1.Anatomical structures of the matrix channel network for interstitial fluid flow in the human hand
Tian-Tian LI ; Jian-Ping ZHAO ; Chao-Zhi YANG ; Zhen CHEN ; Nai-Li WANG ; Bei LI ; Jin CAI ; Xiao-Yu WANG ; Hong-Yi LI
Acta Anatomica Sinica 2025;56(3):307-314
Objective To investigate the anatomical and microscopic structures of interstitial fluid flow channels in the skin tissue of hand dorsum in human cadavers.Methods Totally 7 fresh cadavers within 12 hours post-mortem were included.MRI was used to observe the distribution of interstitial fluid flow from the first phalanx of the fingers to the wrist,precisely locating the flow channels.Based on imaging results,histological analyses were conducted to determine the histological characteristics of the flow channels.Furthermore,multi-immunofluorescence and microcomputed tomography(Micro-CT)techniques were employed to analyze the channels,and image post-processing was used to elucidate their anatomical structures at the microscopic level.Results After injecting a contrast agent into the first phalanx of ten finger specimens and applying repeated pressure,MRI image revealed centripetal long-range interstitial fluid flow along channels distinct from blood vessels and lymphatic vessels.Histological analysis and Micro-CT further confirmed that the flow primarily occurred within the fibrous connective tissue and adventitia of the skin.Conclusion The orderly fibrous connective tissue and adventitia in the skin form the interstitial fluid flow channels in the human hand dorsum skin,named as"stromal membrane channels"in the skin.
2.Long-term follow-up of percutaneous pulmonary valve implantation using domestic self-expanding valve-prospective single-center experience
Qian-bei HE ; Qiao LI ; Yi-jian LI ; Rui-tao LI ; Bo-feng CHAI ; Zhi-cheng CHEN ; Zhi-xiang YU ; Zhen-gang ZHAO ; Yuan FENG
Chinese Journal of Interventional Cardiology 2025;33(5):241-248
Objective To explore the long-term efficacy of percutaneous pulmonary valve implantation(PPVI)and the durability of the domestic self-expanding Venus P valve.Methods A total of 8 patients with post-surgical right ventricular outflow tract(RVOT)dysfunction,who were admitted to hospital from October 2014 to July 2016 and deemed anatomically suitable for PPVI with self-expanding valve,were included prospectively.Clinical,imaging,procedural and follow-up data were analyzed.The survival rates,perioperative and long-term complication rates,long-term efficacy of PPVI,and long-term function of Venus P in 8 patients were evaluated.The immediate procedural results were evaluated by clinical implant success rate,which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation<moderate and peak trans-pulmonary pressure gradient<40 mmHg.Results A total of 8 patients were included,with 7 females,aged 14 to 36 years.The initial diagnosis included post-surgical Tetralogy of Fallot(5 cases),post-surgical Trilogy of Fallot(1 case),post-surgical Quadricuspid pulmonary valve stenosis(1 case)and post-surgical Double-Outlet Right Ventricle(1 case).The indications of PPVI included RVOT-pulmonary obstruction and regurgitation(1 case)and isolated regurgitation(7 cases).Clinical implant success was achieved in all of the 8 patients with firmly fixed valve,and there were no such complications as valve detachment,displacement or stent fracture.All patients experienced significant symptom relief after the procedure.The right ventricular end-diastolic volume index(RVEDVi)measured by CMR 6 months after PPVI showed a significant decrease compared to preprocedural values[(89.99±13.85)ml/m2 vs.(144.93±11.28)ml/m2,P=0.001].Postoperative pulmonary regurgitation were significantly improved or disappeared in all patients,and there was no statistically significant difference in the average peak pressure gradient measured by echocardiogram between preoperative and the latest follow-up[(23.25±8.39)mmHg vs.(18.75±6.28)mmHg,P=0.210].Over an average follow-up period of(9.25±0.71)years,1 case of infective endocarditis occurred 5 years after PPVI.During the follow-up,no death,deterioration of heart failure,malignant arrhythmia or other serious complications were observed.All patients completed 8-year follow-up,and 3 completed 10-year follow-up.All patients were graded as NYHA functional class one at the latest follow-up.Conclusions PPVI using the domestically produced self-expanding Venus P is safe and feasible for the treatment of patients with post-surgical RVOT dysfunction and suitable anatomy.Our study confirms the long-term efficacy and durability of Venus P from multiple perspectives,and no severe stent fracture occurred without pre-stent implantation in the native RVOT.
