1.Postoperative urinary retention following hip or knee arthroplasty under spinal anaesthesia with intrathecal morphine: a retrospective cohort study.
Elad DANA ; Oz BEN-ZUR ; Sara DICHTWALD ; Guy FEIGIN ; Noa BRIN ; Michael MARKUSHEVICH ; Brian FREDMAN ; Yaron Shraga BRIN
Singapore medical journal 2025;66(9):481-485
INTRODUCTION:
Postoperative urinary retention (POUR) frequently complicates the course of patients following hip and knee arthroplasty. Intrathecal morphine (ITM) was identified as a significant risk factor for POUR. The objective of this study was to investigate the incidence and risk factors for POUR in fast-track total joint arthroplasty (TJA) under spinal anaesthesia (SA) with ITM.
METHODS:
We conducted a retrospective study of our institutional joint registry of patients who underwent primary TJA under SA with ITM between October 2017 and May 2021. Preoperative (baseline demographics) and perioperative data were collected. The primary outcome was the incidence of POUR after 8 h or earlier, either due to lack of voiding or according to patient's complaints of bladder distension. Univariate and adjusted analyses were performed to identify predictors of POUR.
RESULTS:
Sixty-nine patients who underwent total knee arthroplasty (TKA) and 36 patients who underwent total hip arthroplasty (THA) under SA with ITM were included in the study. POUR requiring bladder catheterisation was diagnosed in 21% of patients. Independent predictors of POUR were age over 65 years and male gender.
CONCLUSIONS
SA with ITM for TJA is associated with high rates of POUR in males older than 65 years of age. Other previously identified risk factors such as intraoperative fluid administration or comorbidities may not be as influential.
Humans
;
Retrospective Studies
;
Male
;
Urinary Retention/epidemiology*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Anesthesia, Spinal/adverse effects*
;
Female
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Morphine/adverse effects*
;
Aged
;
Middle Aged
;
Risk Factors
;
Postoperative Complications/epidemiology*
;
Injections, Spinal
;
Incidence
;
Analgesics, Opioid/adverse effects*
;
Aged, 80 and over
2.Analgesic effect of "cocktail" analgesia containing high-dose compound betamethasone after revision hip arthroplasty and the use of opioid drugs.
Ning YANG ; Wulamu WUHUZI ; Xiaobin GUO ; Yicheng LI ; Xiaogang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):314-319
OBJECTIVE:
To investigate the analgesic effect of locally injecting a "cocktail" analgesia containing a high-dose compound betamethasone during revision hip arthroplasty, and also to study the usage of opioid drugs.
METHODS:
A retrospective analysis was conducted on the clinical data of 180 patients who underwent revision hip arthroplasty due to aseptic loosening of the hip prosthesis between January 2015 and December 2021. Among them, 95 patients received intraoperative injection of "cocktail" analgesia containing high-dose compound betamethasone (group A), and 85 patients received intraoperative injection of traditional "cocktail" analgesia (group B). There was no significant difference in baseline data such as gender, age, body mass index, presence or absence of diabetes mellitus between the two groups ( P>0.05). The hospital stay, use of opioid drugs within 72 hours, and the incidence of adverse reactions within 72 hours after operation [including nausea and vomiting, insomnia, deep venous thrombosis (DVT), infection, etc.] were recorded and compared between the two groups. The pain relief of patients was evaluated using the static and dynamic visual analogue scale (VAS) scores at 12, 24, 48, and 72 hours after operation. The incidence of complications (including prosthesis re-loosening, hip joint dislocation, hip joint stiffness, limping, chronic pain, etc.) at 2 years after operation was recorded, and the Harris Hip Score (HHS) was used to evaluate the function at 2 years after operation.
RESULTS:
In group A, the utilization rate of opioid drugs within 72 hours after operation was significantly lower than that in group B ( P<0.05). However, there was no significant difference between the two groups in terms of hospital stay, as well as the incidence of adverse reactions such as nausea and vomiting, insomnia, DVT, and infection within 72 hours after operation ( P>0.05). The VAS scores of both groups decreased with time, and the differences between different time points were significant ( P<0.05). The static and dynamic VAS scores of group A were significantly lower than those of group B at 12, 24, and 48 hours after operation ( P<0.05), but there was no significant difference in static and dynamic VAS scores between the two groups at 72 hours after operation ( P>0.05). All patients in both groups were followed up 2-8 years, with an average of 5.73 years. At 2 years after operation, no significant difference was found between the two groups in the incidence of complications and HHS score ( P>0.05).
