1.Development and Validation of a Lectin-independent Liquid Chromatography–Tandem Mass Spectrometry Method for Serum Glycosylated Alpha-fetoprotein Analysis and Comparison with a Liquid-phase Binding Assay
Hyojin KIM ; Juri PARK ; Hanseul SUH ; Saeyoung LEE ; Yoonha PARK ; Won Suk YANG ; Dohsik MINN ; Soon Sun KIM ; Jae Youn CHEONG ; Je-Hyun BAEK
Annals of Laboratory Medicine 2026;46(1):62-71
Background:
Alpha-fetoprotein (AFP) and its isoform AFP-L3 are well-established serum biomarkers for hepatocellular carcinoma (HCC), a common malignancy and a leading cause of cancer-related mortality worldwide. Current methods for measuring these biomarkers are primarily lectin-based assays including the liquid-phase binding assay (LiBA) and liquid chromatography–tandem mass spectrometry (LC-MS/MS), both of which have limitations in diagnostic sensitivity and clinical utility for samples with low AFP concentrations. We aimed to develop a lectin-independent LC-MS/MS method for quantifying fucosylated AFP proteins (AFP-Fuc%).
Methods:
We conducted analytical validation, including method comparisons, over 2 months. The analytical sensitivity and diagnostic performance of this method were evaluated using 525 human serum samples—235 from HCC patients and 290 from non-HCC individuals—and compared with those of LiBA, which measured AFP-L3 levels.
Results:
The LC-MS/MS method demonstrated acceptable within-laboratory imprecision (CVs < 17.1%) without detectable bias, carryover, or matrix effects. Our method exhibited a broader linear dynamic range (spanning five orders of magnitude) and 10-fold higher analytical sensitivity than LiBA. The diagnostic performance of our method was significantly superior to that of LiBA, particularly in patients with low AFP concentrations ( < 7 ng/mL, P < 0.001), with improved accuracy, sensitivity, and precision at a specificity of 96.2%.
Conclusions
The validated LC-MS/MS method demonstrated robust analytical performance and superior diagnostic accuracy over LiBA for HCC diagnosis while avoiding the inherent limitations of lectin-based assays. Our LC-MS/MS assay shows promise for early HCC detection and may contribute to enhanced patient care.
2.Development and evaluation of the Trauma-nursing Education and Skill Support program to enhance trauma nursing competencies: a quasi-experimental study
Tae Yeong YANG ; Myung Jin JANG ; Ki Ung KIM ; Min SO ; Mi Na CHOI ; Eun Jung LEE ; Jin Su JO ; Ji Yun LEE ; Kwang Kyun LIM ; Kyoung Mi KIM ; Hae Jun BAEK ; Sun Ho WANG ; Jin Oh CHOI
Journal of Korean Academy of Nursing 2026;56(1):67-80
Purpose:
This study aimed to develop and evaluate the effectiveness of the Trauma-nursing Education and Skill Support (TESS) program based on the ADDIE model (Analysis, Design, Development, Implementation, Evaluation model). The program was designed to enhance trauma nurses’ clinical competencies, including trauma-related knowledge, self-efficacy, and problem-solving ability, through the integration of theoretical education and simulation-based practice.
Methods:
A quasi-experimental study using a non-equivalent control group pretest–posttest design was conducted. Participants included 108 trauma nurses from regional trauma centers, military trauma centers, and emergency care facilities, who were assigned to an experimental group (n=52) or a control group (n=56). The TESS program consisted of a 2-day, 14-hour blended-learning course that included eight lecture sessions and four simulation-based practice stations. Data were collected at baseline, immediately after the intervention, and at 6 months using validated instruments measuring trauma-related knowledge, self-efficacy, and problem-solving ability. Two-way repeated-measures analysis of variance was used for data analysis.
Results:
The experimental group demonstrated significant improvements in trauma-related knowledge, self-efficacy, and problem-solving ability compared with baseline (all p<.001). These improvements were sustained at 6 months, although trauma-related knowledge scores showed a slight decline compared with immediate posttest levels. Between-group analyses confirmed significant group-by-time interaction effects for all outcomes: trauma-related knowledge (η2=0.12, p<.001), self-efficacy (η2=0.09, p=.002), and problem-solving ability (η2=0.08, p=.003).
Conclusion
The TESS program effectively enhanced trauma nurses’ trauma-related knowledge, self-efficacy, and problem-solving ability, with effects sustained for up to 6 months. Incorporating blended learning and simulation-based training into standardized trauma nursing education may strengthen clinical competencies and ultimately contribute to improved patient outcomes.
