1.Development and application of one kind of anaerobic bacteria sampling tube with self-generated carbon dioxide
Min FU ; Bohui LI ; Huannan YU ; Baoguang WANG
China Medical Equipment 2025;22(4):161-164
In order to facilitate the collection for anaerobic bacteria in the clinical work,one kind of sampling tube that can automatically generate carbon dioxide(CO2)was developed.According to the chemical reaction principle of acid and base,the calcium carbonate(CaCO3)and dilute hydrochloric acid(HCl)were used as reactant to produce CO2.The color stripe of CO2 concentration,which was synthesized by Nile blue A and phenolphthalein of indicators,was used to collect clinical anaerobic bacteria.The sampling tube adopted quantitative deposition of chemical reagent in each room,and autonomous control for reaction process,which can arbitrarily set CO2 concentration according to the demand of sampling,and can conduct collection in meeting the demands of multiple anaerobic bacteria for different concentrations of CO2.The sampling tube can realize anaerobic state of entire process from sampling to experiment room for anaerobic bacteria,which is benefit to increase accuracy of culturing bacteria.Its design is compact and flexible,which can be directly stored in the ward to provide use for medical staffs at any time.It has a series of advantages include reasonable design,simple operation,flexible use,high safety and non-risk of cross infection.It is suitable to be promoted in the department of laboratory of hospital at all grades.
2.Development and application of a remote monitoring system for blood counting and temperature of banked blood in transfusion department based on 2.4G wireless transmission technique with STM32 single-chip
Shuangtao LI ; Hongjun CHEN ; Baoguang WANG ; Hongyan LYU ; Jing ZHANG ; Bolin YAN
China Medical Equipment 2025;22(4):1-5
Objective:To develop a remote monitoring system for blood counting and temperature of banked blood in the transfusion department based on 2.4G wireless transmission technique with STM32 single-chip,so as to implement remotely dynamic monitoring for counting and temperature of banked blood in transfusion department.Methods:Based on 2.4G wireless transmission technique with STM32 single-chip,the NRF24L01 wireless transceiver was adopted in this design.STM32 single-chip was used as the processor,and QT50 infrared photoelectric sensor was used to sense the counting for stored blood,and LM35DT temperature sensor was used to collect temperature.The display screen adopted high-brightness digital tube of light emitting diode(LED)of Quanhai(QH)series,so as to achieve accurate data transmission and dynamic monitoring for temperature.Results:The measurement for multiple rooms indoors showed that the distance of wireless transmission can reach 45m without delay,and the counting for banked blood was accurate,and the range of controlling temperature was±0.24℃,which controlled precision was higher than that(±1℃)of national standard.It has ultra-high sensitivity for high and low alarm temperature,which buzzer will alarm when the temperature rises to 7℃or falls to 1℃,and the action time was less than 1s.Conclusion:The developed remote monitoring system for blood counting and temperature of banked blood in transfusion department is flexible in use,and it has stable performance,which can timely prevent the occurrence of blood damage,and greatly reduce the workload of transfusion department.It has a broad application prospect.
3.Development and application of one kind of anaerobic bacteria sampling tube with self-generated carbon dioxide
Min FU ; Bohui LI ; Huannan YU ; Baoguang WANG
China Medical Equipment 2025;22(4):161-164
In order to facilitate the collection for anaerobic bacteria in the clinical work,one kind of sampling tube that can automatically generate carbon dioxide(CO2)was developed.According to the chemical reaction principle of acid and base,the calcium carbonate(CaCO3)and dilute hydrochloric acid(HCl)were used as reactant to produce CO2.The color stripe of CO2 concentration,which was synthesized by Nile blue A and phenolphthalein of indicators,was used to collect clinical anaerobic bacteria.The sampling tube adopted quantitative deposition of chemical reagent in each room,and autonomous control for reaction process,which can arbitrarily set CO2 concentration according to the demand of sampling,and can conduct collection in meeting the demands of multiple anaerobic bacteria for different concentrations of CO2.The sampling tube can realize anaerobic state of entire process from sampling to experiment room for anaerobic bacteria,which is benefit to increase accuracy of culturing bacteria.Its design is compact and flexible,which can be directly stored in the ward to provide use for medical staffs at any time.It has a series of advantages include reasonable design,simple operation,flexible use,high safety and non-risk of cross infection.It is suitable to be promoted in the department of laboratory of hospital at all grades.
