1.Performance validation and clinical application evaluation of fluorescent magnetic particle chemiluminescence method for the determination of sIgE
Wenqi SHAO ; Mi ZHOU ; Jing ZHU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Preventive Medicine 2025;59(9):1427-1433
To evaluate the analytical performance of a specific IgE (sIgE) quantitative detection system and explore the clinical application effect of dust mite extract and component detection. The fluorescent magnetic particle chemiluminescence method was used to verify the analytical performance of sIgE for house dust mite (D1), dust mite (D2) extracts, and their components (Der p 1, Der p 2, Der p 10, and Der p 23), including precision, limit of blank (LoB), limit of detection (LoD), linear range, and interfering factors. This is a retrospective cohort study. A total of 50 patients with allergic rhinitis and 50 patients with allergic asthma diagnosed at Zhongshan Hospital Affiliated to Fudan University from January 2022 to August 2023 were selected, along with 70 apparently healthy individuals who underwent physical examinations in the hospital as the healthy control group. The positive rates of each sIgE component in the three groups were compared, and the receiver operating characteristic (ROC) curve for diagnosing dust mite allergy was plotted. The results showed that the fluorescent magnetic particle chemiluminescence method for detecting sIgE demonstrated good repeatability and intermediate precision within the range of 0.1-100 kU/L. The LoB, LoD, and linear range all met the specified requirements. Except for Der p 10, which was interfered by the presence of conjugated bilirubin and free bilirubin (exceeding 40 mg/dl), the detection of other allergens was not significantly affected by common endogenous substances. In healthy individuals, 10% had positive sIgE for dustmite extract; in asthmatic and allergic rhinitis patients, the positive rates were 70% and 82%, respectively. The double positive rate of D1 and D2 in the healthy group was 8.6%, while in asthmatic and allergic rhinitis patients, it was 66% and 70%, respectively. When 0.35 kU/L was used as the threshold, the sensitivity of sIgE for dust mite extract to predict component positivity was 100%, specificity was 61.5%, positive predictive value (PPV) was 80.2%, and negative predictive value (NPV) was 100%. When the threshold was optimized to 0.78 kU/L, the sensitivity was 96.8%, specificity was 92.1%, PPV was 95.2%, and NPV was 94.6%. In conclusion, the repeatability, intermediate precision, LoB, LoD, linear range, and anti-interference ability of the fluorescent magnetic particle chemiluminescence method for detecting sIgE meet the requirements of laboratory quality management. This ensures detection quality, meets clinical needs, and can be used for the auxiliary diagnosis of allergic diseases.
2.Establishment and validation of an autoverification system for coagulation tests stratified by outpatient and inpatient settings
Weitao ZHANG ; Huayang ZHANG ; Jie ZHU ; Chong WANG ; Meixiu GU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Clinical Laboratory Science 2025;43(11):845-850
Objective To establish autoverification rules for six routine coagulation assays(PT,APTT,TT,Fib,DD,and FDP)based on the stratification of outpatients and inpatients,in accordance with CLSI AUTO-10A,AUTO-15,and WS/T 616-2018 guide-lines,and to validate the feasibility of this stratified strategy with clinical data while optimizing verification efficiency.Methods A to-tal of 323 451 coagulation test results from Zhongshan Hospital,Fudan University in 2022 were retrospectively analyzed to define auto-verification rules involving critical values,instrument flags,logical rules,historical comparison,and numerical ranges.A stratified au-toverification system was established by applying distinct rules for outpatient and inpatient populations.Subsequently,the rules were op-timized using 87 830 coagulation test results from January to March 2024,and the consistency between autoverification and manual veri-fication was prospectively evaluated using 33 968 consecutive coagulation specimens collected in April 2024.Results A stratified au-toverification system was successfully developed,comprising a total of 53 rules.The pass rate of overall verification was 77.16%(26 210/33 968),with a true-positive rate of 19.64%(6 672/33 968),a false-positive rate of 3.20%(1 086/33 968),a true-nega-tive rate of 77.16%(26 210/33 968),and no false negatives were detected.Conclusion The proposed autoverification system signifi-cantly improved verification efficiency.The stratified design based on outpatient and inpatient populations effectively minimized the risk of false negatives,and may provide a novel approach for the further development and optimization of coagulation test autoverification.