3.Evolution of indications for percutaneous pulmonary valve implantation
Qian-bei HE ; Yuan FENG ; Zhen-gang ZHAO
Chinese Journal of Interventional Cardiology 2025;33(5):278-283
Patients with congenital heart disease combined with right ventricular outflow tract malformations often leave varying degrees of pulmonary regurgitation and/or obstruction after surgical/interventional correction.With the continuation of time,the significant increasement of the right ventricular volume load will affect patients'quality of life and survival,which may require multiple pulmonary valve replacements.Compared with high-risk surgery,percutaneous pulmonary valve implantation is a less invasive,safer and more effective interventional valve replacement technology,which can improve patients' long-term prognosis.With the progress of technology and the improvement of instruments,the indications of percutaneous pulmonary valve implantation have gradually expanded,and have gradually become an alternative treatment of surgical thoracic valve replacement.Combined with the latest research progress of percutaneous pulmonary valve implantation,this paper discusses the change of indications,optimal timing of intervention and instrument selection in recent years.
4.Effects of different CO2 pneumoperitoneum pressures on overweight or obese patients with laparoscopic panhysterectomy in Trendelenburg position
Hao WANG ; Ke GU ; Li-hua RAO ; Bei HU ; Wei-wei JI ; Zhen TIAN ; Ti-jun DAI
Journal of Regional Anatomy and Operative Surgery 2025;34(2):150-153
Objective To explore the effects of different CO2 pneumoperitoneum pressures during surgery on overweight or obese patients with laparoscopic panhysterectomy in Trendelenburg position.Methods A total of 88 overweight or obese patients who underwent laparoscopic panhysterectomy were selected and randomly divided into the low-pressure group and the high-pressure group according to random number table method,with 44 patients in each group.All patients used CO2 as the pneumoperitoneum medium during surgery,with 10 mmHg of CO2 pneumoperitoneum pressure in the low-pressure group and 15 mmHg of CO2 pneumoperitoneum pressure in the high-pressure group.The operation-related indexes,respiratory indicators,nasopharyngeal temperature and adverse reactions of patients were compared between the two groups.Results There was no significant difference in the surgical time,blood loss,intraoperative infusion volume,incidence of organ injury,and laparotomy rate between the two groups(P>0.05).The recovery time of anesthesia of patients in the low-pressure group was shorter than that in the high-pressure group(P<0.05).At 30 minutes after the establishment of pneumoperitoneum,the peak airway pressure(Ppeak)and plateau pressure(Pplat)of patients in the high-pressure group were significantly higher than those in the low-pressure group(P<0.05),while the dynamic lung compliance(Cdyn)of patients in the high-pressure group was significantly lower than that in the low-pressure group(P<0.05).At 60 minutes after the establishment of pneumoperitoneum and the end of pneumoperitoneum,the nasopharyngeal temperature of patients in the high-pressure group were significantly lower than those in the low-pressure group(P<0.05).The incidences of intraoperative hypothermia and shivering in the high-pressure group were significantly higher than those in the low-pressure group(P<0.05).Conclusion Compared with 15 mmHg of CO2 pneumoperitoneum pressure,10 mmHg of CO2 pneumoperitoneum pressure on overweight or obese patients with laparoscopic panhysterectomy in Trendelenburg position does not increase surgical difficulty,and the patients has lower airway pressure,better lung compliance,fewer adverse reactions,and faster recovery,which can also avoid intraoperative hypothermia.
