1.Confirmation and re-examination of reactive anti-TP screening in blood donors
Qin YU ; Tingting XU ; Bangrui CHEN ; Lei ZHAO
Chinese Journal of Blood Transfusion 2026;39(7):928-933
Objective: To confirm the reactive anti-TP ELISA screening results in blood donor samples, and analyze implementaion of re-examination among reactive donors, so as to provide data support for effectively formulating re-examination strategies. Methods: Confirmation tests were performed on 331 samples (including 224 cases with dual-reagent reactivity and 107 cases with single-reagent reactivity) using treponema pallidum particle agglutination assays (TPPA). A total of 136 blood samples were collected from blood donors who have previously tested for anti-TP ELISA with single-reagent reactivity and voluntarily applied for re-examination from 2020 to 2024. Infectious disease indicators were detected in accordance with the "Technical Operating Procedures of Blood Stations (2019 Edition)". Among them, anti-TP screening was performed using ELISA reagents from two different manufacturers, and HBV/HCV/HIV nucleic acid testing was conducted using an individual donation nucleic acid testing (ID-NAT) mode. Supplementary tests (WB or TPPA) were conducted on samples with anti-TP ELISA single-reagent reactivity. A two-sided Pearson's chi-squared test or Fisher's exact test was used to evaluate the differences of the positive rates of anti-TP among different groups or reagents. Results: Among the 331 samples, the confirmed positive rate was 93.75% (210/224) for dual-reagent reactive samples, and 2.8% (3/107) for single-reagent reactive samples. The confirmed positive rates of double reagent reactive samples with different reagent combinations were 91.7% (95% CI: 85.6%-95.5%), 95.6% (95% CI: 85.2%-98.8%), 96.6% (95% CI: 86.2%-97.3%) respectively, with no statistically significant difference (χ
=1.597, P=0.463). From 2020 to 2024, 994 donors showed anti-TP ELISA single-reagent reactive results. Among them, 136 (136/994, 13.68%) donors voluntarily applied for re-examination. After the first round of re-examination, 88 (88/136, 64.71%) donors passed the re-examination, and 18 donors were permanently deffered (18/136, 13.24%). Among the permanently quarantined donors, 12 donors remained anti-TP ELISA single-reagent reactive, including 8 confirmed positive for TP-specific antobodies and 4 with indeterminate results. The remaining 6 donors converted to dual-reagent reactive. Conclusion: The dual-reagent reactive results in anti-TP ELISA has a high true positive rate, and the corresponding blood donors can be directly deffered. The majority of single-reagent reactive anti TP-ELISA results are false positives. Timely confirmation or supplementary testing allows prompt notification of evaluation results to blood donors, and reduces unnecessary follow-up examinations. This helps improve the quality of blood donor services and management efficiency, as well as prevent blood donor attrition.
2.Simultaneous Determination of the Costunolide and Dehydrocostus Lactone in Haoweilai Soft Capsule by HPLC
Mingming ZHAO ; Yuting CHEN ; Bangrui HUANG ; Xiangqun JIN
China Pharmacy 2016;27(15):2099-2101
OBJECTIVE:To establish a method for the simultaneous determination of costunolide and dehydrocostus lactone in Haoweilai soft capsule. METHODS:HPLC was performed on the column of Dikma C18 with mobile phase of acetonitrile- water (V/V,55∶45) at a flow rate of 1.0 ml/min,detection wavelength was 225 nm,column temperature was 25 ℃,and the injection volume was 10 μl. RESULTS:The linear range were 24.00-108.00 μg/ml(r=0.999 7) for costunolide and 20.88-93.98 μg/ml for dehydrocostus lactone (r=0.999 8);RSDs of precision,stability and reproducibility tests were lower than 1%;recoveries were 98.71%-100.00%(RSD=0.25%,n=6)and 96.88%-99.18%(RSD=0.40%,n=6). CONCLUSIONS:The method is simple with good stability and reproducibility,and can be used for the simultaneous determination of costunolide and dehydrocostus lactone in Haoweilai soft capsule.

Result Analysis
Print
Save
E-mail