1.Effectiveness of combined anteversion angle technique in total hip arthroplasty for treatment of ankylosing spondylitis affecting hip joint.
Yuan WANG ; Fang PEI ; Feng WAN ; Zexuan WANG ; Xiaolei LIU ; Kaijin GUO
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):15-21
OBJECTIVE:
To explore the effectiveness of the combined anteversion angle technique in total hip arthroplasty (THA) for treating ankylosing spondylitis (AS) affecting the hip joint.
METHODS:
A retrospective analysis was conducted on the clinical data of 73 patients with AS affecting the hip joint who underwent THA between August 2018 and August 2021. According to whether the combined anteversion angle technique was used in THA, the patients were divided into study group (37 cases, combined anteversion angle technique was used in THA) and control group (36 cases, traditional THA). There was no significant difference in baseline data such as gender, age, body mass index, disease duration, preoperative Harris score, range of motion (ROM), acetabular anteversion angle, acetabular abduction angle, femoral anteversion angle, and combined anteversion angle between the two groups ( P>0.05). The operation time, hospital stay, and complications of the two groups were recorded and compared. The Harris score and hip ROM were compared between the two groups before operation, at 1, 3, 6, 12 months after operation, and at last follow-up. The acetabular component anteversion angle, femoral component anteversion angle, acetabular component abduction angle, and component combined anteversion angle were measured postoperatively.
RESULTS:
The operation time in the study group was significantly shorter than that in the control group ( P<0.05), and there was no significant difference in hospital stay between the two groups ( P>0.05). There was no intraoperative complication such as acetabular and proximal femoral fractures, neurovascular injuries in both groups, and the incisions healed by first intention. All patients were followed up 2-3 years, with an average of 2.4 years; there was no significant difference in the follow-up time between the two groups ( P>0.05). During the follow-up period, there was no complication such as hip dislocation, wound infection, delayed wound healing, deep venous thrombosis, and hip dislocation in both groups. The hip Harris score and ROM of the two groups gradually increased with time after operation, and the differences were significant when compared with those before operation ( P<0.05); the above two indicators of the study group were significantly better than those of the control group at each time point after operation ( P<0.05). Extensive bone ingrowth on the surface of the components could be observed in the anteroposterior X-ray films of the hip joint of the two groups at 12 months after operation, and the acetabular components was stable without femoral stem subsidence, osteolysis around the components, and heterotopic ossification. At last follow-up, the acetabular component anteversion angle, femoral component anteversion angle, and component combined anteversion angle in the study group were significantly superior to those in the control group ( P<0.05), except that there was no significant difference in the acetabular component abduction angle between the two groups ( P>0.05).
CONCLUSION
For patients with AS affecting the hip joint, the use of the combined anteversion angle technique during THA effectively promotes the recovery of hip joint function and enhances the postoperative quality of life of patients when compared to traditional THA.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Dislocation/surgery*
;
Spondylitis, Ankylosing/surgery*
;
Retrospective Studies
;
Quality of Life
;
Treatment Outcome
;
Hip Joint/surgery*
;
Hip Prosthesis
3.Comparison of filling ratio, alignment, and stability between ABG Ⅱ short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur.
Xianchao BAO ; Mingyang LI ; Limin WU ; Shenghu JIANG ; Bin SHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):641-646
OBJECTIVE:
Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem.
METHODS:
Among patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant ( P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up ( P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software.
RESULTS:
X-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group ( P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group ( P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group ( P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant ( P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group ( P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant ( P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups ( P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group ( P<0.05).
CONCLUSION
Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Femur/surgery*
;
Hip Prosthesis
;
Lower Extremity/surgery*
;
Prosthesis Design
;
Retrospective Studies
5.Effect of posture on total hip arthroplasty through direct anterior approach.
Wang-Xin LIU ; Tie-Jun ZHAO ; Hui-Hui SUN ; Zhi-Cheng PAN ; Jing SHEN ; Wei-Feng JI
China Journal of Orthopaedics and Traumatology 2023;36(7):628-634
OBJECTIVE:
To investigate the effect of different postures on direct anterior approach(DAA) total hip arthroplasty.
METHODS:
Total of 94 patients who underwent DAA total hip arthroplasty from July 2016 to June 2020 were retrospectively analyzed. They were divided into two groups according to different positions during the operation, including 45 cases in lateral position and 49 cases in supine position (with the aid of stent). The general data such as gender, affected limb, body mass index(BMI), incision length, operation time, intraoperative bleeding volume, drainage volume 24 hours after operation, hemoglobin difference before and after operation, first landing time after operation, postoperative hospitalization time, postoperative complications, visual analogue scale(VAS) at 1 day, 1, 2 weeks, 1, 3 and 6 months after operation, Harris score at 1, 2 weeks, 1, 3 and 6 months after operation were observed and compared between the two groups.