CONCLUSION
"Cocktail" analgesia containing a high-dose compound betamethasone for early analgesia after revision hip arthroplasty can effectively reduce postoperative pain and the use of opioid drugs, but will not increase the incidence of infection and DVT after operation.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Betamethasone/therapeutic use*
;
Retrospective Studies
;
Male
;
Female
;
Analgesics, Opioid/administration & dosage*
;
Pain, Postoperative/prevention & control*
;
Middle Aged
;
Reoperation
;
Aged
;
Analgesia/methods*
;
Adult
;
Pain Measurement
;
Pain Management/methods*
;
Prosthesis Failure
;
Hip Prosthesis
3.Research progress in application of intelligent remote follow-up mode in hip and knee arthroplasty.
Yunhao TANG ; Xin WANG ; Wei CHAI ; Fangyuan YU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):375-383
OBJECTIVE:
To review the research progress of intelligent remote follow-up modes in the application after hip and knee arthroplasty.
METHODS:
Extensive literature on this topic published in recent years both domestically and internationally was reviewed, and the application of intelligent remote follow-up modes after hip and knee arthroplasty was summarized and analyzed.
RESULTS:
The intelligent remote follow-up mode is a novel follow-up method based on network information technology. Patients who undergo hip and knee arthroplasty require long-term follow-up and rehabilitation guidance after operation. Traditional outpatient follow-up is relatively time-consuming and inconvenient for some patients in terms of travel and transportation, which makes the application of intelligent remote follow-up modes increasingly widespread worldwide. The inherent attributes of remote interaction and instant feedback of this mode make it particularly valued in the field of hip and knee arthroplasty. Artificial intelligence (AI)-based voice follow-up systems and virtual clinics have significant advantages in improving follow-up efficiency, reducing human resource costs, and enhancing patient satisfaction.
CONCLUSION
The existing intelligent follow-up system has formed a standardized protocol in remote follow-up and rehabilitation guidance. However, there are still shortcomings in the formulation of personalized rehabilitation plans and the gerontechnological adaptation of human-computer interaction. In the future, it is necessary to construct a multimodal data fusion platform and establish technical application guidelines for different rehabilitation stages.
Humans
;
Arthroplasty, Replacement, Knee/rehabilitation*
;
Arthroplasty, Replacement, Hip/rehabilitation*
;
Artificial Intelligence
;
Follow-Up Studies
;
Telemedicine
4.Feasibility study on measuring anteversion angle of acetabular prosthesis after total hip arthroplasty using arbitrary point method.
Bowen LI ; Longyuan LI ; Heng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):420-424
OBJECTIVE:
To explore the reliability and accuracy of the arbitrary point method for measuring the anteversion angle of acetabular prosthesis after total hip arthroplasty (THA) based on pelvic X-ray films.
METHODS:
The clinical data of 23 patients (25 hips) who underwent THA between December 2018 and September 2023 and met the selection criteria were retrospectively analyzed. Among them, there were 16 males and 7 females, with an average age of 57.6 years (range, 34-81 years); 13 hips had THA on the left side and 12 on the right side. There were 19 cases (21 hips) of osteonecrosis of the femoral head, 2 cases (2 hips) of femoral neck fractures, 1 case (1 hip) of developmental dysplasia of the hip, and 1 case (1 hip) of osteoarthritis. After THA, all patients underwent X-ray examination and CT scan. Three physicians measured the anteversion angle of acetabular prosthesis using the arbitrary point method and the CT measurement method respectively, and repeated the measurements three times. The results of the two measurement methods were compared, and the intraclass correlation coefficient (ICC) was employed to assess the reproducibility of the methods.
RESULTS:
The anteversion angles of acetabular prosthesis were (15.87±7.73)° measured by the arbitrary point method, and (15.31±7.89)° measured by CT measurement method. There was no significant difference between the two methods ( t=1.515, P=0.143). The ICC of the measurement results by the arbitrary point method for the three physicians were 0.97 ( P<0.001), 0.96 ( P<0.001), and 0.96 ( P<0.001), respectively; and the ICC of the measurement results by CT method were 0.93 ( P<0.001), 0.93 ( P<0.001), and 0.94 ( P<0.001), respectively.
