysms
Shiyong ZHANG ; Ni HUANG ; Jincheng PENG ; Guo DENG ; Xin ZHENG ; Xiang QING ; Wenbin XIAO ; Bing MING ; Yong ZHANG ; Wen HUANG ; Gang MAI
Chinese Journal of Hepatobiliary Surgery 2025;31(9):685-689
Objective:To explore the CT manifestation characteristics of peripancreatic aneurysms related to pancreatitis (PRPA).Methods:A retrospective analysis was conducted on the clinical data of 15 patients with pancreatitis-related aneurysms collected in Deyang People's Hospital from June 2017 to February 2025. Among them, there were 11 males and 4 females, with an age of (56.5±16.9) years. Record the CT manifestations of the patients, and observe the PRPA tumor-carrying arteries, morphology, quantity, bleeding, calcification, dynamic changes, etc.Results:The CT results showed that there were a total of 26 PRPAs in 15 patients. The aneurysm walls of the PRPAs had no calcification, among which 12 cases were single and 1 case was double. Two cases were multiple. The patients were pancreatitis complicated with muscle fiber dysplasia. Among them, one case had 5 PRPAs and the other had 7 PRPAs. Of the 26 PRPAs, 12 were sac-like, 8 were beaded, 4 were fusiform, and 2 were columnar in shape. The numbers of aneurysm-carrying arteries and PRPA were as follows: 8 in the pancreaticoduodenal artery, 7 in the hepatic artery and its branches, 6 in the splenic artery and its branches, 2 in the left gastric artery, 1 in the gastroduodenal artery, 1 in the middle colonic artery, and 1 in the ileocolonic artery. The CT diagnosis report missed 16 PRPAs, with a missed diagnosis rate of 61.5% (16/26). Among the 11 ruptured PRPAs, 4 were missed, with a missed diagnosis rate of 36.4%. Three missed aneurysms were diagnosed by digital subtraction angiography, and one was retrospectively analyzed by CT. Among the 15 unruptured PRPAs, 12 were missed, with a missed diagnosis rate of 80.0%. All the missed aneurysms were detected by retrospective CT analysis. There were 2 images without re-examination and 24 images with re-examination. Among the PRPAs with re-examination images, 4 disappeared after interventional embolization on the same day, 1 relapsed after interventional embolization on the same day, with a reduction in volume and disappeared after 3 days. Three cases underwent elective interventional embolization, among which two shranked and one enlarged before interventional embolization. Among the 16 cases that did not receive interventional treatment, 7 disappeared on their own, 1 was completely liquefied, 5 shrank but did not disappear, 2 remained stable in size without any change, and 1 increased. Among the re-examined PRPA images, 7 showed signs of enlargement.Conclusion:The main characteristics of PRPA are high rupture rate, prone to missed diagnosis and dynamic changes in size.
9.Synthesis of a Dual-Function Fluorescent Probe for Detection of Ferric Ions and Hydrazine
Ning DUAN ; Le-Yuan DING ; Bing DENG ; Shao-Xiang YANG
Chinese Journal of Analytical Chemistry 2024;52(6):809-817,中插1-中插10
A new Schiff base fluorescence probe (E)-3-(4-(E)-((4-hydroxyphenyl) imino) methyl) phenyl)-1-(6-methoxynaphthal-2-yl) isopropyl-2-en-1-one (DFFH) was synthesized by using 6-methoxy-2-acetylnaphthalene as raw material. The probe was characterized by nuclear magnetic resonance (1H NMR,13C NMR) and high-resolution mass spectroscopy (HRMS),etc. In the EtOH-H2O (1:4,V/V) system,the 4-hydroxyaniline portion of probe DFFH complexed with Fe3+to form a 1:1 metal complex,resulting in a significant decrease in fluorescence at 386 nm. In the DMSO-H2O (9:1,V/V,pH=5) system,N2H4 reacted with α,β-unsaturated carbonyl group and underwent cyclization addition reaction,and at the same time,the cleavage of the imine bond released aldehyde group from the probe,showing a ratio type fluorescence recognition characteristices. The luminescence intensity of the probe solution decreased slightly upon the additon of Fe3+,and the probe solution changed from colourless to yellowish-brown with the addition of different concentrations of N2H4. Whereas the detection of Fe3+and N2H4 did not interfere with each other. The experimental results showed that probe DFFH had high sensitivity and selectivity toward Fe3+and N2H4,with detection limit of 34.0 nmol/L for Fe3+and 30.0 nmol/L for N2H4,respectively. Moreover,probe DFFH was applied to detection of the contents of Fe3+and N2H4 in actual water samples with satisfactory results,and the spiking recoveries were 96.5%~102.3%and 98.1%~103.0%,respectively.

Result Analysis
Print
Save
E-mail