1.Is unicompartmental knee arthroplasty a better choice than total knee arthroplasty for unicompartmental osteoarthritis? A systematic review and meta-analysis of randomized controlled trials.
Kuanyu XIA ; Lang MIN ; Wenqing XIE ; Guang YANG ; Dong Keon YON ; Seung Won LEE ; Ai KOYANAGI ; Louis JACOB ; Lee SMITH ; Jae Il SHIN ; Masoud RAHMATI ; Wenfeng XIAO ; Yusheng LI
Chinese Medical Journal 2025;138(13):1568-1577
BACKGROUND:
The choice of unicompartmental knee arthroplasty (UKA) vs . total knee arthroplasty (TKA) in the surgical treatment of knee osteoarthritis (KOA) remains controversial. This study aimed to perform a systematic review and meta-analysis of randomized controlled trials (RCTs) to compare the clinical results of UKA and TKA for treating unicompartmental KOA.
METHODS:
PubMed, Embase, and the Cochrane Library were systematically searched for articles published up to January 2, 2023. The literature was rigorously screened to include only RCTs comparing UKA and TKA for unicompartmental KOA. A systematic review and meta-analysis were performed to calculate the mean difference (MD), relative risk (RR), and 95% confidence interval (CI) according to the Cochrane standards.
RESULTS:
Thirteen publications involving 683 UKAs and 683 TKAs were analyzed. Except for one study with a follow-up period of 15 years, all outcome measures reported were within 5 years of follow-up. Meta-analysis showed better knee recovery (MD: 1.23; 95% CI: 1.01-1.45; P <0.001), greater knee function (MD: 1.78; 95% CI: 0.34-3.22; P = 0.020), less pain (MD: 0.75; 95% CI: 0.43-1.06; P <0.001), and better health status (MD: 3.75; 95% CI: 0.81-6.69; P = 0.010) after UKA than TKA. However, considering the minimal clinically important difference values for these variables, the findings were not clinically relevant. Moreover, UKA patients had fewer complications (RR: 0.59; 95% CI: 0.45-0.78; P <0.001) and shorter hospital stays (MD: -0.89; 95% CI: -1.57 to -0.22; P = 0.009) than did TKA patients. There were no statistically significant differences in terms of postoperative range of movement, revision, failure, operation time, and patient satisfaction.
CONCLUSIONS
In terms of clinical efficacy, there was no obvious advantage of UKA over TKA in the surgical treatment of knee OA when considering the minimal clinically important difference. The main advantage of UKA over TKA is that it leads to fewer complications and a shorter length of hospital stay. It is ideal to perform prospective studies with longer follow-up periods to fully evaluate the long-term efficacy and safety of the two procedures in the future.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Randomized Controlled Trials as Topic
;
Treatment Outcome
2.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
3.Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability.
Yuhan ZHANG ; Jing ZHANG ; Tianqi DONG ; Xuan ZHANG ; Weijie ZHANG ; Lei GUO ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(4):782-789
Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.
Knee Prosthesis
;
Humans
;
Finite Element Analysis
;
Tibia/surgery*
;
Elastic Modulus
;
Arthroplasty, Replacement, Knee/methods*
;
Stress, Mechanical
;
Metals
;
Prosthesis Design
;
Knee Joint/surgery*
;
Biomechanical Phenomena
4.Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities.
Chen MENG ; Yongqing XU ; Rongmao SHI ; Luqiao PU ; Jian'an JI ; Xingyou YAO ; Xizong ZHOU ; Chuan LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):5-12
OBJECTIVE:
To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
METHODS:
The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups ( P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score.
RESULTS:
There was no significant difference in operation time between the two groups ( P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group ( P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups ( P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group ( P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant ( P>0.05).
CONCLUSION
Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Robotic Surgical Procedures/methods*
;
Male
;
Female
;
Retrospective Studies
;
Range of Motion, Articular
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Osteotomy/methods*
;
Knee Joint/physiopathology*
;
Operative Time
5.Effectiveness of digital three-dimensional printing osteotomy guide plate assisted total knee arthroplasty in treatment of knee osteoarthritis patients with femoral internal implant.
Chao LI ; Binbin ZHANG ; Xiangping LIU ; Haiya LI ; Jingtang ZHANG ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):151-157
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants.
METHODS:
The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups ( P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups.