CONCLUSION
The arbitrary point method for measuring the anteversion angle of acetabular prosthesis after THA based on pelvic X-ray film is easy to operate, accurate, and has high reproducibility.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Hip Prosthesis
;
Acetabulum/surgery*
;
Aged, 80 and over
;
Retrospective Studies
;
Adult
;
Reproducibility of Results
;
Feasibility Studies
;
Tomography, X-Ray Computed
5.Comparison of muscle injury between piriformis muscle release and preservation in total hip arthroplasty via supercapsular percutaneously-assisted total hip approach.
Fengping GAN ; Qibiao ZHANG ; Fulai MO ; Linjie LI ; Fei ZHENG ; Xinxin LIN ; Hao QIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):715-722
OBJECTIVE:
To compare the effects of piriformis muscle release versus preservation in total hip arthroplasty (THA) via supercapsular percutaneously-assisted total hip (SuperPATH) approach on muscle injury.
METHODS:
Forty-nine patients undergoing initial THA via SuperPATH approach between June 2022 and June 2023 were randomly divided into two groups, with 24 patients in trial group and 25 patients in control group. The trial group received piriformis muscle release intraoperatively, whereas the control group underwent muscle preservation. There was no significant difference in baseline data such as gender, age, body mass index, disease type, American Society of Anesthesiologists (ASA) grading, and preoperative muscle infiltration, muscle atrophy, muscle injury serological indicators, Harris score, etc. ( P>0.05). The incision length, operation time, intraoperative blood loss, total blood loss, hospital stay, preoperative and postoperative 1-day muscle injury serological indicators [including creatine kinase (CK) and lactic dehydrogenase (LDH)], and incidence of complications between two groups were recorded. Harris score was used to evaluate the recovery of hip joint function. MRI was used to evaluate the extent of hip muscle injuries (gluteus minimus, gluteus medius, piriformis, obturator internus, quadratus femoris), including tendon integrity, degree of muscle fat infiltration, and degree of muscle atrophy preoperative and 1 year postoperatively.
RESULTS:
The operation time, intraoperative blood loss, and total blood loss in the trial group were significantly shorter than those in the control group ( P<0.05). There was no significant difference in the incision length and length of hospital stay between the two groups ( P>0.05). Both groups showed a significant increase in serum CK and LDH levels on postoperative day 1 compared to preoperative levels ( P<0.05), but there was no significant difference between the two groups ( P>0.05). All patients were followed up, the follow-up time for the trial group and the control group was (14.8±2.8) and (15.1±3.0) months, respectively, with no significant difference ( t=-0.400, P=0.691). Incisions healed by first intention in both groups, with 1 case in the trial group and 2 cases in the control group experiencing venous thrombosis in the calf muscle space. There was no complication such as deep vein thrombosis, pulmonary embolism, hip dislocation, prosthesis loosening, or periprosthetic infection in the lower limbs. There was no significant difference in the incidence of complications between the two groups ( P>0.05). At 1 year after operation, both groups of patients showed a significant increase in Harris scores compared to preoperative levels ( P<0.05), but there was no significant difference between the two groups ( P>0.05). Compared with preoperative results, both groups showed significant fat infiltration in the piriformis and obturator muscles at 1 year after operation ( P<0.05), while there was no significant fat infiltration in the gluteus minimus, gluteus medius, and quadratus femoris muscles ( P>0.05). At 1 year after operation, except for the higher incidence of piriformis muscle fat infiltration in the control group compared to the trial group ( P<0.05), there was no significant difference in the incidence of other muscle infiltrations between the two groups ( P>0.05). At 1 year after operation, both groups of piriformis and obturator muscles showed significant muscle atrophy compared to preoperative levels ( P<0.05). The gluteus minimus and gluteus medius showed mild atrophy compared to preoperative levels, while the maximum transverse diameter of the quadriceps muscle slightly increased, but the differences were not significant ( P>0.05). There was no significant difference in the maximum cross-sectional diameter or cross-sectional area changes of each muscle between the two groups ( P>0.05). At 1 year after operation, the continuity of the gluteus medius and quadratus femoris muscles in both groups was intact. Both groups had some patients with incomplete continuity of the piriformis muscle, obturator internus, and gluteus minimus, but the difference was not significant ( P>0.05).
