1.Multidimensional Innovation for medical-rehabilitation integration
Bin LIAN ; Lin ZHOU ; Qinfeng WU ; Jiajia WANG ; Wei LU ; Guoen FANG
Chinese Journal of Rehabilitation Theory and Practice 2026;32(1):40-44
ObjectiveTo conduct a theoretical study on the medical-rehabilitation integration. MethodsStarting from the background, objectives and content of the medical-rehabilitation integration, this study analyzed its innovative points from the dimensions of conceptual innovation, organizational innovation, model innovation and technological innovation. Results and ConclusionThe medical-rehabilitation integration is an innovation in medical services that takes conceptual innovation as the forerunner, organizational innovation as the foundation, model innovation as the carrier and technological innovation as the core.
2.Influencing Factors of Urate Crystal Deposition in Patients with Hyperuricemia and Prediction Model of TCM Syndrome Types-inflammatory Indicators
Jiaqi XU ; Bin AI ; Chao LIN ; Qiaoxuan LIN ; Changning LI ; Jing CAI ; Yan XIAO ; Jiemei GUO ; Youxin SU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(7):66-73
ObjectiveTo identify potential influencing factors of urate crystal deposition at ankle/foot in patients with hyperuricemia (HUA), and to analyze the predictive value of inflammatory indicators for urate crystal deposition in patients with different traditional Chinese medicine (TCM) syndromes, so as to provide potential reference for clinical risk assessment and individualized TCM intervention. MethodsA retrospective study was carried out with the enrollment of 231 HUA patients from The Third Affiliated People's Hospital of Fujian University of Traditional Chinese Medicine between January 2021 and December 2024. The enrolled patients were further divided into a crystal deposition-positive group (143 cases) and a crystal deposition-negative group (88 cases) according to the results of dual-energy computed tomography (CT). Sociodemographic data, living habits, serum uric acid levels, and inflammatory indicators of the enrolled patients were collcted, and TCM syndrome differentiation was performed. Furthermore, univariate analysis was used to compare inter-group differences in clinical characteristics. MMultivariate Logistic regression was applied to identify the influencing factors of urate crystal deposition. In addition, the receiver operating characteristic (ROC) curves were plotted to evaluate the predictive efficacy of inflammatory indicators for crystal deposition across different TCM syndromes. ResultsThere were statistically significant inter-group differences in the proportion of males, age, body mass index, proportion of mental labor, rate of low water intake, and rate of high-sugar beverage consumption (P<0.05),whereas no significant difference in low exercise intensity was found between the two groups. Furthermore, compared with the negative group, the positive group had higher serum uric acid level, neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR), but lower systemic immune-inflammation index (SIRI) (P<0.05). Regarding the distribution of TCM syndromes, the positive group was dominated by the dampness-heat accumulation syndrome (55/143,38.46%), while the negative group was mainly characterized by the phlegm-turbidity obstruction syndrome (44/88,50.00%). Multivariate Logistic regression analysis revealed that high-sugar beverage consumption, elevated NLR, and elevated PLR were risk factors for urate crystal deposition [odd ratio (OR) = 8.002, 5.377, 1.034, respectively; 95% CI 1.572-40.732, 2.179-13.270, 1.013-1.054,all P<0.05], while SIRI was a protective factor (OR = 0.869, 95% CI 0.778-0.971, P<0.05). In the positive group, patients with the dampness-heat accumulation syndrome exhibited the highest NLR, while the lowest PLR and SIRI, showing statistically significant differences with those of other syndromes (all P<0.05). In addition, ROC curve analysis indicated that for the dampness-heat accumulation syndrome, the combined "NLR + PLR" model had an area under the curve (AUC) of 0.901 (95% CI 0.850-0.951, P<0.01), with a sensitivity of 89.1% and a specificity of 79.5%; for the blood stasis-heat obstruction syndrome, the combined "NLR + PLR" model had an AUC of 0.880 (95% CI 0.825-0.934, P<0.01), with a sensitivity of 100.0% and a specificity of 67.3%; for the liver-kidney Yin-deficiency syndrome, the single PLR model had an AUC of 0.842 (95% CI 0.731-0.952, P<0.01), with a sensitivity of 83.3% and a specificity of 84.0%. ConclusionUrate crystal deposition in HUA patients exhibits intimate associations with high-sugar beverage consumption as well as elevated NLR and PLR levels. Meanwhile, TCM syndrome differentiation has potential correlation with inflammatory characteristics. The inflammatory indicator-based prediction model constructed based on TCM syndromes exhibits good predictive value.