RESULTS:
The operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group ( P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant ( P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation ( P<0.05), and there was no significant difference between the two groups at last follow-up ( P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/instrumentation*
;
Male
;
Retrospective Studies
;
Female
;
Printing, Three-Dimensional
;
Femur/surgery*
;
Middle Aged
;
Bone Plates
;
Range of Motion, Articular
;
Aged
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods*
;
Knee Prosthesis
;
Knee Joint/surgery*
;
Operative Time
6.Application of femoral condyle sliding osteotomy in initial total knee arthroplasty.
Xin WANG ; Jian MA ; Songyan ZHANG ; Rui TAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):425-433
OBJECTIVE:
To investigate the effect of femoral condyle sliding osteotomy (FCSO) on the flexion gap and external rotation of the prosthesis in balancing coronal instability during initial total knee arthroplasty (TKA).
METHODS:
Between November 2021 and October 2024, FCSO technique was applied to balance the coronal medial and lateral spaces during initial TKA in 3 patients, including medial condyle sliding osteotomy (MCSO) and lateral condyle sliding osteotomy (LCSO). There were 1 male and 2 females with the age of 81, 68, and 68 years old. The affected knee has varus or valgus deformity, with tibia-femoral angles of 169.7°, 203.3°, and 162.2°, respectively. The hip-knee-ankle angle (HKA), range of motion (ROM), knee society scoring system (KSS), and pain visual analogue scale (VAS) score were used to evaluate joint function and pain relief. Based on model bone, the thickness and bone bed area of the medial and lateral femoral condyle osteotomy blocks in FCSO were measured. During TKA in 12 patients, the range of osteotomy block movement was evaluated. By simplifying the upward and forward movement of the osteotomy block into a geometric model, the impact of movement on the flexion gap and external rotation of the prosthesis was calculated.
RESULTS:
After application of FCSO during TKA, the limb alignment and medial and lateral balance at extension and flexion positions were restored in 3 patients. Three patients were followed up 23, 11, and 3 months, respectively. Postoperative HKA, pain VAS score, KSS score, and ROM all showed significant improvement compared to preoperative levels. The maximum thickness of osteotomy blocks by MCSO and LCSO was 17 and 12 mm, respectively. The simple upward movement of the osteotomy block mainly affected the extension gap, and had little effect on the flexion gap and external rotation of the prosthesis. Moving the osteotomy block forward at the same time had a significant impact on the flexion gap and external rotation of the prosthesis, especially on LCSO. Mild forward movement leaded to a decrease in external rotation of more than 3°, which had a serious impact on the patellar trajectory.
CONCLUSION
FCSO can effectively solve the problem of imbalance between the medial and lateral spaces during initial TKA, avoiding knee joint instability caused by excessive loosening and limiting the use of constrained condylar prosthesis. The distance for the downward movement of the osteotomy block in MCSO and LCSO was 3-5 mm and 6-8 mm, respectively, with 10-15 mm of space for forward movement and almost no space for backward movement. For MCSO, the upward and forward movement of the osteotomy block will increase the external rotation of the prosthesis, which is beneficial for improving the patellar trajectory and suitable for valgus knee. LCSO is suitable for varus knee, and the osteotomy block only slides vertically up and down without moving forward and backward.
Humans
;
Osteotomy/methods*
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Range of Motion, Articular
;
Femur/surgery*
;
Knee Joint/physiopathology*
;
Aged, 80 and over
;
Knee Prosthesis
;
Treatment Outcome
;
Osteoarthritis, Knee/surgery*
7.Reconstruction of bone defects after resection of osteosarcoma in children with artificial hemi-knee prosthesis.
Rongkai SHEN ; Meng CHEN ; Fei CHEN ; Yaoguang SONG ; Xia ZHU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):824-830
OBJECTIVE:
To explore the effectiveness of artificial hemi-knee prosthesis reconstruction for bone defects after resection of pediatric osteosarcoma.
