1.Clinical study of percutaneous transluminal coronary intravascular lithotripsy angioplasty for severe left main coronary artery calcification guided by intravascular ultrasound percutaneous coronary
Feng-Qi LIU ; Jun BAO ; Bai-Hong LI ; Chong-Hao CHEN ; Chang-Zheng GAO ; Yun-Feng GUO ; Xin GU ; Jian-Bin GU ; Xiao-Yan WANG
Chinese Journal of Interventional Cardiology 2024;32(7):383-389
Objective To explore the effectiveness and safety of percutaneous coronary artery shock wave balloon angioplasty(IVL)under the guidance of intravascular ultrasound(IVUS)for the treatment of severe calcification lesions in the left main artery(LM).Methods A total of 26 patients with severe LM(mouth,body,bifurcation)calcification admitted to Jiangnan University Affiliated Hospital from October 2022 to April 2024 were included,with an average age of 72.0(61.8,75.4)years.Under the guidance of IVUS,IVL was used for pre-treatment of calcified lesions,followed by percutaneous coronary intervention(PCI)with stent/drug balloon implantation.All patients were evaluated using IVUS before and after the use of IVL and after PCI.And compare the IVUS intracavity related data before and after treatment[plaque burden(PB)、minimum lumen area(MLA)、minimum lumen diameter(MLD)]and calcification fracture number,minimum stent area(MSA),stent expansion coefficient(expansion,EXP),etc.Results There were 26 patients(2 with opening lesions,7 with body lesions,and 17 with bifurcation lesions at the end of the main trunk),including 7 with stable angina pectoris(SAP),10 with unstable angina(UA),4 with acute ST-segment elevation myocardial infarction(STEMI),and 5 with non ST-segment elevation myocardial infarction(NSTEMI).The PB at the most severe site of calcification decreased by 79.50(76.00,83.75)%compared to 80.00(76.00,83.75)%after IVL(P=0.001),MLA increased by 3.39(3.14,3.68)mm2 compared to 3.38(3.14,3.67)mm2 after IVL(P=0.039),MLD increased by 3.21(3.07,3.30)mm compared to 3.20(3.07,3.30)mm after IVL(P=0.024),and there was 100%calcification rupture(1/2 cases,2/9 cases,≥3/15 cases).The stent/drug ball was successfully implanted 100%,with EXP of(89.15±4.42)%and an MSA of 7.20(6.46,7.45)mm2.No adverse events such as death,angina or recurrent myocardial infarction occurred during the 3 months follow-up after surgery.Conclusions After evaluation by IVUS and pre-treatment with IVL,PCI was successfully completed for severe calcification lesions in LM,and IVL can be used as an option for the treatment of severe calcification in LM.
2.Relative Quantification for Obtaining the IgG Blood Group Antibodies in Plasma by the Absorption and Elution Test
Xi QI ; Lin-Bao GAO ; Sheng-Xia CHEN
Journal of Experimental Hematology 2024;32(4):1278-1283
Objective:To establish the absorption and elution test for relatively quantitive obtaining anti-A and anti-B blood group IgG antibodies in the plasma of O-type RhD-positive pregnant women.Methods:95 cases of the O-type RhD-positive pregnant women plasma samples were randomly selected for obtaining the IgG antibodies of anti-A and anti-B blood group,with absorption test under 37 ℃ and elution test under 56 ℃,and the IgG anti-A and anti-B antibody titers of plasma and elution were determined by the microcolumn gel anti-human globulin test.The differences and correlation between the titers of IgG antibodies in the eluent and plasma were compared and analyzed.Results:After a logarithmic transformation(Log2),there was no statistically difference between IgG antibody anti-A difference value and anti-B difference value in the eluent and plasma(P>0.05).The titer of IgG antibody in the eluent was positively correlated with the titer of IgG antibody in the plasma(r=0.914).The linear equation for IgG antibody titers fitted by a scatter plot between the eluent and plasma was Y=-3.55+0.96X.Conclusion:The absorption and elution test can be used to obtain the anti-A and anti-B IgG antibodies in the plasma of O-type RhD-positive pregnant women,whose plasma origin IgG titer is greater than 8.Meanwhile,the acquisition of anti-A antibodies was as effective as anti-B antibodies at the same time,and the antibodies obtained are positive proportional to their respective concentrations in the plasma.
