1.Label-free Fluorescence Probe Based on Primer Exchange Reaction for High Sensitivity Detection of Apurinic/Apyrimidinic Endonuclease 1
Yun-Hua WANG ; Le-Ru WANG ; Li-Gai YANG ; Jia-Zheng CHEN ; Yu-Run DU ; Jia-Hui HOU ; Xiang ZHAI ; Xu-Hua ZHAO ; Bao-Feng YU
Chinese Journal of Analytical Chemistry 2025;53(3):464-471
Apurinic/apyrimidinic endonuclease 1(APE 1)is a multifunctional protein that plays important roles in DNA repair and regulation of gene expression.Because APE 1 is overexpressed in various cancers,it can serve as a cancer biomarker for aiding clinical diagnosis,guiding therapy,and monitoring prognosis.On this basis,a label-free fluorescent probe was designed based on the primer exchange reaction(PER)strategy for highly sensitive detection of APE 1 activity.In the absence of APE 1,the structure of catalytic hairpin(HP)was stable and could not form G-quadruplex.Therefore,the background fluorescence of this sensing system was very low due to the dissociation of thioflavin T(ThT).In the presence of APE 1,the apurinic/apyrimidinic(AP)site of HP was cleaved by APE 1 and a short nucleic acid fragment that acted as a primer to initiate PER was generated.After PER reaction,a large number of G-quadruplex were produced,which could specifically bind with ThT and resulted in significant increase of fluorescence signal.The combination of low background design of HP and PER amplification made this biosensor had high sensitivity with a detection limit(3σ)of 0.0008 U/mL.Furthermore,the primer sequence was directly generated by the cleavage of APE 1 without additional addition,which not only increased the specificity of the reaction,but also simplified the experiment procedure.Moreover,the use of label-free fluorescence signal reduced the cost of the experiment,and realized rapid detection of APE 1.Finally,this sensor was used to detect APE 1 in human serum samples with spiked recoveries of 91%-104%,proving great potential in study of biological enzyme.
2.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
3.The predictive value of new simplified insulin resistance assessment indicators for the development of fatty pancreatic disease
Xinyi ZHOU ; Yongpeng ZHAI ; Jiahui WANG ; Xi ZHANG ; Yichen BAO ; Lin ZHOU
Journal of Clinical Hepatology 2025;41(8):1632-1638
Objective To investigate the predictive value of triglyceride glucose-body mass index(TyG-BMI),serum triglyceride-to-high-density lipoprotein cholesterol ratio(TG/HDL-C),and metabolic score for insulin resistance(METS-IR)for fatty pancreatic disease(FPD).Methods A total of 240 patients with FPD treated in The First Affiliated Hospital of Zhengzhou University from January 2020 to November 2023 were included as the case group,while 480 healthy subjects who underwent healthy checks in the same period were randomly selected as the control group.General clinical data and laboratory indicators were collected.The Mann-Whitney U test and chi-square test were used to compare non-normally distributed continuous variables,and categorical variables between groups,respectively.A binary logistic regression model was used to assess the relationship between TyG-BMI,TG/HDL-C,and METS-IR and FPD.The receiver operating characteristic(ROC)curve was plotted,and the area under the curve(AUC)was calculated to evaluate the predictive diagnostic value of those simplified insulin resistance indicators for FPD in the general population and different sex populations.Results Age,BMI,systolic blood pressure,diastolic blood pressure,fasting plasma glucose,uric acid,alanine aminotransferase,aspartate aminotransferase,gamma-glutamyl transferase,total cholesterol,triglyceride,low-density lipoprotein cholesterol,TyG-BMI,TG/HDL-C,and METS-IR in the case group were significantly higher than those in the control group(all P<0.05).The case group had significantly higher proportions of individuals with hypertension,diabetes,and fatty liver disease than the control group(all P<0.05).The high-density lipoprotein cholesterol level was significantly lower in the case group than in the control group(P<0.05).The multivariable Logistic regression analysis showed that after adjusting for various influencing factors,TyG-BMI,TG/HDL-C,and METS-IR remained as independent risk factors for the development of FPD,with the odds ratios(95%confidence intervals)being 1.027(1.018-1.037),6.964(2.022-23.989),and 1.184(1.123-1.248),respectively.In the ROC curve analysis,the AUCs of METS-IR and TyG-BMI were 0.823 and 0.803,respectively,with their sensitivities being 76.3%and 75.8%,specificities being 74.6%and 71.7%,and optimal cut-off values being 34.86 and 196.70,respectively;the next were BMI(AUC=0.758)and TG/HDL-C(AUC=0.734);in the sex-stratified analysis,the AUC values of METS-IR were highest in both the male and female subgroups,which were 0.834 and 0.810,respectively.Conclusion TyG-BMI,TG/HDL-C,and METS-IR show good predictive value for the development of FPD,in which METS-IR is more excellent.
