1.Is unicompartmental knee arthroplasty a better choice than total knee arthroplasty for unicompartmental osteoarthritis? A systematic review and meta-analysis of randomized controlled trials.
Kuanyu XIA ; Lang MIN ; Wenqing XIE ; Guang YANG ; Dong Keon YON ; Seung Won LEE ; Ai KOYANAGI ; Louis JACOB ; Lee SMITH ; Jae Il SHIN ; Masoud RAHMATI ; Wenfeng XIAO ; Yusheng LI
Chinese Medical Journal 2025;138(13):1568-1577
BACKGROUND:
The choice of unicompartmental knee arthroplasty (UKA) vs . total knee arthroplasty (TKA) in the surgical treatment of knee osteoarthritis (KOA) remains controversial. This study aimed to perform a systematic review and meta-analysis of randomized controlled trials (RCTs) to compare the clinical results of UKA and TKA for treating unicompartmental KOA.
METHODS:
PubMed, Embase, and the Cochrane Library were systematically searched for articles published up to January 2, 2023. The literature was rigorously screened to include only RCTs comparing UKA and TKA for unicompartmental KOA. A systematic review and meta-analysis were performed to calculate the mean difference (MD), relative risk (RR), and 95% confidence interval (CI) according to the Cochrane standards.
RESULTS:
Thirteen publications involving 683 UKAs and 683 TKAs were analyzed. Except for one study with a follow-up period of 15 years, all outcome measures reported were within 5 years of follow-up. Meta-analysis showed better knee recovery (MD: 1.23; 95% CI: 1.01-1.45; P <0.001), greater knee function (MD: 1.78; 95% CI: 0.34-3.22; P = 0.020), less pain (MD: 0.75; 95% CI: 0.43-1.06; P <0.001), and better health status (MD: 3.75; 95% CI: 0.81-6.69; P = 0.010) after UKA than TKA. However, considering the minimal clinically important difference values for these variables, the findings were not clinically relevant. Moreover, UKA patients had fewer complications (RR: 0.59; 95% CI: 0.45-0.78; P <0.001) and shorter hospital stays (MD: -0.89; 95% CI: -1.57 to -0.22; P = 0.009) than did TKA patients. There were no statistically significant differences in terms of postoperative range of movement, revision, failure, operation time, and patient satisfaction.
CONCLUSIONS
In terms of clinical efficacy, there was no obvious advantage of UKA over TKA in the surgical treatment of knee OA when considering the minimal clinically important difference. The main advantage of UKA over TKA is that it leads to fewer complications and a shorter length of hospital stay. It is ideal to perform prospective studies with longer follow-up periods to fully evaluate the long-term efficacy and safety of the two procedures in the future.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Randomized Controlled Trials as Topic
;
Treatment Outcome
2.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
3.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
4.Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability.
Yuhan ZHANG ; Jing ZHANG ; Tianqi DONG ; Xuan ZHANG ; Weijie ZHANG ; Lei GUO ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(4):782-789
Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.
Knee Prosthesis
;
Humans
;
Finite Element Analysis
;
Tibia/surgery*
;
Elastic Modulus
;
Arthroplasty, Replacement, Knee/methods*
;
Stress, Mechanical
;
Metals
;
Prosthesis Design
;
Knee Joint/surgery*
;
Biomechanical Phenomena
5.Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities.
Chen MENG ; Yongqing XU ; Rongmao SHI ; Luqiao PU ; Jian'an JI ; Xingyou YAO ; Xizong ZHOU ; Chuan LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):5-12
OBJECTIVE:
To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
METHODS:
The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups ( P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score.
RESULTS:
There was no significant difference in operation time between the two groups ( P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group ( P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups ( P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group ( P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant ( P>0.05).
CONCLUSION
Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Robotic Surgical Procedures/methods*
;
Male
;
Female
;
Retrospective Studies
;
Range of Motion, Articular
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Osteotomy/methods*
;
Knee Joint/physiopathology*
;
Operative Time
6.Effectiveness of digital three-dimensional printing osteotomy guide plate assisted total knee arthroplasty in treatment of knee osteoarthritis patients with femoral internal implant.
Chao LI ; Binbin ZHANG ; Xiangping LIU ; Haiya LI ; Jingtang ZHANG ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):151-157
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants.
