1.High-efficient discovering the potent anti-Notum agents from herbal medicines for combating glucocorticoid-induced osteoporosis.
Yuqing SONG ; Feng ZHANG ; Jia GUO ; Yufan FAN ; Hairong ZENG ; Mengru SUN ; Jun QIAN ; Shenglan QI ; Zihan CHEN ; Xudong JIN ; Yunqing SONG ; Tian TIAN ; Zhi QIAN ; Yao SUN ; Zhenhao TIAN ; Baoqing YU ; Guangbo GE
Acta Pharmaceutica Sinica B 2025;15(8):4174-4192
Notum, a negative feedback regulator of the Wnt signaling, has emerged as a promising target for treating glucocorticoid-induced osteoporosis (GIOP). This study showcases an efficient strategy for discovering the anti-Notum constituents from herbal medicines (HMs) as novel anti-GIOP agents. Firstly, a rapid-responding near-infrared fluorogenic substrate for Notum was rationally engineered for high-throughput identifying the anti-Notum HMs. The results showed that Bu-Gu-Zhi (BGZ), a known anti-osteoporosis herb, potently inhibited Notum in a competitive-inhibition manner. To uncover the key anti-Notum constituents in BGZ, an efficient strategy was adapted via integrating biochemical, phytochemical, computational, and pharmacological assays. Among all identified BGZ constituents, three furanocoumarins were validated as strong Notum inhibitors, while 5-methoxypsoralen (5-MP) showed the most potent anti-Notum activity and favorable safety profiles. Mechanistically, 5-MP acted as a competitive inhibitor of Notum via creating strong hydrophobic interactions with Trp128 and Phe268 in the catalytic cavity of Notum. Cellular assays showed that 5-MP remarkably promoted osteoblast differentiation and activated Wnt signaling in dexamethasone (DXMS)-challenged MC3T3-E1 osteoblasts. In dexamethasone-induced osteoporotic mice, 5-MP strongly elevated bone mineral density (BMD) and improved cancellous and cortical bone thickness. Collectively, this study constructs a high-efficient platform for discovering key anti-Notum constituents from HMs, while 5-MP emerges as a promising anti-GIOP agent.
2.Modified and traditional iliolumbar pedicle screw-rod system for the fixation of vertically unstable posterior pelvic ring dislocation: a biomechanical comparative study
Jun ZHANG ; Guoding LI ; Jian WANG ; Baoqing YU
Chinese Journal of Trauma 2024;40(2):146-153
Objective:To compare the biomechanical properties of the modified and traditional iliolumbar pedicle screw-rod system for the fixation of vertically unstable posterior pelvic ring dislocation.Methods:The CT images of the lumbar spine, pelvis, and femur from a 31-year-old healthy male volunteer were used to establish models of posterior pelvic ring dislocation and unilateral and bilateral fixation models of modified and traditional iliolumbar pedicle screw-rod systems with the three-dimensional virtual software using the finite element method. By restraining the distal ends of the femurs of both sides and applying a vertical load of 500 N to the L 1 vertebral body, the maximum stress of the intact pelvis model and the stiffness of the posterior pelvic ring dislocation model were evaluated to validate the reliability of the models. After the validation of the models, a follower load of 400 N was applied in the direction of the L 1 vertebral curve to simulate the upper body weight; the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum of the modified and traditional iliolumbar pedicle screw-rod system models were compared. Additionally, stress distributions of the implant and the pelvis were also compared. Results:(1) The maximum stress of the intact pelvis model was 22.0 MPa, with the stiffness of the posterior pelvic ring dislocation model as 180.03 N/mm. (2) In terms of the maximum vertical displacement of the sacrum, the bilateral modified iliolumbar pedicle screw-rod system was similar to the bilateral