3.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
4.Effects of Didang Decoction-containing serum on high glucose-induced injury of rat glomerular endothelial cells
Bao-Lu LUO ; Quan-Gen CHU ; Jun CHU ; Fei-Xiang LI ; Jing CHEN ; Yue-Qi WANG
Chinese Traditional Patent Medicine 2024;46(9):2930-2935
AIM To investigate the protective effects of Didang Decoction-containing serum on rat glomerular endothelial cells(RGECs)following high glucose injury.METHODS Rats were given distilled water or Didang Decoction by gavage to prepare the blank serum or Didang Decoction-containing serum.CCK8 method was used to screen the glucose concentration for the modeling and serum concentration of the drug.The RGECs were divided into the blank group,the model group,Didang Decoction group(10%Didang Decoction medicated serum),Dapagliflozin group(normal serum+2 μmol/L Dapagliflozin)and Didang Decoction+Dapagliflozin group(10%Didang Decoction medicated serum+2 μmol/L Dapagliflozin).24 hrs after the drug treatment,the RGECs had their mRNA and protein expressions of Nrf2,HO-1 and NQO-1 detected by RT-qPCR method and Western blot method;their Nrf2 fluorescence expression detected by immunofluorescence method;and their SOD activity and MDA level detected by colorimetric method.RESULTS Compared with the blank group,the model group displayed decreased mRNA and protein expressions of Nrf2,HO-1 and NQO-1 as well as the activity of SOD(P<0.01),and increased MDA level(P<0.01).Compared with the model group,the groups intervened with the drugs showed increased mRNA and protein expressions of Nrf2,HO-1 and NQO-1 as well as the activity of SOD(P<0.05,P<0.01),and decreased MDA level(P<0.01).CONCLUSION Didang Decoction-containing serum can protect RGECs from high glucose injury through activating the Nrf2 signaling pathway.
5.The expression of CD24 antigen in multiple myeloma patients and its predictive value after induction therapy
Mengru LIU ; Bin CHU ; Yuan CHEN ; Mengzhen WANG ; Minqiu LU ; Shan GAO ; Lei SHI ; Qiuqing XIANG ; Lijuan FANG ; Qi YAN ; Na JI ; Kai SUN ; Li BAO
Chinese Journal of Laboratory Medicine 2024;47(10):1178-1185
Objective:This study analyzed the expression of CD24 antigen on bone marrow plasma cells (BMPC) of patients with multiple myeloma (MM) and the predictive value of induction therapy.Methods:This clinical observational study utilized 258 MM patients samples treated at the Hematology Department of Beijing Jishuitan Hospital who met the inclusion criteria in the Department of Hematology, Capital Medical University, from August 12th, 2022 to February 1st, 2024. According to the different stages of the disease, patients were divided into three groups: 78 cases of Newly Diagnosed Multiple Myeloma(NDMM) (42 males and 36 females, aged 62±11), 56 cases of the relapse refractory group (34 males and 22 females, aged 64±9), and 124 cases of the disease remission group (68 males and 56 females, aged 62±10). Multiparameter flow cytometry (MFC) was used to detect the expression level of CD24 antigen on BMPC and the relationship between CD24 and MM disease status. The clinical data and test results of 78 NDMM patients at initial diagnosis were retrospectively analyzed, including gender, age, MFC detection of the positive expression rate of antigens (CD19, CD20, CD24, CD27, CD56), the results of efficacy evaluation after induction therapy, ISS staging, R-ISS staging, blood hemoglobin, β2-microglobulin, human serum albumin, serum creatinine, lactate dehydrogenas, correction of calcium, BMPC ratio, and the results of FISH. The patients were divided into a deep remission group [including complete remission (CR) and very good partial remission (VGPR)] with 43 cases and a non-deep remission group (non CR and VGPR) with 17 cases according to the difference of antigen positive expression rate after induction therapy. The differences of antigen expression on BMPC between the two groups were compared. Binary logistic regression was used to analyze the relationship between the expression of each antigen and the efficacy after induction therapy in patients, and the results showed that CD24 was more correlated with the achievement of deep remission after induction therapy than other antigens. Therefore, taking the positive expression rate of CD24 in NDMM patients at the initial diagnosis and deep remission after induction therapy as the research objects, the predictive value of CD24 for NDMM patients reaching deep remission after induction therapy was analyzed by using receiver operating characteristic curve (ROC), and the optimal cutoff value