1.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
2.Analgesic effect of "cocktail" analgesia containing high-dose compound betamethasone after revision hip arthroplasty and the use of opioid drugs.
Ning YANG ; Wulamu WUHUZI ; Xiaobin GUO ; Yicheng LI ; Xiaogang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):314-319
OBJECTIVE:
To investigate the analgesic effect of locally injecting a "cocktail" analgesia containing a high-dose compound betamethasone during revision hip arthroplasty, and also to study the usage of opioid drugs.
METHODS:
A retrospective analysis was conducted on the clinical data of 180 patients who underwent revision hip arthroplasty due to aseptic loosening of the hip prosthesis between January 2015 and December 2021. Among them, 95 patients received intraoperative injection of "cocktail" analgesia containing high-dose compound betamethasone (group A), and 85 patients received intraoperative injection of traditional "cocktail" analgesia (group B). There was no significant difference in baseline data such as gender, age, body mass index, presence or absence of diabetes mellitus between the two groups ( P>0.05). The hospital stay, use of opioid drugs within 72 hours, and the incidence of adverse reactions within 72 hours after operation [including nausea and vomiting, insomnia, deep venous thrombosis (DVT), infection, etc.] were recorded and compared between the two groups. The pain relief of patients was evaluated using the static and dynamic visual analogue scale (VAS) scores at 12, 24, 48, and 72 hours after operation. The incidence of complications (including prosthesis re-loosening, hip joint dislocation, hip joint stiffness, limping, chronic pain, etc.) at 2 years after operation was recorded, and the Harris Hip Score (HHS) was used to evaluate the function at 2 years after operation.
RESULTS:
In group A, the utilization rate of opioid drugs within 72 hours after operation was significantly lower than that in group B ( P<0.05). However, there was no significant difference between the two groups in terms of hospital stay, as well as the incidence of adverse reactions such as nausea and vomiting, insomnia, DVT, and infection within 72 hours after operation ( P>0.05). The VAS scores of both groups decreased with time, and the differences between different time points were significant ( P<0.05). The static and dynamic VAS scores of group A were significantly lower than those of group B at 12, 24, and 48 hours after operation ( P<0.05), but there was no significant difference in static and dynamic VAS scores between the two groups at 72 hours after operation ( P>0.05). All patients in both groups were followed up 2-8 years, with an average of 5.73 years. At 2 years after operation, no significant difference was found between the two groups in the incidence of complications and HHS score ( P>0.05).
CONCLUSION
"Cocktail" analgesia containing a high-dose compound betamethasone for early analgesia after revision hip arthroplasty can effectively reduce postoperative pain and the use of opioid drugs, but will not increase the incidence of infection and DVT after operation.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Betamethasone/therapeutic use*
;
Retrospective Studies
;
Male
;
Female
;
Analgesics, Opioid/administration & dosage*
;
Pain, Postoperative/prevention & control*
;
Middle Aged
;
Reoperation
;
Aged
;
Analgesia/methods*
;
Adult
;
Pain Measurement
;
Pain Management/methods*
;
Prosthesis Failure
;
Hip Prosthesis
3.Feasibility study on measuring anteversion angle of acetabular prosthesis after total hip arthroplasty using arbitrary point method.
Bowen LI ; Longyuan LI ; Heng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):420-424
OBJECTIVE:
To explore the reliability and accuracy of the arbitrary point method for measuring the anteversion angle of acetabular prosthesis after total hip arthroplasty (THA) based on pelvic X-ray films.
METHODS:
The clinical data of 23 patients (25 hips) who underwent THA between December 2018 and September 2023 and met the selection criteria were retrospectively analyzed. Among them, there were 16 males and 7 females, with an average age of 57.6 years (range, 34-81 years); 13 hips had THA on the left side and 12 on the right side. There were 19 cases (21 hips) of osteonecrosis of the femoral head, 2 cases (2 hips) of femoral neck fractures, 1 case (1 hip) of developmental dysplasia of the hip, and 1 case (1 hip) of osteoarthritis. After THA, all patients underwent X-ray examination and CT scan. Three physicians measured the anteversion angle of acetabular prosthesis using the arbitrary point method and the CT measurement method respectively, and repeated the measurements three times. The results of the two measurement methods were compared, and the intraclass correlation coefficient (ICC) was employed to assess the reproducibility of the methods.