traditional iliolumbar pedicle screw-rod system. However, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the bilateral modified iliolumbar pedicle screw-rod system were 0.57 mm, 0.19 mm and 0.68 mm respectively, which were markedly smaller than those of the bilateral traditional iliolumbar pedicle screw-rod system (1.38 mm, 0.26 mm and 1.41 mm respectively). (3) The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the unilateral modified iliolumbar pedicle screw-rod system were 0.70 mm, 0.73 mm, 0.17 mm and 0.88 mm respectively, which were markedly smaller than those of the unilateral traditional iliolumbar pedicle screw-rod system (1.17 mm, 2.21 mm, 0.31 mm and 2.29 mm respectively). (4) The stress of the implant was concentrated on the connecting rod between the iliac pedicle screw-rod and the lumbar pedicle screw-rod in the modified iliolumbar pedicle screw-rod system, but it was mainly concentrated on the connecting rod at the upper edge of the iliac screw in the traditional iliolumbar pedicle screw-rod system. The maximum stress of the implant was 340.84 MPa in the bilateral modified iliolumbar pedicle screw-rod system, which was 30.4% less than that in the bilateral traditional iliolumbar pedicle screw-rod system (489.77 MPa), and was 351.23 MPa in the unilateral modified iliolumbar pedicle screw-rod system, which was 15.5% less than that in the unilateral traditional iliolumbar pedicle screw-rod system (415.82 MPa). (5) In both modified and traditional iliolumbar pedicle screw-rod systems, the stress of the pelvis was concentrated on the contact area between the iliac screw and the cortical bone. The maximum stress of the pelvis was 19.21 MPa in the bilateral modified iliolumbar pedicle screw-rod system, which was 78.1% less than that in the bilateral traditional iliolumbar pedicle screw-rod system (87.59 MPa), and was 39.91 MPa in the unilateral modified iliolumbar pedicle screw-rod system, which was 70.4% less than that in the unilateral traditional iliolumbar pedicle screw-rod system (134.98 MPa).Conclusion:Compared with the traditional iliolumbar pedicle screw-rod system, the modified iliolumbar pedicle screw-rod system can effectively reduce the displacements of all directions in vertically unstable posterior pelvic ring dislocation and significantly reduce the stress of the implant and the pelvis, thus having good biomechanical stability.
3.Construction and implementation of a bed resource allocation management model based on lean man-agement principles
Dan HU ; Yongmei JIN ; Shuangshuang LI ; Hanchen NI ; Lingli XU ; Zhu JIN ; Baoqing YU
Modern Hospital 2024;24(10):1557-1559
Objective To construct a rational and efficient bed resource allocation management model to reduce pre-hos-pital waiting times,ensure patient safety,and improve satisfaction.Methods Based on lean management principles,a bed re-source allocation management model was developed and continuously optimized.The study compared bed turnover rates and effi-ciency indices,as well as preoperative waiting times for surgical patients,average length of stay,patient satisfaction,and anxiety incidence before and after the implementation of the lean model to evaluate its effectiveness.Results After implementing the lean bed resource allocation model,the bed efficiency index increased by 14.29%,and bed turnover rates improved by 3.34%.The average preoperative waiting time for surgical patients decreased by 100%,and the average length of stay reduced by 87.71%.Patient satisfaction increased by 2.4%,while anxiety incidence dropped by 28.1%.Conclusion The implementa-tion of a lean bed resource allocation model can enhance hospital bed efficiency,shorten preoperative waiting times for surgical patients,reduce average length of stay,and improve patient satisfaction.
