1.Reyanning Mixture on Asymptomatic or Mild SARS-CoV-2 Infection in Children and Adolescents: A Randomized Controlled Trial.
Xiang-Ru XU ; Shuang ZHOU ; Guo-Qiang JIN ; Hong-Ze WU ; Jin-Hua LI ; Jing ZHOU ; Wei PENG ; Wen ZHANG ; Ding SUN ; Bang-Jiang FANG
Chinese journal of integrative medicine 2023;29(10):867-874
OBJECTIVE:
To assess the effect and safety of Reyanning Mixture (RYN) in treating asymptomatic or mild severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in children and adolescents.
METHODS:
This is a prospective, open-label, randomized controlled trial. Patients aged 1-17 years and diagnosed with asymptomatic or mild coronavirus disease-2019 (COVID-19) were assigned to an intervention group (RYN plus standard care) and a control group (standard care) according to a randomization list. The primary outcomes were SARS-CoV-2 negative conversion time. Secondary outcomes included negative conversion rate on days 3 and 7, hospital length of stay, symptom relief rate, new-onset symptoms of asymptomatic infected patients, and progressive disease rate. The cycle threshold (Ct) values of ORF1ab or N genes were also tested.
RESULTS:
A total of 214 patients in the intervention group and 217 in the control group were analyzed. The SARS-CoV-2 negative conversion time was significantly shortened in the intervention group [5 days (interquartile range (IQR): 5-6) vs. 7 days (IQR: 6-7), P<0.01]. By days 3 and 7, the negative conversion rates were significantly higher in the intervention group (day 3: 32.7% vs. 21.2%, P=0.007; day 7: 75.2% vs. 60.8%, P=0.001). Ct values significantly increase on day 2 [ORF1ab gene: 35.62 (IQR: 29.17-45.00) vs. 34.22 (IQR: 28.41-39.41), P=0.03; N gene: 34.97 (IQR: 28.50-45.00) vs. 33.51 (IQR: 27.70-38.25), P=0.024] and day 3 [ORF1ab gene: 38.00 (IQR: 32.72-45.00) vs. 35.81 (IQR: 29.96-45.00), P=0.003; N gene: 37.16 (IQR: 32.01-45.00) vs. 35.26 (IQR: 29.09-45.00), P=0.01]. No significant difference was found in hospital length of stay between the two groups (P>0.05). Symptoms of cough were significantly improved (82.2% vs. 70.0%, P=0.02) and wheezing was significantly reduced (0.7% vs. 12.9%, P<0.01) in the intervention group compared with the control group. During the trial, no disease progression or serious adverse events were reported.
CONCLUSION
Adding RYN to standard care may be a safe and effective treatment for children with asymptomatic and mild SARS-CoV-2 infection. (Registration No. ChiCTR2200060292).
2.Analysis of mechanisms of Shenhuang Granule in treating severe COVID-19 based on network pharmacology and molecular docking.
Xiang-Ru XU ; Wen ZHANG ; Xin-Xin WU ; Hong-Qiang YANG ; Yu-Ting SUN ; Yu-Ting PU ; Bei WANG ; Wei PENG ; Li-Hua SUN ; Quan GUO ; Shuang ZHOU ; Bang-Jiang FANG
Journal of Integrative Medicine 2022;20(6):561-574
OBJECTIVE:
Severe cases of coronavirus disease 2019 (COVID-19) are expected to have a worse prognosis than mild cases. Shenhuang Granule (SHG) has been shown to be a safe and effective treatment for severe COVID-19 in a previous randomized clinical trial, but the active chemical constituents and underlying mechanisms of action remain unknown. The goal of this study is to explore the chemical basis and mechanisms of SHG in the treatment of severe COVID-19, using network pharmacology.
METHODS:
Ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry was employed to screen chemical constituents of SHG. Putative therapeutic targets were predicted by searching traditional Chinese medicine system pharmacology database and analysis platform, SwissTargetPrediction, and Gene Expression Omnibus (GEO) databases. The target protein-protein interaction network and enrichment analysis were performed to investigate the hub genes and presumptive mechanisms. Molecular docking and molecular dynamics simulations were used to verify the stability and interaction between the key chemical constituents of SHG and COVID-19 protein targets.
RESULTS:
Forty-five chemical constituents of SHG were identified along with 131 corresponding therapeutic targets, including hub genes such as HSP90AA1, MMP9, CXCL8, PTGS2, IFNG, DNMT1, TYMS, MDM2, HDAC3 and ABCB1. Functional enrichment analysis indicated that SHG mainly acted on the neuroactive ligand-receptor interaction, calcium signaling pathway and cAMP signaling pathway. Molecular docking showed that the key constituents had a good affinity with the severe acute respiratory syndrome coronavirus 2 protein targets. Molecular dynamics simulations indicated that ginsenoside Rg4 formed a stable protein-ligand complex with helicase.
