1.Efficacy and safety of concomitant left atrial appendage clipping during heart valve surgery: a report of 58 cases.
Zheng XU ; Haiyan XIANG ; Jiwei WANG ; Chen LIU ; Yanhua TANG ; Juesheng YANG
Journal of Zhejiang University. Medical sciences 2025;54(2):250-256
OBJECTIVES:
To analyze the efficacy and safety of concomitant left atrial appendage clipping during heart valve surgery for valvular heart disease patients with atrial fibrillation.
METHODS:
Fifty-eight patients who underwent concomitant left atrial appendage clipping during cardiac valve surgery in the Second Affiliated Hospital of Nanchang University from January 2017 to June 2023 were included in the analysis, including 1 case who underwent aortic valve replacement, 49 cases who underwent mitral valve replace-ment (or valvuloplasty)+tricuspid valvuloplasty, and 8 cases who underwent double valve replacement+tricuspid valvuloplasty (3 cases combined with coronary artery bypass grafting). The patients were followed up for 3-36 months [(16.69±6.61) months] after operation, and the changes of cardiac function and the occurrence of serious adverse complications were evaluated.
RESULTS:
The cardiopulmonary bypass time ranged from 75 to 145 min [(102.50±21.03) min], and the aortic cross-clamp time ranged from 35 to 80 min [(58.02±14.63) min]. The length of postoperative intensive care unit stay was 1 to 5 days [(2.47±0.82) d], and the length of postoperative hospital stay was 7 to 22 days [(10.84±2.69) d]. Cardiac ultrasound indicated complete closure of the left atrial appendage in all cases. During the follow-up, New York Heart Association (NYHA) functional classifications were improved in 54 patients. No left atrial appendage-related bleeding events or other perioperative complications were observed; and no cerebral infarction, limb embolism events, or mortality cases occurred during the follow-up.
CONCLUSIONS
For valvular heart disease patients with atrial fibrillation, concomitant left atrial appendage clipping during cardiac valve surgery demonstrates efficacy and safety, with no severe adverse events during a medium-term follow-up.
Humans
;
Atrial Appendage/surgery*
;
Atrial Fibrillation/complications*
;
Male
;
Female
;
Heart Valve Diseases/complications*
;
Aged
;
Middle Aged
;
Heart Valve Prosthesis Implantation/methods*
;
Treatment Outcome
;
Cardiac Surgical Procedures/methods*
;
Mitral Valve/surgery*
2.Simulation Study of Myocardial Tissue Ablation Effects Using Flower Petal-Structured Electrodes in Pulsed Ablation.
Chinese Journal of Medical Instrumentation 2025;49(2):125-133
This study aims to evaluate the application of flower petal-structured electrodes in pulsed field ablation (PFA) technology, with a particular focus on their performance in myocardial tissue ablation. Through a combination of simulation techniques and in vitro experiments, the study investigates the effects of different voltage levels, electrode-to-tissue contact distances, and their impact on ablation depth, continuity, and transmurality. The research methods include the construction of a myocardial tissue simulation model, electric field distribution simulation using COMSOL Multiphysics, and in vitro ablation experiments on potato tissue. The results indicate that as voltage increases, the ablation depth significantly increases. At a voltage of 2500 V, a transmural ablation depth of 4 mm can be achieved, and the ablation area remains relatively continuous. The in vitro experiments confirm the consistency of the simulation results, and pulsed field ablation does not induce significant temperature rise, confirming its non-thermal characteristic. The conclusion suggests that PFA technology requires less electrode contact and offers higher ablation efficiency, providing a new technological pathway for the clinical treatment of atrial fibrillation and effectively reducing the risk of complications associated with traditional ablation techniques.
Electrodes
;
Catheter Ablation/instrumentation*
;
Computer Simulation
;
Flowers
;
Atrial Fibrillation/surgery*
;
Myocardium
3.Technical standards for performing radiofrequency catheter ablation for atrial fibrillation: a series of consortium standards.