4.Chinese expert consensus on the diagnosis and treatment of osteoporotic periarticular fracture of the shoulder in the elderly (version 2023)
Yan HU ; Dongliang WANG ; Xiao CHEN ; Zhongmin SHI ; Fengjin ZHOU ; Jianzheng ZHANG ; Yanxi CHEN ; Liehu CAO ; Sicheng WANG ; Jianfei WANG ; Hongliang WANG ; Yong FENG ; Zhimin YING ; Chengdong HU ; Qinglin HAN ; Ming LI ; Xiaotao CHEN ; Zhengrong GU ; Biaotong HUANG ; Liming XIONG ; Yunfei ZHANG ; Zhiwei WANG ; Baoqing YU ; Yong WANG ; Lei ZHANG ; Lei YANG ; Peijian TONG ; Ximing LIU ; Qiang ZHOU ; Feng NIU ; Weiguo YANG ; Wencai ZHANG ; Shijie CHEN ; Jinpeng JIA ; Qiang YANG ; Tao SHEN ; Bin YU ; Peng ZHANG ; Yong ZHANG ; Jun MIAO ; Kuo SUN ; Haodong LIN ; Yinxian YU ; Jinwu WANG ; Kun TAO ; Daqian WAN ; Lei WANG ; Xin MA ; Chengqing YI ; Hongjian LIU ; Kun ZHANG ; Guohui LIU ; Dianying ZHANG ; Zhiyong HOU ; Xisheng WENG ; Yingze ZHANG ; Jiacan SU
Chinese Journal of Trauma 2023;39(4):289-298
Periarticular fracture of the shoulder is a common type of fractures in the elderly. Postoperative adverse events such as internal fixation failure, humeral head ischemic necrosis and upper limb dysfunction occur frequently, which seriously endangers the exercise and health of the elderly. Compared with the fracture with normal bone mass, the osteoporotic periarticular fracture of the shoulder is complicated with slow healing and poor rehabilitation, so the clinical management becomes more difficult. At present, there is no targeted guideline or consensus for this type of fracture in China. In such context, experts from Youth Osteoporosis Group of Chinese Orthopedic Association, Orthopedic Expert Committee of Geriatrics Branch of Chinese Association of Gerontology and Geriatrics, Osteoporosis Group of Youth Committee of Chinese Association of Orthopedic Surgeons and Osteoporosis Committee of Shanghai Association of Chinese Integrative Medicine developed the Chinese expert consensus on the diagnosis and treatment of osteoporotic periarticular fracture of the shoulder in the elderly ( version 2023). Nine recommendations were put forward from the aspects of diagnosis, treatment strategies and rehabilitation of osteoporotic periarticular fracture of the shoulder, hoping to promote the standardized, systematic and personalized diagnosis and treatment concept and improve functional outcomes and quality of life in elderly patients with osteoporotic periarticular fracture of the shoulder.
5.Expert consensus on diagnosis, prevention and treatment of perioperative lower extremity vein thrombosis in orthopedic trauma patients (2022 edition)
Wu ZHOU ; Faqi CAO ; Ruiyin ZENG ; Baoguo JIANG ; Peifu TANG ; Xinbao WU ; Bin YU ; Zhiyong HOU ; Jian LI ; Jiacan SU ; Guodong LIU ; Baoqing YU ; Zhi YUAN ; Jiangdong NI ; Yanxi CHEN ; Dehao FU ; Peijian TONG ; Dongliang WANG ; Dianying ZHANG ; Peng ZHANG ; Yunfei ZHANG ; Feng NIU ; Lei YANG ; Qiang YANG ; Zhongmin SHI ; Qiang ZHOU ; Junwen WANG ; Yong WANG ; Chengjian HE ; Biao CHE ; Meng ZHAO ; Ping XIA ; Liming XIONG ; Liehu CAO ; Xiao CHEN ; Hui LI ; Yun SUN ; Liangcong HU ; Yan HU ; Mengfei LIU ; Bobin MI ; Yuan XIONG ; Hang XUE ; Ze LIN ; Yingze ZHANG ; Yu HU ; Guohui LIU
Chinese Journal of Trauma 2022;38(1):23-31
Lower extremity deep vein thrombosis (DVT) is one of the main complications in patients with traumatic fractures, and for severe patients, the DVT can even affect arterial blood supply, resulting in insufficient limb blood supply. If the thrombus breaks off, pulmonary embolism may occur, with a high mortality. The treatment and rehabilitation strategies of thrombosis in patients with lower extremity fractures have its particularity. DVT in traumatic fractures patients has attracted extensive attention and been largely studied, and the measures for prevention and treatment of DVT are constantly developing. In recent years, a series of thrombosis prevention and treatment guidelines have been updated at home and abroad, but there are still many doubts about the prevention and treatment of DVT in patients with different traumatic fractures. Accordingly, on the basis of summarizing the latest evidence-based medical evidence at home and abroad and the clinical experience of the majority of experts, the authors summarize the clinical treatment and prevention protocols for DVT in patients with traumatic fractures, and make this consensus on the examination and assessment, treatment, prevention and preventive measures for DVT in patients with different fractures so as to provide a practicable approach suitable for China ′s national conditions and improve the prognosis and the life quality of patients.