5.Long-term follow-up of percutaneous pulmonary valve implantation using domestic self-expanding valve-prospective single-center experience
Qian-bei HE ; Qiao LI ; Yi-jian LI ; Rui-tao LI ; Bo-feng CHAI ; Zhi-cheng CHEN ; Zhi-xiang YU ; Zhen-gang ZHAO ; Yuan FENG
Chinese Journal of Interventional Cardiology 2025;33(5):241-248
Objective To explore the long-term efficacy of percutaneous pulmonary valve implantation(PPVI)and the durability of the domestic self-expanding Venus P valve.Methods A total of 8 patients with post-surgical right ventricular outflow tract(RVOT)dysfunction,who were admitted to hospital from October 2014 to July 2016 and deemed anatomically suitable for PPVI with self-expanding valve,were included prospectively.Clinical,imaging,procedural and follow-up data were analyzed.The survival rates,perioperative and long-term complication rates,long-term efficacy of PPVI,and long-term function of Venus P in 8 patients were evaluated.The immediate procedural results were evaluated by clinical implant success rate,which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation<moderate and peak trans-pulmonary pressure gradient<40 mmHg.Results A total of 8 patients were included,with 7 females,aged 14 to 36 years.The initial diagnosis included post-surgical Tetralogy of Fallot(5 cases),post-surgical Trilogy of Fallot(1 case),post-surgical Quadricuspid pulmonary valve stenosis(1 case)and post-surgical Double-Outlet Right Ventricle(1 case).The indications of PPVI included RVOT-pulmonary obstruction and regurgitation(1 case)and isolated regurgitation(7 cases).Clinical implant success was achieved in all of the 8 patients with firmly fixed valve,and there were no such complications as valve detachment,displacement or stent fracture.All patients experienced significant symptom relief after the procedure.The right ventricular end-diastolic volume index(RVEDVi)measured by CMR 6 months after PPVI showed a significant decrease compared to preprocedural values[(89.99±13.85)ml/m2 vs.(144.93±11.28)ml/m2,P=0.001].Postoperative pulmonary regurgitation were significantly improved or disappeared in all patients,and there was no statistically significant difference in the average peak pressure gradient measured by echocardiogram between preoperative and the latest follow-up[(23.25±8.39)mmHg vs.(18.75±6.28)mmHg,P=0.210].Over an average follow-up period of(9.25±0.71)years,1 case of infective endocarditis occurred 5 years after PPVI.During the follow-up,no death,deterioration of heart failure,malignant arrhythmia or other serious complications were observed.All patients completed 8-year follow-up,and 3 completed 10-year follow-up.All patients were graded as NYHA functional class one at the latest follow-up.Conclusions PPVI using the domestically produced self-expanding Venus P is safe and feasible for the treatment of patients with post-surgical RVOT dysfunction and suitable anatomy.Our study confirms the long-term efficacy and durability of Venus P from multiple perspectives,and no severe stent fracture occurred without pre-stent implantation in the native RVOT.
6.Evolution of indications for percutaneous pulmonary valve implantation
Qian-bei HE ; Yuan FENG ; Zhen-gang ZHAO
Chinese Journal of Interventional Cardiology 2025;33(5):278-283
Patients with congenital heart disease combined with right ventricular outflow tract malformations often leave varying degrees of pulmonary regurgitation and/or obstruction after surgical/interventional correction.With the continuation of time,the significant increasement of the right ventricular volume load will affect patients'quality of life and survival,which may require multiple pulmonary valve replacements.Compared with high-risk surgery,percutaneous pulmonary valve implantation is a less invasive,safer and more effective interventional valve replacement technology,which can improve patients' long-term prognosis.With the progress of technology and the improvement of instruments,the indications of percutaneous pulmonary valve implantation have gradually expanded,and have gradually become an alternative treatment of surgical thoracic valve replacement.Combined with the latest research progress of percutaneous pulmonary valve implantation,this paper discusses the change of indications,optimal timing of intervention and instrument selection in recent years.