RESULTS:
Patients in both groups were followed up for 6 to 12 months with an average of (8.31±2.22) months. There was no significant difference between two groups in gender, affected limb, age, height, weight, body mass index(BMI), preoperative VAS score and preoperative Harris score(P>0.05). The incision length, operation time, intraoperative bleeding volume, 24-hour drainage volume, hemoglobin difference before and after operation, first time to the ground and postoperative hospitalization time of patients in supine position (assisted by stent) group were all better than those in lateral position group(P<0.05);There was no significant difference in the number of blood transfusions during and after operation(P=0.550). There was no significant difference in anteversion angle and abduction angle in the supine position(with the aid of stent) group during and after operation (P=0.825, P=0.066);There was significant difference in anteversion angle and abduction angle in the lateral position group during and after operation(P<0.05). VAS of patients in supine position (assisted by stent) group were lower than those in lateral position group at 1 day, 1, 2 weeks and 1 month after operation(P<0.05), and there was no statistical difference between two groups at 3 and 6 months after operation(P>0.05). Harris scores of patients in supine position(assisted by stent) group were higher than those in lateral position group at 1 week, 1 month and 3 months after operation(P<0.05), and there was no significant difference between two groups at 6 months after operation(P>0.05).
CONCLUSION
Compared with the lateral position, the supine position DAA total hip arthroplasty has the advantages of small incision, short operation time, less bleeding, early landing time, short hospitalization time, and small intraoperative acetabular cup position judgment error. It has the advantage of fast postoperative recovery, but the recovery of hip joint function is the same after 6 months.
Humans
;
Arthroplasty, Replacement, Hip
;
Retrospective Studies
;
Antiviral Agents
;
Treatment Outcome
;
Posture
6.A medium term analysis on of therapeutic effects of bio-lengthend stem hemiarthroplasty in the treatment of unstable osteoporotic intertrochanteric fractures in elderly patients.
Jian-Li FANG ; Hua-Jie LIN ; Hong-Kan LOU ; Yong JIN
China Journal of Orthopaedics and Traumatology 2023;36(7):658-661
OBJECTIVE:
To retrospectively study medium term follow up outcomes effects of effect of bio-lengthend stem hemiarthroplasty in the treatment of unstable osteoporotic intertrochanteric fractures in elderly patients.
METHODS:
Total of 32 elderly patients with the osteoporotic intertrochanteric fractures were treated with bio-lengthend stem hemiarthroplasty from Jan. 2016 to Jan. 2019 including 14 males and 22 females, aged from 85 to 95 years old with an average of (89.5±4.5) years old. According to classification of Evans, there were 12 cases with type Ⅲ, 11 with type Ⅳ and 9 with type Ⅳ. The time from injury to operation ranged from 0.5 to 9 days with an average of (4.5±3.9) days. The operation time, blood loss and postoperative complications were analyzed. Functional outcome was assessed by Parker Palmer mobility score(PPMS) and Harris hip score.
RESULTS:
Four patients died within one year after operation, and the mortality was 12.5%. The follow up time for the rest 28 patients ranged from 24 to 60 months with an average of (28.5±4.5) months. The mean operative time was (54.2±22.5) min;the mean blood loss (hidden blood loss+obvious blood loss) was (450±140) ml;the first weight bearing was (3.35±1.35) days. No perioperative death occurred. PPMS were(6.63±1.25), (6.94±1.18), (7.11±0.83), (7.32±1.11) and Harris scores were(67.85±6.19), (71.42±5.57), (73.41±5.62), (77.32±5.24) respectively at 1, 3, 6 months and the final follow-up after operation. There were no significant difference in PPMS and Harris score at 1, 3, 6 months after operation and the final follow-up(P>0.05). There were no complications such as joint dislocation and prosthesis loosening occure at the final follow-up.
CONCLUSION
On the premise of strictly mastering the case selection criteria, the bio-lengthend stem hemiarthroplasty in the treatment of unstable osteoporotic intertrochanteric fractures in elderly patients has a satisfied medium term follow-up outcomes. It can restore hip function in the early stage and improve the quality of life of patients.
Male
;
Female
;
Humans
;
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip
;
Hemiarthroplasty
;
Quality of Life
;
Retrospective Studies
;
Treatment Outcome
;
Hip Fractures/surgery*
;
Osteoporotic Fractures/surgery*
7.Primary repair for concurrent bilateral intertrochanteric fracture and femoral head necrosis with prolonged shank biologic total hip replacement: A case report and surgical techniques.
Yuan-Jie LIU ; Jun-Tan LI ; Yu-Yang GAO ; Pei-Yan GUO ; Tian-Xu DOU ; Xu LI
Chinese Journal of Traumatology 2023;26(3):183-186
For the treatment of an intertrochanteric fracture combined with femoral head necrosis in middle-age patients, it has been controversial whether to perform fracture reduction and fixation first then total hip replacement, or direct total hip replacement. We present a rare case of 53-year-old male patient suffered from bilateral intertrochanteric fracture caused by a road traffic injury. The patient had a history of femoral head necrosis for eight years, and the Harris score was 30. We performed total hip replacement with prolonged biologic shank prostheses for primary repair. One year after the surgery, nearly full range of motion was achieved without instability (active flexion angle of 110°, extension angle of 20°, adduction angle of 40°, abduction angle of 40°, internal rotation angle of 25°, and external rotation angle of 40°). The Harris score was 85. For the middle-aged patient with unstable intertrochanteric fractures and osteonecrosis of the femoral head, we can choose primary repair for concurrent bilateral intertrochanteric fracture and femoral head necrosis with prolonged shank biologic total hip replacement.
