1.Association study between semen quality and lifestyle in human sperm bank of Anhui Province
Lei GE ; Qing TAN ; Hang LI ; Xiaohong MAO ; Feifei FU ; Bing SONG ; Qunshan SHEN
Acta Universitatis Medicinalis Anhui 2024;59(6):952-957
Objective To examines the correlation between lifestyle factors and semen quality among sperm donors at Anhui human sperm bank.Methods Demographic and lifestyle data were collected from 1,222 volunteers who donated sperm between January 2021 and December 2023,and their association with semen quality was analyzed.Results Univariate chi-square analysis revealed significant associations between several lifestyle factors and abnor-mal semen parameters(P<0.05),including non-student status,frequent masturbation,short-term abstinence,low exercise frequency,frequent staying up late,smoking,drinking,and short sleep duration.Moreover,multiva-riate logistic regression analysis demonstrated that non-student status,longer abstinence time,and insufficient sleep were linked to abnormal semen volume.Additionally,abstinence time,exercise frequency,staying up late,smok-ing,and sleep duration were significantly correlated with abnormal semen concentration and sperm motility(P<0.05).Conclusion Analysis reveals a close relationship between semen quality and volunteers'lifestyles,inclu-ding factors such as abstinence time,staying up late,sleep duration,smoking,drinking,and exercise frequency.
2.Phantom study based on MRI cine sequences: analysis of the accuracy of tumor motion range accuracy
Bing LI ; Yuan WANG ; Ronghu MAO ; Dong LIU ; Wenzheng SUN ; Xiangyue LIU ; Nan MENG ; Wei GUO ; Shuangliang CAO ; Xipan LI ; Chen CHENG ; Hui WU ; Hongyan TAO ; Dingjie LI ; Zhaoyang LOU ; Hongchang LEI ; Lingguang MENG ; Hong GE
Chinese Journal of Radiation Oncology 2024;33(12):1144-1151
Objective:To investigate the accuracy of magnetic resonance imaging (MRI) cine sequences in determining the range of tumor motion in radiotherapy, providing a basis for the precise delineation of the target volume in motion for radiation therapy.Methods:A modified chest motion phantom was placed in a MRI scanner, and a water-filled sphere was used to simulate a tumor. True fast imaging with steady precession (TrueFISP) MRI cine sequences from Siemens were used to capture the two-dimensional motion images of the simulated tumor. The phantom experiments were divided into three modes: head-foot motion mode, rotation motion mode, and actual respiratory waveform mode. In the head-foot motion mode, respiratory motion period (3, 4, 5, 6, 7 and 8 s), amplitude (5, 10 and 15 mm), and respiratory waveform of the simulated tumor (sin and cos4) were set, resulting in a total of 36 motion combinations. In the rotation motion mode, a cos4 waveform was used for respiration, with respiratory periods of 3, 4, 5, 6, 7 and 8 s, head-foot motion set amplitudes of 5, 10 and 15 mm, and anterior-posterior (AP) and left-right (LR) motion set amplitudes in three combinations ([2.5, 2.5] mm, [2.5, 5.0] mm, [5.0, 5.0] mm), resulting in a total of 54 motion combinations. In the actual respiratory waveform mode, respiratory waveforms of 5 randomly selected patients from Affiliated Cancer Hospital of Zhengzhou University were obtained. Under each motion combination, TrueFISP cine images (30 frames, with an acquisition time of 11 s per frame) were obtained. The code was used to automatically identify the two-dimensional coordinates of the center of the simulated tumor in each image, and sin and cos4 functions were separately employed to fit the tumor position in the motion direction, thereby obtaining the fitted motion period and amplitude. The difference between the maximum and minimum values of the tumor's center coordinates in the head-to-foot direction is taken as the range of movement, referred to as the calculated amplitude. For the actual respiratory waveform, the distance between the measured maximum and minimum positions is used to calculate the amplitude.Results:In the head-foot motion mode, the fitted amplitudes of both sin and cos4 waveforms deviated from the set amplitudes by 0-0.51 mm, with relative deviations of 0%-4.2%. The deviation range between the calculated amplitudes and the set amplitudes of the two waveforms were 0.08-0.94 mm, with relative deviations of 1.1%-6.3%. In the rotation motion mode, the fitted amplitudes deviated from the set amplitudes by 0-0.61 mm, with relative deviations of 0%-6.2%. And the deviation range between the calculated amplitudes and the set amplitudes were 0.16-0.94 mm, with relative deviations of 0%-6.3%. In the actual respiratory waveform motion mode, the deviation range between the calculated amplitudes and the set amplitudes were 0.10-0.48 mm, with relative deviations of 2.2%-8.6%.Conclusion:TrueFISP cine sequences show minimal deviations in determining the range of tumor head-foot motion and effectively captures the tumor's movement state, thereby providing important support for the precise definition of the tumor movement target area during radiotherapy .