3.Establishment and evaluation of a method for simultaneous analysis of fluconazole,linezolid,voriconazole and contezolid by liquid chromatography-tandem mass spectrometry
Jiexin LIU ; Lei CAO ; Yingfei PENG ; Jiaqian QIN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Clinical Laboratory Science 2025;43(4):241-245
Objective To establish and validate a method for simultaneous analysis of fluconazole,linezolid,voriconazole and cont-ezolid by liquid chromatography-tandem mass spectrometry,and conduct preliminary assessment its value of application value in clinical therapeutic drug monitoring.Methods Using an isotopic internal standard method,the serum samples were pretreated with protein precipitation.The supernatant was diluted after centrifugation,and detected by liquid chromatography-tandem mass spectrometer.Refer-ring to the Recommendations for Clinical Application of Liquid Chromatography-Mass Spectrometry(LC-MS)and Clinical and Labora-tory Standards Instituhe(CLSI)C62A,the performance of the LC-MS method was verified,including quantitation limits,linearity,trueness,precision,matrix effect,carry-over,interference,dilution consistency and stability.The blood samples from patients who were treated with fluconazole,linezolid,voriconazole,and contezolid were collected and measured for trough or peak concentrations.Results The quantitation limits of fluconazole,linezolid,voriconazole and contezolid by this method were 1 μg/mL,0.25 μg/mL,0.25 μg/mL and 0.1 μg/mL,respectively.The linear ranges were 1-100 μg/mL,0.25-25 μg/mL,0.25-25 μg/mL,and 0.1-10μg/mL,respectively.The recovery rates were 103.0%-105.7%,103.1%-108%,102.4%-106.2%and 101.0%-109.9%,respectively.The precisions,expressed as coefficient of variation(CV),were 1.7%-3.4%,2.1%-4.8%,1.9%-3.1%,and 3.1%-6.8%,respective-ly.No obvious matrix effect,carry-over contamination and interference were found.The dilution consistency and stability were satisfac-tory.The concentrations of fluconazole,linezolid and voriconazole within the reference interval accounted for 49.1%,52.5%and 80.7%of the total samples,respectively.The peak concentration of contezolamide was(14.02±4.94)μg/mL(n=4),and the trough concen-tration was(0.34±0.20)μg/mL(n=5).Conclusion In this study,a method for simultaneous analysis of the concentrations of flu-conazole,linezolid,voriconazole and contezolid was successfully established and verified by liquid chromatography-tandem mass spec-trometry.This method is simple,rapid,and suitable for therapeutic drug monitoring,and providing a basis for the optimization of drug regimens.
