1.Cloning, subcellular localization and expression analysis of SmIAA7 gene from Salvia miltiorrhiza
Yu-ying HUANG ; Ying CHEN ; Bao-wei WANG ; Fan-yuan GUAN ; Yu-yan ZHENG ; Jing FAN ; Jin-ling WANG ; Xiu-hua HU ; Xiao-hui WANG
Acta Pharmaceutica Sinica 2025;60(2):514-525
The auxin/indole-3-acetic acid (Aux/IAA) gene family is an important regulator for plant growth hormone signaling, involved in plant growth, development, as well as response to environmental stresses. In the present study, we identified
2.Relationship between changes in classroom lighting environment and refractive progression among primary and secondary school students
HAN Di, LING Ruizhe, ZHANG Liye, WANG Yuehong, BAO Xinyu, SHEN Hui, HU Jia
Chinese Journal of School Health 2025;46(11):1549-1553
Objective:
To analyze the changes in classroom lighting environment of schools in Suzhou and their impact on refractive progression among primary and secondary school students, so as to provide the basis for accurate provention and control of myopia.
Methods:
A baseline investigation was conducted in October 2022 by using a stratified cluster random sampling method to recruit primary and secondary school students from Suzhou. A follow up visit was performed in October 2023. A total of 12 302 students and 360 classrooms that participated in both surveys were included analysis. The visual acuity progression over one year and classroom lighting conditions were assessed. Group comparisons were performed by using the Wilcoxon or Kruskal-Wallis rank-sum, and Chi-square tests. Multivariate Logistic regression was employed to identify the major factors influencing refractive changes.
Results:
The compliance rate of average illuminance on classroom blackboard surface increased from 72.22% to 75.28%, while the compliance rate of average illuminance on desks decreased from 89.44% to 87.22%, the overall myopia rate among students rose from 59.63% to 66.99% from 2022 to 2023. The average annual progression of equivalent spherical power(SE) in the right eye of students was -0.25(-0.75,0.06)D. Significant statistical differences were observed in the annual mean changes across different school levels, regions, baseline refractive statuses, and classroom lighting environment change groups ( Z/H =316.59, -8.27, 38.80 , 51.01, all P <0.05). Multivariate Logistic regression analysis showed that pre myopia, low myopia, junior high school, senior high school, vocational high school, and improved classroom lighting environment were protective factors of reducing the risk of rapid progression in refractive error ( OR =0.58, 0.69, 0.81, 0.50, 0.28, 0.82, all P <0.05). Conversely, female students and rural students had higher risks of rapid myopia progression ( OR =1.09, 1.42, both P <0.05).
Conclusions
Over one year follow up, the complance rate of classroom lighting indicators in Suzhou remaines stable, while students refractive status shows a trend toward myopia. Improving classroom lighting environment can reduce the risk of rapid myopia progression.
3.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
4.Modal testing study of three-axis manned centrifuge under elastic boundary conditions
Hai-Xia WANG ; Ke JIANG ; Zhao JIN ; Yi WANG ; Li-Hui ZHANG ; Yan XU ; Cong WANG ; Ming-Hao YANG ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Yuan-Jing ZHENG ; Bao-Hui LI
Chinese Medical Equipment Journal 2024;45(8):38-43
Objective To explore the modal testing method for the three-axis manned centrifuge under elastic boundary conditions with considerations on its complicated structure and high rotational inertia.Methods Modal testing was carried out with a three-axis manned centrifuge under elastic boundary conditions as the subject and a force hammer as the excitation source according to GJB 2706A-2008 Modal tests method for spacecraft and GB/T 11349.3-1992 Experimental determination of mechnical mobility measurements using impact excitation.Four times of hammering were carried out at each excitation position,and the data of the four times of hammering underwent linear average computation.Data acquisition was implemented with a three-axis accelerometer and a 64-channel data collector,and the modal data were analyzed using a frequency response function based on the Test.Lab modal test and analysis software.Results The coherence coefficient of the excitation signal was not lower than 0.8 in the 30 Hz band;the first three orders of the system's intrinsic vibrations were all torsional vibrations,with the frequencies of 9.15,15.66 and 19.22 Hz,respectively;the first order frequency of the system was about 9.15 Hz for both Z18 and Z21 excitation positions,and each of the second and third order frequencies similar situations were observed for also had a roughly equal value for the two excitation positions.Conclusion The force hammer testing method is applicable for the modal testing of the three-axis manned centrifuge,ensuring equipment safety and subject comfort.Referen-ces are provided for the following structural optimization design.[Chinese Medical Equipment Journal,2024,45(8):38-43]
5.Design and implementation of high precision ear pulse wave physiological signal detection device for human centrifuge training