CONCLUSION
Multiple components of SHG regulated multiple targets to inhibit virus invasion and cytokine storm through several signaling pathways; this provides a scientific basis for clinical applications and further experiments.
Humans
;
Molecular Docking Simulation
;
Ligands
;
Network Pharmacology
;
Drugs, Chinese Herbal/chemistry*
;
Medicine, Chinese Traditional
;
COVID-19 Drug Treatment
3.Determination of dimethyl sulfate in workplace air by pre-column derivatization-high performance liquid chromatography
YUAN Jing RONG Wei feng HU Jia wen HE Jia heng MENG Rui bo WU Chuan WU Bang hua
China Occupational Medicine 2022;52(04):425-
Abstract: Objective - -
To establish a pre column derivatization high performance liquid chromatography method for detecting
Methods
dimethyl sulfate (DMS) in workplace air. DMS in workplace air was collected with mercaptopyridine impregnated
(
silicone tube. The derivative of DMS and mercaptopyridine was eluted by mobile phase phase A: water, phase B: acetonitrile,
∶
the volume ratio was 40 60) , and separated with a C18 column, then detected with diode array detector and quantitated by a
Results -
standard curve. The linear range of DMS was 0.17 40.00 mg/L, with the correlation coefficient of 0.999 95. The
detection limit and the lower limit of quantitation were 0.05 and 0.17 mg/L respectively. The minimum detection concentration
and minimum quantitation concentration were 0.02 and 0.04 mg/m³, respectively (air sample volume of 4.5 L, 1.0 mL sample
- - -
solution). The average desorption efficiency was 98.40% 102.00%. The within run and between run relative standard deviations
- -
were 0.61% 3.92% and 1.71% 6.00%, respectively. The samples could be stored at room temperature for at least 14 days.
Conclusion
This method can be used to detect DMS in workplace air.
4.Research progress on detection methods for nitrobenzene compounds in air
WU Fan YUAN Jing HU Jia wen HE Jia heng MENG Rui bo WU Bang hua RONG Wei feng
China Occupational Medicine 2022;52(04):443-
Abstract:
Nitrobenzene compounds (NBCs) are widely used in the world. It has 40 isomers such as nitrobenzene, dinitrobenzene
and nitrotoluene, that are highly toxic and difficult to degrade and can cause harm to human health in different degrees. At pres⁃
ent, there is no unified standard method and occupational exposure limit for the detection of NBCs in the air. In terms of sampling
medium, solid adsorption tube is mostly used for trapping vapor state NBCs, and filter membrane and solid adsorption tube are
mostly used in series for sampling coexist NBCs in vapor state and aerosol state. In the detection methods, gas chromatography
and liquid chromatography are common, and ultraviolet spectrophotometry, Raman spectroscopy, ion migration spectrometry and
some other rapid response methods and technologies are also used in the detection of NBCs. In the detection of NBCs by gas chro⁃
matography, capillary column separation is commonly used, and the main detectors are flame ionization detector, electron capture
detector and mass spectrometry detector. It is of practical significance to establish a method with high sensitivity, strong practica⁃
bility, convenient operation, and can simultaneously collect and detect a variety of NBCs in different states.
5.Relationship of urine cobalt and individual exposure levels of cobalt and its compounds in cobalt exposed workers
LUO Xiao ting CHEN Wen DONG Ming WU Chuan LIN Zuo kan TAN Jian ming WU Bang hua
China Occupational Medicine 2022;49(06):615-620
Objective -
To analyze the relationship between cobalt level of post shift urine and individual exposure level of
,
cobalt and its compounds in cobalt exposed workers and to explore the feasibility of using urine cobalt as a biomarker.