4.Clinical application value of serum LncRNA P53RRA in hepatocellular carcinoma
Yafang PAN ; Jing YANG ; Wenqi SHAO ; Te LIU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Clinical Laboratory Science 2025;43(1):20-24
Objective To detect the expression level of serum LncRNA P53RRA in patients with primary hepatocellular carcinoma(HCC)and explore its clinical application value in the diagnosis of HCC.Methods Ninety-three patients with primary HCC visited Zhongshan Hospital Affiliated to Fudan University from November 2019 to December 2020 were selected as the HCC group and 88 healthy individuals undergone physical examination as the control group.Their serum samples were collected and the expression levels of serum LncRNA P53RRA were detected by real-time fluorescence quantitative PCR(qRT-PCR).The correlations of serum P53RRA levels with clinicopathological parameters and clinical biochemical indicators such as alanine aminotransferase(ALT),glutamate amin-otransferase(AST),gamma-glutamyl transpeptidase(GGT),and alkaline phosphatase(ALP)in HCC patients were analyzed.The diagnostic value of serum P53RRA for HCC was evaluated by the receiver operating characteristic(ROC)curve.Results The expres-sion levels of serum P53RRA in HCC patients(2.15±0.22)were significantly lower than that in healthy controls(3.54±0.33),and the difference was statistically significant(t=3.489,P<0.05).The analysis of clinicopathological parameters showed that the expres-sion levels of serum P53RRA in HCC patients were correlated with tumor staging(χ2=9.590,P<0.05),α-fetoprotein(AFP,χ2=5.732,P<0.05),and GGT(χ2=5.732,P<0.05).ROC curve analysis showed that the area under the ROC curve(AUCROC)of ser-um P53RRA in the diagnosis of HCC was 0.750(95%CI:0.679-0.821),with a sensitivity of 65.6%and specificity of 64.8%.The AUCROC,sensitivity and specificity of P53RRA combined with AFP and GGT in the diagnosis of HCC were 0.911(95%CI:0.867-0.953),88.2%and 70.5%,respectively,which were higher than those of single indicator.Conclusion LncRNA P53RRA is expec-ted to serve as a novel non-invasive biomarker,effectively assisting in the clinical diagnosis of HCC.
5.Establishment of reference interval for adult serum CA242 in Shanghai using indirect method
Yafang PAN ; Wenqi SHAO ; Jing ZHU ; Jing YANG ; Baishen PAN ; Beili WANG ; Wei GUO
International Journal of Laboratory Medicine 2025;46(5):530-534
Objective To explore the use of indirect methods to establish a reference interval for serum car-bohydrate antigen 242(CA242)in adults in Shanghai and to validate it.Methods A total of 51 897 cases of CA242 testing data from the laboratory information management system of the Department of Clinical Labo-ratory at the hospital from August 2022 to July 2023 were collected.After data cleaning and normal transfor-mation,the Turkey method was used to remove outliers,and 19 653 cases of data were finally included in the study.Then,the Hoffmann method was used to establish the P95 reference interval for serum CA242.The study selected 691 apparently healthy individuals from January to March 2024 to validate the self built refer-ence interval for CA242.The physical examination population with the reference interval recommended by the reagent instructions≤CA242 value
6.Performance validation and clinical application evaluation of fluorescent magnetic particle chemiluminescence method for the determination of sIgE
Wenqi SHAO ; Mi ZHOU ; Jing ZHU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Preventive Medicine 2025;59(9):1427-1433
To evaluate the analytical performance of a specific IgE (sIgE) quantitative detection system and explore the clinical application effect of dust mite extract and component detection. The fluorescent magnetic particle chemiluminescence method was used to verify the analytical performance of sIgE for house dust mite (D1), dust mite (D2) extracts, and their components (Der p 1, Der p 2, Der p 10, and Der p 23), including precision, limit of blank (LoB), limit of detection (LoD), linear range, and interfering factors. This is a retrospective cohort study. A total of 50 patients with allergic rhinitis and 50 patients with allergic asthma diagnosed at Zhongshan Hospital Affiliated to Fudan University from January 2022 to August 2023 were selected, along with 70 apparently healthy individuals who underwent physical examinations in the hospital as the healthy control group. The positive rates of each sIgE component in the three groups were compared, and the receiver operating characteristic (ROC) curve for diagnosing dust mite allergy was plotted. The results showed that the fluorescent magnetic particle chemiluminescence method for detecting sIgE demonstrated good repeatability and intermediate precision within the range of 0.1-100 kU/L. The LoB, LoD, and linear range all met the specified requirements. Except for Der p 10, which was interfered by the presence of conjugated bilirubin and free bilirubin (exceeding 40 mg/dl), the detection of other allergens was not significantly affected by common endogenous substances. In healthy individuals, 10% had positive sIgE for dustmite extract; in asthmatic and allergic rhinitis patients, the positive rates were 70% and 82%, respectively. The double positive rate of D1 and D2 in the healthy group was 8.6%, while in asthmatic and allergic rhinitis patients, it was 66% and 70%, respectively. When 0.35 kU/L was used as the threshold, the sensitivity of sIgE for dust mite extract to predict component positivity was 100%, specificity was 61.5%, positive predictive value (PPV) was 80.2%, and negative predictive value (NPV) was 100%. When the threshold was optimized to 0.78 kU/L, the sensitivity was 96.8%, specificity was 92.1%, PPV was 95.2%, and NPV was 94.6%. In conclusion, the repeatability, intermediate precision, LoB, LoD, linear range, and anti-interference ability of the fluorescent magnetic particle chemiluminescence method for detecting sIgE meet the requirements of laboratory quality management. This ensures detection quality, meets clinical needs, and can be used for the auxiliary diagnosis of allergic diseases.