3.Radiomics based on biparametric MRI for the detection of significant residual prostate cancer after androgen deprivation therapy: using whole-mount histopathology as reference standard.
Zhang-Zhe CHEN ; Wei-Jie GU ; Bing-Ni ZHOU ; Wei LIU ; Hua-Lei GAN ; Yong ZHANG ; Liang-Ping ZHOU ; Xiao-Hang LIU
Asian Journal of Andrology 2023;25(1):86-92
We aimed to study radiomics approach based on biparametric magnetic resonance imaging (MRI) for determining significant residual cancer after androgen deprivation therapy (ADT). Ninety-two post-ADT prostate cancer patients underwent MRI before prostatectomy (62 with significant residual disease and 30 with complete response or minimum residual disease [CR/MRD]). Totally, 100 significant residual, 52 CR/MRD lesions, and 70 benign tissues were selected according to pathology. First, 381 radiomics features were extracted from T2-weighted imaging, diffusion-weighted imaging, and apparent diffusion coefficient (ADC) maps. Optimal features were selected using a support vector machine with a recursive feature elimination algorithm (SVM-RFE). Then, ADC values of significant residual, CR/MRD lesions, and benign tissues were compared by one-way analysis of variance. Logistic regression was used to construct models with SVM features to differentiate between each pair of tissues. Third, the efficiencies of ADC value and radiomics models for differentiating the three tissues were assessed by area under receiver operating characteristic curve (AUC). The ADC value (mean ± standard deviation [s.d.]) of significant residual lesions ([1.10 ± 0.02] × 10-3 mm2 s-1) was significantly lower than that of CR/MRD ([1.17 ± 0.02] × 10-3 mm2 s-1), which was significantly lower than that of benign tissues ([1.30 ± 0.02] × 10-3 mm2 s-1; both P < 0.05). The SVM feature models were comparable to ADC value in distinguishing CR/MRD from benign tissue (AUC: 0.766 vs 0.792) and distinguishing residual from benign tissue (AUC: 0.825 vs 0.835) (both P > 0.05), but superior to ADC value in differentiating significant residual from CR/MRD (AUC: 0.748 vs 0.558; P = 0.041). Radiomics approach with biparametric MRI could promote the detection of significant residual prostate cancer after ADT.
Male
;
Humans
;
Prostatic Neoplasms/drug therapy*
;
Androgen Antagonists/therapeutic use*
;
Androgens
;
Neoplasm, Residual
;
Retrospective Studies
;
Magnetic Resonance Imaging/methods*
;
Diffusion Magnetic Resonance Imaging/methods*
4.A study on the suitability of HD-V2 film in ultra-high dose-rate electron beam dosimetry
Ronghu MAO ; Leijie MA ; Hongchang LEI ; Peng CHEN ; Bing LI ; Hui LUO ; Han LIU ; Xiuyan CHENG ; Wei GUO ; Hong GE
Chinese Journal of Radiation Oncology 2023;32(4):333-338
Objective:To evaluate the usability of Gafchromic HD-V2 film for dose dosimetry in the ultra-high dose-rate (UD) electron beam from a modified medical linac, and to investigate the response between the energy and dose-rate dependence to the film.Methods:The HD-V2 film was utilized to measure the average dose-rate of the UD electron beam. The measured result was compared with those by advanced Markus chamber and alanine pellets. And characteristics of the UD electron beam were also measured by HD-V2 film. Energy dependence of HD-V2 film at three beam energies (6 MV X-ray, 9 MeV and 16 MeV electron beam) was investigated by obtaining and comparing the calibration curves based on the clinical linear accelerator in the dose range of 10-300 Gy. The dose-rate dependence of HD-V2 film was also studied by varying the dose rate among 0.03 Gy/s, 0.06 Gy/s and 0.1 Gy/s, and range of 100-200 Gy/s.Results:The measured average maximum dose-rate of 9 MeV UD electron beam at source skin distance (SSD) 100 cm was approximately 121 Gy/s using HD-V2 film, consistent with the results by advanced Markus chamber and alanine pellets. The measured percentage depth dose (PDD) curve parameters of the UD electron beam were similar to the conventional 9 MeV beam. The off-axis dose distribution of the UD electron beam showed the highest central axis, and the dose was gradually decreased with the increase of off-axis distance. The energy dependence of HD-V2 film had no dependency of 6 MV and 9, 16 MeV while measuring the dose in the range from 20 to 300 Gy. The HD-V2 film had no significant dose-rate dependency at the dose rate of 0.03 Gy/s, 0.06 Gy/s and 0.1 Gy/s for the clinical linear accelerator. Likewise, there was also no dose-rate dependence in the range 100-200 Gy/s in the modified machine.Conclusion:HD-V2 film is suitable for measuring ultra-high dose rate electron beam, independent of energy and dose rate.
