1.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
2.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
3.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
4.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
5.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
6.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
7.Research progress on biofilm microecology in chronic suppurative otitis media.
Xin Cheng ZHONG ; Xiao OUYANG ; Yu Bing LIAO ; Ming Zhu TAO ; Jiao PENG ; Zhi Qing LONG ; Xiang Jie GAO ; Ying CAO ; Ming Hua LUO ; Guo Jiang PENG ; Zhi Xiong ZHOU ; Guan Xiong LEI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(6):621-625
8.Regulation of Baicalin on Growth of Extranodal NK/T Cell Lymphoma Cells through FOXO3/CCL22 Signaling Pathway.
Xiao-Hui DUAN ; Hong LI ; Yao LYU ; Jing LIU ; Shi-Xiong WANG ; Zhen-Tian WU ; Bing-Xuan WANG ; Ming LU ; Jian-Hong WANG ; Rong LIANG
Journal of Experimental Hematology 2023;31(3):730-738
OBJECTIVE:
To investigate the effect of baicalin on the growth of extranodal NK/T cell lymphoma (ENKTCL) cells and its related mechanism.
METHODS:
Normal NK cells and human ENKTCL cells lines SNK-6 and YTS were cultured, then SNK-6 and YTS cells were treated with 5, 10, 20 μmol/L baicalin and set control. Cell proliferation and apoptosis was detected by Edu method and FCM method, respectively, and expressions of BCL-2, Bax, FOXO3 and CCL22 proteins were detected by Western blot. Interference plasmids were designed and synthesized. FOXO3 siRNA interference plasmids and CCL22 pcDNA overexpression plasmids were transfected with PEI transfection reagent. Furthermore, animal models were established for validation.
RESULTS:
In control group and 5, 10, 20 μmol/L baicalin group, the proliferation rate of SNK-6 cells was (56.17±2.96)%, (51.92±4.63)%, (36.42±1.58)%, and (14.60±2.81)%, respectively, while that of YTS cells was (58.85±2.98)%, (51.38±1.32)%, (34.75±1.09)%, and (15.45±1.10)%, respectively. In control group and 5, 10, 20 μmol/L baicalin group, the apoptosis rate of SNK-6 cells was (5.93±0.74)%, (11.78±0.34)%, (28.46±0.44)%, and (32.40±0.37)%, respectively, while that of YTS cells was (7.93±0.69)%, (16.29±1.35)%, (33.91±1.56)%, and (36.27±1.06)%, respectively. Compared with control group, the expression of BCL-2 protein both in SNK-6 and YTS cells decreased significantly (P<0.001), and the expression of Bax protein increased in SNK-6 cells only when the concentration of baicalin was 20 μmol/L (P<0.001), while that in YTS cells increased in all three concentrations(5, 10, 20 μmol/L) of baicalin (P<0.001). The expression of FOXO3 protein decreased while CCL22 protein increased in ENKTCL cell lines compared with human NK cells (P<0.001), but the expression of FOXO3 protein increased (P<0.01) and CCL22 protein decreased after baicalin treatment (P<0.001). Animal experiments showed that baicalin treatment could inhibit tumor growth. The expression of CCL22 protein in ENKTCL tissue of nude mice treated with baicalin decreased compared with control group (P<0.01), while the FOXO3 protein increased (P<0.05). In addition, FOXO3 silencing resulted in the decrease of FOXO3 protein expression and increase of CCL22 protein expression (P<0.01, P<0.001).
CONCLUSION
Baicalin can inhibit proliferation and promote apoptosis of ENKTCL cell lines SNK-6 and YTS, up-regulate the expression of Bax protein, down-regulate the expression of BCL-2 protein, and down-regulate the expression of CCL22 protein mediated by FOXO3. Animal experiment shown that the baicalin can inhibit tumor growth. Baicalin can inhibit the growth and induce apoptosis of ENKTCL cells through FOXO3/CCL22 signaling pathway.