7.Establishment and optimization of an autoverification system for thyroid function reports
Junhua CUI ; Jing ZHU ; Wenqi SHAO ; Jing YANG ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(2):207-213
Objective:To establish and optimize an autoverification system for thyroid function test reports of 5 items using historical test data.Methods:Based on the docoment' Autoverification of Clinical Laboratory Quantitative Test Results′, CLSI AUTO 10-A and AUTO 15 guidelines, an autoverification system for thyroid function test reports of 5 items was established combining with manual verification experience. A total of 193 860 thyroid function test reports of 5 items in 2021 were collected for the assessment of the original system. Totally 210 097 thyroid function test reports of 5 items in 2022 and 299 198 reports in 2023 were collected for the optimization of the autoverification system. There were 160 666 thyroid function test reports of 5 items from the first half of 2024 for the manual and autoverification comparison after optimization.Results:The pass rate of the autoverification system based on original thyroid function report in 2021 was 69.56%(134 849/193 860). The optimized system utilizing historical data from 2022 and 2023 covered 21 pattern rules and established verification for different patterns including range rules, delta check rules, and review rules. Taking manual verification as the standard for the data from the first half of 2024, the sensitivity and specificity of the optimized system were 100% (499/499) and 81.57% (130 646/160 167), respectively, with a false-negative rate of 0. The concordance rate between autoverification and manual verification was 81.63% (131 145/160 666), and the pass rate was 81.32% (130 646/160 666).Conclusion:Establishing and optimizing the autoverification system for thyroid function tests of 5 items using historical test data, and formulating verification rules for different patterns can be applied to clinical practise, which not only ensures the accuracy of test reports but also improves work efficiency, allowing continuously optimized and perfected of the system.
8.Diagnostic performance of 0-2 h high-sensitivity troponin T cutoffs recommended by the guidelines for suspected non-ST-segment elevation myocardial infarction among different age-groups
Ailun ZHANG ; Guorong GU ; Jing ZHU ; Jing YANG ; Wenqi SHAO ; Baishen PAN ; Beili WANG ; Chenling YAO ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(5):582-589
Objective:To evaluate the diagnostic performance of the 0-2 h high-sensitivity cardiac troponin T (hs-cTnT) cutoff recommended by the guidelines for the rule-out and rule-in diagnosis of suspected non-ST-segment elevation myocardial infarction (NSTEMI) patients of different age groups.Methods:This is a retrospective cohort study. Clinical data of 4 050 suspected NSTEMI patients who visited the Chest Pain Center of Zhongshan Hospital affiliated with Fudan University from January 2020 to December 2021 were retrospectively analyzed. Patients who visited from January 2020 to April 2021 (2 650 patients) were included as derivation cohort, and those who visited from May to December 2021 (1 400 patients) were included as validation cohort. The diagnostic performance of the guideline-recommended hs-cTnT 0-2 h cutoff for the rule-out and rule-in of NSTEMI diagnosis was compared among subgroups of patients aged ≤60, >60-70, and >70 years in the derivation group. Rule-out sensitivity, negative predictive value, and rule-out proportion, rule-in specificity, positive predictive value, and rule-in proportion were assessed. Cutoffs were established for subgroups with relatively lower diagnostic performance and validated in the validation group. Major adverse cardiovascular events (MACE) within 30 days after patient visit were used as the outcome, and survival curves were plotted using Kaplan-Meier curves, log-rank tests were used to analyze the incidence of MACE.Results:The sensitivity for ruled-out NSTEMI using the guideline-recommended 0-2 h cutoff in the subgroups of patients aged ≤60, >60-70, and >70 years in the derivation group was 100%; the negative predictive value was 100%; the ruled-out rates were 