5.Transform routine medical accelerators to achieve Flash-RT and physical performance measurements
Leijie MA ; Ronghu MAO ; Hongchang LEI ; Hong GE ; Peng CHEN ; Han LIU ; Bing LI ; Hui LUO
Chinese Journal of Radiation Oncology 2022;31(11):1022-1027
Objective:To investigate the feasibility of transforming conventional medical accelerator to achieve ultra-high dose rate required to achieve Flash radiotherapy (Flash-RT), and to understand the physical properties of the Flash-RT beam.Methods:By transforming the Varian 23CX medical accelerator, the radiation average dose rate at the isocenter was not less than 40 Gy/s. The relevant physical measurement scheme was designed to accurately measure the actual radiation dose rate of different source skin distance (SSD) conditions, the percent depth dose (PDD) curve and the off-axis dose distribution of the beam.Results:The average dose rate of 9 MeV electron beam after the transformation was measured using the HD-V2 type film, the average dose rate of 3 s was 97.9 Gy/s, and the average dose rate of 6 s was 99.27 Gy/s. When the SSD was 100 cm, 80 cm and 60 cm, the average dose rate of 9 MeV electron beam after the transformation was 99.3 Gy/s, 168 Gy/s and 297.5 Gy/s, respectively. After the transformation, the R100 of the 9 MeV beam was 2.2 cm underwater, R50 was 3.87 cm underwater, the electron range Rp was 4.58 cm, and the maximum possible energy Ep,0 on the phantom surface was 9.28 MeV. These parameters were slightly higher than those of the conventional 9 MeV beam, manifested with slight increase in the surface dose and widening high dose flat area. The overall deposit dose distribution exhibited the highest central axis and the increase in dose declines from the axis distance. Under the condition that the field size was 20 cm×20 cm and the SSD was 100 cm, the FWHM of the vertical and horizontal off-axis dose distribution curves were 16.6 cm and 16.4 cm, respectively. Conclusion:By transforming conventional medical accelerator, the average dose rate of the beam at the isocycle meets the requirement of Flash-RT, and the average dose rate under the condition of 60 cm SSD is much higher than the requirement of at least 40 Gy/s for Flash-RT.
6.Mechanism of Xinfeng Capsules improving rheumatoid arthritis based on CD19~+B cells regulating FAK/CAPN/PI3K pathway.
Lei WAN ; Jian LIU ; Chuan-Bing HUANG ; Lei ZHAO ; Xi CHEN ; Hai-Xia FAN ; Yao GE ; Tian-Yang LIU ; Lei LIU ; Zheng LI ; Zi-Heng ZHU ; Xi-Meng MA ; Shu LI
China Journal of Chinese Materia Medica 2021;46(14):3705-3711
To observe the effect of Xinfeng Capsules on rheumatoid arthritis (RA) B lymphocytes,inflammatory mediators,FAK/CAPN/PI3K pathway,in order to explore the mechanism of Xinfeng Capsules in improving clinical symptoms of RA.Joint and systemic symptoms of RA patients were observed,and laboratory indicators[hemoglobin (HGB),platelet count (PLT),erythrocyte sedimentation (ESR),immunoglobulin (Ig) G,Ig A,Ig M,rheumatoid factor (RF),anti-cyclic citrulline antibody (CCP-AB),C-reactive protein (CRP)]were detected.ELISA was used to detect serum interleukin (IL)-1β,IL-10,IL-33,chemokine 5 (CCL5),and vascular endothelial growth factor (VEGF).CD3~-CD19~+B cells were measured by flow cytometry.Western blot was used to detect FAK,p-FAK,CAPN,PI3K protein.The results showed that Xinfeng Capsules could significantly alleviate RA joint and systemic symptoms and improve clinical efficacy.And Xinfeng Capsules could increase HGB,decrease PLT,CCP-AB,CRP,ESR index,upregulate IL-10 expression,and down-regulate IL-1β,IL-33,CCL5,VEGF,CD3~-CD19~+B cells,FAK,p-FAK,CAPN,PI3K expressions (P<0.01).Based on the above results,Xinfeng Capsules may reduce the expression of CD3~-CD19~+,regulate the balance of inflammatory cytokines and chemokines,inhibit abnormal activation of FAK/CAPN/PI3K pathway,and improve clinical symptoms of RA.