3.Myopia Management Consensus Statement in South Korean Children 2025 by the Korean Myopia Society for the Korean Association for Pediatric Ophthalmology and Strabismus
Yeon-Hee LEE ; Jae Yun SUNG ; Sun Young SHIN ; Young-Woo SUH ; Ungsoo Samuel KIM ; Hyunkyung KIM ; Kyung-Ah PARK ; Su Jin KIM ; MiRae KIM ; Hyun Jin SHIN ; Kyeong Wook LEE ; Haeng-Jin LEE ; So Young HAN ; Jinu HAN ; Eun Hee HONG ; Seung-Hee Hannah BAEK ; Hae Jung PAIK ;
Korean Journal of Ophthalmology 2026;40(2):185-205
Myopia, particularly high myopia, is a significant risk factor for several ocular pathologies including cataract, glaucoma, and retinal detachment. Excessive axial elongation associated with high myopia can induce biomechanical stretching, increasing the risk of serious complications like posterior staphyloma and myopic maculopathy. Global meta-analyses estimate that approximately 10 million people were visually impaired due to myopic maculopathy in 2015, with 3 million being blind. Recent nationwide surveys in South Korea revealed a prevalence of 65.4% for myopia and 6.9% for high myopia in children and adolescents, highlighting the urgent need for effective management. Delaying the onset and slowing the progression of myopia during childhood and adolescence is crucial for reducing the potential lifetime risk of these complications. This consensus statement, prepared by the Korean Myopia Society for the Korean Association for Pediatric Ophthalmology and Strabismus (KAPOS), reviews the current evidence for myopia control interventions and provides management strategies applicable to the South Korean clinical setting. Key interventions covered include lifestyle modifications (outdoor time, near work adjustment), optical methods (myopia-control spectacle lenses, dual-focus soft contact lenses, orthokeratology), and pharmacologic treatment (low-concentration atropine), as well as combination therapies. The statement also addresses patient selection, treatment outcome evaluation using spherical equivalent and axial length changes, and the crucial aspects related to treatment cessation and the rebound effect.
4.Association of Breast Tissue Composition on Preoperative Automated Breast Ultrasound With Accuracy of Cancer Multiplicity Evaluation and Recurrence-Free Survival in Patients With Early-Stage Breast Cancer
Myoung Kyoung KIM ; Haejung KIM ; Sun-Young BAEK ; Eun Young KO ; Boo-Kyung HAN ; Eun Sook KO ; Jeongmin LEE ; Nami CHOI ; Jin CHUNG ; Ji Soo CHOI
Korean Journal of Radiology 2026;27(2):97-110
Objective:
To investigate whether breast tissue composition on preoperative automated breast ultrasound (ABUS) is associated with the accuracy of cancer multiplicity evaluation and postoperative recurrence-free survival (RFS) in patients with early-stage breast cancer.
Materials and Methods:
This retrospective analysis included women with early-stage breast cancer (clinical Tis, T1–2/N0) who underwent ABUS and digital mammography (DM) between October 2019 and April 2021. Tissue composition on ABUS was assessed using the Breast Imaging Reporting and Data System background echotexture (BE) (homogeneous-fat, homogeneous-fibroglandular, or heterogeneous). In a subgroup of patients with mammographically dense breasts, the glandular tissue component (GTC) on ABUS were further stratified into high (moderate or marked) or low (minimal or mild).Multivariable logistic and Cox regression analyses were used to identify factors associated with accurate cancer multiplicity categorization (unifocal, multifocal/multicentric, or bilateral) using ABUS + DM, and with RFS, respectively.
Results:
Among 409 women (mean age ± standard deviation, 50.2 ± 8.7 years), ABUS combined with DM yielded accurate cancer multiplicity categorization in 368 patients (90.0%). Neither BE nor GTC on ABUS affected the accuracy of categorization when ABUS was combined with DM. Over a median postoperative follow-up of 3.5 years, 11 recurrences occurred. Heterogeneous BE on ABUS (hazard ratio [HR] 11.24 [95% confidence interval [CI]: 2.82–44.92]; P = 0.001), BRCA mutation (HR 15.94 [2.47–102.97]; P = 0.004), and pathologic index cancer size (HR per 1-cm increase 1.91 [1.13–3.23];P = 0.02) was independently associated with RFS. In patients with dense breasts, heterogeneous BE (HR 14.17 [95% CI:2.69–74.60]; P = 0.002) and high GTC (HR 10.32 [2.35–45.28]; P = 0.002) on ABUS, BRCA mutation (HR 24.34 [2.75– 215.06]; P = 0.004), and pathologic cancer size (HR per 1-cm increase 2.62 [1.50–4.59]; P = 0.001) was independently associated with RFS.