Chinese Journal of Internal Medicine 2025;64(1):23-35
Atrial fibrillation (AF) has emerged as a major global cardiovascular disease in the 21st century. In China, there are greater than 12 million patients with AF, and its incidence continues to rise. AF affects patients' quality of life and significantly increases the risks of mortality, stroke, heart failure, cognitive impairment, and dementia. In recent years, multiple clinical guidelines have expanded the indications for catheter ablation and raised its level of recommendation. Concurrently, there has been a rapid and sustained increase in the number of AF ablation procedures performed across China. Among these, radiofrequency catheter ablation remains the most used method. Consequently, the Chinese Heart Rhythm Society of the Chinese Society of Biomedical Engineering, in collaboration with 40 arrhythmia centers and 60 leading clinical experts specializing in AF catheter ablation, developed a comprehensive set of standards. These standards were developed based on extensive clinical experience accumulated in recent years and the latest national and international AF guidelines and consensus documents. They address five critical domains: periprocedural management, intra-atrial septal puncture, anatomical reconstruction and electroanatomic mapping, ablation, and complication identification and management. By providing a structured framework, these standards aim to guide AF catheter ablation practice, thereby enhancing procedural safety and efficacy.
Humans
;
Catheter Ablation/standards*
;
Atrial Fibrillation/surgery*
;
China
5.Ablation therapies for paroxysmal atrial fibrillation: A systematic review and patient-level network meta-analysis.
Khi Yung FONG ; Joseph J ZHAO ; Yiong Huak CHAN ; Yue WANG ; Colin YEO ; Vern Hsen TAN
Annals of the Academy of Medicine, Singapore 2023;52(1):27-40
INTRODUCTION:
Despite promising trials, catheter ablation is still regarded as an adjunct to antiarrhythmic drugs (AADs) in the treatment of paroxysmal atrial fibrillation (PAF). This study aimed to compare the effectiveness of various ablation therapies and AADs.
METHOD:
Randomised controlled trials or propensity score-matched studies comparing atrial tachyarrhythmia recurrence among any combination of ablation modalities or AAD were retrieved. Kaplan-Meier curves and risk tables for this outcome were graphically reconstructed to extract patient-level data. Frequentist network meta-analysis (NMA) using derived hazard ratios (HRs), as well as 2 restricted mean survival time (RMST) NMAs, were conducted. Treatment strategies were ranked using P-scores.
RESULTS:
Across 24 studies comparing 6 ablation therapies (5,132 patients), Frequentist NMA-derived HRs of atrial fibrillation recurrence compared to AAD were 0.35 (95% confidence interval [CI]=0.25-0.48) for cryoballoon ablation (CBA), 0.34 (95% CI=0.25-0.47) for radiofrequency ablation (RFA), 0.14 (95% CI=0.07-0.30) for combined CBA and RFA, 0.20 (95% CI=0.10-0.41) for hot-balloon ablation, 0.43 (95% CI=0.15-1.26) for laser-balloon ablation (LBA), and 0.33 (95% CI=0.18-0.62) for pulmonary vein ablation catheter. RMST-based NMAs similarly showed significant benefit of all ablation therapies over AAD. The combination of CBA + RFA showed promising long-term superiority over CBA and RFA, while LBA showed favourable short-term efficacy.
CONCLUSION
The advantage of ablation therapies over AAD in preventing atrial tachyarrhythmia recurrence suggests that ablation should be considered as the first-line treatment for PAF in patients fit for the procedure. The promising nature of several specific therapies warrants further trials to elicit their long-term efficacy and perform a cost-benefit analysis.
Humans
;
Anti-Arrhythmia Agents/therapeutic use*
;
Atrial Fibrillation/surgery*
;
Catheter Ablation/methods*
;
Heart Atria
;
Network Meta-Analysis
;
Recurrence
;
Treatment Outcome
;
Randomized Controlled Trials as Topic
6.Surgical treatment for obstructive hypertrophic cardiomyopathy: a five-year single-center experience of 421 cases.