was obtained. NDMM was divided into two groups according to the cut-off value, and the differences between the two groups in clinical baseline data and prognostic indicators were compared.Results:The positive rates of plasma cell CD24 expression in the NDMM group, the relapse refractory group and the disease remission group were 2.18 (95% CI 0.08-81.85)%, 3.81 (95% CI 0.10-64.56)%, 8.74 (95% CI 0.79-95.55)% respectively. Compared with the disease remission group, the NDMM and relapse refractory group was lower ( Z=-7.889, -5.282, respectively, P<0.001). Univariate analysis showed that there was a significant difference in the positive expression rate of CD24 at initial diagnosis between the deep remission group and the non-deep remission group ( Z=-3.265, P<0.001), while there was no significant difference in CD19 ( Z=-0.271, P=0.787), CD20 ( Z=-0.205, P=0.837), CD27 ( Z=-0.582, P=0.560), and CD56 ( Z=-0.328, P=0.743) between the two groups. Binary logistic regression analysis showed that compared with other antigens [CD19 ( OR=1.045, 95% CI 0.975-1.120, P=0.217), CD20 ( OR=1.000, 95% CI 0.971-1.030, P=0.976), CD27 ( OR=0.997, 95% CI 0.977-1.016, P=0.734), CD56 ( OR=1.006, 95% CI 0.990-1.006, P=0.449)], the expression of CD24 ( OR=0.423, 95% CI 0.990-1.006, P=0.449) on BMPC in NDMM patients was most closely related to the achievement of deep remission was achieved after induction therapy. The lower the proportion of CD24 at the initial diagnosis was, the lower the probability of achieving deep remission after induction therapy was. The area under the curve (AUC) of CD24 in predicting deep remission after induction therapy was 0.772 (95% CI 0.655-0.889, P=0.001), with a sensitivity of 60.50%, a specificity of 85.00%, and the optimal critical value was 2.21%. Compared with the group with plasma CD24 positive rate>2.21%, the group with plasma CD24 positive rate<2.21% had a higher proportion of male (39.47%vs 65.00%, χ2=5.092, P=0.024), ISS stagingⅢ (41.67% vs 58.33%, χ2=6.175, P=0.046), β2 microglobulin (3.19 mg/L vs 4.14 mg/L, Z=-2.257, P=0.024), and BMPC [(8.672±1.827)% vs (19.530±3.188)%, t=-2.963, P=0.004] detected by MFC, and the differences were statistically significant. Conclusions:The low positive rate of plasma cell CD24 is closely related to the higher tumor burden and the worse disease status of MM patients. In addition, the positive expression rate of CD24 is at initial diagnosis can predict the efficacy achieved after induction therapy, and the lower positive rate of CD24 is, the worse the efficacy achieved after induction therapy. At the same time, MFC detection of CD24 is convenient and efficient in the evaluation and prediction of MM.
6.Deep learning-based Gaussian and pepper noise removal method for visual images of surgical instruments
Bao-Ming MIAO ; Wei CHEN ; Hang WU ; Ming YU ; Si-Qi HAN
Chinese Medical Equipment Journal 2024;45(2):1-7
Objective To propose a deep learning-based method for removing Gaussian and pepper noises of the surgical instrument visual images so as to recover the detailed features of the images.Methods A lightweight multi-task progressive network was constructed involving in a multi-feature fusion encoder-decoder network,an attention-guided network and a detail-recovery progressive network,which used the multi-feature fusion encoder-decoder network to predict and eliminate the noise information in the visual images,the attention-guided network to remove the residual noise and the detail-recovery progressive network to restore the underlying detail features of the denoised images.Some of the regular convolutions in the detail recovery progressive network were replaced with depth separable convolutions to realize lightweight design of the network constructed.Denoising experiments were conducted on the publicly available CBSD68 and Kodak24 datasets and the self-constructed surgical instrument noise dataset so as to compare the denoising effects of the network constructed and the traditional methods and the classification accuracies of ResNet-18 model and ResNet-34 model for the denosied images by the network and to analyze computing power and memory usage before and after the lightweight design.Results The network constructed gained better denoising effect than the classical methods for publicly available datasets,and ResNet-18 model and ResNet-34 model had higher accuracies when used to classify the images denoised by the network for the self-constructed surgical instrument noise dataset.Lightweight design had the parameter number and floating point operations(FLOPs)decreased by approximately 27.27%and 29.81%,respectively.Conclusion The proposed lightweight multi-task progressive network behaves well in denoising surgical instrument visual images with reduced computating power consump-tion and memory usage.[Chinese Medical Equipment Journal,2024,45(2):1-7]