6.Efficacy of channel screw guided by O-arm navigation for the treatment of type II fragile fracture of pelvis in the elderly
Zhen JIAN ; Tao LYU ; Rongguang AO ; Yongan WANG ; Xinhua JIANG ; Chengqing YI ; Baoqing YU
Chinese Journal of Trauma 2022;38(3):240-246
Objective:To evaluate the clinical efficacy of channel screw guided by O-arm navigation for the treatment of type II fragile fracture of pelvis (FFP) in the elderly.Methods:A retrospective cohort analysis was performed on clinical data of 37 patients with type II FFP admitted to Shanghai Pudong Hospital, Fudan University Pudong Medical Center from September 2019 to April 2021. There were 9 males and 28 females, aged 65-82 years [(71.8±10.1)years]. A total of 15 patients receipt channel screw fixation under O-arm navigation (surgical group) and 22 patients were treated conservatively (non-surgical group). The visual analogue scale (VAS) and Majeed functional score were compared between the two groups at emergency visit and at 1 week, 1 month, 3 months, 6 months after treatment. The accuracy of screw insertion and complications were also recorded during treatment and follow-up.Results:All patients were followed up for 6-18 months [(13.2±5.1)months]. There were no significant differences in the VAS and Majeed functional score between the two groups at emergency visit (all P>0.05). In both groups, lower VAS and higher Majeed functional score were found at 6 month after treatment as compared with those at emergency visit (all P<0.01). The VAS in surgical group was 2(1, 4)points at 1 week after treatment, lower than 4(3, 5)points in non-surgical group ( P<0.01). The VAS in surgical group was 1(1, 2)points at 1 month after treatment, lower than 3(2, 5)points in non-surgical group ( P<0.05). The Majeed functional score in surgical group was (50.2±4.2)points at 1 week after treatment, higher than (40.2±5.6)points in non-surgical group ( P<0.01). The Majeed functional score in surgical group was (73.8±5.2)points at 1 month after treatment, higher than (62.4±5.0)points in non-surgical group ( P<0.01). The two groups had no significant differences in VAS and Majeed functional score at 3 months and 6 months after treatment (all P>0.05). The accuracy of screw insertion in surgical group was 93% (14/15). In surgical group, the complication rate was 13%(2/15), including urinary tract infection in 1 patient and intraoperative screw penetration in 1, with no screw loosening or nerve and vascular injuries. In non-surgical group, the complication rate was 50%(11/22), including urinary tract infection in 5 patients, penetrating pneumonia in 5 and deep vein thrombosis in 1. The complication rate was significantly different between the two groups ( P<0.05). Conclusions:Compared with non-surgical treatment, the channel screw insertion guided by O-arm navigation can achieve precise screw placement, relieve pain early, promote functional recovery, realize accurate insertion of the screw and reduce the complication rate for type II FFP in the elderly.