4.Research Progress on Extraction and Isolation,Characterization and Identification of Wear Debris for Artificial Joints
Shu YANG ; Ruijuan LIU ; Jiazhen ZHANG ; Bao ZHAI ; Zikai HUA ; Jinju DING ; Bin LIU
Journal of Medical Biomechanics 2025;40(5):1333-1342
The wear debris generated during artificial joint prosthesis service can react with bone tissues to form osteolysis,seriously affecting the life-time of artificial joint prostheses.This paper reviews,summarizes,and analyzes domestic and international research literature on the extraction,characterization,and identification of wear debris from different artificial joint materials,aiming to provide references and feasible ideas for the future construction of a systematic and hierarchical research system for artificial joint wear debris.The main findings are as follows:strong alkali protein degradation test,strong acid protein degradation test,and protease protein degradation test are the commonly used method for extracting artificial joint wear debris,and researchers have clarified the protein degradation mechanisms of these three debris extraction methods.The characterization of wear debris in-vitro and in-vivo is mostly for hip and knee joints,with a small amount involving cervical spine and ankle joints.Studies have shown that the size,quantity,shape,and volume of wear particles are influenced by factors such as joint type,contact area,material selection,and implantation time.Both domestic and international studies have conducted characterization research on wear debris after in-vitro simulation testing,but there is still a lack of wear debris characterization analysis of clinical retrievals in China.Currently,most research is on the recognition of wear debris in the traditional mechanical field,but research on the intelligent recognition of artificial joint wear debris is relatively few,indicating that there is a certain lag in the application of computer technology in the field of artificial joint wear debris recognition.
5.Research Progress on Extraction and Isolation,Characterization and Identification of Wear Debris for Artificial Joints
Shu YANG ; Ruijuan LIU ; Jiazhen ZHANG ; Bao ZHAI ; Zikai HUA ; Jinju DING ; Bin LIU
Journal of Medical Biomechanics 2025;40(5):1333-1342
The wear debris generated during artificial joint prosthesis service can react with bone tissues to form osteolysis,seriously affecting the life-time of artificial joint prostheses.This paper reviews,summarizes,and analyzes domestic and international research literature on the extraction,characterization,and identification of wear debris from different artificial joint materials,aiming to provide references and feasible ideas for the future construction of a systematic and hierarchical research system for artificial joint wear debris.The main findings are as follows:strong alkali protein degradation test,strong acid protein degradation test,and protease protein degradation test are the commonly used method for extracting artificial joint wear debris,and researchers have clarified the protein degradation mechanisms of these three debris extraction methods.The characterization of wear debris in-vitro and in-vivo is mostly for hip and knee joints,with a small amount involving cervical spine and ankle joints.Studies have shown that the size,quantity,shape,and volume of wear particles are influenced by factors such as joint type,contact area,material selection,and implantation time.Both domestic and international studies have conducted characterization research on wear debris after in-vitro simulation testing,but there is still a lack of wear debris characterization analysis of clinical retrievals in China.Currently,most research is on the recognition of wear debris in the traditional mechanical field,but research on the intelligent recognition of artificial joint wear debris is relatively few,indicating that there is a certain lag in the application of computer technology in the field of artificial joint wear debris recognition.
