1.Predictive factors and prognostic value of textbook outcomes after radical resection for intrahepatic cholangiocarcinoma
Biyuan ZHANG ; Weixuan XIE ; Yang BAI ; Zheng FANG ; Kunlun LUO ; Xue MEI ; Haiting XU ; Zhihua ZHOU ; Qingzhou ZHU
Chinese Journal of General Surgery 2025;34(8):1688-1695
Background and Aims:Radical resection is the only potentially curative treatment for intrahepatic cholangiocarcinoma(ICC),yet the high recurrence rate results in poor prognosis.In recent years,"textbook outcome"(TO)has been proposed as a comprehensive quality metric,but its association with prognosis remains unclear.This study aimed to analyze the risk factors influencing the achievement of TO after radical resection of ICC and to explore the relationship between TO and survival.Methods:A retrospective analysis was conducted on the clinical data of 180 ICC patients who underwent radical resection at the 904th Hospital of the Joint Logistic Support Force of the PLA between February 2018 and February 2023.Univariate and multivariate Logistic regression analyses were performed to identify risk factors associated with TO,and survival analysis was carried out using the Kaplan-Meier method and Log-rank test.Results:Of the 180 patients,66 achieved TO.Multivariate Logistic regression analysis indicated that preoperative total bilirubin>22 μmol/L,preoperative CA19-9>35 U/mL,maximum tumor diameter>5 cm,poor tumor differentiation,microvascular invasion(MVI),and lymph node metastasis were independent risk factors for failing to achieve TO(all P<0.05).Survival analysis demonstrated that patients who achieved TO had a significantly longer median survival compared with those who did not(36 months vs.16 months,P<0.001).Conclusion:Preoperative total bilirubin>22 μmol/L,preoperative CA19-9>35 U/mL,maximum tumor diameter>5 cm,poor tumor differentiation,MVI,and lymph node metastasis are independent risk factors for not achieving TO after radical resection of ICC.Patients who achieved TO exhibited markedly longer survival,suggesting that TO not only reflects perioperative treatment quality but also serves as an important prognostic indicator.Greater attention to these risk factors and optimization of perioperative management may improve the likelihood of achieving TO and enhance long-term outcomes.
2.Predictive factors and prognostic value of textbook outcomes after radical resection for intrahepatic cholangiocarcinoma
Biyuan ZHANG ; Weixuan XIE ; Yang BAI ; Zheng FANG ; Kunlun LUO ; Xue MEI ; Haiting XU ; Zhihua ZHOU ; Qingzhou ZHU
Chinese Journal of General Surgery 2025;34(8):1688-1695
Background and Aims:Radical resection is the only potentially curative treatment for intrahepatic cholangiocarcinoma(ICC),yet the high recurrence rate results in poor prognosis.In recent years,"textbook outcome"(TO)has been proposed as a comprehensive quality metric,but its association with prognosis remains unclear.This study aimed to analyze the risk factors influencing the achievement of TO after radical resection of ICC and to explore the relationship between TO and survival.Methods:A retrospective analysis was conducted on the clinical data of 180 ICC patients who underwent radical resection at the 904th Hospital of the Joint Logistic Support Force of the PLA between February 2018 and February 2023.Univariate and multivariate Logistic regression analyses were performed to identify risk factors associated with TO,and survival analysis was carried out using the Kaplan-Meier method and Log-rank test.Results:Of the 180 patients,66 achieved TO.Multivariate Logistic regression analysis indicated that preoperative total bilirubin>22 μmol/L,preoperative CA19-9>35 U/mL,maximum tumor diameter>5 cm,poor tumor differentiation,microvascular invasion(MVI),and lymph node metastasis were independent risk factors for failing to achieve TO(all P<0.05).Survival analysis demonstrated that patients who achieved TO had a significantly longer median survival compared with those who did not(36 months vs.16 months,P<0.001).Conclusion:Preoperative total bilirubin>22 μmol/L,preoperative CA19-9>35 U/mL,maximum tumor diameter>5 cm,poor tumor differentiation,MVI,and lymph node metastasis are independent risk factors for not achieving TO after radical resection of ICC.Patients who achieved TO exhibited markedly longer survival,suggesting that TO not only reflects perioperative treatment quality but also serves as an important prognostic indicator.Greater attention to these risk factors and optimization of perioperative management may improve the likelihood of achieving TO and enhance long-term outcomes.