7.Effects of different CO2 pneumoperitoneum pressures on overweight or obese patients with laparoscopic panhysterectomy in Trendelenburg position
Hao WANG ; Ke GU ; Li-hua RAO ; Bei HU ; Wei-wei JI ; Zhen TIAN ; Ti-jun DAI
Journal of Regional Anatomy and Operative Surgery 2025;34(2):150-153
Objective To explore the effects of different CO2 pneumoperitoneum pressures during surgery on overweight or obese patients with laparoscopic panhysterectomy in Trendelenburg position.Methods A total of 88 overweight or obese patients who underwent laparoscopic panhysterectomy were selected and randomly divided into the low-pressure group and the high-pressure group according to random number table method,with 44 patients in each group.All patients used CO2 as the pneumoperitoneum medium during surgery,with 10 mmHg of CO2 pneumoperitoneum pressure in the low-pressure group and 15 mmHg of CO2 pneumoperitoneum pressure in the high-pressure group.The operation-related indexes,respiratory indicators,nasopharyngeal temperature and adverse reactions of patients were compared between the two groups.Results There was no significant difference in the surgical time,blood loss,intraoperative infusion volume,incidence of organ injury,and laparotomy rate between the two groups(P>0.05).The recovery time of anesthesia of patients in the low-pressure group was shorter than that in the high-pressure group(P<0.05).At 30 minutes after the establishment of pneumoperitoneum,the peak airway pressure(Ppeak)and plateau pressure(Pplat)of patients in the high-pressure group were significantly higher than those in the low-pressure group(P<0.05),while the dynamic lung compliance(Cdyn)of patients in the high-pressure group was significantly lower than that in the low-pressure group(P<0.05).At 60 minutes after the establishment of pneumoperitoneum and the end of pneumoperitoneum,the nasopharyngeal temperature of patients in the high-pressure group were significantly lower than those in the low-pressure group(P<0.05).The incidences of intraoperative hypothermia and shivering in the high-pressure group were significantly higher than those in the low-pressure group(P<0.05).Conclusion Compared with 15 mmHg of CO2 pneumoperitoneum pressure,10 mmHg of CO2 pneumoperitoneum pressure on overweight or obese patients with laparoscopic panhysterectomy in Trendelenburg position does not increase surgical difficulty,and the patients has lower airway pressure,better lung compliance,fewer adverse reactions,and faster recovery,which can also avoid intraoperative hypothermia.
8.Comparison of the effects of CR and PS prostheses in the treatment of knee osteoarthritis
Shangz-Eng WANG ; Bei ZHANG ; Zhen WANG ; Shang MA ; Deyang RUANGZHANG ; Zhiying YIN ; Yunqi ZHU ; Kunpeng HU ; Shao CHENG
The Journal of Practical Medicine 2024;40(9):1251-1256
Objective To compare the effect of posterior cruciate ligament retaining(CR)and posterior cruciate substituting(PS)prosthesis in knee arthroplasty.Methods 64 patients with knee osteoarthritis were admitted to our department from June 2021 to June 2022 and whom met the selection criteria were randomly selected and divided into observation group and control group(n = 32).CR prosthesis was used in the observation group,and PS prosthesis was used in the control group.Operation time,postoperative drainage volume,difference of hemoglobin(HGB)before and after operation,postoperative hospital stay,postoperative range of motion at 7 d,14 d,45 d,3 months and 1 year were recorded.ROM,visual analog pain Scale(VAS),Hospital for special surgery(HSS)score,and maximum forward and backward displacement of knee joint and the regular radiographs were also recorded,too.Results The two groups were similar in terms of operation time,postoperative hospital stay,postoperative VAS score and maximum anterior and posterior displacement of knee joint,with P values greater than 0.05,which had no statistical significance.The postoperative drainage volume in the observation group was significantly less than that in the control group,with statistical significance(P<0.05).The HGB difference of observation group was significantly lower than that of control group,with statistical significance(P<0.05).There was no statistically significant differ-ence in ROM and HSS scores between the two groups before surgery;the ROM and HSS scores of the control group at 7,14 and 45 days after surgery was better than that of the observation group,with statistical significance(P<0.05);the ROM and HSS scores of the two groups at 3 months after surgery was not statistically significant.The ROM and HSS scores in the observation group was better than that in the control group at 6 months and 1 year after operation,and the difference was statistically significant(P<0.05).Conclusions CR prosthesis is superior to PS prosthesis in terms of intraoperative blood loss and post-operative drainage volume,which can reduce surgical risk.Both kinds of prosthesis can achieve good knee stability after surgery,while PS prosthesis has better early clinical effect,while CR prosthesis has better long-term clinical effect.
