1.Status and implications of pharmacist competency assessment tools
Yu TIAN ; Bei DING ; Chenyang ZHANG ; Yi ZHAO ; Jiaying WANG
China Pharmacy 2026;37(5):553-558
OBJECTIVE To systematically review the status on pharmacist competency assessment tools both domestically and internationally, providing a theoretical basis for constructing scientific and applicable pharmacist competency assessment tools in China. METHODS Through literature review and comparative analysis, 15 representative domestic and international pharmacist competency assessment tools were systematically summarized, and their theoretical foundations, core dimensions, methodological characteristics and practical applications were compared and implications were given. RESULTS &CONCLUSIONS International research has established relatively mature evaluation systems. Represented by those developed from the United Kingdom, the United States, and the International Pharmaceutical Federation, these assessment tools demonstrate scientific structure, wide application, and dynamic and international applicability. While domestic research has progressed in sub-specialties such as clinical pharmacists, licensed pharmacists and pediatric pharmacists, it still faces challenges including insufficient standardization, inadequate validation, delayed updates, and limitations in practical application. The reasons for the disparities in assessment tools between China and other countries include differences in pharmaceutical care models, varying pharmacist training systems, cultural and social background factors, as well as differences in industry management and international influence. Based on this, the author suggests promoting the development and research of assessment tools for pharmacist job competency in China from four aspects: mechanism construction, system refinement, standardization development, and practical implementation.
2.Clinical study on the treatment of chronic atrophic gastritis with spleen and stomach weakness syndrome by Piwei Peiyuan Pill combined with moxibustion
Kairui WU ; Yu YE ; Bei PEI ; Biao SONG ; Yi ZHANG ; Tingting LI ; Qi YANG ; Yun LIU ; Xuejun LI
Journal of Beijing University of Traditional Chinese Medicine 2025;48(2):280-290
Objective:
To determine the clinical efficacy and mechanism of Piwei Peiyuan Pill (PPP) combined with moxibustion for treating patients with chronic atrophic gastritis (CAG) with spleen and stomach weakness syndrome.
Methods:
Ninety-six CAG patients with spleen and stomach weakness syndrome who met the inclusion and exclusion criteria were enrolled at the Department of Spleen and Stomach Diseases of the Second Affiliated Hospital of Anhui University of Chinese Medicine from June 2022 to December 2023. The patients were randomly divided into a control, a Chinese medicine, and a combined group using a random number table method, with 32 cases in each group (two cases per group were excluded). The control group was treated with rabeprazole combined with folic acid tablets (both thrice daily), the Chinese medicine group was treated with PPP (8 g, thrice daily), and the combined group was treated with moxa stick moxibustion (once daily) on the basis of the Chinese medicine group for 12 consecutive weeks. Gastric mucosa atrophy in the three groups was observed before and after treatment. The gastric mucosal pathological score was evaluated. The Patient Reported Outcome (PRO) scale was used to evaluate the patients′ physical and mental health status and quality of life.An enzyme-linked immunosorbent assay was used to detect serum tumor necrosis factor (TNF)-α, interleukin (IL)-1β, IL-4, IL-10, IL-37, and transforming growth factor (TGF)-β levels in each group. Real-time fluorescence PCR was used to detect the relative expression levels of signal transducer and activator of transcription 3 (STAT3) and mammalian target of rapamycin (mTOR) mRNA in each group. Western blotting was used to detect the relative expression levels of proteins related to the STAT3/mTOR signaling pathway, and the adverse drug reactions and events were recorded and compared.
Results:
There was no statistical difference in age, gender, disease duration, family history of gastrointestinal tumors, alcohol consumption history, and body mass index among the three groups of patients.The total therapeutic efficacy rates of the control, Chinese medicine, and combined groups in treating gastric mucosal atrophy were 66.67% (20/30), 86.67% (26/30), and 90.00% (27/30), respectively (P<0.05). Compared to before treatment, the pathological and PRO scale scores of gastric mucosa in each group decreased after treatment, and TNF-α, IL-1β, IL-37, and TGF-β levels decreased. The relative STAT3 and mTOR mRNA expression levels, as well as the relative STAT3, p-STAT3, mTOR, and p-mTOR protein expression levels decreased (P<0.05), whereas the IL-4 and IL-10 levels increased (P<0.05). After treatment, compared to the control group, the pathological score of gastric mucosa, PRO scale score, TNF-α, IL-1β, IL-37, TGF-β content, relative STAT3 and mTOR mRNA expression levels, and relative STAT3, p-STAT3, mTOR, and p-mTOR protein expression levels in the Chinese medicine and combined groups after treatment were reduced (P<0.05), whereas the IL-4 and IL-10 levels increased (P<0.05). After treatment, compared to the Chinese medicine group, the combined group showed a decrease in relative STAT3, mTOR mRNA expression levels, and STAT3, p-STAT3, mTOR, and p-mTOR protein expression levels (P<0.05).
Conclusion
The combination of PPP and moxibustion may regulate the inflammatory mechanism of the body by inhibiting the abnormal activation of the STAT3/mTOR signaling pathway, upregulating related anti-inflammatory factor levels, downregulating pro-inflammatory factor expression, and increasing related repair factor expression, thereby promoting the recovery of atrophic gastric mucosa, reducing discomfort symptoms, and improving the physical and mental state of CAG patients with spleen and stomach weakness syndrome.
3.Mechanism of Colquhounia Root Tablets against diabetic kidney disease via RAGE-ROS-PI3K-AKT-NF-κB-NLRP3 signaling axis.