4.Development and application of a remote monitoring system for blood counting and temperature of banked blood in transfusion department based on 2.4G wireless transmission technique with STM32 single-chip
Shuangtao LI ; Hongjun CHEN ; Baoguang WANG ; Hongyan LYU ; Jing ZHANG ; Bolin YAN
China Medical Equipment 2025;22(4):1-5
Objective:To develop a remote monitoring system for blood counting and temperature of banked blood in the transfusion department based on 2.4G wireless transmission technique with STM32 single-chip,so as to implement remotely dynamic monitoring for counting and temperature of banked blood in transfusion department.Methods:Based on 2.4G wireless transmission technique with STM32 single-chip,the NRF24L01 wireless transceiver was adopted in this design.STM32 single-chip was used as the processor,and QT50 infrared photoelectric sensor was used to sense the counting for stored blood,and LM35DT temperature sensor was used to collect temperature.The display screen adopted high-brightness digital tube of light emitting diode(LED)of Quanhai(QH)series,so as to achieve accurate data transmission and dynamic monitoring for temperature.Results:The measurement for multiple rooms indoors showed that the distance of wireless transmission can reach 45m without delay,and the counting for banked blood was accurate,and the range of controlling temperature was±0.24℃,which controlled precision was higher than that(±1℃)of national standard.It has ultra-high sensitivity for high and low alarm temperature,which buzzer will alarm when the temperature rises to 7℃or falls to 1℃,and the action time was less than 1s.Conclusion:The developed remote monitoring system for blood counting and temperature of banked blood in transfusion department is flexible in use,and it has stable performance,which can timely prevent the occurrence of blood damage,and greatly reduce the workload of transfusion department.It has a broad application prospect.
5.Detection and Diagnostic Value of Serum ACE2,TWEAK and CCL5 Levels in Children with Attention Deficit Hyperactivity Disorder
Lining WANG ; Ya'nan SHI ; Baoguang LI
Journal of Modern Laboratory Medicine 2024;39(5):152-156,167
Objective To investigate the value of serum angiotensin-converting enzyme 2(ACE2),tumor necrosis factor-like weak inducer of apoptosis(TWEAK)and CC motif chemokine ligand 5(CCL5)levels in the diagnosis and severity assessment of attention deficit hyperactivity disorder(ADHD)in children.Methods From October 2022 to October 2023,125 children with ADHD in Hebei Children's Hospital were selected as ADHD group,and 105 healthy children in Hebei Maternal and Child Health Center were selected as control group.According to the Clinical Global Impressions-Severity(CGI-S),the children were separated into a mild to moderate group(n=83)and a severe group(n=42).ELISA was applied to detect levels of ACE2,TWEAK,CCL5,luteinizing hormone(LH),and prolactin(PRL).The combined raven test(CRT)and conners parental symptom questionnaire(PSQ)were applied to score the cognitive and behavioral status of children with disabilities.Spearman correlation was used to analyze the correlation among serum ACE2,TWEAK,and CCL5 with CGI-S,CRT,and PSQ scores in the severe group.Receiver operating characteristic(ROC)curve was applied to analyze the diagnostic value of ACE2,TWEAK,and CCL5 for ADHD and severity.Results The serum ACE2(284.35±92.34 pg/ml)and TWEAK(2.56±0.76 pg/ml)levels in children with ADHD were lower than those in the control group(379.23±106.28 pg/ml,3.52±1.12 pg/ml),while CCL5(7.36±2.37 ng/ml)level was higher than that in the control group(5.24±1.63 ng/ml),and the differences were statistically significant(t=7.244,7.703,7.753,all P<0.05).The levels of CRT,serum ACE2 and TWEAK in the severe group were lower than those in the mild to moderate group(t=5.318,6.686,6.490),while the levels of PSQ and CCL5 were higher than those in the mild to moderate group(t=5.220,6.134),and the differences were statistically significant(all P<0.05).Spearman correlation analysis results showed that the serum ACE2 and TWEAK levels in the severe group were negatively correlated with CGI-S and PSQ scores(r=-0.432,-0.453;-0.421,-0.426,all P<0.001),but positively correlated with CRT scores(r=0.427,0.418,all P<0.000 1).CCL5 was positively correlated with CGI-S and PSQ scores(r=0.421,0.433,all P<0.001),but negatively correlated with CRT scores(r=-0.446,P<0.001).The AUCs for diagnosing ADHD by serum ACE2,TWEAK and CCL5 were 0.814,0.803 and 0.807,respectively,and the AUC of the combined diagnosis of the three was 0.945,which was better than individual diagnosis(Z=5.439,4.258,5.576,all P<0.001).The AUCs for diagnosing severe ADHD by serum ACE2,TWEAK and CCL5 were 0.853,0.796 and 0.805,respectively,and the AUC of the combined diagnosis of the three was 0.930,which was better than the individual diagnosis(Z=2.604,3.851,3.567,all P<0.001).Conclusion Serum ACE2 and TWEAK are low expressed in the serum of children with ADHD,while CCL5 is highly expressed.The expression levels of the three are correlated and have high diagnostic value for the occurrence and severity of ADHD.
