1.Effectiveness of digital three-dimensional printing osteotomy guide plate assisted total knee arthroplasty in treatment of knee osteoarthritis patients with femoral internal implant.
Chao LI ; Binbin ZHANG ; Xiangping LIU ; Haiya LI ; Jingtang ZHANG ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):151-157
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants.
METHODS:
The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups ( P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups.
RESULTS:
The operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group ( P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant ( P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation ( P<0.05), and there was no significant difference between the two groups at last follow-up ( P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/instrumentation*
;
Male
;
Retrospective Studies
;
Female
;
Printing, Three-Dimensional
;
Femur/surgery*
;
Middle Aged
;
Bone Plates
;
Range of Motion, Articular
;
Aged
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods*
;
Knee Prosthesis
;
Knee Joint/surgery*
;
Operative Time
2.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
3.Study on accuracy of prosthesis size selection for Naton robot-assisted medial unicondylar knee arthroplasty.
Longfei CHEN ; Yue SONG ; Wang GU ; Shaokui NAN ; Zhengxin MENG ; Haifeng LI
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(11):1312-1316
OBJECTIVE:
To analyze the accuracy of prosthesis size selection in Naton robot-assisted medial unicondyle knee arthroplasty by comparing the actual prosthesis size used during operation and the preoperative planning.
METHODS:
The clinical data of 100 patients (110 knees) who underwent Naton robot-assisted medial unicondylar knee arthroplasty between June 2023 and July 2024 was retrospectively analyzed, including 47 knees on left side and 63 knees on right side. There were 37 males (40 knees) and 63 females (70 knees) with a mean age of 65.4 years (range, 59-71 years). Body mass index was 22.2-28.6 kg/m 2 (mean, 25.4 kg/m 2). The disease duration ranged from 1 to 8 years (mean, 3.4 years). Preoperative planning was performed by Naton robotic surgical system based on lower limb CT data. The final prosthesis size after osteotomy was recorded and compared with the preoperative plan to analyse whether it was consistent with the preoperative plan, as well as the situation of knee flexion and extension gaps (<0.5 mm, >2.0 mm) corresponding to the different models of prostheses.
RESULTS:
During operation, 5 patients (5 knees) were treated with traditional UKA due to mechanical arm failure, software obstacles, significant bone amputation bias, or loose reference frame, and were excluded from the final analysis. The remaining 95 patients (105 knees) successfully received Naton robot-assisted surgery, and no related complications occurred. The prosthesis size was consistent with the preoperative plan in 101 knees (96.2%) on the femur side, 100 knees (95.2%) on the tibia side, and 97 knees (92.4%) on both femur and tibia sides. The prosthesis size was inconsistent in 3 cases (2.86%) on the femur side alone, 4 cases (3.81%) on the tibial side alone, and 1 case (0.95%) on both femur and tibial sides. Among the prostheses with different models, the flexion and extension gaps were less than 0.5 mm in 3 knees, the flexion gap was less than 0.5 mm and the extension gap was more than 2.0 mm in 3 knees, and the flexion gap was more than 2.0 mm and the extension gap was less than 0.5 mm in 2 knees.
CONCLUSION
The accuracy of prosthesis size selection for Naton robot-assisted medial unicondylar knee arthroplasty is relatively high.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Female
;
Male
;
Middle Aged
;
Aged
;
Knee Prosthesis
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Prosthesis Design
;
Knee Joint/surgery*
;
Osteoarthritis, Knee/surgery*
;
Range of Motion, Articular
4.Effect of autologous blood transfusion device on preventing blood loss in primary total knee arthroplasty using comprehensive hemostatic methods.
Yang LI ; Bang Guo LI ; Ran ZHAO ; Hua TIAN ; Ke ZHANG
Journal of Peking University(Health Sciences) 2018;50(4):651-656
OBJECTIVE:
To analyze the conventional application of using comprehensive hemostatic methods during the perioperative period, and the effect of autologous blood transfusion (ABT) device compared with non-negative pressure drainage on preventing blood loss and allogenic blood transfusion after primary total knee arthroplasty (TKA).
METHODS:
A total of 131 patients (131 knees) with severe knee osteoarthritis who underwent unilateral primary TKA by the same surgeon in Peking University Third Hospital from June 2014 to June 2015 were enrolled in this study. The patients were divided into ABT group (64 patients) and control group (67 patients). ABT devices were used for drainage and blood transfusion in the ABT group while the control group used the non-negative pressure drainage only. The results of the drainage fluid volume, the decrease of hemoglobin, the total blood loss, the hidden blood loss and blood transfusion after TKA were compared between the two groups.