Conclusion
In patients with early-stage breast cancer, heterogeneous BE and high GTC on preoperative ABUS, along with larger cancer size and BRCA mutation, was associated with worse RFS. However, BE and GTC did not affect cancer multiplicity evaluation when ABUS was used in combination with DM.
5.Prognostic value of carcinoembryonic antigen kinetics in predicting distant metastatic recurrence of breast cancer:a multicenter cohort study
Bong Kyun KIM ; Dooreh KIM ; Jong Min BAEK ; Yong Hwa EOM ; Young-Joon KANG ; Jiyoung RHU ; Juneyoung AHN ; Ye Won JEON ; Woo Young SUN
Annals of Surgical Treatment and Research 2026;110(5):299-310
Purpose:
Distant metastasis of breast cancer significantly affects the prognosis. Serum markers such as CEA and cancer antigen (CA) 15-3 are used for surveillance. However, the nonspecificity and nonmalignant elevation of CEA limit its absolute value in predicting metastatic recurrence. We reevaluated the clinical value of CEA kinetics in predicting metastatic recurrence in breast cancer.
Methods:
In this multicenter retrospective cohort study, we utilized electronic medical record data from eight institutions (2008–2023), including 4,872 surgically treated patients with invasive breast cancer. Novel CEA kinetic indices were defined.Predictive capabilities were assessed using logistic regression, Kaplan-Meier survival curves, and Cox proportional hazards models.
Results:
CEA velocity (vCEA) and last-interval vCEA (vCEA-L) showed higher accuracy and sensitivity in predicting distant metastasis than absolute CEA indices. All tumor marker indices were independent predictors; vCEA, vCEA-L, and maximum vCEA (vCEAmax) showed the highest association. In the 5-year distant disease-free survival analysis of patients, vCEA showed the most significant difference based on whether its cutoff value was exceeded (84.1% vs. 47.2%) (P < 0.001).Cox analysis showed that vCEA was the strongest predictor (hazard ratio, 4.509; P < 0.001). vCEAmax remained prognostic even when CEAmax was below its cutoff value.
Conclusion
Analysis of dynamic CEA changes, particularly velocity-based indices, offers superior predictive power than the static-based CEA indices for metastatic recurrence in breast cancer. These kinetic markers enhance prognostic accuracy when combined with CA 15-3. Future research should integrate these markers with imaging, liquid biopsy, and artificial intelligence for personalized follow-up.
6.Structured Integration of an Artificial Intelligence-Based System for the Optical Diagnosis of Colorectal Polyps
Hae Yeon KANG ; Soonwhan KANG ; Goh Eun CHUNG ; Dong Hoon BAEK ; Hong Sub LEE ; Jinbae PARK ; Sun Young YANG ; Seon Hee LIM ; Ji Min CHOI ; Jung KIM ; Jung Ho BAE
Gut and Liver 2026;20(1):86-96
Background/Aims:
Recent advances in computer-aided diagnosis (CADx) systems have demonstrated expert-level accuracy in the optical diagnosis of colorectal polyps. High-confidence (HC) diagnoses have been defined as those made within 3 seconds without hesitation, and these systems have been shown to improve diagnostic accuracy. We aimed to evaluate the performance of endoscopists with varying levels of experience in diagnosing colorectal polyps with the assistance of a new CADx system applying the 3-second rule and without artificial intelligence assistance.
Methods:
In this multicenter ex vivo study, 35 endoscopists assessed 100 polyps (51 adenomas, 39 hyperplastic polyps, 10 sessile serrated lesions) using narrow-band imaging video clips on an online platform. Assessments consisted of individual endoscopist diagnosis and CADx-assisted diagnosis. HC assignments followed the 3-second rule in both phases. Performance metrics included HC accuracy, HC rate, and adherence to the Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) and Simple Optical Diagnosis Accuracy (SODA) thresholds.