Ke JIANG ; Ming-Hao YANG ; Hai-Xia WANG ; Bao-Hui LI ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Zhong-Zheng GUO ; Xiao-Yang WEI
Chinese Medical Equipment Journal 2024;45(9):35-40
Objective To design and implement a high-precision ear pulse wave physiological signal detection device for human centrifuge training to solve the problems in measurement and calibration of pilot ear pulse wave signal during human centrifuge training.Methods The high-precision ear pulse wave physiological signal detection device was composed of an ear pulse wave acquisition sensor,a signal acquisition and control unit and a host signal processing module.The ear pulse wave acquisition sensor had an ear-clip-like shape and consisted of an outer shell,an inner shell and an elastic steel plate;the signal acquisition and control unit was made up of an power supply module,a constant voltage module for the light source,a signal acquisition module,a master control module and a data transmission module,which had its software developed with an embedded system;the host signal processing module divided the signal processing into 2 phases of signal pre-processing and pulse wave signal monitoring and display.The detection performance of the device was verified by using a physiological electrical signal calibrator to test the ear pulse wave signals detected with the device;the effectiveness and stability of the device were validated by implementing human centrifuge training experiments with different loads.Results The voltage measurement error,amplitude-frequency characteristics and common mode rejection ratio detected by this device were all within the permitted ranges of JJG 760-2003 Verification Regulation for Electro Cardiac Monitor and JJG 954-2019 Verification Regulation of Digital Electroencephalographs;the device was capable of detecting the ear pulse wave signals of pilot during human centrifuge training in real time with little interference from motion and stable signal quality.Conclusion The device can accurately clarify the changes in the amplitude of the pilot's ear pulse wave during human centrifuge training and effectively reflect the changes in the pilot's cerebral blood flow under positive acceleration.[Chinese Medical Equipment Journal,2024,45(9):35-40]
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
8.Clinical characteristics and all-cause mortality influencing factors of 176 patients with Keshan disease
Shujuan LI ; Ying HONG ; Jianzhong BAO ; Rong LUO ; Huihui MA ; Hongmei ZHANG ; Wei CAI ; Feng LI ; Jinshu LI ; Hui HUANG ; Mingjiang LIU ; Anwei WANG ; Ningbo HUANG ; Xiaoping LI
Chinese Journal of Endemiology 2024;43(6):482-486
Objective:To analyze the clinical characteristics and all-cause mortality influencing factors of patients with Keshan disease.Methods:Clinical data of patients with Keshan disease from Keshan disease areas in Sichuan Province and Yunnan Province were collected and retrospectively analyzed for clinical characteristics and survival status during regular follow-up. According to the survival status of patients, the survey subjects were divided into a survival group and a death group. All-cause mortality (referring to the death caused by various reasons throughout the follow-up period) was used as the study endpoint. Kaplan-Meier (K-M) survival curve analysis and log-rank χ 2 test were performed, univariate and multivariate Cox regression analysis were used for all-cause mortality factor analysis. Results:A total of 176 patients with Keshan disease were collected, including 92 cases in Sichuan Province and 84 cases in Yunnan Province. Among all the patients, there were 105 males, accounting for 59.66%, and 71 females, accounting for 40.34%. The age was (53.89 ± 13.19) years old. Thirty-five cases died from all causes, with a mortality rate of 19.89%. There were significant differences in age ( t = 2.09, P = 0.038), New York Heart Association (NYHA) cardiac function grading (χ 2 = 14.62, P < 0.001) and ventricular premature contraction (χ 2 = 6.82, P = 0.009) between the survival group and the death group. K-M survival curve analysis showed that patients with Keshan disease complicated by premature ventricular contraction and high NYHA cardiac function grading (Ⅲ and Ⅳ) had higher all-cause mortality (log-rank χ 2 = 8.72, 22.49, P < 0.05). Univariate Cox regression analysis showed that NYHA cardiac function grading and ventricular premature contraction ( HR = 3.09, 2.71, P < 0.05) were predictive influencing factors for all-cause mortality in patients with Keshan disease. Multivariate Cox regression analysis showed that NYHA cardiac function grading ( HR = 6.57, P = 0.002) and ventricular premature contraction ( HR = 2.98, P = 0.050) were independent factors for all-cause mortality in patients with Keshan disease. Conclusions:Among 176 patients with Keshan disease, the number of patients with poor cardiac function (NYHA cardiac function grading Ⅲ and Ⅳ) and arrhythmia is high. NYHA cardiac function grading and ventricular premature contractions are independent influencing factors for all-cause mortality in patients with Keshan disease.