RESULTS:
The anteversion angles of acetabular prosthesis were (15.87±7.73)° measured by the arbitrary point method, and (15.31±7.89)° measured by CT measurement method. There was no significant difference between the two methods ( t=1.515, P=0.143). The ICC of the measurement results by the arbitrary point method for the three physicians were 0.97 ( P<0.001), 0.96 ( P<0.001), and 0.96 ( P<0.001), respectively; and the ICC of the measurement results by CT method were 0.93 ( P<0.001), 0.93 ( P<0.001), and 0.94 ( P<0.001), respectively.
CONCLUSION
The arbitrary point method for measuring the anteversion angle of acetabular prosthesis after THA based on pelvic X-ray film is easy to operate, accurate, and has high reproducibility.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Hip Prosthesis
;
Acetabulum/surgery*
;
Aged, 80 and over
;
Retrospective Studies
;
Adult
;
Reproducibility of Results
;
Feasibility Studies
;
Tomography, X-Ray Computed
4.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
5.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
6.Clinical features and surgical treatment strategies of hip arthroplasty for unhealed old femoral intertrochanteric fractures.
Qing XIA ; Chuan-Wen LIU ; Yu-Cheng XIA ; Hui-Yang WANG ; Jin-Quan GUO
China Journal of Orthopaedics and Traumatology 2025;38(2):188-194
OBJECTIVE:
To explore the surgical method and clinical efficacy of hip arthroplasty in the treatment of old non-union femoral intertrochanteric fractures.
METHODS:
Fifteen unoperated patients suffering from old non-union femoral intertrochanteric fractures from Feburary 2013 to Feburary 2023 were treated with hip arthroplasty including 9 males and 6 females, aged 71 to 82 years old. Eleven cases detected deep venous thrombosis(DVT), 9 cases received lower vena cava filter implantation. The operation time, intraoperative blood loss, intraoperative and postoperative blood transfusion, postoperative hemoglobin content, procedure-related complications, and the range of motion of hip flexion, abduction motion were recorded. The degree of hip pain was evaluated using a visual analogue scale(VAS). The hip Harris scores were used to evaluated the clinical efficacy.
RESULTS:
All patients were followed up for 3 to 12 months. The intraoperative blood loss was 200 to 400 ml, intraoperative blood transfusion was 0 to 400 ml, and the operation time was 40 to 90 min. All 15 patients had different degrees of anemia after surgery, the 3 days postoperative hemoglobin was 72 to 97 g·L-1, and the postoperative transfusion volume was 0 to 400 ml. All patients had no periprosthetic infection, poor incision healing, lower limb deep vein thrombosis, and cerebral infarction. One case occurred in the early postoperative period, which disappeared from 4 to 5 days after operation, and there was no further revision at the last follow-up. The VAS was 6 to 7 points before operation and 2 to 4 points at latest follow-up;the hip Harris score was 2 to 13 points before operation and 73 to 84 points at latest follow-up.
CONCLUSION
The unoperated patients of old non-union femoral intertrochanteric fractures had significant clinical and imaging characteristics. Hip arthroplasty combined with or without femoral calcar reconstruction in the treatment of old non-union femoral intertrochanteric fractures had the advantages of relatively simple manipulation, rigid fixation, relatively safe operation, and relatively exact efficacy.
Humans
;
Male
;
Female
;
Aged
;
Hip Fractures/physiopathology*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
7.Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
Xiang ZHAO ; Xiang-Hua WANG ; Rong-Xin HE ; Xun-Zi CAI ; Li-Dong WU ; Hao-Bo WU ; Shi-Gui YAN
China Journal of Orthopaedics and Traumatology 2025;38(10):987-993
OBJECTIVE:
To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:
A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:
All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION
The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Aged, 80 and over
;
Workflow
;
Treatment Outcome
8.Comparison of clinical efficacy between robotic-assisted total hip arthroplasty and traditional total hip arthroplasty.