Fang Yu LIU ; Qiang JI ; Yu Lin WANG ; Jin Miao CHEN ; Li Li DONG ; Wen Jun DING ; Hao LAI ; Chun Sheng WANG
Chinese Journal of Surgery 2023;61(3):201-208
Objectives: To examine the short-term and mid-term effects of surgical treatment of obstructive hypertrophic cardiomyopathy (HCM) in one center. Methods: The perioperative data and short-term follow-up outcomes of 421 patients with obstructive HCM who received surgical treatment at Department of Cardiac Surgery, Zhongshan Hospital, Fudan University from January 2017 to December 2021 were analyzed retrospectively. There were 207 males and 214 females, aged (56.5±11.7) years (range: 19 to 78 years). Preoperative New York Heart Association (NYHA) classification included 45 cases of class Ⅱ, 328 cases in class Ⅲ, and 48 cases in class Ⅳ. Fifty-eight patients were diagnosed with latent obstructive HCM and 257 patients had moderate or more mitral regurgitation with 56 patients suffering from intrinsic mitral valve diseases. All procedures were completed by a multidisciplinary team, including professional echocardiologists involving in preoperative planning for proper mitral valve management strategies and intraoperative monitoring. A total of 338 patients underwent septal myectomy alone, and 59 patients underwent mitral valve surgery along with myectomy. A single transaortic approach was used in 355 patients, and a right atrial-atrial septal/atrial sulcus approach was used in 51 other patients. Long-handled minimally invasive surgical instruments were used for the procedures. Student t test, Wilcoxon rank sum test, χ2 test or Fisher exact test were used to compare the data before and after surgery. Results: The aortic cross-clamping time of septal myectomy alone was (34.3±8.5) minutes (range: 21 to 94 minutes). Eighteen patients had intraoperative adverse events and underwent immediate reoperation, including residual obstruction (10 patients), left ventricular free wall rupture (4 patients), ventricular septal perforation (3 patients), and aortic valve perforation (1 patient). Four patients died during hospitalization, and 11 patients developed complete atrioventricular block requiring permanent pacemaker implantation. After discharge, 384 (92.1%) patients received a follow-up visit with a median duration of 9 months. All follow-up patients survived with significantly improved NYHA classifications: 216 patients in class Ⅰ and 168 patients in class Ⅱ (χ2=662.73, P<0.01 as compared to baseline). At 6 months after surgery, follow-up echocardiography showed that the thickness of the ventricular septum ((13.6±2.5) mm vs. (18.2±3.0) mm, t=23.51, P<0.01) and the peak left ventricular outflow tract gradient ((12.0±6.3) mmHg vs. (93.4±19.8) mmHg, 1 mmHg=0.133 kPa, t=78.29, P<0.01) were both significantly lower than baseline values. Conclusion: The construction of the surgical team (including echocardiography experts), proper mitral valve management strategies, identification and management of sub-mitral-valve abnormalities, and application of long-handled minimally invasive surgical instruments are important for the successful implementation of septal myectomy with satisfactory short-and medium-term outcomes.
Male
;
Female
;
Humans
;
Retrospective Studies
;
Atrial Fibrillation
;
Treatment Outcome
;
Cardiomyopathy, Hypertrophic/surgery*
;
Mitral Valve Insufficiency/surgery*
;
Ventricular Septum
7.Effect of combined catheter ablation of atrial fibrillation and left atrial appendage closure on left atrial structure compared with a single procedure.
Zhentao FEI ; Ming LIU ; Pengcheng YAO ; Mingzhe ZHAO ; Changqi GONG ; Mu CHEN ; Yudong FEI ; Binfeng MO ; Rui ZHANG ; Yichi YU ; Yuli YANG ; Qian WANG ; Wei LI ; Pengpai ZHANG ; Jian SUN ; Qunshan WANG ; Yigang LI
Chinese Medical Journal 2023;136(24):3010-3012

Result Analysis
Print
Save
E-mail