Arthritis, Rheumatoid/drug therapy*
;
B-Lymphocytes
;
Capsules
;
Drugs, Chinese Herbal
;
Humans
;
Phosphatidylinositol 3-Kinases
;
Vascular Endothelial Growth Factor A
7.Preliminary study of physical model test and clinical application based on EPID-based in-vivo dose verification system
Ronghu MAO ; Wei GUO ; Bing LI ; Yong ZHANG ; Qingjie WANG ; Xiuyan CHENG ; Hong GE ; Hongchang LEI
Chinese Journal of Radiation Oncology 2021;30(10):1065-1070
Objective:To validate the accuracy of physical model of in-vivo 3D dose verification based on electronic portal imaging device (EPID) using the phantom and preliminarily analyze the clinical application.Methods:Two phantoms (uniform and non-uniform phantoms) were involved in this study. The system of in-vivo 3D dose verification based on EPID was employed to acquire the images of square fields (SF) and combined fields of intensity-modulated radiotherapy (CFIMRT). The physical model of different media was constructed using the system. The factor of γ passing rate under different dose/distance criteria was statistically compared. For clinical cases, the dose-volume histograms were adopted to analyze the dose distribution of target volume and organs at risk (OARs).Results:For the SF in the uniform phantom, the average γ passing rate (3%/3 mm) was (97.49±1.11)%, and (94.06±5.11)% for the SF in the non-uniform phantom ( P>0.05). No statistical significance was noted in IMRT using different delivery methods (all P>0.05). For clinical cases, the average γ passing rate (3%/2 mm) was (97.96±1.84)% in the pre-treatment dose verification, and (90.51±6.96)%(3%/3 mm) for the in-vivo 3D dose verification. For clinical cases, significant dose deviation was observed in OARs with small size and large volume changes. Conclusion:The in-vivo 3D dose verification model based on EPID can be effectively applied in inter-fraction dose verification, providing technical support for adaptive radiotherapy in clinical practice.
8.A study of automatic planning for esophageal cancer with intensity-modulated radiotherapy based on dose prediction and beam angle optimization
Zhaoyang LOU ; Hongchang LEI ; Ronghu MAO ; Wei GUO ; Bing LI ; Hong GE
Chinese Journal of Radiation Oncology 2021;30(12):1275-1279
Objective:To propose an automatic planning method of intensity-modulated radiotherapy (IMRT) for esophageal cancer based on dose volume histogram prediction and beam angle optimization in Raystation treatment planning system.Methods:50 IMRT plans of esophageal cancer were selected as the training set to establish a dose prediction model for organs at risk. Another 20 testing plans were optimized in Raystation using RuiPlan and manual method, and the beam angle optimization and dose volume histogram prediction functions of RuiPlan were used for automatic planning. Dosimetric differences and planning efficiency between two methods were statistically compared with paired t-test. Results:There were no significant dosimetric differences in the conformity index (CI), homogeneity index (HI) of PTV, V 5Gy of both lungs and D max of the spinal cord between automatic and manual plans (all P>0.05). Compared with those in the manual plans, the V 20Gy and D mean of the left and right lungs generated from automatic plans were reduced by 1.1%, 0.37 Gy and 1.2%, 0.38 Gy (all P<0.05), and the V 30Gy, V 40Gy and D mean of the heart in automatic plans were significantly decreased by 5.1%, 3.0% and 1.41 Gy, respectively (all P<0.05). The labor time, computer working time, and monitor unit (MU) number of automatic plans were significantly decreased by 65.8%, 14.1%, and 17.2%, respectively (all P<0.05). Conclusion:RuiPlan automatic planning scripts can improve the efficiency of esophageal cancer planning by dose prediction and beam angle optimization, providing an alternative for esophageal cancer radiotherapy planning.
9.Chinese Trauma Surgeon Association for management guidelines of vacuum sealing drainage application in abdominal surgeries-Update and systematic review.