Animals
;
Mice
;
Humans
;
Lymphoma, Extranodal NK-T-Cell/pathology*
;
Forkhead Box Protein O3/metabolism*
;
bcl-2-Associated X Protein/pharmacology*
;
Mice, Nude
;
Signal Transduction
;
Apoptosis
;
Proto-Oncogene Proteins c-bcl-2/metabolism*
;
Chemokine CCL22/pharmacology*
9.Protective repair of discolored breast cancer HE sections by color transfer.
Hui Zhe WANG ; Guo Xin SUN ; Xiong YAN ; Tian Hui SU ; Jing XU ; Fei LI ; Xin LIU ; Bing Dong WANG ; Li Ming XIN ; Xiao ZOU
Chinese Journal of Pathology 2023;52(5):507-511
10.Effect of Baicalin on Pyroptosis of Diffuse Large B-Cell Lymphoma Cell Lines DB and Its Mechanism.
Ming LU ; Chun-Ling HE ; Zhen-Tian WU ; Yao LYU ; Xiao-Hui DUAN ; Bing-Xuan WANG ; Shi-Xiong WANG ; Jian-Hong WANG ; Rong LIANG
Journal of Experimental Hematology 2023;31(6):1706-1713
OBJECTIVE:
To investigate the effect of Baicalin on the proliferation and pyroptosis of diffuse large B-cell lymphoma cell line DB and its mechanism.
METHODS:
DB cells were treated with baicalin at different concentrations (0, 5, 10, 20, 40 μmol/L). Cell proliferation was detected by CCK-8 assay and half maximal inhibitory concentration (IC50) was calculated. The morphology of pyroptosis was observed under an inverted microscope, the integrity of the cell membrane was verified by LDH content release assay, and the expressions of pyroptosis-related mRNA and protein (NLRP3, GSDMD, GSDME, N-GSDMD, N-GSDME) were detected by real-time fluorescence quantitative PCR and Western blot. In order to further clarify the relationship between baicalin-induced pyroptosis and ROS production in DB cells, DB cells were divided into control group, baicalin group, NAC group and NAC combined with baicalin group. DB cells in the NAC group were pretreated with ROS inhibitor N-acetylcysteine (NAC) 2 mmol/L for 2 h. Baicalin was added to the combined treatment group after pretreatment, and the content of reactive oxygen species (ROS) in the cells was detected by DCFH-DA method after 48 hours of culture.
RESULTS:
Baicalin inhibited the proliferation of DB cells in a dose-dependent manner (r=-0.99), and the IC50 was 20.56 μmol/L at 48 h. The morphological changes of pyroptosis in DB cells were observed under inverted microscope. Compared with the control group, the release of LDH in the baicalin group was significantly increased (P<0.01), indicating the loss of cell membrane integrity. Baicalin dose-dependently increased the expression levels of NLRP3, N-GSDMD, and N-GSDME mRNA and protein in the pyroptosis pathway (P<0.05). Compared with the control group, the level of ROS in the baicalin group was significantly increased (P<0.05), and the content of ROS in the NAC group was significantly decreased (P<0.05). Compared with the NAC group, the content of ROS in the NAC + baicalin group was increased. Baicalin significantly attenuated the inhibitory effect of NAC on ROS production (P<0.05). Similarly, Western blot results showed that compared with the control group, the expression levels of pyroptosis-related proteins was increased in the baicalin group (P<0.05). NAC inhibited the expression of NLRP3 and reduced the cleavage of N-GSDMD and N-GSDME (P<0.05). Compared with the NAC group, the NAC + baicalin group had significantly increased expression of pyroptosis-related proteins. These results indicate that baicalin can effectively induce pyroptosis in DB cells and reverse the inhibitory effect of NAC on ROS production.
CONCLUSION
Baicalin can inhibit the proliferation of DLBCL cell line DB, and its mechanism may be through regulating ROS production to affect the pyroptosis pathway.
Humans
;
NLR Family, Pyrin Domain-Containing 3 Protein/metabolism*
;
Reactive Oxygen Species/pharmacology*
;
Pyroptosis
;
Cell Line
;
RNA, Messenger
;
Lymphoma, Large B-Cell, Diffuse

Result Analysis
Print
Save
E-mail