7.Expert consensus on rehabilitation strategies for traumatic spinal cord injury
Liehu CAO ; Feng NIU ; Wencai ZHANG ; Qiang YANG ; Shijie CHEN ; Guoqing YANG ; Boyu WANG ; Yanxi CHEN ; Guohui LIU ; Dongliang WANG ; Ximing LIU ; Xiaoling TONG ; Guodong LIU ; Hongjian LIU ; Tao LUO ; Zhongmin SHI ; Biaotong HUANG ; Wenming CHEN ; Qining WANG ; Shaojun SONG ; Lili YANG ; Tongsheng LIU ; Dawei HE ; Zhenghong YU ; Jianzheng ZHANG ; Zhiyong HOU ; Zengwu SHAO ; Dianying ZHANG ; Haodong LIN ; Baoqing YU ; Yunfeng CHEN ; Xiaodong ZHU ; Qinglin HANG ; Zhengrong GU ; Xiao CHEN ; Yan HU ; Liming XIONG ; Yunfei ZHANG ; Yong WANG ; Lei ZHANG ; Lei YANG ; Peijian TONG ; Jinpeng JIA ; Peng ZHANG ; Yong ZHANG ; Kuo SUN ; Tao SHEN ; Shiwu DONG ; Jianfei WANG ; Hongliang WANG ; Yong FENG ; Zhimin YING ; Chengdong HU ; Ming LI ; Xiaotao CHEN ; Weiguo YANG ; Xing WU ; Jiaqian ZHOU ; Haidong XU ; Bobin MI ; Yingze ZHANG ; Jiacan SU
Chinese Journal of Trauma 2020;36(5):385-392
TSCI have dyskinesia and sensory disturbance that can cause various life-threaten complications. The patients with traumatic spinal cord injury (TSCI), seriously affecting the quality of life of patients. Based on the epidemiology of TSCI and domestic and foreign literatures as well as expert investigations, this expert consensus reviews the definition, injury classification, rehabilitation assessment, rehabilitation strategies and rehabilitation measures of TSCI so as to provide early standardized rehabilitation treatment methods for TSCI.
8. Expert consensus on elderly patients with hip fracture under epidemic of novel coronavirus pneumonia
Guohui LIU ; Ximing LIU ; Xiaoling TONG ; Dongliang WANG ; Yanxi CHEN ; Liehu CAO ; Guodong LIU ; Jing LIU ; Yan HU ; Biaotong HUANG ; Zhongmin SHI ; Dianying ZHANG ; Zhiyong HOU ; Hongjian LIU ; Peijian TONG ; Shaojun SONG ; Lei YANG ; Yong WANG ; Lei ZHANG ; Tao LUO ; Meitang WANG ; Peng ZHANG ; Yong ZHANG ; Haodong LIN ; Baoqing YU ; Bobin MI ; Yingze ZHANG ; Jiacan SU
Chinese Journal of Trauma 2020;36(2):104-110
With the spread of novel coronavirus pneumonia (NCP) in December 2019, the management and rehabilitation of elderly patients with hip fractures and protection of medical staff face new challenges, and need to be adjusted appropriately under this very circumstances. Hip fractures in the elderly account for more than half of osteoporotic fractures. Expert group formulate this consensus so as to make better decision against this epidemic and protect patients' families and medical staff. This consensus elaborates not only epidemic condition of NCP, but also general principles of medical admission, treatment and protection for both medical staff and patients, in order to provide some reference and promote the standardization of clinical diagnosis and treatment of elderly patients with hip fractures under the condition of NCP.
9. Application of modified David technique to aortic sinus repair in acute type A aortic dissection
Long WU ; Kailun ZHANG ; Xiaofan HUANG ; Xianqing FENG ; Yu SONG ; Baoqing LIU ; Xionggang JIANG ; Nianguo DONG
Chinese Journal of Thoracic and Cardiovascular Surgery 2019;35(12):731-734
Objective:
To summarize the effect of modified David technique on acute type A aortic dissection sinus formation.
