1.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
2.Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury (version 2025)
Aijun XU ; Shuixia LI ; Bo CHEN ; Mengyuan YE ; Lejiao LANG ; Ning NING ; Lin ZHANG ; Changqing LIU ; Zhonglan CHEN ; Weihu MA ; Weishi LI ; Xiaoning WANG ; Dongmei BIAN ; Jiancheng ZENG ; Xin WANG ; Yuan GAO ; Yaping CHEN ; Jiali CHEN ; Yun HAN ; Xiuting LI ; Yang ZHOU ; Xiaojing SU ; Qiong ZHANG ; Tianwen HUANG ; Ping ZHANG ; Hua LIN ; Xingling XIAO ; Ruifeng XU ; Fanghui DONG ; Bing HAN ; Luo FAN ; Yanling PEI ; Suyun LI ; Xiaoju TAN ; Rongchen GUO ; Yefang ZOU ; Xiaoyun HAN ; Junqin DING ; Yi WANG ; Shuhua DENG ; Jinli GUO ; Yinhua LIANG ; Yuan CEN ; Xiaoqin LIU ; Junru CHEN ; Haiyang YU ; Lunlan LI ; Ying REN ; Yunxia LI ; Jianli LU ; Ying YING ; Lan WEI ; Yin WANG ; Qinhong XU ; Yanqin ZHANG ; Yang LYU ; Shijun ZHANG ; Sui WENJIE ; Sanlian HU ; Shuhong YANG ; Guoqing LI ; Jingjing AN ; Baorong HE ; Leling FENG
Chinese Journal of Trauma 2025;41(6):530-541
Paraplegia caused by spinal cord injury is a serious neurological complication, for which surgery is currently the main treatment method. Due to different surgical approaches, patients are usually expected to maintain a passive prone position for a long time or switch between the supine and prone positions. Affected by multiple factors such as neurogenic sensory disorders, pathological changes in muscle tone and operative duration, the risk of intraoperative acquired pressure injury (IAPI) is significantly increased. Current clinical prevention strategies for IAPI in these patients predominantly focus on localized pressure relief during positioning, lacking systematic, standardized comprehensive prevention protocols or evidence-based guidelines. To address it, Department of Nursing, Orthopedics Branch, China International Exchange and Promotive Association for Medical and Health Care, Spinal Trauma Professional Committee, Orthopedics Branch, Chinese Medical Doctor Association, Nursing Group of Spine and Spinal Cord Professional Committee of Chinese Association of Rehabilitation Medicine organized experts in relevant fields to formulate Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury ( version 2025), based on evidence-based medical evidence and latest research results and clinical practice at home and abroad. Eleven recommendations were put forward from the aspects of preoperative risk assessment, intraoperative prevention strategies, postoperative handover and monitoring, and supportive mechanisms for IAPI prevention, aiming to standardize the prevention measures and management strategies of IAPI in paraplegic patients with spinal cord injury and accelerate the recovery of patients and improve the therapeutic effect.
3.Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures (version 2025)
Yong YANG ; Xiaoguang ZHOU ; Qixin CHEN ; Jian CHEN ; Jian DONG ; Liangjie DU ; Shunwu FAN ; Jin FAN ; Zhong FANG ; Haoyu FENG ; Shiqing FENG ; Haishan GUAN ; Aiguo GAO ; Yanzheng GAO ; Yong HAI ; Da HE ; Dengwei HE ; Haiyi HE ; Dianming JIANG ; Xuewen KANG ; Bin LIN ; Baoge LIU ; Changqing LI ; Fang LI ; Li LI ; Fangcai LI ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Xinyu LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Fei LUO ; Yuhai MA ; Keya MAO ; Xuexiao MA ; Bin MENG ; Xu NING ; Limin RONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Dasheng TIAN ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Qingde WANG ; Qinghe WANG ; Lan WEI ; Jigong WU ; Baoshan XU ; Youjia XU ; Guoyong YIN ; Jinglong YAN ; Feng YAN ; Cao YANG ; Huilin YANG ; Qiang YANG ; Bin ZHAO ; Jie ZHAO ; Yue ZHU ; Jianguo ZHANG ; Wenzhi ZHANG ; Zhongmin ZHANG ; Zhaomin ZHENG ; Yan ZENG ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(7):613-626
Vertebral refracture following percutaneous vertebral augmentation (PVA) is commonly seen in elderly patients with osteoporotic thoracolumbar compression fractures (OTLCF). It can lead to recurrent pain, loss of vertebral height, progression of kyphosis, and even neurological dysfunction, significantly impairing patients′ quality of life. Current diagnosis and treatment face multiple challenges, including high misdiagnosis rate, difficulty in choosing between surgical and non-surgical treatment options, lack of standardized surgical protocols, interference from intralesional bone cement during procedures, inadequate stability of internal fixation in osteoporotic bone, and suboptimal compliance of anti-osteoporotic therapy. Establishing a standardized diagnostic and therapeutic framework is urgently needed. To standardize the management process and improve outcomes for vertebral refractures after PVA in elderly OTLCF patients, Spinal Trauma Group of the Orthopedic Branch of Chinese Medical Doctor Association organized experts in the field to develop Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures ( version 2025), based on current literature and clinical experience, and adhering to principles of scientific rigor and clinical applicability. A total of 11 recommendations were proposed, encompassing diagnosis, treatment, and rehabilitation of vertebral refracture after PVA in elderly patients with OTLCF, aiming to provide a foundation for a standardized management.