6.The predictive value of new simplified insulin resistance assessment indicators for the development of fatty pancreatic disease
Xinyi ZHOU ; Yongpeng ZHAI ; Jiahui WANG ; Xi ZHANG ; Yichen BAO ; Lin ZHOU
Journal of Clinical Hepatology 2025;41(8):1632-1638
Objective To investigate the predictive value of triglyceride glucose-body mass index(TyG-BMI),serum triglyceride-to-high-density lipoprotein cholesterol ratio(TG/HDL-C),and metabolic score for insulin resistance(METS-IR)for fatty pancreatic disease(FPD).Methods A total of 240 patients with FPD treated in The First Affiliated Hospital of Zhengzhou University from January 2020 to November 2023 were included as the case group,while 480 healthy subjects who underwent healthy checks in the same period were randomly selected as the control group.General clinical data and laboratory indicators were collected.The Mann-Whitney U test and chi-square test were used to compare non-normally distributed continuous variables,and categorical variables between groups,respectively.A binary logistic regression model was used to assess the relationship between TyG-BMI,TG/HDL-C,and METS-IR and FPD.The receiver operating characteristic(ROC)curve was plotted,and the area under the curve(AUC)was calculated to evaluate the predictive diagnostic value of those simplified insulin resistance indicators for FPD in the general population and different sex populations.Results Age,BMI,systolic blood pressure,diastolic blood pressure,fasting plasma glucose,uric acid,alanine aminotransferase,aspartate aminotransferase,gamma-glutamyl transferase,total cholesterol,triglyceride,low-density lipoprotein cholesterol,TyG-BMI,TG/HDL-C,and METS-IR in the case group were significantly higher than those in the control group(all P<0.05).The case group had significantly higher proportions of individuals with hypertension,diabetes,and fatty liver disease than the control group(all P<0.05).The high-density lipoprotein cholesterol level was significantly lower in the case group than in the control group(P<0.05).The multivariable Logistic regression analysis showed that after adjusting for various influencing factors,TyG-BMI,TG/HDL-C,and METS-IR remained as independent risk factors for the development of FPD,with the odds ratios(95%confidence intervals)being 1.027(1.018-1.037),6.964(2.022-23.989),and 1.184(1.123-1.248),respectively.In the ROC curve analysis,the AUCs of METS-IR and TyG-BMI were 0.823 and 0.803,respectively,with their sensitivities being 76.3%and 75.8%,specificities being 74.6%and 71.7%,and optimal cut-off values being 34.86 and 196.70,respectively;the next were BMI(AUC=0.758)and TG/HDL-C(AUC=0.734);in the sex-stratified analysis,the AUC values of METS-IR were highest in both the male and female subgroups,which were 0.834 and 0.810,respectively.Conclusion TyG-BMI,TG/HDL-C,and METS-IR show good predictive value for the development of FPD,in which METS-IR is more excellent.
7.Discussion and Concern on Animal Study for Orthopaedic Implantable Devices.
Jiazhen ZHANG ; Bao ZHAI ; Ruhan A ; Le JIN ; Yajuan GUO ; Xinli SHI
Chinese Journal of Medical Instrumentation 2023;47(5):550-556
In recent years, new orthopaedic implantable devices continue to emerge, which require higher requirements for technical evaluation. Animal study is an important part of the research and development process for the new orthopedic implantable devices, which provides relevant evidence for product design and stereotyping. By introducing the purpose of animal study, and the application of 3R principle (replacement, reduction, refinement) in this field, we summarize the concern on the animal study, in order to provide reference for the development and research of new orthopedic implantable devices and biomaterials. At the same time, the application of evidence-based research methods such as systematic review in the field is introduced, which provides new tools and approaches for the technical review and regulatory science.
Animals
;
Orthopedics
;
Biocompatible Materials
;
Prostheses and Implants
;
Research Design
8.Discussion of Application Status and Key Attentions on Registration for Ossicular Replacement Prosthesis.
Jing WU ; Jiazhen ZHANG ; Ruhan A ; Bao ZHAI ; Le JIN ; Xinli SHI
Chinese Journal of Medical Instrumentation 2023;47(6):684-689
The ossicular replacement prosthesis should have good biocompatibility, stability, easy to install, and excellent sound transmission capacity. In this study, the characteristics of ideal materials for the ossicular replacement prosthesis were analyzed by searching the types of materials used in clinical practice and comparing the advantages and disadvantages of various materials and structures. At the same time, in combination with the current evaluation requirements and evaluation experience, the focus of the performance research project of ossicular replacement prosthesis in the process of registration is discussed to clarify the performance evaluation requirements of these products, so as to provide reference for the future work of manufacturers and regulators. The performance evaluation of ossicular replacement prosthesis focuses on its mechanical properties, fixation stability, sound transmission characteristics, biological characteristics, and magnetic resonance compatibility.
