1.Study on lightweight plasma recognition algorithm based on depth image perception.
Hanwen ZHANG ; Yu SUN ; Hao JIANG ; Jintian HU ; Gangyin LUO ; Dong LI ; Weijuan CAO ; Xiang QIU
Journal of Biomedical Engineering 2025;42(1):123-131
In the clinical stage, suspected hemolytic plasma may cause hemolysis illness, manifesting as symptoms such as heart failure, severe anemia, etc. Applying a deep learning method to plasma images significantly improves recognition accuracy, so that this paper proposes a plasma quality detection model based on improved "You Only Look Once" 5th version (YOLOv5). Then the model presented in this paper and the evaluation system were introduced into the plasma datasets, and the average accuracy of the final classification reached 98.7%. The results of this paper's experiment were obtained through the combination of several key algorithm modules including omni-dimensional dynamic convolution, pooling with separable kernel attention, residual bi-fusion feature pyramid network, and re-parameterization convolution. The method of this paper obtains the feature information of spatial mapping efficiently, and enhances the average recognition accuracy of plasma quality detection. This paper presents a high-efficiency detection method for plasma images, aiming to provide a practical approach to prevent hemolysis illnesses caused by external factors.
Algorithms
;
Humans
;
Hemolysis
;
Plasma
;
Deep Learning
;
Image Processing, Computer-Assisted/methods*
2.Research on flow characteristics of dual-outlet centrifugal disk blood pumps.
Qilong LIAN ; Yuan XIAO ; Yiping XIAO ; Zhanshuo CAO ; Guomin CUI
Journal of Biomedical Engineering 2025;42(2):374-381
Tesla blood pumps demonstrate a reduced propensity for hemolysis and thrombosis compared with vane blood pumps. Considering the restricted driving force within the secondary flow channel of vane blood pumps, along with the low hydraulic efficiency of conventional Tesla blood pumps and their internal flow characteristics that significantly contribute to hemolysis and thrombosis, this study introduces a set of vanes atop the rotor of the Tesla blood pump. This forms a dual-fluid domain rotor, and an axial dual-outlet volute shell structure is adopted to realize the separation of the fluid domains. Through numerical simulations of the new structure, a comparative analysis was conducted in this study on the internal flow characteristics of double-outlet and single-outlet volute shells, and symmetric and asymmetric cross-sections of the same rotor. The results indicate that the flow field distribution is more uniform under the double-outlet volute shell structure, and overall energy dissipation is decreased. After implementing the double-outlet design, in the asymmetric cross-section, compared with the symmetric cross-section, the fluid velocity gradient and turbulent kinetic energy at the tongue of the septum are reduced, and the fluid velocity gradient at the convergence of the diffuser tube outlets are also decreased. The maximum scalar stress is lower, and the decline in head and efficiency is mitigated. Moreover, compared with the single-outlet volute shell, the hemolysis index in the asymmetric cross-section is reduced. In summary, this paper proposes a novel dual-outlet centrifugal disk blood pumps, which can provide a reference for the structural design and performance optimization of magnetically levitated centrifugal blood pumps.
Heart-Assist Devices
;
Humans
;
Equipment Design
;
Hemolysis
;
Computer Simulation
3.Pollen-food allergy syndrome: association between allergen cross-reactivity and symptom severity.
Yuqiao ZHANG ; Fengxia YANG ; Xiaohui YAN ; Xueliang SHEN ; Ningyu FENG ; Ting YAO ; Shurong LI ; Xiyuan YAN ; Ruixia MA
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(12):1156-1162
Objective:To investigate the clinical characteristics and major allergens of patients with pollen-food allergy syndrome(PFAS) and their correlation with the severity of symptoms, and to provide a basis for identifying high-risk patients, optimizing the allergen testing process and developing individualized dietary management strategies. Methods:The clinical data of 166 patients with PFAS admitted to our hospital from January 2021 to July 2023 were retrospectively analyzed. The clinical symptoms, pollen types and food allergy of the patients were analyzed by questionnaire survey and serum specific IgE detection. phi coefficient, Apriori algorithm modeling and multivariate logistic regression analysis were used to evaluate the association between allergen and symptom severity. Results:Artemisia pollen was the most common allergen in this area, with a positive rate of 96.39%. Peach and mango were the most common food allergens, which caused allergic reactions in 24.10% and 22.89% of patients, respectively. Oral mucosal symptoms were the main symptoms. Correlation analysis showed that there was a correlation between pollen allergens and allergenic food. Association rule analysis showed that when the patient was allergic to the combination of peanuts and trees, the probability of high severity of symptoms was 82.35%. Multivariate analysis showed that ragweed allergy was significantly positively correlated with the severity of PFAS symptoms. Conclusion:Artemisia pollen and related food allergens play an important role in the pathogenesis of PFAS. Association rule mining and network map analysis revealed direct associations between peanut and tree combination allergy and symptom severity, as well as potential links between other inhaled allergens and specific food allergies. Ragweed and peach allergy are independent risk factors for the aggravation of PFAS symptoms, which can be used as early warning indicators. These results help to improve the screening of high-risk patients and the construction of regional allergen databases.