4.Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults (version 2025)
Zhengwei XU ; Liming CHENG ; Qixin CHEN ; Jian DONG ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Weimin JIANG ; Dianming JIANG ; Yong HAI ; Lijun HE ; Yuan HE ; Bo LI ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Yong LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Wei MEI ; Chao MA ; Renfu QUAN ; Limin RONG ; Jiacan SU ; Honghui SUN ; Yuemin SONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Liang YAN ; Guoyong YIN ; Jie ZHAO ; Yue ZHU ; Xiaobo ZHANG ; Xuesong ZHANG ; Zhongmin ZHANG ; Rongqiang ZHANG ; Dingjun HAO ; Yanzheng GAO ; Baorong HE
Chinese Journal of Trauma 2025;41(1):19-32
Thoracolumbar spine fracture often leads to severe pain, functional impairments, and neurological deficits, for which open reduction and internal fixation can effectively restore the spinal structural stability. Open decompression and reduction with internal fixation can help relieve spinal cord compression and improve spinal function in cases of concomitant cord injury. Although spinal stability can be restored through surgery, patients often face chronic pain and functional impairments postoperatively. A postoperative rehabilitation program is critical in optimizing therapeutic outcomes, reducing complications, and minimizing the risk of secondary injuries. However, current rehabilitation methods, such as physical therapy, functional training, and pain management, are confronted with problems in clinical practice, including significant variation in efficacy, poor patient adherence, and prolonged rehabilitation period. There is an urgent need for a unified rehabilitation strategy to address these problems. To this end, the Spinal Trauma Group of the Orthopedic Physicians Branch of the Chinese Medical Association and the Spine Health Professional Committee of the Chinese Human Health Technology Promotion Association organized experts from relevant fields to formulate Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults ( version 2025) by integrating evidences from clinical researches and advanced rehabilitation concepts at home and abroad. A total number of 14 recommendations concerning the rehabilitation treatment with multimodal analgesia, psychological intervention, deep vein thrombosis prevention, core muscle and extremity exercise, appropriate use of braces, early weight-bearing, device-aided rehabilitation exercise, neuroregulatory therapy, rehabilitation team were put forward, aiming to standardize the post-operative rehabilitation process following internal fixation, promote the functional recovery, and enhance patients′ quality of life.
5.Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures (version 2025)
Bolong ZHENG ; Wei MEI ; Yanzheng GAO ; Liming CHENG ; Jian CHEN ; Qixin CHEN ; Liang CHEN ; Xigao CHENG ; Jian DONG ; Jin FAN ; Shunwu FAN ; Xiangqian FANG ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Yong HAI ; Baorong HE ; Lijun HE ; Yuan HE ; Hua HUI ; Weimin JIANG ; Junjie JIANG ; Dianming JIANG ; Xuewen KANG ; Hua GUO ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Chao MA ; Xuexiao MA ; Renfu QUAN ; Limin RONG ; Honghui SUN ; Tiansheng SUN ; Yueming SONG ; Hongxun SANG ; Jun SHU ; Jiacan SU ; Jiwei TIAN ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Zhengwei XU ; Huilin YANG ; Jiancheng YANG ; Liang YAN ; Feng YAN ; Guoyong YIN ; Xuesong ZHANG ; Zhongmin ZHANG ; Jie ZHAO ; Yuhong ZENG ; Yue ZHU ; Rongqiang ZHANG
Chinese Journal of Trauma 2025;41(9):805-818
Acute symptomatic osteoporotic thoracolumbar compression fracture (ASOTLF) can lead to chronic low back pain, kyphosis deformity, pulmonary dysfunction, loss of mobility, and even life-threatening complications. Vertebral augmentation is currently the mainstream treatment method for this condition. In 2019, the Editorial Board of Chinese Journal of Trauma and the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association collaboratively led the development of Clinical guideline for vertebral augmentation for acute symptomatic osteoporotic thoracolumbar compression fractures. Six years later, with advances in clinical diagnosis and treatment techniques as well as accumulating evidence in related fields, the 2019 guideline requires updating. To this end, the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association, the Spinal Health Professional Committee of China Human Health Science and Technology Promotion Association, and the Minimally Invasive Orthopedics Professional Committee of Shaanxi Medical Doctor Association have organized experts in the field to develop the Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures ( version 2025) , based on the latest evidence-based medical researches. This guideline incorporates 3 recommendations retained from the 2019 version with updated strength of evidence, along with 12 new recommendations. It provides recommendations from six aspects of diagnosis, pain management, treatment option selection, prevention of postoperative complications, anti-osteoporosis therapy, and postoperative rehabilitation, aiming to provide a reference for standard treatment of vertebral augmentation for ASOTLF in hospitals at all levels.
