1.Revision and Application of the General Rule for Particle Size Analysis by Light Scattering in the 2025 Edition of the Pharmacopoeia of the People's Republic of China
Hui WU ; Baoxi ZHANG ; Ping ZHENG ; Yongjian YANG ; Qiaoru XUE ; Yihong LU ; Xuefan CHEN ; Langui XIE ; Xia ZHAO
Herald of Medicine 2025;44(11):1773-1778
This article focused on the revision and application of General Rule 0982 Determination of Particle Size and Size Distribution by Light Scattering Method in the Chinese Pharmacopoeia(2025 edition).By referencing domestic and international technical requirements and considering practical applications,the structure and content of this general rule were analyzed,and specific revisions were proposed.Key recommendations included adding sections on method validation and results reporting to the current general rule,incorporating the appendix content into the main text,and revising/supplementing the method name,introduction,instrument requirements,and determination procedures.The revised light scattering method would strengthen China's capacity for pharmaceutical quality control.
2.Revision and Application of the General Rule for Particle Size Analysis by Light Scattering in the 2025 Edition of the Pharmacopoeia of the People's Republic of China
Hui WU ; Baoxi ZHANG ; Ping ZHENG ; Yongjian YANG ; Qiaoru XUE ; Yihong LU ; Xuefan CHEN ; Langui XIE ; Xia ZHAO
Herald of Medicine 2025;44(11):1773-1778
This article focused on the revision and application of General Rule 0982 Determination of Particle Size and Size Distribution by Light Scattering Method in the Chinese Pharmacopoeia(2025 edition).By referencing domestic and international technical requirements and considering practical applications,the structure and content of this general rule were analyzed,and specific revisions were proposed.Key recommendations included adding sections on method validation and results reporting to the current general rule,incorporating the appendix content into the main text,and revising/supplementing the method name,introduction,instrument requirements,and determination procedures.The revised light scattering method would strengthen China's capacity for pharmaceutical quality control.
3.Research Progress of CocrystalTechnology in Chiral Drug Resolution
Yuhan GAO ; Yue TAO ; Hengming GOU ; Baoxi ZHANG ; Li ZHANG ; Shiying YANG ; Yang LYU
Herald of Medicine 2025;44(6):886-893
In recent years,the demand for single enantiomer drugs has gradually increased,and the separation technology of chiral drugs has also been developed rapidly.In this article,we summarized the application and progress of cocrystal technology in chiral drug resolution,focusing on the existence forms of cocrystal former formations(single compound molecules,ions,and claths),the common preparation methods of cocrystal resolution,the physical and chemical factors affecting the resolution efficiency(co-formed chirality,solvent system,temperature)and the computer-aided prediction method of chiral cocrystal in the process of chiral drug resolution,to provide a reference for related research on chiral resolution using cocrystal technology.