RESULTS:
The drainage fluid volume in ABT group was significantly higher than that in control group [515 mL (80-1 610 mL) vs. 260 mL (40-670 mL), P<0.001]. The autologous blood transfusion in ABT group was 245 mL (60-1 070 mL). There were no significant differences between the two groups in the value of hemoglobin decrease 1 day after surgery (P=0.340) and 3 days after surgery (P=0.524). There were no significant differences in the total blood loss (P=0.101) and the hidden blood loss (P=0.062) between the two groups either. There were 9 patients in the 131 patients who received allogeneic blood transfusion, of whom 5 in the ABT group (5/64, the blood transfusion rate was 7.8%) and 4 in the control group (4/67, the blood transfusion rate was 6.0%), and no significant differences in the blood transfusion rate between the two groups (P=0.943).
CONCLUSION
With the conventional application of using comprehensive hemostatic methods during perioperative period, the ABT device did not show the effective result of controlling postoperative blood loss and failed to reduce the rate of allogeneic blood transfusion in patients with unilateral primary TKA. However, the ABT device could increase the drainage fluid volume and improve the patient's hospitalization expenses. Therefore, there is no need for routine application of ABT device in unilateral primary TKA.
Arthroplasty, Replacement, Knee
;
Blood Loss, Surgical/prevention & control*
;
Blood Transfusion
;
Blood Transfusion, Autologous/instrumentation*
;
Hemostatics
;
Humans
5.Relationship between screw numbers and severity of tibial bone defect in primary total knee arthroplasty.
Chong ZHENG ; Yong-gang ZHOU ; Hai-yang MA ; Zhuo ZHANG ; Hua-hao FU ; Wen-ming WU ; Shang PIAO ; Yin-qiao DU ; Sen WANG
China Journal of Orthopaedics and Traumatology 2016;29(5):415-420
OBJECTIVETo summarize experience of using screws and cement to rebuild tibial bone defect in primary total knee arthroplasty (TKA) and to discuss the relationship between the number of required screws and the severity of tibial bone defects.
METHODSFrom July 2009 to May 2015, 34 patients (40 knees) with varus knees underwent TKA, and the screw and cement technique was used to rebuild medial tibia plateau during operation. There were 8 males (8 knees) and 26 females (32 knees), and the average age was (65.00 +/- 7.25) years old (ranged,55 to 82 years old). One to 6 screws were used in each case. Extension stems were used in 2 cases (4 and 5 screws was used respectively). The area percentages of the bone defects measured as defect area/tibia plateau area, depth of each defect, the number of screws needed in each case, were all used to determine the relationship between the number of screws and the area percentage in certain depth of bone defect by statistic methods, as well as the relationship between screw number and defect depth.
RESULTSAll the patients were followed up and the average duration was 24 months (ranged, 1 to 72 months). The average preoperative HSS score was 43.33 +/- 6.11 (ranged, 32 to 51 scores). Whereas the average postoperative HSS score was 92.15 +/- 4.64 (ranged,83 to 96 scores). The preoperative individual scores including pain, function, activity, nuscle strength, flexion deformity and stability were all improved compared with preoperation,and the differences were statistically significant. All the patients received normal alignment postoperatively, femoraltibial angle was improved from (167.00 +/- 6.39) degrees preoperatively to (175.00 +/- 2.69) degrees postoperatively, the tibial angle was improved from (78.09 +/- 4.51) degrees preoperatively to (88.75 +/- 1.24) degrees postoperatively. Both area percentage and depth of bone defect in a fitting Ologistic model had a significant statistical relationship with the screw number, and a rectangular coordinate system could be formed according to the relationship.
CONCLUSIONScrews and cement technique is a simple, safe and convenient method to rebuild tibial bone defects in primary TKA and its short-term and midterm effect are both reliable. During opera- tion, according to the rectangular coordinate system, the screw number needed in the operation can be inferred form th area and depth of tibia defect, which could have a guiding function in surgery.
Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Knee ; instrumentation ; methods ; Bone Screws ; utilization ; Female ; Fracture Fixation, Internal ; Humans ; Knee Injuries ; surgery ; Knee Joint ; surgery ; Male ; Middle Aged ; Tibia ; surgery
6.Are Western Knee Designs Dimensionally Correct for Korean Women? A Morphometric Study of Resected Femoral Surfaces during Primary Total Knee Arthroplasty.
Jun Bae KIM ; Suk Joo LYU ; Hyung Wook KANG
Clinics in Orthopedic Surgery 2016;8(3):254-261
BACKGROUND: The purpose of this study was to determine the shape of the distal femur of Korean women compared with the prostheses currently available in Korea. METHODS: Morphometric data (5 parameters) were measured in 356 resected femurs of Korean women undergoing primary total knee arthroplasty (TKA) utilizing the LCS knee implant (DePuy). The data were then compared with 5 additional contemporary TKA implant systems. RESULTS: Implant designs based on Caucasian population data do not ideally match the distal femoral morphology of Korean women. Overhang at the anterior mediolateral width was observed in 84.8% for the LCS while a gender-specific implant resulted in undercoverage of the bone in 86%. Posterior overhang was observed in up to 51.2%. Most implant designs have a narrower intercondylar notch than the morphologic data of Korean women. CONCLUSIONS: Since there is some difference between the shape of distal femur of Korean women and that of the implants, surgeons should have this in mind when selecting an implant for a patient. These data may also be used as a guideline for future prosthetic design options for Korean women population.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*instrumentation/statistics & numerical data
;
Asian Continental Ancestry Group/*statistics & numerical data
;
Cohort Studies
;
Female
;
Femur/*anatomy & histology/*surgery
;
Humans
;
Knee Joint/surgery
;
Middle Aged
;
Prosthesis Design
;
Republic of Korea
7.Case-control study on individual osteotomy instrument and conventional total knee arthroplasty for the treatment of knee osteoarthritis.
Hua-chen YU ; Yu ZHANG ; Paul WONG
China Journal of Orthopaedics and Traumatology 2016;29(6):513-516
OBJECTIVETo compare clinical efficacy of individual osteotomy instrument and total knee arthrolplasty (TKA) in treating patients with knee osteoarthritis.
METHODSFrom June 2014 to December 2014, 40 patients with unilateral knee osteoarthritis were randomly divided into two groups and 20 cases were in each group. One group (individual group) were treated with TKA with individual osteotomy instrument,including 5 males and 15 females with an average age of (67.3 ± 6.5) years old; 8 cases on the left side and 12 cases on the right side. Another group (conventional group) were treated with conventional TKA , including 6 males and 14 females with an average age of (66.8 ± 7.3) years old; 9 cases on the left side and 11 cases on the right side. Operative time, blood loss, postoperative HSS score at 6 months, and changes of mechanical alignment before and after operation were analyzed.
RESULTSOperative time in individual group was (79.3 ± 4.7) min, and (83.5 ± 3.2) min in conventional group; blood loss in individual group was (287.1 ± 24.9) ml and (363.4 ± 47.2) ml in conventional group, there were statistical differences between two groups in these two items. There was no significant difference in postoperative HSS score at 6 months between individual group (84.8 ± 3.2) and conventional group (84.2 ± 2.5). Postoperative limb alignment in individual group was (2.8 ± 0.6)°, and (2.8 ± 0.6)° in conventional group, with no significant difference between two groups.
CONCLUSIONTKA with individual osteotomy instrument could reduce operative time and blood loss, but there was no differences in knee function, changes of mechanical alignment compared with TKA.
Adult ; Aged ; Arthroplasty, Replacement, Knee ; methods ; Case-Control Studies ; Female ; Humans ; Knee Joint ; surgery ; Male ; Operative Time ; Osteoarthritis, Knee ; surgery ; Osteotomy ; instrumentation ; methods ; Treatment Outcome
8.Does Limited Tourniquet Usage in Primary Total Knee Arthroplasty Result in Better Functional Outcomes?