3.Finite element analysis of internal fixation with new retrograde intramedullary nail on lateral femur condyle for distal type A2 femur fractures
Xinlin YU ; Huiyu CHEN ; Yingying WANG ; Weizhong GUO ; Bin FENG ; Chengshou LIN ; Wang LIN
Chinese Journal of Tissue Engineering Research 2026;30(3):546-552
BACKGROUND:Plate fixation is the mainstream method for the surgical treatment of distal femoral fractures.The intramedullary nailing has the advantages of minimally invasive,such as less soft tissue injury and bone blood supply destruction.At the same time,it is a central fixation and has better biomechanical effect.Therefore,retrograde intramedullary nailing has become another option for the internal fixation of distal femoral fractures.OBJECTIVE:The biomechanical characteristics of new retrograde intramedullary nail on lateral femur condyle,common femoral retrograde intramedullary nail,and lateral femur condyle anatomical locking plate for the treatment of A2-type distal femoral fractures were compared using finite element analysis,and the advantages of new retrograde intramedullary nail on lateral femur condyle was studied.METHODS:A new retrograde intramedullary nail on lateral femur condyle was designed,which was inserted into the bone cortex in front of the insertion point of the lateral collateral ligament of the lateral femoral condyle.A CT scan was performed on the lower limb bone of a male volunteer,and a three-dimensional model of the femur was established.The model was then segmented to create a three-dimensional model of a femoral distal A2-type fracture,The three-dimensional models of small(small group),standard type retrograde intramedullary nail on the lateral femoral condyle(standard group),common retrograde intramedullary needle(common group),and lateral femur condyle anatomical locking plate(plate group)were established respectively.The axial stresses of 600,1 800 N and the torsional load of 4 000,8 000 N·mm were applied to the models,and the displacement and stress of femur and the displacement,stress and shear force of internal fixators were observed in each group.RESULTS AND CONCLUSION:(1)When subjected to axial load of 600 and 1 800 N,the femoral peak displacement,the femoral peak stress,and the peak stress of interal fixation in the standard group were the lowest among the four groups.(2)When subjected to torsional load of 4 000 and 8 000 N·mm,the femoral peak displacement and peak displacement of the internal fixation in the standard group were the lowest among the four groups.(3)Compared with femoral lateral condylar locking plate and common retrograde intramedullary needle,the new retrograde intramedullary needle on lateral femur condyle has mechanical advantages of reducing stress concentration and decreasing the risk of internal fixation failure.
4.Finite element analysis of internal fixation with new retrograde intramedullary nail on lateral femur condyle for distal type A2 femur fractures
Xinlin YU ; Huiyu CHEN ; Yingying WANG ; Weizhong GUO ; Bin FENG ; Chengshou LIN ; Wang LIN
Chinese Journal of Tissue Engineering Research 2026;30(3):546-552
BACKGROUND:Plate fixation is the mainstream method for the surgical treatment of distal femoral fractures.The intramedullary nailing has the advantages of minimally invasive,such as less soft tissue injury and bone blood supply destruction.At the same time,it is a central fixation and has better biomechanical effect.Therefore,retrograde intramedullary nailing has become another option for the internal fixation of distal femoral fractures.OBJECTIVE:The biomechanical characteristics of new retrograde intramedullary nail on lateral femur condyle,common femoral retrograde intramedullary nail,and lateral femur condyle anatomical locking plate for the treatment of A2-type distal femoral fractures were compared using finite element analysis,and the advantages of new retrograde intramedullary nail on lateral femur condyle was studied.METHODS:A new retrograde intramedullary nail on lateral femur condyle was designed,which was inserted into the bone cortex in front of the insertion point of the lateral collateral ligament of the lateral femoral condyle.A CT scan was performed on the lower limb bone of a male volunteer,and a three-dimensional model of the femur was established.The model was then segmented to create a three-dimensional model of a femoral distal A2-type fracture,The three-dimensional models of small(small group),standard type retrograde intramedullary nail on the lateral femoral condyle(standard group),common retrograde intramedullary needle(common group),and lateral femur condyle anatomical locking plate(plate group)were established respectively.The axial stresses of 600,1 800 N and the torsional load of 4 000,8 000 N·mm were applied to the models,and the displacement and stress of femur and the displacement,stress and shear force of internal fixators were observed in each group.RESULTS AND CONCLUSION:(1)When subjected to axial load of 600 and 1 800 N,the femoral peak displacement,the femoral peak stress,and the peak stress of interal fixation in the standard group were the lowest among the four groups.(2)When subjected to torsional load of 4 000 and 8 000 N·mm,the femoral peak displacement and peak displacement of the internal fixation in the standard group were the lowest among the four groups.(3)Compared with femoral lateral condylar locking plate and common retrograde intramedullary needle,the new retrograde intramedullary needle on lateral femur condyle has mechanical advantages of reducing stress concentration and decreasing the risk of internal fixation failure.