Methods -
A total of 148 occupational cobalt exposed workers from a new material company were selected as the exposed
, - -
group and 44 non occupational cobalt exposed workers from the company were selected as the control group using the typical
sampling method. The exposure concentration of time weighted average of cobalt and its compounds in the workplace air of the
-
two groups was determined by inductively coupled plasma mass spectrometry as the individual exposure level. The cobalt levels
- -
of pre shift and post shift urinary samples of the two groups were detected by this method. The linear relationship between the
-
cobalt level of post shift urine and the individual exposure level of cobalt and its compounds in the air of the workplace was
Results - 3
analyzed. The individual exposure level of cobalt and its compounds in the exposed group was 1.10 131.71 μg/m with
(M) 3
the median of 12.23 μg/m. No cobalt and its compounds were detected in the workplace air in the control group. The cobalt
- -
levels of pre shift and post shift urines in exposed group were higher than those in the control group at the same time point
(M: vs , vs , P ) - -
1.54 0.56 μg/L 8.77 0.83 μg/L all <0.01 . The cobalt level of post shift urine was higher than that in pre shift
(M: vs ,P ),
urine in the exposed group 8.77 1.54 μg/L <0.01 and it was positively correlated with the individual exposure level
( ,P ) ,
of cobalt and its compounds Spearman correlation coefficient=0.86 <0.01 . After common logarithm conversion the linear regression equation of the cobalt level of post shift urine and the common logarithm of individual exposure level of cobalt and
(x) :ŷ x( ;F ,
its compounds in the exposed group was as follows = −0.178 + 0.988 coefficient of determination=0.72 =374.75
P ;t , P ) Conclusion -
<0.01 = - 19.36 <0.01 . There was a linear correlation between cobalt level of post shift urine and
occupational cobalt exposure level of cobalt exposed workers. Urinary cobalt can be used as a biomarker of occupational cobalt
6.Chloro-nitrobenzene compounds air sampling tube preparation and determination method
WU fan RONG Wei feng YUAN jing HE Jia heng HU Jia wen MENG Rui bo WU Bang hua YU Ri an
China Occupational Medicine 2022;49(06):697-
Objective - -
To prepare the GDH 5 air sampling tube for simultaneous collection of eight kinds of chloro nitrobenzene
( ) ,
compounds CNBs in the air of workplace and establish a matching determination method using gas chromatography.
Methods - - ,
Eight kinds of CNBs in vapor and aerosol state were collected by self developed GDH 5 air sampling tube desorbed
, , ,
by toluene separated by polysiloxane gas chromatography column detected by microcell electron capture detector and
Results - ( -
quantified by external standard method. It was determined that the air sampling tube was assembled by XAD 2 ion
) - ,
exchange resin and glass fiber filter membrane. The linear range of CNBs was 0.80 240.00 mg/L and the linear correlation
- -
coefficients were greater than 0.999 9. The detection limit was 7.87 13.03 μg/L. The minimum detectable concentration was 0.60
3, - 3( )
1.33 μg/m and the minimum quantitative concentration was 2.00 4.22 μg/m sample 45.00 L . The average desorption
- - (RSD) - , - RSD
efficiency was 101.2% 110.0%. The within run relative standard deviation was 0.8% 4.1% and the between run
- Conclusion -
was 0.3% 5.8%. The samples could be stored for more than 30 days at room temperature. GDH 5 air sampling
tube and its associated determination method can be used for the collection and determination of eight kinds of CNBs in
workplace air.
7. Determination of 12 kinds of chlorobenzene compounds in workplace air by portable gas chromatography-mass spectrometry
Wei-feng RONG ; Bang-hua WU ; Wei-jie LING ; Lin CHEN ; Jing YUAN ; Jia-heng HE ; Rui-bo MENG
China Occupational Medicine 2021;48(05):543-547
OBJECTIVE: To establish a method for simultaneous determination of 12 kinds of chlorobenzene compound(CBs) in workplace air using portable gas chromatography-mass spectrometry(GC-MS) technique. METHODS: The GDH-3 air sampling tube was developed independently, and were used to collect the 12 kinds of CBs in the vapor state and aerosol state in the air. After elution with toluene solvent, portable GC-MS method was used for detection. Fast chromatographic column was used for separation, and then qualitatively analyzed with retention time and characteristics of the ions, and quantitative analyzed by standard curves. RESULTS: The quantitative determination ranges of the 12 kinds of CBs were 0.20-200.00 mg/L. All the correlative coefficients were greater than 0.998 3. All the minimum quantitative concentration was 0.01 mg/m~3, and all the minimum quantitative mass concentration was 0.04 mg/m~(3 )(15 L sample). The average elution efficiency was 88.97%-116.86%. The within-run and the between-run relative standard deviation was 10.15%-13.48% and 12.87%-19.66%, respectively. All the sampling efficiencies were>90.00%. CONCLUSION: The portable GC-MS technique could be used for rapid qualitative and quantitative detection of 12 kinds of CBs in workplace air.
8. Preparation of air sampling tube for chlorobenzene compounds and establishment of its matching detecting method
Wei-feng RONG ; Bang-hua WU ; Wei-jie LING ; Xing-bin HUANG ; Feng-jun DENG ; Luo-piao XU ; Jing YUAN ; Jia-heng HE ; Rui-bo MENG
China Occupational Medicine 2021;48(04):425-430
OBJECTIVE: To prepare and develop a GDH-2 air sampling tube for detecting 12 kinds of chlorobenzenes(CBs) in workplace air and to establish a matching detecting method. METHODS: The self-developed GDH-2 air sampling tube was filled with ion exchange resin and activated carbon, and the mass ratio was 10 ∶1. The GDH-2 air sampling tube was used to collect 12 kinds of CBs with coexistence of gaseous and aerosol in the air. After elution with toluene, they were separated on a chromatographic column and determined by microcell electron capture detector. RESULTS: The quantitative detecting range of the method was 0.51×10~(-3)-6 000.00 mg/L, with the correlation coefficients greater than 0.999 4. The minimum detection concentration was 0.02-61.99 μg/m~3, and the minimum quantitative concentration was 0.05-206.62 μg/m~3. The average desorption efficiency was 90.8%-104.0%. The within-run relative standard deviation(RSD) was 1.0%-5.7%, and the between-run RSD was 3.0%-7.3%. The samples can be stored at room temperature for at least 26 days. CONCLUSION: The self-developed GDH-2 air sampling tube and its matching measuring method can be used for the collection and determination of the 12 kinds of CBs in the air of workplace.