Gurpal SINGH ; Fucai HAN ; Ratnakar Rao KAKI ; Liang SHEN ; Saminathan Suresh NATHAN
Annals of the Academy of Medicine, Singapore 2015;44(8):302-306
Aged
;
Arthroplasty, Replacement, Knee
;
adverse effects
;
methods
;
Case-Control Studies
;
Female
;
Follow-Up Studies
;
Humans
;
Incidence
;
Intraoperative Care
;
instrumentation
;
methods
;
Male
;
Middle Aged
;
Osteoarthritis, Knee
;
surgery
;
Postoperative Complications
;
diagnosis
;
epidemiology
;
etiology
;
prevention & control
;
Recovery of Function
;
Risk Assessment
;
Singapore
;
epidemiology
;
Tourniquets
;
adverse effects
;
Treatment Outcome
9.A Novel Non-Invasive Adjuvant Biomechanical Treatment for Patients with Altered Rehabilitation after Total Knee Arthroplasty: Results of a Pilot Investigation.
Lee YAARI ; Yona KOSASHVILI ; Ganit SEGAL ; Shai SHEMESH ; Steven VELKES ; Amit MOR ; Ronen DEBI ; Benjamin BERNFELD ; Avi ELBAZ
Clinics in Orthopedic Surgery 2015;7(2):191-198
BACKGROUND: Many factors contribute to suboptimal results after total knee arthroplasty (TKA) but little is known regarding the value of postsurgical rehabilitation after TKA. We examined the effects of an enhanced closed kinematic chain exercises program (AposTherapy) on gait patterns and clinical outcomes among patients with a lack of progress in their postsurgical rehabilitation. METHODS: Twenty-two patients were prospectively followed during the study. Gait spatiotemporal parameters were measured at the initial evaluation, after 15 minutes of therapy, and after 3 months of therapy. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the short form (SF) 36 health survey were completed by patients before treatment and after 3 months of treatment. RESULTS: The WOMAC and SF-36 scores improved significantly after 3 months of treatment. Gait velocity, single limb support, and step length of the operated leg improved significantly even after a single 15 minutes treatment. Normal gait velocity was observed in 36% of patients after 3 months of treatment. CONCLUSIONS: A physiotherapy program that included enhanced closed kinematic chain biomechanical therapy was beneficial for patients who experienced a suboptimal rehabilitation course after TKA.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*rehabilitation
;
Biomechanical Phenomena
;
Female
;
Humans
;
Male
;
Middle Aged
;
Physical Therapy Modalities/*instrumentation
;
Pilot Projects
;
Postoperative Complications/*therapy
;
Prospective Studies
;
Shoes
;
Treatment Failure
10.Total Knee Replacement Arthroplasty with Buechel and Pappas Knee: Minimum 2-Year Follow-up.
Kyoung Ho MOON ; Seung Hyun HONG ; Taek Ho HONG
Clinics in Orthopedic Surgery 2015;7(1):62-68
BACKGROUND: Clinical and radiologic evaluation and analyses of the surgeries using Buechel and Pappas (B-P) knee implants. METHODS: The study was conducted on 60 patients who underwent 94 total knee replacement arthroplasty with B-P knee implants from May 2009 to December 2010. The results were compared to the results of 41 patients who underwent 60 knee joint surgeries using NexGen-LPS implants from January 2008 to August 2009. RESULTS: The American Knee Society score of the B-P knee group increased from an average of 66.9 (clinical score) and 65.5 (functional score) to 93.4 and 90.3, respectively; while those for the NexGen-LPS group increased from an average of 68.8 (clinical score) and 62.4 (functional score) to 86.3 and 76, respectively. The average ranges of motion of the B-P knee group and the NexGen-LPS group were 119.1degrees and 114.8degrees, respectively, before surgery and improved to 121.0degrees and 123.0degrees at final follow-up after the surgery. The visual analogue scale scores for the B-P knee group and the NexGen-LPS group improved from 4.7 and 4.6 to 1.4 and 1.8, respectively. The flexion contracture also improved from 5.1degrees and 6.3degrees to 0.64degrees and 1.72degrees. The tibio-femoral angle for the B-P knee group and the NexGen-LPS group also improved greatly after the surgery, from varus 0.34degrees and 0.73degrees each to valgus 6.7degrees and 6.9degrees, respectively. CONCLUSIONS: The evaluation of more than 2 years of total knee replacement arthroplasty using B-P knee implants showed good results. B-P knee implants showed a relatively higher degree of satisfaction in clinical knee score and less intraoperative bone mass removal than NexGen-LPS implants.
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/*instrumentation
;
Female
;
Follow-Up Studies
;
Humans
;
Knee Joint/radiography/*surgery
;
*Knee Prosthesis
;
Male
;
Middle Aged
;
Osteoarthritis, Knee/radiography/*surgery

Result Analysis