Ming-Zhu XU ; Zhao-Chen MA ; Zi-Qing XIAO ; Shuang-Rong GAO ; Yi-Xin YANG ; Jia-Yun SHEN ; Chu ZHANG ; Feng HUANG ; Jiang-Rui WANG ; Bei-Lei CAI ; Na LIN ; Yan-Qiong ZHANG
China Journal of Chinese Materia Medica 2025;50(7):1830-1840
This study aimed to explore the therapeutic mechanisms of Colquhounia Root Tablets(CRT) in treating diabetic kidney disease(DKD) by integrating biomolecular network mining with animal model verification. By analyzing clinical transcriptomics data, an interaction network was constructed between candidate targets of CRT and DKD-related genes. Based on the topological eigenvalues of network nodes, 101 core network targets of CRT against DKD were identified. These targets were found to be closely related to multiple pathways associated with type 2 diabetes, immune response, and metabolic reprogramming. Given that immune-inflammatory imbalance driven by metabolic reprogramming is one of the key pathogenic mechanisms of DKD, and that many core network targets of CRT are involved in this pathological process, receptor for advanced glycation end products(RAGE)-reactive oxygen species(ROS)-phosphatidylinositol 3-kinase(PI3K)-protein kinase B(AKT)-nuclear factor-κB(NF-κB)-NOD-like receptor family pyrin domain containing 3(NLRP3) signaling axis was selected as a candidate target for in-depth research. Further, a rat model of DKD induced by a high-sugar, high-fat diet and streptozotocin was established to evaluate the pharmacological effects of CRT and verify the expression of related targets. The experimental results showed that CRT could effectively correct metabolic disturbances in DKD, restore immune-inflammatory balance, and improve renal function and its pathological changes by inhibiting the activation of the RAGE-ROS-PI3K-AKT-NF-κB-NLRP3 signaling axis. In conclusion, this study reveals that CRT alleviates the progression of DKD through dual regulation of metabolic reprogramming and immune-inflammatory responses, providing strong experimental evidence for its clinical application in DKD.
Animals
;
Diabetic Nephropathies/metabolism*
;
Receptor for Advanced Glycation End Products/genetics*
;
NF-kappa B/genetics*
;
Signal Transduction/drug effects*
;
Rats
;
NLR Family, Pyrin Domain-Containing 3 Protein/genetics*
;
Proto-Oncogene Proteins c-akt/genetics*
;
Drugs, Chinese Herbal/administration & dosage*
;
Male
;
Phosphatidylinositol 3-Kinases/genetics*
;
Reactive Oxygen Species/metabolism*
;
Humans
;
Plant Roots/chemistry*
;
Rats, Sprague-Dawley
;
Tablets/administration & dosage*
4.VTA is the Key to Pain Resilience in Empathic Behavior.
Xue-Qing WU ; Yi-La DING ; Yu DU ; Zhong CHEN ; Bei TAN
Neuroscience Bulletin 2025;41(2):349-351
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Long-term follow-up of percutaneous pulmonary valve implantation using domestic self-expanding valve-prospective single-center experience
Qian-bei HE ; Qiao LI ; Yi-jian LI ; Rui-tao LI ; Bo-feng CHAI ; Zhi-cheng CHEN ; Zhi-xiang YU ; Zhen-gang ZHAO ; Yuan FENG
Chinese Journal of Interventional Cardiology 2025;33(5):241-248
Objective To explore the long-term efficacy of percutaneous pulmonary valve implantation(PPVI)and the durability of the domestic self-expanding Venus P valve.Methods A total of 8 patients with post-surgical right ventricular outflow tract(RVOT)dysfunction,who were admitted to hospital from October 2014 to July 2016 and deemed anatomically suitable for PPVI with self-expanding valve,were included prospectively.Clinical,imaging,procedural and follow-up data were analyzed.The survival rates,perioperative and long-term complication rates,long-term efficacy of PPVI,and long-term function of Venus P in 8 patients were evaluated.The immediate procedural results were evaluated by clinical implant success rate,which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation<moderate and peak trans-pulmonary pressure gradient<40 mmHg.Results A total of 8 patients were included,with 7 females,aged 14 to 36 years.The initial diagnosis included post-surgical Tetralogy of Fallot(5 cases),post-surgical Trilogy of Fallot(1 case),post-surgical Quadricuspid pulmonary valve stenosis(1 case)and post-surgical Double-Outlet Right Ventricle(1 case).The indications of PPVI included RVOT-pulmonary obstruction and regurgitation(1 case)and isolated regurgitation(7 cases).Clinical implant success was achieved in all of the 8 patients with firmly fixed valve,and there were no such complications as valve detachment,displacement or stent fracture.All patients experienced significant symptom relief after the procedure.The right ventricular end-diastolic volume index(RVEDVi)measured by CMR 6 months after PPVI showed a significant decrease compared to preprocedural values[(89.99±13.85)ml/m2 vs.(144.93±11.28)ml/m2,P=0.001].Postoperative pulmonary regurgitation were significantly improved or disappeared in all patients,and there was no statistically significant difference in the average peak pressure gradient measured by echocardiogram between preoperative and the latest follow-up[(23.25±8.39)mmHg vs.(18.75±6.28)mmHg,P=0.210].Over an average follow-up period of(9.25±0.71)years,1 case of infective endocarditis occurred 5 years after PPVI.During the follow-up,no death,deterioration of heart failure,malignant arrhythmia or other serious complications were observed.All patients completed 8-year follow-up,and 3 completed 10-year follow-up.All patients were graded as NYHA functional class one at the latest follow-up.Conclusions PPVI using the domestically produced self-expanding Venus P is safe and feasible for the treatment of patients with post-surgical RVOT dysfunction and suitable anatomy.Our study confirms the long-term efficacy and durability of Venus P from multiple perspectives,and no severe stent fracture occurred without pre-stent implantation in the native RVOT.


Result Analysis
Print
Save
E-mail