Hao YANG ; Wen-Han FU ; Ming LU ; Zong-Sheng YIN
China Journal of Orthopaedics and Traumatology 2025;38(10):1001-1008
OBJECTIVE:
To explore and analyze the clinical efficacy of robotic-assisted versus traditional total hip arthroplasty.
METHODS:
A total of 186 patients with end-stage hip joint diseases treated from January 2023 to April 2025 were selected as the research subjects. Among them, 85 patients were screened out using propensity score matching and divided into two groups according to different treatment methods:manual total hip arthroplasty (mTHA) group (mTHA group) and robotic-assisted total hip arthroplasty (rTHA) group (rTHA group). In mTHA group, there were 50 patients, including 18 males and 32 females, age ranged from 37 to 78 years old with a mean of (60.12±10.93) years old;body mass index (BMI) ranged from 16.6 to 32.0 kg·m-2 with an average of (23.98±3.78) kg·m-2;27 cases involved the left hip, and 23 cases involved the right hip. In the rTHA group, there were 35 patients, including 14 males and 21 females, age ranged from 31 to 76 years old with an average of (57.14±12.18) years old;the BMI ranged from 17.1 to 33.0 kg·m-2 with a mean of (22.76±2.54) kg·m-2;13 cases involved the left hip, and 22 cases involved the right hip. The following parameters were analyzed and compared between the two groups:acetabular anteversion angle, acetabular abduction angle, difference in combined offset, difference in lower limb length, proportion of acetabula located in the Lewinnek safe zone after surgery, operation time, visual analogue scale (VAS) score, Western Ontario and McMaster Universities osteoarthritis index (WOMAC) score, and Harris hip score (HHS).
RESULTS:
All patients were followed up for 3 to 9 months, with an average of (6.8±1.3) months. In rTHA group and mTHA group, the abduction angles were (40.73±4.62)° and (40.95±4.71)° respectively;the differences in combined offset were (0.42±0.28) mm and (0.60±0.23) mm respectively;the WOMAC scores were(20.9±5.4) and (20.2±4.6) respectively;and the VAS were (1.1±1.0) and (1.0±0.8) respectively. There were no statistically significant differences in the above indicators between the two groups (P>0.05). However, statistically significant differences were observed between the two groups in the following aspects(P<0.05):the differences in lower limb length were (3.17±0.15) mm and (5.28±0.47) mm respectively;the postoperative acetabular anteversion angles were(22.84±2.83)° and (25.72±3.29)° respectively;the HHS were (80.7±5.5) and (74.8±6.3) respectively;and the operation times were (148.20±46.82) minutes and (81.84±18.76) minutes respectively.
CONCLUSION
Robot-assisted total hip arthroplasty demonstrates superior implant accuracy and improved early functional recovery compared with traditional manual THA. Nevertheless, it is associated with significantly longer operation time. Long-term prosthesis survival rate requires further follow-up verification.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Hip/methods*
;
Middle Aged
;
Aged
;
Adult
;
Robotic Surgical Procedures/methods*
;
Treatment Outcome
9.Short-to-medium-term clinical efficacy of total hip arthroplasty with Pinnacle ES constrained liner in the treatment of femoral neck fractures associated with lower limb neuromuscular disorders.
Can-Feng WANG ; Xiao-Qing WANG ; Lei HAN ; Yun-Gen HU ; Tuo WANG
China Journal of Orthopaedics and Traumatology 2025;38(11):1151-1155
OBJECTIVE:
To investigate the short-to-medium-term clinical efficacy of total hip arthroplasty(THA) with Pinnacle ES constrained liner in the treatment of femoral neck fractures(FNF) associated with lower limb neuromuscular disorders.
METHODS:
A retrospective analysis was conducted on 16 patients who underwent primary THA using Pinnacle ES constrained liner for FNF with lower limb neuromuscular disorders and had complete follow-up data, treated between January 2020 and January 2023. There were 7 males and 9 females, with a mean age of (68.42±3.58) years old ranging from 61 to 75 years old. Among them, 10 cases had left-sided fractures and 6 had right-sided fractures;based on the Garden classification, 11 cases were type Ⅲ and 5 cases were type Ⅳ. The affected limbs were complicated with sequelae of poliomyelitis (2 cases), Parkinson's disease (2 cases), and sequelae of cerebral infarction (12 cases). All operations were performed via a posterolateral approach. Prosthesis position was evaluated using imaging data. Hip function was assessed by the Harris hip score(HHS) and Merle D'Aubigne hip score. During the follow-up period, the occurrence of complications such as prosthetic dislocation, loosening, and infection was recorded.