METHODS:
A retrospective analysis was conducted on the clinical data of 18 children with osteosarcoma who met the selection criteria and were treated between January 2016 and December 2019. There were 11 males and 7 females, aged 6-10 years (mean, 8.9 years). Osteosarcoma located in the distal femur in 11 cases and the proximal tibia in 7 cases. Among them, 12 cases were conventional osteosarcoma and 6 cases were small cell osteosarcoma, with a disease duration of 1-9 months (mean, 3.1 months). All patients received 2 cycles of preoperative chemotherapy with doxorubicin, cisplatin, and ifosfamide. After en bloc tumor segment resection, bone defects were reconstructed using custom-made artificial hemi-knee prostheses. Rehabilitation training was initiated at 8 weeks postoperatively under the protection of a knee immobilizer brace, combined with 4 cycles of adjuvant chemotherapy. During follow-up, lower limb growth length and limb shortening (compared with the healthy side) were measured, and limb function was evaluated using the Musculoskeletal Tumor Society-93 (MSTS-93) scoring system.
RESULTS:
All surgeries were successfully completed, with an operation time of 2.0-3.1 hours (mean, 2.4 hours) and intraoperative blood loss of 180-320 mL (mean, 230.0 mL). Incisional edge necrosis occurred in 1 case at 10 days postoperatively, while the incisions of the remaining 17 patients healed by first intention. One case developed periprosthetic infection caused by Staphylococcus aureus at 1 week postoperatively, which was cured after symptomatic treatment. All 18 patients were followed up 60-96 months (mean, 74.2 months). No local tumor recurrence was observed during follow-up. Imaging examinations showed prosthesis loosening in 2 cases, while the prosthesis of other patients were well-positioned. At last follow-up, the knee joint range of motion was 80°-120° (mean, 106.7°). The MSTS-93 score was 16-29 (mean, 24.7), with 12 cases rated as excellent, 5 good, and 1 fair. The patients' height increased by 12.8-20.0 cm (mean, 15.5 cm), the lower limb growth length was 6.0-13.0 cm (mean, 9.7 cm), and limb shortening was 1.8-4.6 cm (mean, 3.1 cm). There was no significant difference in MSTS-93 scores, lower limb growth length, or limb shortening between the distal femur group and the proximal tibia group ( P>0.05).
CONCLUSION
Artificial hemi-knee prosthesis reconstruction can preserve the adjacent normal epiphysis of the knee joint, maximize limb growth potential, and reduce adult limb length discrepancy, making it a suitable reconstruction option for children with knee osteosarcoma.
Humans
;
Osteosarcoma/surgery*
;
Male
;
Child
;
Female
;
Knee Prosthesis
;
Retrospective Studies
;
Bone Neoplasms/surgery*
;
Plastic Surgery Procedures/methods*
;
Tibia/surgery*
;
Femur/surgery*
;
Arthroplasty, Replacement, Knee/methods*
;
Treatment Outcome
;
Chemotherapy, Adjuvant
;
Femoral Neoplasms/surgery*
8.Observation on analgesic efficacy of ultrasound-guided high fascia iliac compartment block for tourniquet-related pain following total knee arthroplasty.
Qingqing YU ; Yingchao TANG ; Haiyu FU ; Li JIANG ; Benjing SONG ; Wei WANG ; Qingyun XIE ; Song CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(8):1045-1050
OBJECTIVE:
To evaluate the analgesic efficacy of ultrasound-guided high fascia iliaca compartment block (HFICB) in managing tourniquet-related pain following total knee arthroplasty (TKA).
METHODS:
A prospective randomized controlled trial was conducted involving 84 patients with severe knee osteoarthritis or rheumatoid arthritis who underwent unilateral TKA between March 2024 and December 2024. Patients were randomly assigned to two groups ( n=42) using a random number table. In the trial group, ultrasound-guided HFICB was performed preoperatively, with 0.2% ropivacaine injected into the fascia iliaca compartment. No intervention was administered in the control group. Baseline characteristics, including gender, age, surgical side, body mass index, and preoperative visual analogue scale (VAS) scores at rest and during movement, showed no significant difference between the two groups ( P>0.05). In both groups, a tourniquet was applied after osteotomy and before pulsed lavage, and removed after the closure of the first layer of the joint capsule. Postoperative assessments were conducted at 6, 12, 24, and 48 hours, including VAS scores at the tourniquet site (at rest and during movement), Bromage motor block scores, Ramsay sedation scores, and Bruggrmann comfort scale (BCS) scores to evaluate patient comfort. Additionally, the average tramadol consumption and incidence of nausea and vomiting within 48 hours postoperatively were recorded and compared.