9. Analysis on comparison of inter-laboratory results of chemical volatile organic compounds
Rui-bo MENG ; Wei-feng RONG ; Ai-hua ZHANG ; Fei-fei ZENG ; Jia-wei HU ; Bang-hua WU
China Occupational Medicine 2021;48(02):167-170
OBJECTIVE: To analyze the comparison results of volatile organic components in chemicals tested by occupational health laboratories.METHODS: A total of 37 reference laboratories that participated in the 2019 National Occupational Health Inspection and Testing Institution Laboratory Comparison Chemical Qualitative Testing Comparison organized by Guangdong Occupational Health Testing Center were selected as the research subjects. Headspace gas chromatography-mass spectrometry was used for the determination of volatile organic components in chemicals. The comparison results of reference laboratories were collected and implemented with qualitative and quantitative evaluation. RESULTS: The qualified rates of the qualitative results of the required hazard factors and other hazard factors in the reference laboratories were higher than those of the quantitative results of similar factors with statistical significance(83.78% vs 67.57%, 89.19% vs 56.76%, all P<0.05). There was no significant difference in the qualified rate of qualitative and quantitative results and comprehensive judgment results among each reference laboratory with other hazard factors(83.78% vs 89.19%, 67.57% vs 56.76%, 83.78% vs 89.19%, all P>0.05). The qualified rate of 37 reference laboratories was 89.19%(33/37). It showed no significant difference in the qualified rate of qualitative, quantitative and comprehensive judgment results among the reference laboratories of disease prevention and control system and non-disease prevention and control system(93.75% vs 85.72%, 85.00% vs 61.91%, 93.75% vs 85.52%,all P>0.05). CONCLUSION: There are great differences in the detection ability of volatile organic components on chemicals of each reference laboratory. The ability of qualitative detection is superior to the quantitative detection.
10.Gadolinium angiography of inner ear in patients with sudden deafness and its clinical analysis.
Yong Ping HAN ; Jun Yi ZHANG ; Lei LIU ; Cai Feng LIANG ; Guo Hua MIAO ; Zheng Bang XU ; Lei WU ; Xue Qin DU ; Wen Jie FAN ; Ying XING ; Li Sheng YU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2021;56(7):746-750
Objective: To observe the gadolinium imaging findings of inner ear in patients with sudden deafness and to analyze its clinical features. Methods: From November 2017 to July 2020, 21 patients with sudden deafness in the People's Hospital of Dongsheng District, Ordos City were selected as the research objects, including 14 males and 7 females, aged 36-76 years, with a median age of 50 years. The course of disease was 1-19 days, with an average of 5.5 days. The patients received audiology tests, laboratory examination, and intravenous gadolinium angiography, each of whom was scanned twice by 3D-FLAIR sequence: once before intravenous gadolinium injection, and once again 4.5-6.0 h after intravenous gadolinium injection. The following corresponding clinical treatment was given. The imaging manifestations and clinical features were observed. Results: Among 21 cases of sudden deafness in acute stage, the signal intensity of 11 cases was significantly higher than that of the contralateral ear, and 2 cases had vestibular labyrinthine hydrops. In laboratory examination, only 2 cases of total deafness had increased WBC count and faster erythrocyte sedimentation rate, and the rest had no abnormality. The hearing types of 21 patients with sudden deafness were: total deafness in 8 cases, flat decline in 10 cases, low frequency decline in 1 case, high frequency decline in 2 cases. The total effective rate was 57% (12/21). The hearing types of 11 patients with abnormal gadolinium angiography were total deafness in 5 cases, flat decline in 5 cases and high frequency decline in 1 case. The total effective rate was 64% (7/11). Conclusion: Gadolinium angiography is abnormal in some patients with sudden deafness, and the permeability of blood labyrinth barrier may be increased, which is worthy of further study.
Angiography
;
Deafness
;
Female
;
Gadolinium
;
Hearing Loss, Sudden/diagnostic imaging*
;
Humans
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Vestibule, Labyrinth

Result Analysis
Print
Save
E-mail