6.Safety of teriflunomide in Chinese adult patients with relapsing multiple sclerosis: A phase IV, 24-week multicenter study.
Chao QUAN ; Hongyu ZHOU ; Huan YANG ; Zheng JIAO ; Meini ZHANG ; Baorong ZHANG ; Guojun TAN ; Bitao BU ; Tao JIN ; Chunyang LI ; Qun XUE ; Huiqing DONG ; Fudong SHI ; Xinyue QIN ; Xinghu ZHANG ; Feng GAO ; Hua ZHANG ; Jiawei WANG ; Xueqiang HU ; Yueting CHEN ; Jue LIU ; Wei QIU
Chinese Medical Journal 2025;138(4):452-458
BACKGROUND:
Disease-modifying therapies have been approved for the treatment of relapsing multiple sclerosis (RMS). The present study aims to examine the safety of teriflunomide in Chinese patients with RMS.
METHODS:
This non-randomized, multi-center, 24-week, prospective study enrolled RMS patients with variant (c.421C>A) or wild type ABCG2 who received once-daily oral teriflunomide 14 mg. The primary endpoint was the relationship between ABCG2 polymorphisms and teriflunomide exposure over 24 weeks. Safety was assessed over the 24-week treatment with teriflunomide.
RESULTS:
Eighty-two patients were assigned to variant ( n = 42) and wild type groups ( n = 40), respectively. Geometric mean and geometric standard deviation (SD) of pre-dose concentration (variant, 54.9 [38.0] μg/mL; wild type, 49.1 [32.0] μg/mL) and area under plasma concentration-time curve over a dosing interval (AUC tau ) (variant, 1731.3 [769.0] μg∙h/mL; wild type, 1564.5 [1053.0] μg∙h/mL) values at steady state were approximately similar between the two groups. Safety profile was similar and well tolerated across variant and wild type groups in terms of rates of treatment emergent adverse events (TEAE), treatment-related TEAE, grade ≥3 TEAE, and serious adverse events (AEs). No new specific safety concerns or deaths were reported in the study.
CONCLUSION:
ABCG2 polymorphisms did not affect the steady-state exposure of teriflunomide, suggesting a similar efficacy and safety profile between variant and wild type RMS patients.
REGISTRATION
NCT04410965, https://clinicaltrials.gov .
Humans
;
Crotonates/adverse effects*
;
Toluidines/adverse effects*
;
Nitriles
;
Hydroxybutyrates
;
Female
;
Male
;
Adult
;
ATP Binding Cassette Transporter, Subfamily G, Member 2/genetics*
;
Middle Aged
;
Multiple Sclerosis, Relapsing-Remitting/genetics*
;
Prospective Studies
;
Young Adult
;
Neoplasm Proteins/genetics*
;
East Asian People
7.Efficacy of balloon stent or oral estrogen for adhesion prevention in septate uterus: A randomized clinical trial.