METHODS:
The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups ( P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups.
RESULTS:
The operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group ( P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant ( P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation ( P<0.05), and there was no significant difference between the two groups at last follow-up ( P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/instrumentation*
;
Male
;
Retrospective Studies
;
Female
;
Printing, Three-Dimensional
;
Femur/surgery*
;
Middle Aged
;
Bone Plates
;
Range of Motion, Articular
;
Aged
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods*
;
Knee Prosthesis
;
Knee Joint/surgery*
;
Operative Time
7.Analgesic effect of "cocktail" analgesia containing high-dose compound betamethasone after revision hip arthroplasty and the use of opioid drugs.
Ning YANG ; Wulamu WUHUZI ; Xiaobin GUO ; Yicheng LI ; Xiaogang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):314-319
OBJECTIVE:
To investigate the analgesic effect of locally injecting a "cocktail" analgesia containing a high-dose compound betamethasone during revision hip arthroplasty, and also to study the usage of opioid drugs.
METHODS:
A retrospective analysis was conducted on the clinical data of 180 patients who underwent revision hip arthroplasty due to aseptic loosening of the hip prosthesis between January 2015 and December 2021. Among them, 95 patients received intraoperative injection of "cocktail" analgesia containing high-dose compound betamethasone (group A), and 85 patients received intraoperative injection of traditional "cocktail" analgesia (group B). There was no significant difference in baseline data such as gender, age, body mass index, presence or absence of diabetes mellitus between the two groups ( P>0.05). The hospital stay, use of opioid drugs within 72 hours, and the incidence of adverse reactions within 72 hours after operation [including nausea and vomiting, insomnia, deep venous thrombosis (DVT), infection, etc.] were recorded and compared between the two groups. The pain relief of patients was evaluated using the static and dynamic visual analogue scale (VAS) scores at 12, 24, 48, and 72 hours after operation. The incidence of complications (including prosthesis re-loosening, hip joint dislocation, hip joint stiffness, limping, chronic pain, etc.) at 2 years after operation was recorded, and the Harris Hip Score (HHS) was used to evaluate the function at 2 years after operation.
RESULTS:
In group A, the utilization rate of opioid drugs within 72 hours after operation was significantly lower than that in group B ( P<0.05). However, there was no significant difference between the two groups in terms of hospital stay, as well as the incidence of adverse reactions such as nausea and vomiting, insomnia, DVT, and infection within 72 hours after operation ( P>0.05). The VAS scores of both groups decreased with time, and the differences between different time points were significant ( P<0.05). The static and dynamic VAS scores of group A were significantly lower than those of group B at 12, 24, and 48 hours after operation ( P<0.05), but there was no significant difference in static and dynamic VAS scores between the two groups at 72 hours after operation ( P>0.05). All patients in both groups were followed up 2-8 years, with an average of 5.73 years. At 2 years after operation, no significant difference was found between the two groups in the incidence of complications and HHS score ( P>0.05).
CONCLUSION
"Cocktail" analgesia containing a high-dose compound betamethasone for early analgesia after revision hip arthroplasty can effectively reduce postoperative pain and the use of opioid drugs, but will not increase the incidence of infection and DVT after operation.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Betamethasone/therapeutic use*
;
Retrospective Studies
;
Male
;
Female
;
Analgesics, Opioid/administration & dosage*
;
Pain, Postoperative/prevention & control*
;
Middle Aged
;
Reoperation
;
Aged
;
Analgesia/methods*
;
Adult
;
Pain Measurement
;
Pain Management/methods*
;
Prosthesis Failure
;
Hip Prosthesis
8.Clinical study of reverse total shoulder arthroplasty versus open reduction and internal plate fixation for treatment of Neer three/four-part proximal humeral fractures in elderly.
Yuhui YANG ; Zhantao DENG ; Qingtian LI ; Xiurui ZHANG ; Yunzhi PENG ; Ruiying ZHANG ; Yuanchen MA ; Qiujian ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):412-419
OBJECTIVE:
To compare the effectiveness and shoulder function of reverse total shoulder arthroplasty (RTSA) and open reduction and internal fixation (ORIF) in the treatment of Neer three/four-part proximal humeral fractures in the elderly.