Yang LI ; Pei-Yuan LI ; Shi-Jing SUN ; Yuan-Zhang YAO ; Zhan-Fei LI ; Tao LIU ; Fan YANG ; Lian-Yang ZHANG ; Xiang-Jun BAI ; Jing-Shan HUO ; Wu-Bing HE ; Jun OUYANG ; Lei PENG ; Ping HU ; Yan-An ZHU ; Ping JIN ; Qi-Feng SHAO ; Yan-Feng WANG ; Rui-Wu DAI ; Pei-Yang HU ; Hai-Ming CHEN ; Ge-Fei WANG ; Yong-Gao WANG ; Hong-Xu JIN ; Chang-Ju ZHU ; Qi-Yong ZHANG ; Biao SHAO ; Xi-Guang SANG ; Chang-Lin YIN
Chinese Journal of Traumatology 2019;22(1):1-11
Vacuum sealing drainage (VSD) is frequently used in abdominal surgeries. However, relevant guidelines are rare. Chinese Trauma Surgeon Association organized a committee composed of 28 experts across China in July 2017, aiming to provide an evidence-based recommendation for the application of VSD in abdominal surgeries. Eleven questions regarding the use of VSD in abdominal surgeries were addressed: (1) which type of materials should be respectively chosen for the intraperitoneal cavity, retroperitoneal cavity and superficial incisions? (2) Can VSD be preventively used for a high-risk abdominal incision with primary suture? (3) Can VSD be used in severely contaminated/infected abdominal surgical sites? (4) Can VSD be used for temporary abdominal cavity closure under some special conditions such as severe abdominal trauma, infection, liver transplantation and intra-abdominal volume increment in abdominal compartment syndrome? (5) Can VSD be used in abdominal organ inflammation, injury, or postoperative drainage? (6) Can VSD be used in the treatment of intestinal fistula and pancreatic fistula? (7) Can VSD be used in the treatment of intra-abdominal and extra-peritoneal abscess? (8) Can VSD be used in the treatment of abdominal wall wounds, wound cavity, and defects? (9) Does VSD increase the risk of bleeding? (10) Does VSD increase the risk of intestinal wall injury? (11) Does VSD increase the risk of peritoneal adhesion? Focusing on these questions, evidence-based recommendations were given accordingly. VSD was strongly recommended regarding the questions 2-4. Weak recommendations were made regarding questions 1 and 5-11. Proper use of VSD in abdominal surgeries can lower the risk of infection in abdominal incisions with primary suture, treat severely contaminated/infected surgical sites and facilitate temporary abdominal cavity closure.
Abdomen
;
surgery
;
China
;
Drainage
;
methods
;
Evidence-Based Medicine
;
Humans
;
Practice Guidelines as Topic
;
Societies, Medical
;
organization & administration
;
Surgical Wound Infection
;
prevention & control
;
Traumatology
;
organization & administration
;
Vacuum
10.Effect of IL-8 on the Immune Function of Patients with Acute -Lymphoblastic Leukemia and Its Mechanism.
Bing-Lei GE ; Ji-Wei JIN ; Cong-Yao LIU ; Gan YIN ; Dan XIAO ; Xue-Jun HONG
Journal of Experimental Hematology 2018;26(6):1621-1625
OBJECTIVE:
To investigate the effect of interleukin -8 (IL-8) on immune function in acute lymphoblastic leukemia patients and its related mechanisms.
METHODS:
Forty-five ALL patients were selected from January 2014 to September 2017 in our hospital. Out of them, 32 relieved patients were included in group A, 13 patients did not relieved patients after treatment and were included in the group B. The serum IL-8 level was detected by ELISA.Th1 and Th2 cells were measured by flow cytometry. After Th cells were treated with different concentration of IL-8, the Western blot was used to detect the translation levels of p-STAT3 and JAK in cells.
RESULTS:
The difference of white blood cell count and clinical risk level between the 2 groups was statistically significant (P<0.05). The serum IL-8 levels in group A and B were significantly higher than that in control group (P<0.05). The serum IL-8 level in group B was significantly higher than that in group A (P<0.05). After treatment, the level of Th1 cells in group B was 6.15%±1.22%, significantly lower than that in group A (P<0.05), and Th2 cell level in group B was 2.76%±0.24%, significantly higher than that in group A (P<0.05); Th1/Th2 in group B was 2.23%±0.09, significantly lower than that in group A (P<0.05). The protein level of p-STAT3 and JAK in the Th cells was lower than that in control group at different levels of IL-8 after treatment (P<0.05). After stimulating Th cells with 20 ng/ml IL-8, the levels of p-STAT3 and JAK protein in cells were lower than those after 10 ng/ml IL-8 treatment (P<0.05). IL-8 level had no significant effect on the protein expression of STAT3 in Th cells (P>0.05).
CONCLUSION
IL-8 can interfere the balance of Th1/Th2 through STAT3 signaling pathway, and has effect on the immune function of ALL patients.
Humans
;
Interferon-gamma
;
Interleukin-8
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma
;
Th1 Cells
;
Th2 Cells


Result Analysis
Print
Save
E-mail