6.Effect of electroacupuncture on Aβ and insulin degrading enzyme in the frontal cortex of senescence accelerated mouse/prone 8
Baoguang SHI ; Song YU ; Yue WANG ; Lu REN ; Xu WANG
Chinese Journal of Behavioral Medicine and Brain Science 2018;27(2):145-149
Objective To observe the effect of electroacupuncture at " Baihui"," Shenshu" and " Taixi" points on learning and memory,the expression of Aβ and insulin degrading enzyme(IDE) in the brain of SAMP8 mice.Methods Eight-month-old SAMR1 and SAMP8 mice were treated with electroacupuncture at " Baihui"," Shenshu" and "Taixi" points for eight consecutive weeks.The distribution and expression of Aβ and IDE in the brain prefrontal cortex of mouse were observed using immunohistochemistry and Western blot.Learning and memory function was assayed by Morris water maze(MWM).Results Compared with the normal control group,the brain prefrontal cortex of SAMP8 mice showed increased Aβ levels ((179.02± 15.11) %),decreased IDE protein expression ((51.35 ± 14.94) %).MWM showed the escape latency in SAMP8 mice was significantly longer than that in the control group (P<0.05).Compared with the model group,Aβ levels in SAMP8 mice were markedly decreased in electroacupuncture group((119.72±9.21)%) and memantine-treated group ((116.84 ± 12.09) %).IDE protein levels were increased by ((92.06 ± 8.05) %) and ((83.84± 15.28) %) after treatment with electroacupuncture and memantine relative to model group.MWM showed the escape latency was significantly shorter in SAMP8 mice treated with electroacupuncture and memantine than that in the model group(P<0.05).Conclusion Electroacupuncture at " Baihui"," Shenshu" and "Taixi" points can inhibit Aβ levels,increase the expression of IDE and improve the learning and memory function of SAMP8 mice.
7.Clinical analysis of 4 cases of Leigh syndrome in children
Lihui WANG ; Huacheng ZHENG ; Huafang YANG ; Ling YUE ; Yuexian ZUO ; Baoguang LI ; Xiaopu CUI
Journal of Clinical Pediatrics 2016;(2):111-114
Objective To explore the clinical manifestation, diagnosis and prognosis of Leigh syndrome in children. Method Clinical data from 4 cases of Leigh syndrome conifrmed by genetic testing were retrospectively analyzed. The related literature were reviewed. Results In 4 cases, 3 were boys and one was a girl, 3 cases were onset in infant and one case was in school age. The main manifestations were mental retardation, low muscle tone, convulsions, feeding dififculties, drooping eyelids, extraocular muscle paralysis and nystagmus, irritation, activity intolerance etc. The brain magnetic resonance imaging (MRI) revealed symmetry long T1, T2 abnormal signal in brainstem, bilateral globus pallidus, thalamus, cerebellar dentate nuclei, and periaqueductal, 3 cases involved midbrain, one case involved thalamus, and one case involved cerebellar dentate nuclei;2 cases had encephalatrophy. Electromyography was normal in all cases. The levels of lactate in blood and cerebrospinal lfuid were increased. Mitochondrial DNA (mtDNA) detection found the mutation of mtDNA 8993 T>G in one case, and the mutation of mtDNA 9176 T>C in another 3 cases. The case onset in school age died of respiratory failure one month later, and another 3 cases were still in follow up, there were mental retardation, but no signiifcant setback. Conclusion The clinical manifestations of Leigh syndrome in children are diverse. The diagnosis is based on the typical clinical manifestations and MRI, blood and/or cerebrospinal lfuid lactate levels. The genetic testing is the golden standard for diagnosis.
8.Biological safety of hydrophobic acrylic foldable intraocular lens
Xiaojie DUAN ; Baoguang JIANG ; Zhaoxu WANG
Chinese Journal of Tissue Engineering Research 2015;(34):5485-5490
BACKGROUND:Hydrophobic acrylic foldable intraocular lens should be evaluated biologicaly with New Zealand rabbits as implant objects prior to clinical trial. OBJECTIVE:To observe the biological safety of hydrophobic acrylic foldable intraocular lens. METHODS: Twelve New Zealand rabbits were enroled. The right eyes were implanted with self-developed hydrophobic acrylic foldable intraocular lens (Shenyang Baiao Medical Device Co., Ltd., China) as experimental group, and the left eyes were implanted with Acrysof IQ SN60WF (Alcon, USA) as control group. RESULTS AND CONCLUSION: After implantation, there were no significant differences in the cornea, anterior chamber, implant position, posterior segment of eyebal between two groups. Tissue proliferation had no obviously difference between the two groups, and there were cornea and lens pouch inflammations. No macrophages and other inflammatory cels were visualized on the surface of intraocular lens, and fibrous tissues were found on the intraocular lens surface and in the haptics root. These findings suggest that the self-developed hydrophobic acrylic foldable intraocular lens has no difference from Acrysof IQ SN60WF widely used in clinic, and it has the biological safety.

Result Analysis
Print
Save
E-mail