9.Imaging characteristics of the affected eye and fellow eye in patients with central serous chorioretinopathy of different ages
Bei XIAO ; Yanping SONG ; Ya YE ; Zhen HUANG ; Ming YAN
International Eye Science 2024;24(6):937-942
AIM: To observe the imaging characteristics of the affected eyes of patients with central serous chorioretinopathy(CSC)of different ages and their asymptomatic fellow eyes.METHODS: Retrospective study. A total of 76 cases(88 eyes)of CSC patients diagnosed in the ophthalmology department of our hospital from April to September, 2023 and 35 cases(35 eyes of asymptomatic fellow eyes of patients with unilateral CSC)were selected for the study. According to age, they were divided into young and middle-aged groups(<40 years old), middle-aged groups(40-50 years old)and middle-aged and elderly groups(>50 years old). The imaging features of the affected eyes of CSC patients of different ages and their asymptomatic fellow eyes were observed.RESULTS: The subfoveal choroidal thickness(SFCT)of CSC eyes in the young and middle-aged patients(487.30±83.33 μm)was significantly greater than that of the middle-aged group(414.17±96.02 μm, P<0.05)and the middle-aged and elderly group(409.4±107.42 μm, P<0.05). The incidence of choroidal neovascularization(CNV)in CSC patients of the middle-aged and elderly group was significantly higher than that in the young and middle-aged group(P<0.0167). The SFCT of the asymptomatic fellow eye of the unilateral CSC patient in the young and middle-aged group(511.29±40.89 μm)was significantly larger than that of the middle-aged and elderly group(364.76±82.26 μm, P<0.05). Among them, the vortex vein anastomosis rate in eyes with CSC is higher than 90%, and vortex vein anastomosis or dilatation is present in all asymptomatic fellow eyes of CSC patients.CONCLUSION: There are differences in the imaging manifestations of CSC-affected eyes and their asymptomatic fellow eyes of different age groups. SFCT is generally thickened and gradually becomes thinner with the growth of age. The incidence of CNV in CSC-affected eyes is the highest in the middle-aged and elderly group. In addition, vortex vein anastomosis and dilatation are common in CSC-affected eyes and asymptomatic fellow eyes.
10.The role of vortex veins in the pathogenesis of central serous chorioretinopathy
Bei XIAO ; Yanping SONG ; Ming YAN ; Ya YE ; Zhen HUANG
Chinese Journal of Ocular Fundus Diseases 2024;40(4):319-323
Central serous chorioretinopathy (CSC) is one of the main causes of impaired visual function in middle-aged men. CSC is characterized by a thickening of the choroid and hyperpermeability of the choroidal vessels, resulting in serous subretinal fluid. The pathogenesis of CSC is not fully understood. Since the introduction of indocyanine green angiography, the detection of the influence of the vortex veins in CSC, it has been established that the presence of a thick choroid may be caused by congestion of the vortex vein, resulting in new choroidal drainage through a vortex vein anastomosis. The study of vortex venous blood hemodynamics has elucidated the new concept of the pathogenesis of CSC, deepened our understanding of the disease, and provided a theoretical basis for new treatment methods. With a better understanding of the pathogenesis of CSC, we expect to be able to stratify patients at risk in the clinic and evaluate optimized treatment options for patients with CSC

Result Analysis
Print
Save
E-mail