3.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.
4.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.
5.Investigation and analysis of energy release of cardiac defibrillator at different stages of lifecycle of that
Dong LI ; Xiaolong WANG ; Feng XIE ; Yukun WANG ; Yuan LIU ; Xiaohong LI ; Mei BAI
China Medical Equipment 2024;21(3):39-43
Objective:To analyze the performance characteristics of the energy output of defibrillation device at different lifecycle stages of the equipment,and to improve the level of management,so as to ensure the safety and effectiveness of using the device.Methods:A total of 90 defibrillation devices of using 10 types included 861290 and CardioServ(included scrapped devices)during the period of 2015-2022 were retrospectively analyzed.The detected data of energy output of defibrillation device were analyzed as statistical method,and the error of releasing energy was calculated.A total of 36 defibrillation devices that were in the early stages of use(at the first three years of device use)were divided into the first year,the second year and the third year,and the data of energy outputs of devices among three years were compared.The data of the type A and type B defibrillation devices,which were the largest number of devices in the normal stage of use(the middle stage of use),were calibrated according to the energy release in the three years between 2018 and 2000.The difference of releasing energy at the preseted value of 100J between the two types of devices was analyzed.Finally,the errors of energy releases of 8 devices,which energy outputs exceeded the deadline,in the scrap period between 2015 and 2022 were summarized.Results:In the data of three groups of devices in the early stages of use,the differences at the first and second year of device use among 100J,150J and 200J of the energy releases of the preseted values were significant(t=-0.17,-0.17,-0.58,P>0.05).The difference of the measured values between the first and third years of device use was not significant(Z=-0.70,-0.38,-0.86,P>0.05).The results of variance analysis of repeated measurement of the energy releases of the devices in normal stage indicated that the difference of the energy release at 100J preseted point among different types of 41 devices was significant(F=4.40,P<0.05).The energy release of type X defibrillator appeared constantly high,and the relative error increased with the increasing of preseted values.The repeatability of the device was better,and the relationship between preseted energy(x)and release energy(y)conformed to linear relationship(R2=0.9985).In these defibrillation devices that were using,the qualified rate of energy output of>100J preseted point was 97.68%.Conclusion:There is slight difference in the mean value of energy release between different type of defibrillation devices within the qualified range,and the energy release still is a performance indicator that should be highly focused for defibrillation devices.We should combine with the maintenance and repair data of device to conduct in-depth analysis,so as to grasp the operating status of the device,and optimize the strategy of quality control,and ensure the safety of defibrillator in clinical use.