Methods:
From March 2018 to September 2018, modified David technique was applied to aortic sinus remodeling in acute A-type aortic dissection in 19 patients, 13 males and 6 females. The age was 45-67(50.42±15.37) years old and the weight was 45-112(60.32±25.18) kg. Single sinus(noncoronary sinus) was repaired in 15 cases, double sinus formation(noncoronary sinus+ right coronary sinus+ coronary artery transplantation) in 2 cases, left sinus Florid sleeve technical treatment plus double sinus formation(noncoronary sinus+ right coronary sinus+ coronary artery transplantation) in 1 case, Single sinus(noncoronary sinus) repaired and aortic vavle replacement in 1 case. Frozen elephant trunk and total arch replacement in 13 cases, hemiarch replacement in 3 cases.
Results:
There were no deaths in this group. The cardiopulmonary bypass time was 176-245(193.27±32.46) minutes, the aortic cross clamp time was 105-187(122.36±18.57)minutes, and the operation time was 6.5-11.0(7.63±1.31) hours. The mechanical ventilation time was 18-122(48.27±34.73)hours, the intensive care unit stay time was 2-10(5.35±2.62) days, and the postoperative hospital stay was 7-22(12.63±3.25)days. There was no delayed sternal closure during operation, and there was no secondary thoracotomy after operation. One patient developed a transient advanced atrioventricular block. Transient neurological dysfunction was observed in 5 patients. All patients were followed up for more than half a year. The color Doppler echocardiography and computed tomography angiograph(CTA)showed no aortic regurgitation or residual dissection.
Conclusion
The application of modified David technique in the remodeling of aortic root sinus in acute type A aortic dissection is an effective technique with relatively simple process, which is worth promoting.
10. Minimally invasive splayed incisions for calcaneal fractures of sanders types Ⅱ and Ⅲ
Jianbo JIA ; Rongguang AO ; Baoqing YU ; Jianhua ZHOU ; Jiawen HE ; Zhen JIAN
Chinese Journal of Orthopaedic Trauma 2019;21(10):874-880
Objective:
To evaluate the minimally invasive splayed incisions in the internal fixation with a conventional calcaneal plate for calcaneal fractures of sanders types Ⅱ and Ⅲ.
Methods:
This prospective study was conducted from May 1st, 2016 to December 1st, 2017 in the 40 patients with calcaneal fracture at Department of Orthopedics, Shanghai Pudong Hospital. Their ages ranged from 23 to 55 years (average, 39.5 years). According to the Sanders classification, 27 fractures were type Ⅱ and 13 type Ⅲ. They were all treated with a conventional calcaneal plate through minimally invasive splayed incisions. The Böhler and Gissane angles, the height, width and length of the affected calcaneus were compared between preoperation, 3 months after operation and the last follow-up; the clinical function of the affected feet was graded using the Maryland foot score; postoperative complications were observed.
Results:
The 40 patients were followed up for an average of 12.5 months (from 11 to 16 months). All the skin incisions healed well with no skin necrosis or wound infection. No injury to the sural nerve occurred. All the fractures healed after an average of 8 weeks (from 7 to 10 weeks). All the patients resumed their routine daily activities and returned to their former work post after an average time of 4.1 months (from 3 to 6 months). At pre-operation, 3 months after operation and the last follow-up, their Böhler angles were respectively 19.2°±6.3°, 30.5°±6.4° and 29.9°±6.5°; their Gissane angles 103.9°±14.8°, 119.3°±5.6° and 119.8°±6.3°; their calcaneal heights (32.5±3.5) mm, (36.8±1.5) mm and (36.5±1.8) mm; their calcaneal widths (36.8±3.4) mm, (33.1±3.8) mm and (33.0±3.2) mm; their lengths (61.4±4.5) mm, (65.5±6.9) mm and (65.5±9.4) mm. In all the patients, the Böhler and Gissane angles and the calcaneal heights and lengths increased significantly while the calcaneal widths decreased significantly at 3 months after operation and the last follow-up (

Result Analysis
Print
Save
E-mail