1.Correlation analysis of central venous oxygen saturation-related indexes at different time points with low cardiac output syndrome in children after congenital heart disease correction surgery
Jingxiao LI ; Yunkai CAI ; Binfeng LEI ; Wei LU ; Liqin MO ; Weifeng HUANG ; Chaohai LYV ; Liuying QIN ; Jingwei JIANG ; Ting ZHOU
Chongqing Medicine 2025;54(5):1155-1160
Objective To explore the correlation between central venous oxygen saturation(ScvO2)-re-lated indexes at different time points and the occurrence of low cardiac output syndrome(LCOS)after con-genital heart disease(CHD)correction surgery.Methods A total of 73 children who underwent CHD correc-tion surgery in this hospital from July 1st,2021 to July 1st,2024 were selected as the research subjects.The clinical data,preoperative conditions,and postoperative conditions of the children were collected.The ScvO2 and arterial lactate(Lac)levels of the children at different time points(the 1st,6th,12th,and 24th hours after surgery)were monitored,and the ScvO2/Lac at different time points and the change rate of ScvO2 in different time periods were calculated.The correlation between ScvO2-related indexes and LCOS after CHD correction surgery was analyzed.Results ScvO2 at the 6th hour after surgery,ScvO2 at the 12th hour after surgery,Sc-vO2/Lac at the 12th hour after surgery,the change rate of ScvO2 from the 1st to the 24th hour after surgery,the change rate of ScvO2 from the 6th to the 12th hour after surgery,and the change rate of ScvO2 from the 12th to the 24th hour after surgery were independent influencing factors of LCOS occurrence after CHD cor-rection surgery(P<0.05).There was a negative correlation between ScvO2 at the 12th hour after surgery,ScvO2/Lac and LCOS occurrence after CHD correction surgery(r=-0.543,-0.523,P<0.05).The area under the curve(AUC)of ScvO2 at the 12th hour after surgery for predicting LCOS occurrence after CHD correction surgery was 0.938(95%CI:0.865-1.000);the AUC of ScvO2/Lac at the 12th hour after surgery for predicting LCOS occurrence after CHD correction surgery was 0.922(95%CI:0.851-0.994).Conclusion ScvO2 and ScvO2/Lac at the 12th hour after surgery have good predictive potential for LCOS occurrence af-ter CHD correction surgery.
2.Effect of combined catheter ablation of atrial fibrillation and left atrial appendage closure on left atrial structure compared with a single procedure.
Zhentao FEI ; Ming LIU ; Pengcheng YAO ; Mingzhe ZHAO ; Changqi GONG ; Mu CHEN ; Yudong FEI ; Binfeng MO ; Rui ZHANG ; Yichi YU ; Yuli YANG ; Qian WANG ; Wei LI ; Pengpai ZHANG ; Jian SUN ; Qunshan WANG ; Yigang LI
Chinese Medical Journal 2023;136(24):3010-3012
3.Simulation Results and Analysis of Electric Field Distribution in Myocardial Tissue under Circular Electrode Electric Pulse Ablation.
Wencai WANG ; Qunshan WANG ; Binfeng MO ; Jinhai NIU
Chinese Journal of Medical Instrumentation 2023;47(3):242-246
As a new energy source for atrial fibrillation ablation, electric pulse ablation has higher tissue selectivity and biosafety, so it has a great application prospect. At present, there is very limited research on multi-electrode simulated ablation of histological electrical pulse. In this study, a circular multi-electrode ablation model of pulmonary vein will be built on COMSOL5.5 platform for simulation research. The results show that when the voltage amplitude reaches about 900 V, it can make some positions achieve transmural ablation, and the depth of continuous ablation area formed can reach 3 mm when the voltage amplitude reaches 1 200 V. When the distance between catheter electrode and myocardial tissue is increased to 2 mm, a voltage of at least 2 000 V is required to make the depth of continuous ablation area reach 3 mm. Through the simulation of electric pulse ablation with ring electrode, the research results of this project can provide reference for the voltage selection in the clinical application of electric pulse ablation.
Humans
;
Heart Rate
;
Atrial Fibrillation/surgery*
;
Electrodes
;
Catheter Ablation
;
Electricity
4.CT Image-based Surgery Assist System for Left Atrial Appendage Occlusion.
Bai CONG ; Qunshan WANG ; Binfeng MO ; Jinhai NIU
Chinese Journal of Medical Instrumentation 2021;45(4):355-360
At present, the standard left atrial appendage occlusion procedure mainly involves two-dimensional imaging methods such as X-ray fluoroscopy and transesophageal echocardiography to guide the operation, which will lead to underestimation of the three dimensional structure of the left atrial appendage and the surrounding tissue, thus adversely affects the surgery. To solve this problem, a surgery assist system for left atrial appendage occlusion based on preoperative cardiac CT images is developed. The proposed system realizes the left atrial appendage parameter measurement based on cardiac CT image, and realizes the calculation of optimal delivery sheath trajectory and three-dimensional simulation of the delivery sheath movement on the basis of a novel delivery sheath trajectory model. The system is expected to provide precise guidance for left atrial appendage occlusion, improve the success rate and safety of the operation, and at the same time help reduce the difficulty of learning the operation, and facilitate the promotion of left atrial appendage occlusion.
Atrial Appendage/surgery*
;
Atrial Fibrillation/surgery*
;
Cardiac Catheterization
;
Echocardiography, Transesophageal
;
Humans
;
Tomography, X-Ray Computed
;
Treatment Outcome

Result Analysis
Print
Save
E-mail