RESULTS:
One patient died of advanced tumor 2 years after surgery, and the remaining 15 patients were followed up for 24 to 64 months with a mean of (34.8±5.5) months. The operation time ranged from 50 to 90 minutes with a mean of (75.56±8.15) minutes, and the blood loss ranged from 150 to 200 ml with a mean of (170.32±12.56) ml. All patients achieved primary wound healing after surgery. Intraoperatively, femoral calcar splitting occurred in 2 cases, which were treated with titanium cable binding;no neurovascular injuries were observed in any case. The mean HHS increased from (18.95±2.25) preoperatively to (88.02±2.42) at the last follow-up, and the mean Merle D'Aubigne Score increased from (3.05±0.06) preoperatively to (16.65±0.93) at the last follow-up. Postoperative follow-up X-rays showed good prosthetic position, and no complications such as dislocation, prosthetic loosening, periprosthetic fracture, or deep infection occurred during the follow-up period.
CONCLUSION
Total hip arthroplasty with Pinnacle ES constrained liner is effective in the treatment of femoral neck fractures associated with lower limb neuromuscular disorders. It can significantly improve hip function, reduce the postoperative prosthetic dislocation rate, provide good initial stability, and achieve satisfactory short-to-medium-term clinical efficacy.
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Hip/methods*
;
Femoral Neck Fractures/complications*
;
Retrospective Studies
;
Neuromuscular Diseases/surgery*
;
Lower Extremity
;
Treatment Outcome
10.Sparing piriformis and internus repairing externus vs. other conventional approaches for hip hemiarthroplasty: A report of early outcomes from a single UK trauma unit.
Michael APOSTOLIDES ; William THOMAS ; Darren LEONG ; Bogdan ROBU ; Nimesh PATEL
Chinese Journal of Traumatology 2025;28(5):324-329
PURPOSE:
Over 30,000 hip hemiarthroplasties for neck of femur fractures are performed annually in the United Kingdom (UK). The national recommendation is via the lateral approach, to reduce the risk of dislocation, with the potential expense of reduced function and mobility post-operatively. Muscle-sparing approaches, such as SPAIRE (sparing piriformis and internus repairing externus), have been invented to address the issue of dislocation.
METHODS:
We performed a retrospective data collection at a single center with a high annual volume of hip hemiarthroplasties over 12 months. All patients who had hip hemiarthroplasty as their primary treatment were included. Patients who passed away and were non-ambulant before their surgery were excluded from the study. Our primary outcome was the dislocation rate and secondary outcomes were the time to mobilization after surgery and the duration of surgery. Statistical analysis was performed using XLSTAT software.
RESULTS:
We identified 194 cases, and these were divided into 3 groups based on the surgical approach: SPAIRE (n = 43), lateral (n = 97), and posterior (n = 54). Groups had similar demographics and a minimum 3-month follow-up after surgery. There were no dislocations in the SPAIRE group, whereas the dislocation rate for the other 2 groups was 2.5% in the lateral and 9.1% in the posterior groups at 6 months post-surgery. There was an earlier return to mobility in the SPAIRE (1.4 day) compared to the 2 other groups ( 2 days and 2.6 days). Average surgical times were very similar among all 3 groups (74 min vs. 79 min vs. 71 min).
CONCLUSION
The SPAIRE approach seems to be safe and provides a low risk of dislocation and good post-operative function for patients undergoing hip hemiarthroplasties.
Humans
;
Hemiarthroplasty/methods*
;
Retrospective Studies
;
Female
;
Male
;
Aged
;
United Kingdom
;
Femoral Neck Fractures/surgery*
;
Middle Aged
;
Treatment Outcome
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
;
Trauma Centers
;
Hip Dislocation/prevention & control*
;
Postoperative Complications/prevention & control*

Result Analysis
Print
Save
E-mail