METHODS:
Randomized controlled analysis was conducted on 68 patients over 70 years old with Neer three/four-part proximal humeral fractures treated with RTSA or ORIF between January 2020 and June 2022. The patients were randomly divided into RTSA group ( n=32) and ORIF group ( n=36). There was no significant difference ( P>0.05) in the baseline data such as age, gender, body mass index, injured side, Neer classification, and preoperative Charlson comorbidity index, visual analogue scale (VAS) score, Constant shoulder score, Oxford shoulder score (OSS), and hemoglobin (Hb). The operation time, intraoperative blood loss, reduction of Hb on the 3rd day after operation, hospital stay, total cost of hospitalization, complication incidence, range of motion of shoulder joint at 2 years after operation, VAS score before operation and at 5 days and 1 month after operation, Constant shoulder score and OSS score before operation and at 2 years after operation, and imaging results during follow-up were recorded and compared between the two groups.
RESULTS:
Compared with the ORIF group, the RTSA group had longer operation time, less intraoperative blood loss, and higher total cost of hospitalization ( P<0.05). There was no significant difference in Hb reduction on the 3rd day after operation between the two groups ( P>0.05). The VAS scores significantly improved in both groups at 5 days and 1 month after operation ( P<0.05), but there was no significant difference between the two groups ( P>0.05). All patients were followed up 26-35 months, with an average of 31.2 months. In the RTSA group, there were 2 cases of poor healing of superficial incision and 1 case of transient nerve injury. There was no complication such as bone resorption around the prosthesis, lucent band, prosthesis loosening, or periprosthetic fracture in all patients. In the ORIF group, there was 1 case of poor healing of superficial incision, 3 cases of nonunion of fracture, 1 case of arthritis secondary to humeral head necrosis, and 1 case of bone absorption of large tuberosity, and no displacement or fracture failure of internal fixation was found in all patients. There was no significant difference in the incidence of complications [9.4% (3/32) vs 16.7% (6/36)] between the two groups [ OR (95% CI): 0.828 (0.171, 4.014), P=0.814]. In the RTSA group, 28 cases were graded 0 and 4 cases were graded 1 at 2 years after operation. Constant and OSS scores of RTSA group were significantly better than those of ORIF group ( P<0.05). The Constant score was significantly better than ORIF group in activity and strength, range of motion, lifting, abduction, and external rotation ( P<0.05), and there was no significant difference in pain, daily function, and internal rotation between the two groups ( P>0.05). The RTSA group had a significantly greater range of motion in lifting, abduction, and external rotation than ORIF group ( P<0.05), but there was no significant difference in internal rotation between the two groups ( P>0.05).
CONCLUSION
Application of RTSA as the initial treatment of Neer three/four-part proximal humeral fractures in the elderly can achieve better rehabilitation of joint activity and lower risk of early reoperation, and improve the quality of life of elderly fracture patients. However, the difficulty of revision and the high cost of treatment require the surgeon to pay full attention and strictly grasp the indications.
Humans
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Shoulder Fractures/surgery*
;
Arthroplasty, Replacement, Shoulder/methods*
;
Aged
;
Bone Plates
;
Open Fracture Reduction/methods*
;
Range of Motion, Articular
;
Treatment Outcome
;
Shoulder Joint/physiopathology*
;
Aged, 80 and over
;
Operative Time
;
Postoperative Complications/epidemiology*
;
Length of Stay
9.Feasibility study on measuring anteversion angle of acetabular prosthesis after total hip arthroplasty using arbitrary point method.
Bowen LI ; Longyuan LI ; Heng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):420-424
OBJECTIVE:
To explore the reliability and accuracy of the arbitrary point method for measuring the anteversion angle of acetabular prosthesis after total hip arthroplasty (THA) based on pelvic X-ray films.
METHODS:
The clinical data of 23 patients (25 hips) who underwent THA between December 2018 and September 2023 and met the selection criteria were retrospectively analyzed. Among them, there were 16 males and 7 females, with an average age of 57.6 years (range, 34-81 years); 13 hips had THA on the left side and 12 on the right side. There were 19 cases (21 hips) of osteonecrosis of the femoral head, 2 cases (2 hips) of femoral neck fractures, 1 case (1 hip) of developmental dysplasia of the hip, and 1 case (1 hip) of osteoarthritis. After THA, all patients underwent X-ray examination and CT scan. Three physicians measured the anteversion angle of acetabular prosthesis using the arbitrary point method and the CT measurement method respectively, and repeated the measurements three times. The results of the two measurement methods were compared, and the intraclass correlation coefficient (ICC) was employed to assess the reproducibility of the methods.