7.Discrimination of polysorbate 20 by high-performance liquid chromatography-charged aerosol detection and characterization for components by expanding compound database and library
Wang SHI-QI ; Zhao XUN ; Zhang LI-JUN ; Zhao YUE-MEI ; Chen LEI ; Zhang JIN-LIN ; Wang BAO-CHENG ; Tang SHENG ; Yuan TOM ; Yuan YAOZUO ; Zhang MEI ; Lee Kee HIAN ; Shi HAI-WEI
Journal of Pharmaceutical Analysis 2024;14(5):722-732
Analyzing polysorbate 20(PS20)composition and the impact of each component on stability and safety is crucial due to formulation variations and individual tolerance.The similar structures and polarities of PS20 components make accurate separation,identification,and quantification challenging.In this work,a high-resolution quantitative method was developed using single-dimensional high-performance liquid chromatography(HPLC)with charged aerosol detection(CAD)to separate 18 key components with multiple esters.The separated components were characterized by ultra-high-performance liquid chro-matography-quadrupole time-of-flight mass spectrometry(UHPLC-Q-TOF-MS)with an identical gradient as the HPLC-CAD analysis.The polysorbate compound database and library were expanded over 7-time compared to the commercial database.The method investigated differences in PS20 samples from various origins and grades for different dosage forms to evaluate the composition-process relationship.UHPLC-Q-TOF-MS identified 1329 to 1511 compounds in 4 batches of PS20 from different sources.The method observed the impact of 4 degradation conditions on peak components,identifying stable components and their tendencies to change.HPLC-CAD and UHPLC-Q-TOF-MS results provided insights into fingerprint differences,distinguishing quasi products.
8.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
9.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
10.Changes in the microstructure and bone mineral density of vertebral tra-becular bone in the early stages of spinal Mycobacterium tuberculosis in-fection
Jun-Bao CHEN ; Yi LUO ; Nan-Jun XIONG ; Xiao-Jiang HU ; Chao-Feng GUO ; Qi-Le GAO ; Yan-Bing LI
Chinese Journal of Infection Control 2024;23(8):1001-1006
Objective To observe and compare the changes of vertebral bone mineral density(BMD)in the early stages of spinal Mycobacterium tuberculosis infection.Methods Patients who underwent spinal surgery at Xiangya Hospital,Central South University from January 1 to December 31,2023 were continuously enrolled(spinal tuber-culosis group),based on gender matching,non-spinal tuberculosis surgical patients treated for spinal stenosis were selected as the control group.Dual-energy X-ray scans were performed on the enrolled patients,difference in verte-bral BMD between two groups of patients was compared.An animal model of spinal Mycobacterium tuberculosis in-fection(referred to as the animal model)was constructed,differences in microstructure of trabecular bone between spinal tuberculosis group and control group was compared,and the bone volume/tissue volume(BV/TV),the thickness of trabecular bone(Tb.Th),the number of trabecular bone(Tb.N),and sparse density of trabecular(Tb.Sp)were used as evaluation indexes to further analyze the bone quality differences between the diseased verte-brae and the neighboring vertebrae.Results 69 patients were included in the spinal tuberculosis group and the con-trol group,respectively.The BMD of patients in the spinal tuberculosis group(0.793[0.712,0.869]g/cm2)was lower than that of the control group(0.907[0.800,1.020]g/cm2),difference was statistically significant(P<0.05).Microstructure of trabecular bone BV/TV([18.4±5.4]%),Tb.Th([0.124±0.010]mm)in the spinal tuberculosis group of animal model were significantly altered compared with BV/TV([22.6±3.2]%),Tb.Th([0.160±0.017]mm)in the control group(both P<0.05).In the spinal tuberculosis group,microstructure of diseased vetebral trabecular bone BV/TV([25.5±6.7]%)and Tb.N([1.871±0.443]/mm)were significantly lower than BV/TV([26.6±6.8]%)and Tb.N([1.969±0.454]/mm)in the neighboring vertebrae,both with statistically difference(both P<0.05).Conclusion In the early stages of spinal Mycobacterium tuberculosis infec-tion,microstructure of vertebral trabecular bone can be altered,leading to a decrease in BMD.

Result Analysis
Print
Save
E-mail