Results:
HC diagnostic accuracy improved from 78.3% (95% confidence interval [CI], 76.6% to 80.0%) to 89.8% (95% CI, 88.6% to 90.9%) with CADx assistance (p<0.001). The proportion of HC predictions increased from 64.2% to 75.4% (p<0.001). Novice endoscopists showed marked improvement with CADx (74.1% vs 88.8%; p<0.001). CADx-assisted diagnoses nearly met SODA and PIVI thresholds under the 3-second rule. Additional analysis demonstrated that CADx assistance significantly improved interobserver agreement and ground truth, particularly for novices (κ=0.37 to κ=0.65; p<0.001).
Conclusions
Integrating CADx with the 3-second rule significantly enhances the performance of endoscopists in the optical diagnosis of colorectal polyps, with the greatest benefit observed among novice endoscopists.
7.Low-frequency auricular vagus nerve stimulation facilitates cerebrospinal fluid influx by promoting vasomotion
Seunghwan CHOI ; In Seon BAEK ; Kyungjoon LEE ; Sun Kwang KIM
The Korean Journal of Physiology and Pharmacology 2025;29(1):109-116
Auricular vagus nerve stimulation (aVNS) is one of the promising neuromodulation techniques due to its non-invasiveness, convenience, and effectiveness. aVNS has been suggested as a potential treatment for neurodegenerative diseases showing impaired cerebrospinal fluid (CSF) dynamics. Improving CSF flow has been proposed as a key mechanism of the therapeutic effect on neurodegenerative diseases. However, aVNS parameters have been set empirically and the effective parameter that maximize the effect remains elusive. Here we show that 30 minutes of low-frequency aVNS increased arterial vasomotion events and enhanced cortical CSF influx along the branches of middle cerebral arteries. By using in vivo two photon imaging or widefield fluorescence microscopy with plasma and CSF tracers for visualizing blood vessels and perivascular spaces, arterial vasomotion and cortical CSF influx dynamics were acquired. The low-frequency (2 Hz) aVNS, but not middleand high-frequency (40 and 100 Hz) aVNS, significantly increased the number of vasomotion events compared to the sham group. Accordingly, in the CSF imaging, 2 Hz of aVNS markedly enhanced the CSF influx. Our findings demonstrate that lowfrequency aVNS is the effective parameter in respect to modulating vasomotion and CSF influx, resulting in brain clearance effect.
8.Posterior subependymal germinal matrix hemorrhage as a mild form of hemorrhage in extremely preterm infants: neurodevelopmental outcomes at corrected ages of 18-24 months
Jae Mo KOO ; So-Young YOO ; Ji Hye KIM ; Ji Eun PARK ; Sun-Young BAEK ; Tae Yeon JEON
Ultrasonography 2025;44(1):48-61
Purpose:
This study aimed to explore the effects of both the presence and size of posterior subependymal germinal matrix hemorrhage (PS-GMH), considered a mild form of hemorrhage, on the neurodevelopmental outcomes of extremely preterm infants.
Methods:
A retrospective analysis was conducted on 221 extremely preterm infants, assessing their initial and term-equivalent age (TEA) cranial ultrasound (cUS) examinations from 2016 to 2021. Infants were classified based on the presence and size (small/large) of PS-GMH. Neurodevelopmental outcomes at corrected ages of 18-24 months were analyzed in 135 infants.
Results:
PS-GMH was identified in 86.9% (192/221) of the infants, with 13.5% (26/192) exhibiting large PS-GMH. Among the 135 infants who were followed up, those with PS-GMH were found to have younger gestational ages (P<0.001) and a higher incidence of maternal chorioamnionitis (P=0.016) than those without PS-GMH. Significant differences were observed in the incidence of grade II intraventricular hemorrhage (IVH) on initial cUS (P=0.003) and ventriculomegaly at TEA cUS (P=0.026) across the groups with no PS-GMH, small PS-GMH, and large PS-GMH. The large PS-GMH group exhibited a higher occurrence of grade II IVH than the small PS-GMH group (P=0.006). However, ventriculomegaly incidence did not significantly vary with PS-GMH status. Neurodevelopmental outcomes were also not significantly different across PS-GMH statuses. The adjusted odds ratios for any neurodevelopmental impairment, compared to the no PS-GMH group, were 1.70 (95% confidence interval [CI], 0.40 to 7.26; P=0.471) for all PS-GMH, 1.61 (95% CI, 0.37 to 6.93; P=0.526) for small PS-GMH, and 3.84 (95% CI, 0.62 to 24.00; P=0.150) for large PS-GMH.
Conclusion
PS-GMH was frequently observed in extremely preterm infants; however, it did not independently predict adverse neurodevelopmental outcomes.
9.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
10.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.

Result Analysis
Print
Save
E-mail