Ossicular Prosthesis
;
Ossicular Replacement
;
Sound
;
Prosthesis Design
;
Treatment Outcome
9.Evaluation of internal doses to workers and monitoring of 131I concentration in air in nuclear medicine workplaces
Bao LIN ; Guixiang SUN ; Chaoyu ZHANG ; Hezheng ZHAI ; Yong GUO ; Shuyi ZHANG ; Shaolong LIU ; Zixuan GUO ; Xiaojun CHENG
Chinese Journal of Radiological Medicine and Protection 2023;43(9):717-723
Objective:To asscentain the 131I activity concentration in 131I treatment workplaces and to explore the method of estimating the internal dose to workers by air sampling and to analyze its influencing factors. Methods:Air sampling method was used to collect aerosols containing radioactivity in 10 randomly selected workplaces in Zhengzhou where 131I therapy was performed. Aactivity concentration of 131I in treatment workplace was measured for gamma emitters by gamma-ray spectrometry. The internal dose due to 131I inhalation was estimated based on measurement result and field investigation result. Results:The activity concentration of 131I in air samples from 19 subpacking rooms ranged from 0.087 to 570 Bq/m 3, with an average of (51.04 ± 128.58) Bq/m 3. Those from 11 wards ranged from 0.162 to 54.6 Bq/m 3, with an average of (7.97 ± 15.89) Bq/m 3. In terms of the work hours recommended by the national standard GBZ 129-2016 Specifications for individual monitoring of occupational internal exposure, the estimated annual effective dose to radiation workers due to the inhalation of 131I ranges from 0.002 to 10 mSv, with an average of (0.61 ± 1.80) mSv, below the dose limit specified in the national standards. Conclusions:The samples with high 131I activity concentration in nuclear medicine workplaces of 10 medical institutions selected in Zhengzhou are mostly distributed in tertiary class hospitals operating large amount of radionuclide with large numbers of thyroid cancer patients adimitted. The result ing internal dose to radiation workers cannot be ignored. Estimating the internal dose based on the measurement result of air samples has a large uncertainty.However, air sampling method can promptly detect radioactive contamination in case of abnormal events or accidents, providing early warning for workers to carry out dose measurement from external exposure and internal exposure assessment.
10.Detection and Analysis of Blood Dexmedetomidine in Drug-Facilitated Cases.
Wen-Ya ZHAI ; Li-Na WU ; Shuo YANG ; Bao-Hua SHEN ; Yan SHI
Journal of Forensic Medicine 2023;39(5):452-456
OBJECTIVES:
To establish a simple and rapid qualitative and quantitative detection method of dexmedetomidine in blood.
METHODS:
Blood was separated on the Allure PFP Propyl liquid chromatography column with isocratic elution after it was precipitated by acetonitrile and filtered. Qualitative and quantitative analysis of dexmedetomidine was performed using positive ion scan mode and multi-reaction monitoring mode.
RESULTS:
The limit of detection of dexmedetomidine in blood was 0.2 ng/mL and the limit of quantification was 0.5 ng/mL. The linearity of the method was good in the range of 0.5-1 000 ng/mL, and the correlation coefficient was greater than 0.99. The accuracy of the method was 90.34%-112.67% and the extraction recovery was 50.05%-91.08%, with no significant matrix effect.
CONCLUSIONS
This method is simple, selective and suitable for the qualitative and quantitative analysis of dexmedetomidine in blood, which can provide a reference for drug-facilitated cases involving dexmedetomidine.
Tandem Mass Spectrometry/methods*
;
Chromatography, High Pressure Liquid/methods*
;
Dexmedetomidine/analysis*
;
Reproducibility of Results
;
Chromatography, Liquid/methods*

Result Analysis
Print
Save
E-mail