47.6% (331/696), 45.9% (491/1 070), and 28.5% (252/884), respectively. The specificity for ruled-in NSTEMI was 88.3%, 90.9%, and 86.4%, respectively; the positive predictive values were 55.3%, 59.3%, and 58.2%, respectively; the ruled-in rates were 22.6% (157/696), 19.5% (209/1 070), and 27.0% (239/884), respectively. With a requirement of sensitivity and negative predictive value >99%, the ruled-out cutoff for the subgroup of patients aged >70 years in the derivation group was established as 0 h hs-cTnT <6 ng/L or 0 h hs-cTnT<22 ng/L and 0-2 h Δhs-cTnT <5 ng/L, which increased the ruled-out rate of the subgroup aged >70 years to 45.6% (403/884). In the validation group, 42.2% (196/465) patients could be ruled-out. The incidence of MACE within 30 days for ruled-out patients aged >70 years using the established cutoff was 0.Conclusion:The diagnostic performance for the ruled-out and ruled-in diagnosis using the guideline-recommended 0-2 h hs-cTnT cutoff are relatively consistent across different age groups, but the ruled-out rate for patients aged >70 years is lower than for those aged ≤60 and >60-70 years. The ruled-out cutoff established in this study can be used to improve diagnostic performance of thus indicator on suspected NSTEMI patients.
9.ApoB, ApoB/LDL-C, and non-HDL-C level changes at a hospital in Shanghai from 2014 to 2024: data analysis of a large sample with over 1.6 million cases
Jing ZHU ; Jiayi HUANG ; Ying XIONG ; Xincen DUAN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(7):851-860
Objective:To analyze the variation trends in the levels of apolipoprotein B (ApoB), the ratio of apolipoprotein B to low-density lipoprotein cholesterol (ApoB/LDL-C), and non-high density lipoprotein cholesterol (non-HDL-C) among patients and individuals undergoing physical examinations at Zhongshan Hospital, Fudan University from 2014 to 2024.Methods:Data on ApoB, LDL-C, and nonHDL-C levels were collected from individuals (the overall population) who visited or underwent physical examinations at our hospital from January 1, 2014 to December 31, 2024, as well as from individuals (the fixed population) who were tested annually over the 11-year period. The Mann-Kendall test combined with Sen slope estimation was used to analyze the trends. The abnormal rates of ApoB and non-HDL-C in both the overall and fixed populations, as well as the changes in the first and last test results over the 11 years in the fixed population, were also analyzed.Results:The overall population totaled 1 679 440 cases, aged 57 (45, 67) years, and 718 738 cases (42.8%) were female, of which 1 250 234 cases (74.4%) were in the patient population and 429 206 cases (25.6%) were in the health check population. The fixed population of 1 560 cases was 56 (45, 65) years old and 655 cases (42.0%) were female, of which 1 044 cases (66.9%) were in the patient population and 516 cases (33.1%) in the health check population. Between 2014 and 2024, the overall population ApoB decreased from 0.842 g/L to 0.822 g/L (Sen slope -0.001 g·L -1·year -1, P=0.01), the abnormality rate decreased from 24.70% to 22.03% (Sen slope -0.50%/year, P=0.06), and 69.4% of the fixed population showed no change in the subgroups of initial and final tests. ApoB/LDL-C increased from 0.824 to 0.868 (Sen slope -0.003/year, P=0.72). Non-HDL-C decreased from 3.46 mmol/L to 3.32 mmol/L (Sen slope 0.018 mmol·L -1·year -1, P=0.35), with a statistically significant upward trend since 2019 (Sen slope 0.037 mmol·L -1·year -1, P=0.008), and the anomaly rate decreased from 24.3% to 22.7% (Sen slope 0.55%/year, P=0.64), with a statistically significant upward trend since 2019 (Sen slope 1.53%/year, P=0.014), and no change in the grouping of the first and last tests in 75.0% of the fixed population. The trends in the above items were consistent between the overall population and the fixed population. 20-<40 year olds had the most significant upward trend in non-HDL-C along with the least significant downward trend in ApoB/LDL-C and ApoB. Conclusion:ApoB in the overall and fixed populations from 2014-2024 in a Shanghai hospital showed a decreasing trend, and non-HDL-C and abnormality rates showed an increasing trend from 2019 onwards.