4.Therapeutic value of visual endoscopic retrograde appendicitis therapy in children with acute suppurative appendicitis
Anding ZHANG ; Na FAN ; Mingzhong WANG ; Lingchao ZENG ; Chunhui WANG ; Yan LIN ; Jiaren ZHOU ; Yaping SONG ; Nini ZHANG ; Haiyan WANG ; Hongwei GUO ; Ying ZHOU ; Baoxi WANG ; Xun JIANG
Chinese Journal of Pediatrics 2025;63(7):754-758
Objective:To investigate the therapeutic value of visual endoscopic retrograde appendicitis therapy (vERAT) in pediatric patients with acute suppurative appendicitis (ASA).Methods:This was a retrospective cohort study. A total of 55 ASA patients who underwent vERAT at the Pediatric Department of the Tangdu Hospital of Air Force Medical University between November 2023 and January 2025 were selected and divided into groups based on the presence or absence of fecaliths: fecalith group and non-fecalith group. The baseline characteristics, initial treatment success rates, treatment costs, hospital stay duration, procedure time, and recurrence rates between two groups were compared. Mann-Whitney U test and χ2 test were used to evaluate group differences. Results:A total of 55 ASA patients were enrolled, including 38 males and 17 females, with the age of 11.2 (9.2, 13.1) years. Based on the presence of fecaliths, patients were divided into two groups: fecalith group (32 cases) and non-fecalith group (23 cases). No statistically significant differences were observed between the two groups in terms of age, gender, duration of abdominal pain, white blood cell count, neutrophil percentage, diameter of appendix, thickness of appendix clinical symptoms or signs (all P>0.05). The initial treatment success rates were 91% (29/32) in fecalith group and 96% (22/23) in non-fecalith group, with no statistically significant difference ( P=0.632). However, significant differences were noted in stent placement ( χ2=5.85, P=0.026) and procedure time ( Z=4.75, P<0.001). The follow-up duration time was 6.0 (2.0, 12.0) and 7.0 (2.0, 8.5) months for the fecalith and non-fecalith groups, respectively, with no significant difference ( Z=0.05, P=0.962). The recurrence rates were 14% (4/29) in fecalith group and 5% (1/22) in non-fecalith group, with no statistically significant difference ( P=0.375). Conclusions:vERAT can safely and effectively treat pediatric ASA, regardless of the presence or absence of fecaliths. It can provide a new treatment option for ASA.
5.Research Progress of CocrystalTechnology in Chiral Drug Resolution
Yuhan GAO ; Yue TAO ; Hengming GOU ; Baoxi ZHANG ; Li ZHANG ; Shiying YANG ; Yang LYU
Herald of Medicine 2025;44(6):886-893
In recent years,the demand for single enantiomer drugs has gradually increased,and the separation technology of chiral drugs has also been developed rapidly.In this article,we summarized the application and progress of cocrystal technology in chiral drug resolution,focusing on the existence forms of cocrystal former formations(single compound molecules,ions,and claths),the common preparation methods of cocrystal resolution,the physical and chemical factors affecting the resolution efficiency(co-formed chirality,solvent system,temperature)and the computer-aided prediction method of chiral cocrystal in the process of chiral drug resolution,to provide a reference for related research on chiral resolution using cocrystal technology.
6.Therapeutic value of visual endoscopic retrograde appendicitis therapy in children with acute suppurative appendicitis
Anding ZHANG ; Na FAN ; Mingzhong WANG ; Lingchao ZENG ; Chunhui WANG ; Yan LIN ; Jiaren ZHOU ; Yaping SONG ; Nini ZHANG ; Haiyan WANG ; Hongwei GUO ; Ying ZHOU ; Baoxi WANG ; Xun JIANG
Chinese Journal of Pediatrics 2025;63(7):754-758
Objective:To investigate the therapeutic value of visual endoscopic retrograde appendicitis therapy (vERAT) in pediatric patients with acute suppurative appendicitis (ASA).Methods:This was a retrospective cohort study. A total of 55 ASA patients who underwent vERAT at the Pediatric Department of the Tangdu Hospital of Air Force Medical University between November 2023 and January 2025 were selected and divided into groups based on the presence or absence of fecaliths: fecalith group and non-fecalith group. The baseline characteristics, initial treatment success rates, treatment costs, hospital stay duration, procedure time, and recurrence rates between two groups were compared. Mann-Whitney U test and χ2 test were used to evaluate group differences. Results:A total of 55 ASA patients were enrolled, including 38 males and 17 females, with the age of 11.2 (9.2, 13.1) years. Based on the presence of fecaliths, patients were divided into two groups: fecalith group (32 cases) and non-fecalith group (23 cases). No statistically significant differences were observed between the two groups in terms of age, gender, duration of abdominal pain, white blood cell count, neutrophil percentage, diameter of appendix, thickness of appendix clinical symptoms or signs (all P>0.05). The initial treatment success rates were 91% (29/32) in fecalith group and 96% (22/23) in non-fecalith group, with no statistically significant difference ( P=0.632). However, significant differences were noted in stent placement ( χ2=5.85, P=0.026) and procedure time ( Z=4.75, P<0.001). The follow-up duration time was 6.0 (2.0, 12.0) and 7.0 (2.0, 8.5) months for the fecalith and non-fecalith groups, respectively, with no significant difference ( Z=0.05, P=0.962). The recurrence rates were 14% (4/29) in fecalith group and 5% (1/22) in non-fecalith group, with no statistically significant difference ( P=0.375). Conclusions:vERAT can safely and effectively treat pediatric ASA, regardless of the presence or absence of fecaliths. It can provide a new treatment option for ASA.