RESULTS:
The anteversion angles of acetabular prosthesis were (15.87±7.73)° measured by the arbitrary point method, and (15.31±7.89)° measured by CT measurement method. There was no significant difference between the two methods ( t=1.515, P=0.143). The ICC of the measurement results by the arbitrary point method for the three physicians were 0.97 ( P<0.001), 0.96 ( P<0.001), and 0.96 ( P<0.001), respectively; and the ICC of the measurement results by CT method were 0.93 ( P<0.001), 0.93 ( P<0.001), and 0.94 ( P<0.001), respectively.
CONCLUSION
The arbitrary point method for measuring the anteversion angle of acetabular prosthesis after THA based on pelvic X-ray film is easy to operate, accurate, and has high reproducibility.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Hip Prosthesis
;
Acetabulum/surgery*
;
Aged, 80 and over
;
Retrospective Studies
;
Adult
;
Reproducibility of Results
;
Feasibility Studies
;
Tomography, X-Ray Computed
10.Application of femoral condyle sliding osteotomy in initial total knee arthroplasty.
Xin WANG ; Jian MA ; Songyan ZHANG ; Rui TAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):425-433
OBJECTIVE:
To investigate the effect of femoral condyle sliding osteotomy (FCSO) on the flexion gap and external rotation of the prosthesis in balancing coronal instability during initial total knee arthroplasty (TKA).
METHODS:
Between November 2021 and October 2024, FCSO technique was applied to balance the coronal medial and lateral spaces during initial TKA in 3 patients, including medial condyle sliding osteotomy (MCSO) and lateral condyle sliding osteotomy (LCSO). There were 1 male and 2 females with the age of 81, 68, and 68 years old. The affected knee has varus or valgus deformity, with tibia-femoral angles of 169.7°, 203.3°, and 162.2°, respectively. The hip-knee-ankle angle (HKA), range of motion (ROM), knee society scoring system (KSS), and pain visual analogue scale (VAS) score were used to evaluate joint function and pain relief. Based on model bone, the thickness and bone bed area of the medial and lateral femoral condyle osteotomy blocks in FCSO were measured. During TKA in 12 patients, the range of osteotomy block movement was evaluated. By simplifying the upward and forward movement of the osteotomy block into a geometric model, the impact of movement on the flexion gap and external rotation of the prosthesis was calculated.
RESULTS:
After application of FCSO during TKA, the limb alignment and medial and lateral balance at extension and flexion positions were restored in 3 patients. Three patients were followed up 23, 11, and 3 months, respectively. Postoperative HKA, pain VAS score, KSS score, and ROM all showed significant improvement compared to preoperative levels. The maximum thickness of osteotomy blocks by MCSO and LCSO was 17 and 12 mm, respectively. The simple upward movement of the osteotomy block mainly affected the extension gap, and had little effect on the flexion gap and external rotation of the prosthesis. Moving the osteotomy block forward at the same time had a significant impact on the flexion gap and external rotation of the prosthesis, especially on LCSO. Mild forward movement leaded to a decrease in external rotation of more than 3°, which had a serious impact on the patellar trajectory.
CONCLUSION
FCSO can effectively solve the problem of imbalance between the medial and lateral spaces during initial TKA, avoiding knee joint instability caused by excessive loosening and limiting the use of constrained condylar prosthesis. The distance for the downward movement of the osteotomy block in MCSO and LCSO was 3-5 mm and 6-8 mm, respectively, with 10-15 mm of space for forward movement and almost no space for backward movement. For MCSO, the upward and forward movement of the osteotomy block will increase the external rotation of the prosthesis, which is beneficial for improving the patellar trajectory and suitable for valgus knee. LCSO is suitable for varus knee, and the osteotomy block only slides vertically up and down without moving forward and backward.
Humans
;
Osteotomy/methods*
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Range of Motion, Articular
;
Femur/surgery*
;
Knee Joint/physiopathology*
;
Aged, 80 and over
;
Knee Prosthesis
;
Treatment Outcome
;
Osteoarthritis, Knee/surgery*

Result Analysis
Print
Save
E-mail