9.Sentinel surveillance data of influenza in Hunan Province from 2014 to 2023
Xiao-Lei WANG ; Chao-Yang HUANG ; Qian-Lai SUN ; Zhi-Hong DENG ; Yi-Wei HUANG ; Shan-Lu ZHAO ; Kai-Wei LUO ; Xiang REN ; Sheng-Bao CHEN ; Zhi-Hui DAI
Chinese Journal of Infection Control 2024;23(11):1413-1420
Objective To understand the prevalence characteristics of influenza and changes of influenza virus strains,and provide reference for the prevention and control of influenza in the province.Methods Surveillance da-ta about influenza in Hunan Province from 2014 to 2023 were exported from China Influenza Surveillance Informa-tion System.Differences in the percentage of influenza-like illness(ILI)cases(percentage of influenza-like cases[ILI%]in outpatient and emergency department visits)among different years and different populations,as well as the positive rate of influenza virus in ILI specimens were compared.Results From 2014 to 2023,over 2.65 million cases of ILI were reported,with an ILI%of 4.70%.ILI%among different years presented statistically significant differences(P<0.001).People aged 0-14 years old were the main population with ILI,accounting for 82.90%.The positive rate of influenza virus in ILI specimens was 14.14%,the positive rate of influenza virus among diffe-rent years and age groups were both significantly different(both P<0.001).The main prevalent influenza strains from 2014 to 2023 included types A(H1N1),A(H3N2),B(Victoria),and B(Yamagata),alternating among di-fferent years.However,type B(Yamagata)strains were not detected from 2020 to 2023.There were basically two influenza prevalence seasons every year,namely winter-spring and summer.Conclusion People<15 years old are the main population of influenza,and the prevalence peaks are in winter-spring and summer.From 2021 to 2023,the prevalence alternates mainly among 3 types:A(H1N1),A(H3N2),and B(Victoria).
10.Study of precise positioning of post-breast conservative surgery radiotherapy placement using laser positioning coordination system in breast cancer patients
Shufeng ZHANG ; Xiaoyu MA ; Xiaoge SUN ; Qian HUI ; E ERDEMUTU ; Congxiu HUANG ; Jiaxing GUO ; Yingna BAO ; Hongwei WANG ; Xiaoli WU
Chinese Journal of Radiation Oncology 2024;33(7):650-654
Objective:To compare the positioning errors in tracing the body surface markers between radiotherapy placement with or without using the laser positioning coordination system in post-breast conservative surgery patients, and to verify the clinical value of the laser positioning coordination system.Methods:A total of 45 post-breast-conservative surgery patients who underwent radiotherapy in Department of Radiation Oncology of the Affiliated Hospital of Inner Mongolia Medical University from January 2022 to September 2023 were prospectively collected. In the experimental group 1 ( n=15), the initial version of the laser positioning coordination system was employed to trace the body surface markers. In the experimental group 2 ( n=15), the upgraded version of the laser positioning coordination system was adopted to draw the body surface markers. In the control group ( n=15), the body surface markers were traced with conventional approach. All patients were treated with spiral tomotherapy (TOMO), and the error values in the left and right directions ( X), head and foot directions ( Y), ventral and dorsal directions ( Z), and rotation angles (ROLL) before each radiotherapy were recorded. The differences in the positioning errors among the three groups were analyzed by t-test. Results:The positioning errors in the X, Y, Z directions and ROLL in the experimental group 1 were (3.10±2.43) mm, (4.36±3.45) mm, (2.29±2.49) mm and 0.95°±0.88°, and (2.88±2.28) mm, (3.58±2.95) mm, (2.40±2.54) mm, and 0.70°±0.70° in the experimental group 2, and (4.32±3.48) mm, (5.49±4.74) mm, (2.61±3.38) mm and 1.22°±1.16° in the control group, respectively. Statistical significance was observed in the differences of positioning errors in the X, Y directions and ROLL between the experimental group 1 and control group ( t=4.32, 2.89, 2.78, P < 0.001, =0.004, =0.006), respectively. Statistical significance was detected in the differences of positioning errors in the X, Y directions and ROLL between the experimental group 2 and control group ( t=5.20, 5.14, 5.82, all P<0.001). Statistical significance was noted in the differences of positioning errors in the Y direction and ROLL between the experimental group 1 and 2 ( t=2.58, 3.41, P=0.010, 0.001). Conclusion:The laser positioning coordination system-assisted tracing the body surface marking line can significantly reduce the positioning errors in the X and Y directions and ROLL, and the upgraded version of the laser positioning coordination system can further reduce the positioning errors in the Y direction and ROLL compared with the initial version, which is of high clinical application value.


Result Analysis
Print
Save
E-mail