7.Efficacy of reduction robot system combined with minimally invasive, microenvironmental protection, micro-stress shielding fixator in the treatment of Sanders types II and III calcaneal fractures
Xiaohui HAO ; Yongqing WANG ; Zhanmin XU ; Xinan ZHANG ; Zhihui ZHAO ; Jingtao SUN ; Zhiqiang YANG ; Meiyue LIU ; Weiyong WU ; Baoxi HAO ; Juwen CHEN
Chinese Journal of Trauma 2025;41(5):463-470
Objective:To evaluate the efficacy of reduction robot system combined with minimally invasive, microenvironmental protection, micro-stress shielding fixator (short for "3M fixator") for Sanders types II and III calcaneal fractures.Methods:A retrospective case series study was conducted to analyze the clinical data of 26 patients (26 feet) with calcaneal fractures admitted to Fourth Affiliated Central Hospital of Tianjin Medical University from June 2022 to June 2024, including 21 males and 5 females, aged 27-69 years [(46.5±2.5)years]. Among them, 10 patients had fractures in the left foot and 16 in the right. According to the Sanders classification, the fractures were classified as type II in 16 patients and type III in 10. All the patients were treated with the close reduction with reduction robot system combined with 3M fixator in a minimally invasive procedure. The surgical waiting time, operative duration, and fracture healing time were recorded. The length, width and height of the calcaneus, B?hler′s angle and Gissane′s angle were compared before operation and at 1, 3 months after operation. The visual analogue scale (VAS) and American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score before operation and at 1, 3 months after operation and at the last follow-up were detected. The postoperative complications were recorded.Results:All the patients were followed up for 6-12 months [(9.7±1.1)months]. The surgical waiting time was 1-4 days [(2.0±0.8)days]. The operative duration was 36-66 minutes [(53.2±9.5)minutes]. All the fractures achieved primary union with a healing period of 3-4 months [(3.2±0.4)months]. At 1, 3 months after operation, the length of the calcaneus [(83.3±3.7)mm and (83.6±3.6)mm], width of the calcaneus [(44.3±5.8)mm and (44.3±5.7)mm], height of the calcaneus [(50.1±3.8)mm and (50.3±3.6)mm], B?hler′s angle [(29.8±2.9)° and (29.8±3.0)°], and Gissane angle [(121.1±6.7)° and (123.9±5.9)°] were significantly improved compared with those before operation [(79.3±4.5)mm, (53.6±4.1)mm, (46.2±3.7)mm, (18.9±3.8)°, (109.0±7.5)°, respectively] ( P<0.05), with no significant differences between those indicators at 1, 3 months after operation ( P>0.05). The VAS scores were (3.2±0.6)points, (1.9±0.5)points, and (1.6±0.3)points at 1, 3 months after operation and at the last follow-up, which were lower than (7.1±0.5)points preoperatively and decreased with the prolongation of follow-up time ( P<0.05). The AOFAS scores were (73.5±6.9)points, (90.1±4.3)points, and (92.0±3.6)points, which were higher than (32.0±4.6)points preoperatively and increased with the follow-up time ( P<0.05). One patient had lateral calcaneal pain after operation, and was alleviated after rehabilitation. No complications such as infection or nonunion were found after operation. Conclusion:The reduction robot system combined with 3M fixator for Sanders types II and III calcaneal fractures demonstrates significant clinical advantages, such as reduced surgical waiting time and operative duration, promoted fracture healing, early alleviated pain, enhanced ankle joint functional recovery, and decreased complication occurrence.