10.Analysis of lipid data from 2014 to 2024 based on over 2.6 million cases from a hospital in Shanghai
Jingrong XIAN ; Jing ZHU ; Ying XIONG ; Xincen DUAN ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2025;48(7):842-850
Objective:To analyze the trend of lipid changes in patients and individuals undergoing physical examination at Zhongshan Hospital of Fudan University from 2014 to 2024, providing evidence for the formulation of cardiovascular disease prevention and control strategies.Methods:A total of 2 657 835 individuals (general population) who underwent lipid testing during medical visits or physical examinations at Zhongshan Hospital of Fudan University from January 1, 2014, to December 31, 2024, were selected. Among them, 6 234 individuals who were tested consecutively for 11 years were considered as the fixed population. Lipid levels were analyzed across different genders and age groups. Total cholesterol (TC), triglycerides (TG), low-density lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol (HDL-C) were analyzed. The trends in lipid changes and the abnormal rates of TC (≥5.18 mmol/L) and LDL-C (≥3.40 mmol/L) in both the general and fixed populations were statistically analyzed.Results:The median age of the general population was 53 (41, 63) years, with 1 498 533 males (56.4%); 1 149 662 individuals (43.3%) were from the physical examination group. The median age of the fixed population was 52 (39, 62) years, with 3 262 males (52.3%); 2 955 individuals (47.4%) were from the physical examination group. Over an 11-year period, the logarithmically transformed TG (lnTG) in the general population slightly increased from 1.35 mmol/L to 1.36 mmol/L (Sen slope=0.007 mmol·L -1·year -1; S=27, P=0.043). Although there were fluctuations in TC, LDL-C, and HDL-C, the trends were not statistically significant ( P>0.05). However, in the subset of the population undergoing regular health check-ups, TC showed a steady increase over time ( S=27, P=0.043). Within a fixed population over the same 11-year period, there were no statistically significant changes in lipid profiles ( P>0.05). Nevertheless, in the fixed subset undergoing regular health check-ups, both TC and lnTG exhibited an upward trend (TC: S=27, P=0.043; lnTG: S=31, P=0.020), while in the fixed subset seeking medical attention, TC and LDL-C demonstrated a downward trend (TC: S=-31, P=0.020; LDL-C: S=-27, P=0.043). Trends in lipid profiles varied among different genders and age groups. Specifically, both men and women aged 20-<40 years old showed an increase in TC, abnormal TC rates, and abnormal LDL-C rates ( P<0.05). Conversely, in the fixed population, women over 60 years old exhibited a decrease in TC, abnormal TC rates, and abnormal LDL-C rates ( P<0.05). Conclusion:During the period from 2014 to 2024, there were slight fluctuations in the average lipid levels of both the general and fixed populations. Notably, TC, abnormal TC rates, and abnormal LDL-C rates increased among men and women aged 20-<40 years old, while these parameters decreased among women over 60 years old in the fixed population.