5.Implementing standardized school desks and chairs to promote the healthy development of primary and secondary school students
ZHANG Fengyun, SONG Yi, ZHANG Lin, LUO Chunyan, DU Wei, DONG Bin
Chinese Journal of School Health 2025;46(3):305-309
Abstract
In order to understand and analyze the current standards and application of school desks and chairs for primary and secondary schools, and to promote the healthy growth of primary and secondary school students. The article conducts a comprehensive review of the functional and dimensional standards for school furniture both domestically and internationally, and objectively analyzes the current utilization and existing issues concerning desks and chairs in schools. It further explores the multifaceted factors that influence the allocation of desks and chairs, and proposes effective countermeasures, so as to provide a reference for the risk factors of common diseases related to desks and chairs, such as myopia and abnormal spinal curvature.
6.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs.
7.Analysis of distortion product otoacoustic emissions results of noise-exposed workers at a metal shipbuilding enterprise
Jieting ZHOU ; Jianyu GUO ; Hairu YANG ; Linyan SHU ; Zhixing FAN ; Jia TANG ; Xinqiang NIE ; Guoyong XU ; Hansheng LIN ; Bin XIAO
China Occupational Medicine 2025;52(1):99-105
Objective To evaluate the role of distortion product otoacoustic emissions (DPOAE) testing in evaluating early hearing loss among noise-exposed workers. Methods A total of 174 noise-exposed workers in a metal shipbuilding enterprise were selected as the research subjects by the convenience sampling method. Pure tone audiometry (PTA), DPOAE and the level of noise exposure were conducted on the workers. The rank correlation analysis was used to analyze the correlation between DPOAE amplitude and PTA threshold. The multilevel model was used to analyze the effects of gender, age, noise exposure intensity, cumulative noise exposure (CNE), hearing loss classification and PTA threshold on DPOAE results. Results At the frequencies of 0.50, 1.00, 2.00, 3.00, 4.00, 6.00 and 8.00 kHz, the DPOAE amplitude was negatively correlated with the PTA threshold (rank correlation coefficients were -0.12, -0.48, -0.47, -0.18, -0.23, -0.44, -0.19, respectively, all P<0.01). At the most frequencies, DPOAE amplitude was negatively correlated with age and CNE (all P<0.05). The results of multilevel model analysis showed that there were significant differences in DPOAE amplitudes at certain frequencies across gender, age, noise intensity, CNE, and hearing loss classification (all P<0.05). Significant differences in DPOAE responses were found among different CNE and hearing loss groups (all P<0.01). Conclusion DPOAE testing can objectively reflect the hearing status of noise-exposed workers and could be considered for inclusion in routine hearing monitoring to facilitate early detection of noise-induced hearing loss.