8.Efficacy of reduction robot system combined with minimally invasive, microenvironmental protection, micro-stress shielding fixator in the treatment of Sanders types II and III calcaneal fractures
Xiaohui HAO ; Yongqing WANG ; Zhanmin XU ; Xinan ZHANG ; Zhihui ZHAO ; Jingtao SUN ; Zhiqiang YANG ; Meiyue LIU ; Weiyong WU ; Baoxi HAO ; Juwen CHEN
Chinese Journal of Trauma 2025;41(5):463-470
Objective:To evaluate the efficacy of reduction robot system combined with minimally invasive, microenvironmental protection, micro-stress shielding fixator (short for "3M fixator") for Sanders types II and III calcaneal fractures.Methods:A retrospective case series study was conducted to analyze the clinical data of 26 patients (26 feet) with calcaneal fractures admitted to Fourth Affiliated Central Hospital of Tianjin Medical University from June 2022 to June 2024, including 21 males and 5 females, aged 27-69 years [(46.5±2.5)years]. Among them, 10 patients had fractures in the left foot and 16 in the right. According to the Sanders classification, the fractures were classified as type II in 16 patients and type III in 10. All the patients were treated with the close reduction with reduction robot system combined with 3M fixator in a minimally invasive procedure. The surgical waiting time, operative duration, and fracture healing time were recorded. The length, width and height of the calcaneus, B?hler′s angle and Gissane′s angle were compared before operation and at 1, 3 months after operation. The visual analogue scale (VAS) and American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score before operation and at 1, 3 months after operation and at the last follow-up were detected. The postoperative complications were recorded.Results:All the patients were followed up for 6-12 months [(9.7±1.1)months]. The surgical waiting time was 1-4 days [(2.0±0.8)days]. The operative duration was 36-66 minutes [(53.2±9.5)minutes]. All the fractures achieved primary union with a healing period of 3-4 months [(3.2±0.4)months]. At 1, 3 months after operation, the length of the calcaneus [(83.3±3.7)mm and (83.6±3.6)mm], width of the calcaneus [(44.3±5.8)mm and (44.3±5.7)mm], height of the calcaneus [(50.1±3.8)mm and (50.3±3.6)mm], B?hler′s angle [(29.8±2.9)° and (29.8±3.0)°], and Gissane angle [(121.1±6.7)° and (123.9±5.9)°] were significantly improved compared with those before operation [(79.3±4.5)mm, (53.6±4.1)mm, (46.2±3.7)mm, (18.9±3.8)°, (109.0±7.5)°, respectively] ( P<0.05), with no significant differences between those indicators at 1, 3 months after operation ( P>0.05). The VAS scores were (3.2±0.6)points, (1.9±0.5)points, and (1.6±0.3)points at 1, 3 months after operation and at the last follow-up, which were lower than (7.1±0.5)points preoperatively and decreased with the prolongation of follow-up time ( P<0.05). The AOFAS scores were (73.5±6.9)points, (90.1±4.3)points, and (92.0±3.6)points, which were higher than (32.0±4.6)points preoperatively and increased with the follow-up time ( P<0.05). One patient had lateral calcaneal pain after operation, and was alleviated after rehabilitation. No complications such as infection or nonunion were found after operation. Conclusion:The reduction robot system combined with 3M fixator for Sanders types II and III calcaneal fractures demonstrates significant clinical advantages, such as reduced surgical waiting time and operative duration, promoted fracture healing, early alleviated pain, enhanced ankle joint functional recovery, and decreased complication occurrence.
9.Rapid Determination of Copper Content in Chinese Medicinal Materials by X-ray Fluorescence Spectrometry
Meiju LIU ; Yao ZOU ; Baoxi ZHANG ; Ying WANG ; Kun HU ; Ningbo GONG ; Yang LYU
Herald of Medicine 2024;43(9):1476-1479
Objective To explore the determination method of copper content in Chinese medicinal materials and to provide a scientific basis for the quality control of Chinese medicinal materials.Methods A method for rapid determination of copper content in different varieties of Chinese medicinal materials by X-ray fluorescence spectrometry was established.Results The content of copper in the linear range of 6-40 μg·g-1 showed good linearity with the response strength,which met the quantitative analysis requirements.Conclusion This method has the advantages of being simple,fast,and highly sensitive,and it can be used for rapid quality control of copper content in Chinese medicinal materials.