CONCLUSION
The SuperPATH approach THA may cause injury to the piriformis, gluteus minimus, and obturator internus. The piriformis muscle release does not increase muscle injury, but it can shorten the operation time and reduce bleeding.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Male
;
Female
;
Muscle, Skeletal/surgery*
;
Middle Aged
;
Aged
;
Postoperative Complications/epidemiology*
;
Adult
;
Operative Time
;
Muscular Atrophy
;
Creatine Kinase/blood*
;
Length of Stay
;
Treatment Outcome
6.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
7.2024 American Academy of Orthopaedic Surgeons (AAOS) Clinical Practice Guideline: Management of Osteoarthritis of the Hip (summary) interpretation.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1325-1332
Hip osteoarthritis (OA) is a significant disease worldwide that causes functional impairment and reduced quality of life. With the aging of the population and the increasing prevalence of obesity, its disease burden is becoming increasingly heavy. In December 2023, the American Academy of Orthopaedic Surgeons (AAOS) released the updated Clinical Practice Guideline for the Management of Osteoarthritis of the Hip (summary). Based on evidence-based medicine, this guideline provides systematic recommendations for the diagnosis and treatment of hip OA. This article will comprehensively interpret the guideline, compare it with relevant domestic expert consensus in China, analyze the consistency and differences in disease management strategies between the two, and provide references for clinical practice.
Humans
;
Academies and Institutes
;
Arthroplasty, Replacement, Hip
;
China
;
Evidence-Based Medicine
;
Orthopedic Surgeons
;
Orthopedics
;
Osteoarthritis, Hip/surgery*
;
Quality of Life
;
United States
8.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
9.Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection.
Geng-Yao ZHU ; Chao MA ; Guang-Wang LIU ; Jia-Zheng MAN
China Journal of Orthopaedics and Traumatology 2025;38(1):55-60
OBJECTIVE:
To investigate the clinical utility of novel of new hematological markers in the preoperative diagnosis of periprosthetic joint infection (PJI).
METHODS:
A retrospective analysis was conducted on a total of 149 patients who underwent revision of total hip arthroplasty (THA) or total knee arthroplasty (TKA) at a single center between January 2016 and June 2022, including 63 males and 86 females, aged from 47 to 93 years old with an average of (69.5±11.8) years old. Of them, 46 were diagnosed as PJI(PJI group), including 22 males and 24 females. The mean age was (71.3±12.5) years old. The body mass index (BMI) was (26.4±3.1) kg·m-2. And 103 patients were diagnosed as aseptic prosthesis loosening (aseptic group), including 41 males and 62 females. The mean age was (68.7±11.4) years old. The BMI was (25.8±3.5) kg·m-2. Preoperatively analyzed clinical parameters included C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), albumin, globulin, albumin-to-globulin ratio (AGR), plasma D-dimer, and plasma fibrinogen. The receiver operating characteristic curve (ROC), sensitivity, and specificity analysis were employed to compare the diagnostic value of each blood marker in preoperative PJI diagnosis.
RESULTS:
In the PJI group, the levels of CRP were 16.6 (7.6, 4.5) mg·L-1, ESR was 17.0 (12.8, 35.5) mm·h-1, plasma D-dimer was 1.0 (0.5, 3.1) μg·L-1, and plasma fibrinogen was 4.2 (3.2, 3.1) mg·L-1;all of which were higher compared to the aseptic group with CRP at 4.2 (2.6, 7.8) mg·L-1, ESR at 12.0(8.0, 20.0 )mm·h-l, D-dimer at 0.4(0.2, 0.7)μg·L-1, and fibrinogen at 2.8(2.4, 3.3 ) g·L-1(P<0.05). However, the albumin level of 35.3 (32.3, 37.5) g·L-1 and the WBC ratio of 1.0(0.9, 1.1) in the PJI group were significantly lower compared to the aseptic group with levels of 39.8 (36.1, 41.8) g·L-1 and 1.4 (1.3, 1.5), respectively (P<0.05). Only the area under the curve (AUC) of AGR and plasma fibrinogen were greater than 0.8. The optimal predictive cut-1off, AUC, sensitivity and specificity were 3.4 g·L-1, 0.820, 69.57% and 84.47% for plasma fibrinogen; 1.18, 0.813, 82.61% and 78.64% for AGR, respectively.
CONCLUSION
AGR and plasma fibrinogen are promising blood markers for improving the diagnosis of PJI.
Humans
;
Female
;
Fibrinogen/metabolism*
;
Male
;
Middle Aged
;
Aged
;
Prosthesis-Related Infections/blood*
;
Retrospective Studies
;
Biomarkers/blood*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Leukocyte Count
10.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome

Result Analysis
Print
Save
E-mail