RESULTS:
In the trial group and control group, VAS scores during movement at the tourniquet site significantly improved at all postoperative time points compared to preoperative levels ( P<0.05). VAS scores at rest increased transiently at 6 hours after operation in both groups, and then gradually decreased to the preoperative level. Except that there was no significant difference at 48 hours after operation in the trial group ( P>0.05), there were significant differences at other time points of two groups compared to preoperative score ( P<0.05). Except for VAS score at rest at 6 hours, VAS score during movement at 48 hours, and BCS comfort score at 48 hours ( P>0.05), the trial group showed significantly better outcomes than the control group in terms of VAS score at rest, VAS score during movement, Ramsay sedation scores, and BCS comfort scores at all other time points ( P<0.05). No significant difference was found in Bromage motor block scores between the groups ( P>0.05). Tramadol was used in 3 patients in the trial group and 7 patients in the control group within 48 hours after operation, the dosage was (133.30±14.19) mg and (172.40±22.29) mg, showing significant difference ( P<0.05). Nausea and vomiting occurred in 4 patients (9.5%) in the trial group and 3 patients (7.1%) in the control group, with no significant difference in incidence between groups ( P>0.05).
CONCLUSION
Ultrasound-guided HFICB provides effective analgesia for tourniquet-related pain following TKA, facilitates early postoperative functional recovery of the knee joint, and may serve as a valuable clinical option for postoperative pain management in TKA patients.
Humans
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Nerve Block/methods*
;
Male
;
Female
;
Pain, Postoperative/etiology*
;
Tourniquets/adverse effects*
;
Prospective Studies
;
Middle Aged
;
Ropivacaine/administration & dosage*
;
Aged
;
Ultrasonography, Interventional
;
Anesthetics, Local/administration & dosage*
;
Pain Measurement
;
Fascia
;
Osteoarthritis, Knee/surgery*
;
Treatment Outcome
;
Arthritis, Rheumatoid/surgery*
9.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
10.Clinical study on the efficacy of unicompartmental knee arthroplasty in elderly patients with medial osteoarthritis and anterior cruciate ligament deficiency.
Hai-Song LIANG ; Dong SHENG ; Xiao-Su HUI ; Xin-Wen BAI ; Yu DENG ; Cong-Ke SHU ; Fa-Song XIANG
China Journal of Orthopaedics and Traumatology 2025;38(4):336-342
OBJECTIVE:
To investigate the short-and med-term clinical efficacy of unicompartmental knee arthroplasty(UKA)for the treatment of medial knee osteoarthritis (OA) in elderly patients with anterior cruciate ligament deficiency(ACLD).
METHODS:
A retrospective analysis was conducted on 31 patients aged over 75 years old with primary medial knee OA and ACLD who underwent UKA between January 2018 and December 2022. The cohort included 12 males and 19 females, aged from 75 to 91 years with an average age of (79.56±4.54) years, with 13 left knee, 16 right knee, and 2 bilateral knees. Clinical outcomes were assessed preoperatively and at final follow-up using the visual analogue scale (VAS), Hospital for Special Surgery(HSS) score, range of motion (ROM), hip-knee-ankle angle (HKA), and tibial component posterior slope angle (TCPSA). Complications such as infection, prosthesis wear, prosthesis loosening, and dislocation were also recorded.
RESULTS:
All 31 patients were followed up from 12 to 63 months with an average of (28.34±10.56) months. The average postoperative TCPSA was (4.83±1.31)° ranged from 2.5° to 6.8°. At the final follow-up, there was significant improvement in VAS (3.24±0.53) vs. (6.59±0.69), HSS score (85.19±4.45) vs. (64.38±5.94), ROM (118.83±5.38)° vs. (98.85±4.08)°, and HKA (176.83±5.16)° vs. (169.57±6.28)° compared to preoperative values (P<0.05). No cases of infection, prosthesis loosening, or dislocation were reported.
CONCLUSION
UKA provides favorable short-and mid-term outcomes for elderly patients with medial knee OA and ACLD . However, long-term clinical efficacy needs further investigation through extended follow-up.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Osteoarthritis, Knee/physiopathology*
;
Retrospective Studies
;
Aged, 80 and over
;
Range of Motion, Articular
;
Anterior Cruciate Ligament Injuries/surgery*

Result Analysis
Print
Save
E-mail