6.Analyzing the clinical characteristics of 56 cases of occupational pneumoconiosis complicated with interstitial lung disease
Mei BAI ; Jiuhong ZHANG ; Zhiqiang CHEN ; Weiming XIE
China Occupational Medicine 2024;51(4):415-418
Objective To explore the clinical features of occupational pneumoconiosis (hereinafter referred to as “pneumoconiosis”) complicated with interstitial lung disease (ILD). Methods A total of 56 patients with pneumoconiosis complicated with ILD were selected as the research subjects using a retrospective study method, and their clinical features were analyzed. Results The main clinical symptoms of the 56 patients were progressive dyspnea, cough, and expectoration, with detection rates of 76.8%, 75.0%, and 55.4%, respectively. The detection rates of hypoxemia and respiratory failure were 67.9% and 32.1% respectively. Among the 35 patients who underwent pulmonary function test, restrictive, mixed, and obstructive ventilatory disorders were detected in 37.1%, 22.9%, and 17.1% of cases, respectively, with a 74.3% detection rate for reduced diffusion capacity. High resolution computed tomography of the chest revealed ground-glass shadows, grid shadow, interlobular thickening, honeycomb shadows and tractive bronchiectasis, with detection rates of 57.1%, 35.7%, 35.7%, 23.2%, and 17.9%, respectively. Lesions were mostly diffusely distributed in both lungs, with a predominance in the lower lungs compared to the mid-upper lungs. Patients complicated with connective tissue disease, including systemic sclerosis, rheumatoid arthritis, systemic lupus erythematosus, polymyositis, and dermatomyositis, accounted for 33.9% (19 cases). Conclusion The clinical symptoms, pulmonary function, and arterial blood gas analysis results of patients with pneumoconiosis complicated with ILD show no specific features. However, a subset of pneumoconiosis patients with ILD also have coexisting connective tissue diseases.
7.Exploration of making removable partial denture by digital technology.
Zhi Hong FENG ; Sheng ZHONG ; Xuan ZHANG ; Hui DONG ; Yue FENG ; Rui XIE ; Shi Zhu BAI ; Xiao Mei FANG ; Peng ZHU ; Min YAN ; Yi Min ZHAO
Chinese Journal of Stomatology 2023;58(4):354-358
To explore the digital manufacturing process of distal extension removable partial denture. From November 2021 to December 2022, 12 patients (7 males and 5 females) with free-ending situation were selected from the Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University. Three-dimensional model of the relationship between alveolar ridge and jaw position was obtained by intraoral scanning technique. After routine design, manufacturing and try-in of metal framework for removable partial denture, the metal framework was located in the mouth and scanned again to obtain the composite model of dentition, alveolar ridge and metal framework. The free-end modified model is obtained by merging the digital model of free-end alveolar ridge with the virtual model with the metal framework. The three-dimensional model of artificial dentition, and base plate was designed on the free-end modified model, and the resin model were made by digital milling technology. The removable partial denture was made by accurately positioning the artificial dentition and base plate, bonding metal framework with injection resin, grinding and polishing the artificial dentition and resin base. Compared with the design data after clinical trial, the results showed that there was an error of 0.4-1.0 mm and an error of 0.03-0.10 mm in the connection between the resin base of artificial dentition and the connecting rod of the in-place bolt and the connection between artificial dentition and resin base. After denturen delivery, only 2 patients needed grinding adjustment in follow-up visit due to tenderness, and the rest patients did not find any discomfort. The digital fabrication process of removable partial denture used in this study can basically solve the problems of digital fabrication of free-end modified model and assembly of artificial dentition with resin base and metal framework.
8.Preliminary exploration on operation process for autologous ozonized blood transfusion
Jianjun WU ; Yan BAI ; Yanli BAI ; Zhanshan ZHA ; Jing CHEN ; Yahan FAN ; Jiwu GONG ; Shouyong HUN ; Hongbing LI ; Zhongjun LI ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Jiubo LIU ; Jingling LUO ; Xianjun MA ; Deying MENG ; Shijie MU ; Mei QIN ; Hui WANG ; Haiyan WANG ; Qiushi WANG ; Quanli WANG ; Xiaoning WANG ; Yongjun WANG ; Changsong WU ; Lin WU ; Jue XIE ; Pu XU ; Liying XU ; Mingchia YANG ; Yongtao YANG ; Yang YU ; Zebo YU ; Juan ZHANG ; Xiaoyu ZHOU ; Xuelian ZHOU ; Shuming ZHAO
Chinese Journal of Blood Transfusion 2023;36(2):95-100
Autologous ozonized blood transfusion(AOBT) is a therapy of re-transfusion of 100-200 mL of autologous blood after shaking and agitation with appropriate amount of oxygen-ozone in vitro. The oxidation of blood through the strong oxidation of ozone can enhance the non-specific immune response of the body, regulate the internal environment and promote health. This therapy has been increasingly applied in clinical practice, while no unified standard for the operation process in terms of ozone concentration, treatment frequency and treatment course had been established. This operation process of AOBT is primarily explored in order to standardize the operation process and ensure its safety and efficacy.