Male
;
Middle Aged
;
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Femur Head/surgery*
;
Femur Head Necrosis/surgery*
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/surgery*
;
Biological Products
;
Treatment Outcome
;
Retrospective Studies
8.Clinical and patient reported outcomes of Vitamin E diffused highly cross-linked polyethylene liner versus moderately cross linked polyethylene liner in total hip arthroplasty: A meta-analysis
Diovince S. Tan ; Byron S. Angeles
Journal of Medicine University of Santo Tomas 2023;7(2):1288-1301
Introduction:
In the modern era of Medicine, total hip arthroplasty (THA) is found to last longer than ever before due to the fact that there has been improved bearing surfaces and materials available. Despite these modern approaches, failure caused by polyethylene wear, aseptic loosening, instability and mispositioning and even infection could affect THA survival. In the course of addressing anti-wear characteristics of the conventional polyethylene surface various approaches have been made. To date, there are very limited studies done in which polyethylene liner is better.
General Objective:
To compare the effects of vitamin E diffused highly cross-linked polyethylene liner versus moderately cross-linked polyethylene liner in THA.
Methodology:
Meta-analysis research design was used in this study. The primary investigators conducted a comprehensive literature search from Medline, Cochrane Library, PubMed, Elsevier, Google Scholar, Embase and ClinicalTrial.gov as electronic database. All randomized controlled trials comparing the effects of vitamin E diffused highly cross-linked polyethylene liner versus moderately cross-linked polyethylene liner in THA were included in the review.
Conclusions
The investigation disclosed no statistical significance between moderately cross-linked polyethylene liner and vitamin E diffused highly cross-linked polyethylene liner in terms of migration, head penetration and wear on mediolateral, longitudinal and anteroposterior axes after 2 and 5 years of undergoing THA. Moreover, the data pertaining to patient reported outcomes and clinical outcomes measure also indicated no statistical significance between moderately cross-linked polyethylene liner and vitamin E diffused highly cross-linked polyethylene liner. This indicates that vitamin E diffused highly cross-linked polyethylene liner is comparable with the conventional moderately cross-linked polyethylene liner. Vitamin E-infused highly cross-linked polyethylene ( VEPE) showed an almost similar stability with regard to the wear rates and the component showed similar stability with that of moderately cross-linked polyethylene liner.
Arthroplasty, Replacement, Hip
9.Comparison of effect between internal fixation and total hip replacement in the treatment of displaced femoral neck fracture in middle age patients.
Zhi-Yuan WANG ; Fan LUO ; Ying-Qi ZHANG ; Jia LIU ; Xiao-Zhong ZHU ; Zhi-Tao RAO
China Journal of Orthopaedics and Traumatology 2023;36(3):232-235
OBJECTIVE:
To analyze and compare the clinical efficacy of internal fixation and total hip replacement in the treatment of displaced femoral neck fracture from 55 to 65 years.
METHODS:
From September 2016 to August 2020, 86 patients with Garden type Ⅲ or Ⅳ femoral neck fracture were divided into two groups according to different surgical methods. Among them, 38 patients were treated with lag screws for internal fixation, there were 26 males and 12 females, aged 55 to 64 years old with an average of(60.2±3.1) years;the other 48 patients were treated with total hip replacement, including 28 males and 20 females, aged from 57 to 65 years old with an average of(61.3±3.8) years. The time from injury to operation ranged from 1 to 3 days. The reoperation rate, incidence of deep infection, Harris score of hip joint function, visual analogue scale(VAS) of pain and patients reported outcome scores(European five-dimensional Health Questionnaire, EQ-5D) were compared between two groups.
RESULTS:
All patients were followed up for 24 to 54 months with an average of (35.8±10.3) months. There was significant difference in reoperation rate between two groups (P<0.05). There was no significant difference on the incidence of deep infection, hip Harris score and VAS between two groups(P>0.05) . The postoperative EQ-5D score of patients with internal fixation was lower than that of total hip replacement, and the difference was statistically significant(P<0.05).
CONCLUSION
Both the surgery of internal fixation and total hip replacement have similar effect in short-and medium term among the patients aged 55 to 65 years old. However, for the reoperation rate, the group of internal fixation was higher than that of total hip replacement. For the subjective functional score of patients, the group of internal fixation was lower than that of total hip replacement.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Hip/methods*
;
Treatment Outcome
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Reoperation
10.Interpretations of Management of Hip Fractures in Older Adults:Evidence-Based Clinical Practice Guideline dopted by AAOS 2021.
China Journal of Orthopaedics and Traumatology 2023;36(3):279-283
American Academy of Orthopaedic Surgeons (AAOS) just released the up-to-date
Aged
;
Humans
;
Arthroplasty, Replacement, Hip
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Hip Fractures/surgery*
;
Orthopedic Surgeons
;
Treatment Outcome
;
United States
;
Practice Guidelines as Topic


Result Analysis