8.Identification of Alumen and Ammonium alum Based on XRD, FTIR, TG-DTA Combined with Chemometrics
Bin WANG ; Jingwei ZHOU ; Huangsheng ZHANG ; Jian FENG ; Hanxi LI ; Guorong MEI ; Jiaquan JIANG ; Hongping CHEN ; Fu WANG ; Yuan HU ; Youping LIU ; Shilin CHEN ; Lin CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):178-186
ObjectiveTo establish the multi-technique characteristic profiles of Alumen by X-ray diffraction(XRD), Fourier-transform infrared spectroscopy(FTIR) and thermogravimetric-differential thermal analysis(TG-DTA), and to explore the spectral characteristics for rapid identification of Alumen and its potential adulterant, Ammonium alum. MethodsA total of 27 batches of Alumen samples from 8 production regions were collected for preliminary identification based on visual characteristics. The PDF standard cards of XRD were used to differentiate Alumen from A. alum, and the XRD characteristic profiles of Alumen were established, and then the common peaks were screened. Based on hierarchical clustering analysis(HCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA), the characteristic information that could be used for identification of Alumen was selected with variable importance in the projection(VIP) value>1. FTIR characteristic profiles of Alumen were established, and key wavenumbers for identification were screened by HCA and OPLS-DA with VIP value>1. Meanwhile, the thermogravimetric differences between Alumen and A. alum were analyzed by TG-DTA, and the thermogravimetric traits that could be used for identification were screened. ResultsAlumen and A. alum could not be effectively distinguished by traits alone. However, by comparing the PDF standard cards of XRD, 15 batches of Alumen and 12 batches of A. alum could be distinguished. In the XRD profiles, 10 characteristic peaks were confirmed, corresponding to diffraction angles of 14.560°, 24.316°, 12.620°, 32.122°, 17.898°, 34.642°, 27.496°, 46.048°, 40.697° and 21.973°. In the FTIR profiles, 4 wavenumber ranges(399.193-403.050, 1 186.010-1 471.420, 1 801.190-2 620.790, 3 612.020-3 997.710 cm-1) and 12 characteristic wavenumbers(1 428.994, 1 430.922, 1 432.851, 1 434.779, 1 436.708, 1 438.636, 1 440.565, 1 442.493, 1 444.422, 1 446.350, 1 448.279, 1 450.207 cm-1) were identified. In the TG-DTA profiles, there were characteristic decomposition peaks of ammonium ion and mass reduction features near 555.34 ℃ for A. alum. These characteristics could serve as important criteria for distinguishing the authenticity of Alumen. ConclusionXRD, FTIR and TG-DTA can be used to rapidly detect Alumen and A. alum, and combined with the discriminant features selected through chemometrics, the rapid and accurate identification of Alumen and A. alum can be achieved. The research findings provide new approaches for the rapid identification of Alumen.
9.Identification of Alumen and Ammonium alum Based on XRD, FTIR, TG-DTA Combined with Chemometrics
Bin WANG ; Jingwei ZHOU ; Huangsheng ZHANG ; Jian FENG ; Hanxi LI ; Guorong MEI ; Jiaquan JIANG ; Hongping CHEN ; Fu WANG ; Yuan HU ; Youping LIU ; Shilin CHEN ; Lin CHEN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):178-186
ObjectiveTo establish the multi-technique characteristic profiles of Alumen by X-ray diffraction(XRD), Fourier-transform infrared spectroscopy(FTIR) and thermogravimetric-differential thermal analysis(TG-DTA), and to explore the spectral characteristics for rapid identification of Alumen and its potential adulterant, Ammonium alum. MethodsA total of 27 batches of Alumen samples from 8 production regions were collected for preliminary identification based on visual characteristics. The PDF standard cards of XRD were used to differentiate Alumen from A. alum, and the XRD characteristic profiles of Alumen were established, and then the common peaks were screened. Based on hierarchical clustering analysis(HCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA), the characteristic information that could be used for identification of Alumen was selected with variable importance in the projection(VIP) value>1. FTIR characteristic profiles of Alumen were established, and key wavenumbers for identification were screened by HCA and OPLS-DA with VIP value>1. Meanwhile, the thermogravimetric differences between Alumen and A. alum were analyzed by TG-DTA, and the thermogravimetric traits that could be used for identification were screened. ResultsAlumen and A. alum could not be effectively distinguished by traits alone. However, by comparing the PDF standard cards of XRD, 15 batches of Alumen and 12 batches of A. alum could be distinguished. In the XRD profiles, 10 characteristic peaks were confirmed, corresponding to diffraction angles of 14.560°, 24.316°, 12.620°, 32.122°, 17.898°, 34.642°, 27.496°, 46.048°, 40.697° and 21.973°. In the FTIR profiles, 4 wavenumber ranges(399.193-403.050, 1 186.010-1 471.420, 1 801.190-2 620.790, 3 612.020-3 997.710 cm-1) and 12 characteristic wavenumbers(1 428.994, 1 430.922, 1 432.851, 1 434.779, 1 436.708, 1 438.636, 1 440.565, 1 442.493, 1 444.422, 1 446.350, 1 448.279, 1 450.207 cm-1) were identified. In the TG-DTA profiles, there were characteristic decomposition peaks of ammonium ion and mass reduction features near 555.34 ℃ for A. alum. These characteristics could serve as important criteria for distinguishing the authenticity of Alumen. ConclusionXRD, FTIR and TG-DTA can be used to rapidly detect Alumen and A. alum, and combined with the discriminant features selected through chemometrics, the rapid and accurate identification of Alumen and A. alum can be achieved. The research findings provide new approaches for the rapid identification of Alumen.
10.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.


Result Analysis
Print
Save
E-mail