9.Material Attribute Research in Quality Control of Traditional Chinese Medicine Pills: A Review
Shu-ting ZHAO ; Bai-xue YANG ; Jia-rong XIE ; Hao-shu XIONG ; Yu-xia SUN ; Yan-mei LI ; Shun-nan ZHANG ; Wen-yuan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2022;28(3):259-265
As intelligent production of traditional Chinese medicine (TCM) has been inevitable, informatization and automation of the production process have become the precondition for realizing intelligent manufacturing of TCM, of which the accumulation of critical material attribute and the critical quality attribute are the basis. The study of material properties is of great significance to achieve the quality control of the final product in the process, but there is a lack of systematic induction and summary of the research on the attribute of TCM pills. Therefore, the authors analyzed and summarized the attributes of raw materials, excipients and intermediates in the pill unit process according to the classification of powder properties, rheological properties and texture properties. What’s more, the impact of material attributes on the quality of the final product was summarized. Besides, this review summarized the attribute characterization techniques involved in the pill process and provided some suggestions for the characterization of product quality attributes. Finally, based on the concept of quality by design (QbD), the authors proposed that the study of material attribute should be combined with process analytical technology (PAT), and the focus of drug quality control should be moved forward to guide equipment upgrading, so as to realize intelligent continuous manufacturing of TCM pills.
10.Semen parameters in men recovered from COVID-19.
Tong-Hang GUO ; Mei-Ying SANG ; Shun BAI ; Hui MA ; Yang-Yang WAN ; Xiao-Hua JIANG ; Yuan-Wei ZHANG ; Bo XU ; Hong CHEN ; Xue-Ying ZHENG ; Si-Hui LUO ; Xue-Feng XIE ; Chen-Jia GONG ; Jian-Ping WENG ; Qing-Hua SHI
Asian Journal of Andrology 2021;23(5):479-483
The novel coronavirus disease (COVID-19) pandemic is emerging as a global health threat and shows a higher risk for men than women. Thus far, the studies on andrological consequences of COVID-19 are limited. To ascertain the consequences of COVID-19 on sperm parameters after recovery, we recruited 41 reproductive-aged male patients who had recovered from COVID-19, and analyzed their semen parameters and serum sex hormones at a median time of 56 days after hospital discharge. For longitudinal analysis, a second sampling was obtained from 22 of the 41 patients after a median time interval of 29 days from first sampling. Compared with controls who had not suffered from COVID-19, the total sperm count, sperm concentration, and percentages of motile and progressively motile spermatozoa in the patients were significantly lower at first sampling, while sperm vitality and morphology were not affected. The total sperm count, sperm concentration, and number of motile spermatozoa per ejaculate were significantly increased and the percentage of morphologically abnormal sperm was reduced at the second sampling compared with those at first in the 22 patients examined. Though there were higher prolactin and lower progesterone levels in patients at first sampling than those in controls, no significant alterations were detected for any sex hormones examined over time following COVID-19 recovery in the 22 patients. Although it should be interpreted carefully, these findings indicate an adverse but potentially reversible consequence of COVID-19 on sperm quality.
Adult
;
Asthenozoospermia/virology*
;
COVID-19/physiopathology*
;
China
;
Gonadal Steroid Hormones/blood*
;
Humans
;
Male
;
Progesterone/blood*
;
Prolactin/blood*
;
SARS-CoV-2
;
Semen/physiology*
;
Semen Analysis
;
Sperm Count
;
Sperm Motility
;
Spermatozoa/physiology*
;
Time Factors

Result Analysis
Print
Save
E-mail