Shan DENG ; Zichen ZHAO ; Limin FENG ; Xiaowu HUANG ; Sumin WANG ; Xiang XUE ; Lei YAN ; Baorong MA ; Lijuan HAO ; Xueying LI ; Lihua YANG ; Mingyu SI ; Heping ZHANG ; Zi-Jiang CHEN ; Lan ZHU
Chinese Medical Journal 2025;138(8):985-987
8.Application of Cystatin C International Primary and National Secondary Reference Materials in Dissemination of Quantity Value for Seven Routine Detection Reagent Systems in Clinical Laboratories
Jiangman SUN ; Min LI ; Xiangzhao MENG ; Hongyuan YU ; Baorong CHEN ; Yan SHAO
Journal of Modern Laboratory Medicine 2025;40(5):189-193
Objective To evaluate the application of Cystatin C(Cys C)international primary reference material and national secondary reference materials for quantity transfer in seven conventional systems.Methods Seven Cys C reagents from different manufacturers commonly used in clinical laboratories were used to simultaneously measure two standard substances[ERM-DA471/IFCC,GBW(E)091173~6]and 42 individual serum samples.The theoretical and measured values of the standard substances were linearly fitted,and the measured values of the single serum samples were substituted into the fitting equation to obtain the calibrated values,and the measured values and calibrated values were compared with CLSI EP9-A3 file.Results The theoretical and measured values of ERM-DA471/IFCC and GBW(E)091173~6 were linearly fitted,and the regression equations were Y=0.941X+0.159,Y=0.963X+0.162,respectively,with correlation coefficients of 1.000(taking system B as an example).All system analysis models were analyzed using Passing-Bablok regression analysis.The comparison bias between the calibration values and measurement values of two standards in seven systems were-20.38%~10.58%and-16.76%~9.90%,respectively,with the same bias trend.The comparison bias of the calibrated values of the two standard substances was-4.18%~2.31%.The calibration of the standards had a significant improvement for the bias between calibration value and measurement value exceeding±4%.The bias of the measured values in the pairwise combinations of each system at each medical decision level was-17.87%~14.97%and the bias range of GBW(E)091173~6 calibration values at each medical decision level was-4.96%~4.51%,with most values being less than 3%.The bias of ERM-DA471/IFCC calibration values was-3.92%~6.30%,with most values being less than 4%.Among them,the most common situation was that the bias of ERM-DA471/IFCC calibration value was less than that of measurement value,and the bias of GBW(E)091173~6 calibration value was less than that of ERM-DA471/IFCC calibration value,with 51.19%(43/84)of the comparison bias bata at the level of medical decisionmaking.Conclusion Both reference materials can improve the alignment bias of conventional system,and GBW(E)091173~6 calibration effect is better than ERM-DA471/IFCC.
9.Application of Cystatin C International Primary and National Secondary Reference Materials in Dissemination of Quantity Value for Seven Routine Detection Reagent Systems in Clinical Laboratories
Jiangman SUN ; Min LI ; Xiangzhao MENG ; Hongyuan YU ; Baorong CHEN ; Yan SHAO
Journal of Modern Laboratory Medicine 2025;40(5):189-193
Objective To evaluate the application of Cystatin C(Cys C)international primary reference material and national secondary reference materials for quantity transfer in seven conventional systems.Methods Seven Cys C reagents from different manufacturers commonly used in clinical laboratories were used to simultaneously measure two standard substances[ERM-DA471/IFCC,GBW(E)091173~6]and 42 individual serum samples.The theoretical and measured values of the standard substances were linearly fitted,and the measured values of the single serum samples were substituted into the fitting equation to obtain the calibrated values,and the measured values and calibrated values were compared with CLSI EP9-A3 file.Results The theoretical and measured values of ERM-DA471/IFCC and GBW(E)091173~6 were linearly fitted,and the regression equations were Y=0.941X+0.159,Y=0.963X+0.162,respectively,with correlation coefficients of 1.000(taking system B as an example).All system analysis models were analyzed using Passing-Bablok regression analysis.The comparison bias between the calibration values and measurement values of two standards in seven systems were-20.38%~10.58%and-16.76%~9.90%,respectively,with the same bias trend.The comparison bias of the calibrated values of the two standard substances was-4.18%~2.31%.The calibration of the standards had a significant improvement for the bias between calibration value and measurement value exceeding±4%.The bias of the measured values in the pairwise combinations of each system at each medical decision level was-17.87%~14.97%and the bias range of GBW(E)091173~6 calibration values at each medical decision level was-4.96%~4.51%,with most values being less than 3%.The bias of ERM-DA471/IFCC calibration values was-3.92%~6.30%,with most values being less than 4%.Among them,the most common situation was that the bias of ERM-DA471/IFCC calibration value was less than that of measurement value,and the bias of GBW(E)091173~6 calibration value was less than that of ERM-DA471/IFCC calibration value,with 51.19%(43/84)of the comparison bias bata at the level of medical decisionmaking.Conclusion Both reference materials can improve the alignment bias of conventional system,and GBW(E)091173~6 calibration effect is better than ERM-DA471/IFCC.
10.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.

Result Analysis
Print
Save
E-mail