10.Application of a self-designed robot reduction system for femoral intertrochanteric fractures
Xiaohui HAO ; Zhanmin XU ; Yongqing WANG ; Xinan ZHANG ; Jingtao SUN ; Zhihui ZHAO ; Zhiqiang YANG ; Meiyue LIU ; Weiyong WU ; Baoxi HAO ; Juwen CHEN
Chinese Journal of Orthopaedic Trauma 2024;26(2):103-110
Objective:To explore the clinical effectiveness of a self-designed robot reduction system for femoral intertrochanteric fractures.Methods:A retrospective study was conducted to analyze the 57 patients with intertrochanteric fracture who had been treated at Department of Orthopedics, The Fourth Affiliated Central Hospital of Tianjin Medical University from June 2022 to February 2023. The patients were divided into a robot group (using the self-designed robot reduction system to assist intramedullary nailing) and a traction bed group (using a traction bed to assist intramedullary nailing) based on their fracture reduction method. The robot group: 31 patients, 11 males and 20 females, with an age of (78.7±9.3) years; 16 left and 15 right sides; 17 cases of type 31-A1, 12 cases of type 31-A2 and 2 cases of type 31-A3 by the AO/OTA classification. The traction bed group: 26 patients, 12 males and 14 females, with an age of (78.7±7.7) years; 13 left and 13 right sides; 16 cases of type 31-A1, 9 cases of type 31-A2 and 1 cases of type 31-A3 by the AO/OTA classification. The 2 groups were compared in terms of reduction and operation time, intraoperative blood loss, fluoroscopy frequency, reduction quality, and VAS and Harris score at preoperation, 1 week and 6 months postoperation.Results:The 2 groups were comparable due to insignificant differences in their preoperative general data ( P>0.05). The robot group was significantly better than the traction bed group in reduction time [(4.4±2.2) min versus (9.4±3.2) min], operation time [(29.0±13.5) min versus (49.3±13.3) min], intraoperative blood loss [(76.5±30.5) mL versus (115.0±38.4) mL], fluoroscopy frequency [(10.2±2.6) times versus (14.8±3.2) times], and good/excellent rate of reduction [80.6% (25/31) versus 50.0% (13/26)] ( P<0.05). All patients were followed up for (6.8±0.3) months. Respectively, the VAS scores at preoperation and 6 months postoperation was (6.2±1.3) and (2.4±0.8) points for the robot group, and (6.3±1.3) and (2.7±0.8) points for the traction bed group, showing no statistically significant differences between the 2 groups ( P>0.05). However, the VAS score was (3.3±1.2) points for the robotic group and (4.8±1.5) points for the traction bed group at 1 week postoperation, showing a statistically significant difference between the 2 groups ( P<0.001). Respectively, the Harris scores at preoperation and 6 months postoperation were (35.3±3.0) and (88.7±3.4) points for the robot group, and (35.6±2.9) and (87.2±3.5) points for the traction bed group, showing no statistically significant differences between the 2 groups ( P>0.05). However, the Harris score was (57.3±3.7) points for the robotic group and (46.7±2.8) points for the traction bed group at 1 week postoperation, showing a statistically significant difference between the 2 groups ( P<0.05). The patient satisfaction rates in the robot and traction bed groups were 96.8% (30/31) and 92.3% (24/26), respectively, showing no statistically significant difference ( P>0.05). Conclusion:Our self-designed robot reduction for femoral intertrochanteric fractures can effectively shorten reduction and operation time, reduce bleeding and fluoroscopy frequency, and enhance anatomical reduction.

Result Analysis
Print
Save
E-mail