Humans
;
Food Hypersensitivity/immunology*
;
Allergens/immunology*
;
Retrospective Studies
;
Pollen/immunology*
;
Cross Reactions
;
Immunoglobulin E/blood*
;
Rhinitis, Allergic, Seasonal/immunology*
;
Artemisia/immunology*
;
Male
;
Female
;
Adult
;
Prunus persica/immunology*
;
Arachis/immunology*
;
Middle Aged
;
Surveys and Questionnaires
;
Oral Allergy Syndrome
4.Preparation of monoclonal antibodies with high specificity for glycated hemoglobin and establishment of a rapid detection method.
Chaofan YIN ; Yingfu ZHANG ; Kebei WANG ; Jichuang WANG ; Yongwei LI ; Xiaojun WANG ; Xudong WANG ; Panpan SHI ; Yunlong WANG
Chinese Journal of Biotechnology 2025;41(8):3165-3177
Hemoglobin A1c (HbA1c) has a unique structure that makes monoclonal antibody (mAb) preparation challenging. This study aims to develop a method for preparing HbA1c mAbs and establish a fluorescent immunochromatographic assay (FICA) for rapid detection of HbA1c. Three glycosylated peptides were synthesized and used to prepare complete antigens, which were identified by dot enzyme-linked immunosorbent assay (Dot-ELISA) and ultraviolet absorption spectroscopy. The complete antigens and natural HbA1c were used for cross-immunization of mice, and the optimal complete antigen was selected. The mouse with the highest serum titer was chosen for mAb preparation. The purity and specificity of the mAbs were verified, and a FICA method was developed. The optimal complete antigen, with a titer of 1:512 000, was successfully prepared and selected. Fusion with splenocytes resulted in four specific HbA1c antibodies (purity > 90%). The best antibody exhibited a binding constant (Ka) of 1.67×1010 L/mol with the antigen. Based on this antibody, a FICA method was successfully established, capable of producing results within 15 min. The method demonstrated a good linear range (3%-13% HbA1c, y=0.071 3x+0.005 6, R2=0.993 7), recovery rates of 98%-102%, precision < 10.00%, and no nonspecific reactions. Clinical testing of 210 samples showed positive agreement of 96.36%, negative agreement of 97.00%, and overall agreement of 96.68%. The receiver operating characteristic (ROC) curve analysis yielded an area under curve (AUC) of 0.980 9 [95% confidence interval (CI): 0.961 0-1.000 0], with high consistency verified in multicenter studies. We successfully developed a key technique for preparing HbA1c monoclonal antibodies and established a FICA method for rapid detection of HbA1c. It will provide an efficient and convenient detection method for the early diagnosis and long-term management of diabetes and its complications.
Antibodies, Monoclonal/biosynthesis*
;
Animals
;
Mice
;
Glycated Hemoglobin/immunology*
;
Mice, Inbred BALB C
;
Humans
;
Antibody Specificity
;
Chromatography, Affinity/methods*
;
Enzyme-Linked Immunosorbent Assay/methods*
;
Female
5.Optimization of centrifugal artificial heart pump blade parameters based on back propagation neural network and grey wolf optimization algorithm.
Lulu MU ; Huanhuan DUAN ; Yuan XIAO ; Guomin CUI
Journal of Biomedical Engineering 2024;41(6):1221-1226
The impeller, as a key component of artificial heart pumps, experiences high shear stress due to its rapid rotation, which may lead to hemolysis. To enhance the hemolytic performance of artificial heart pumps and identify the optimal combination of blade parameters, an optimization design for existing pump blades is conducted. The number of blades, outlet angle, and blade thickness were selected as design variables, with the maximum shear stress within the pump serving as the optimization objective. A back propagation (BP) neural network prediction model was established using existing simulation data, and a grey wolf optimization algorithm was employed to optimize the blade parameters. The results indicated that the optimized blade parameters consisted of 7 impeller blades, an outlet angle of 25 °, and a blade thickness of 1.2 mm; this configuration achieved a maximum shear stress value of 377 Pa-representing a reduction of 16% compared to the original model. Simulation analysis revealed that in comparison to the original model, regions with high shear stress at locations such as the outer edge, root, and base significantly decreased following optimization efforts, thus leading to marked improvements in hemolytic performance. The coupling algorithm employed in this study has significantly reduced the workload associated with modeling and simulation, while also enhancing the performance of optimization objectives. Compared to traditional optimization algorithms, it demonstrates distinct advantages, thereby providing a novel approach for investigating parameter optimization issues related to centrifugal artificial heart pumps.
Neural Networks, Computer
;
Algorithms
;
Heart-Assist Devices
;
Hemolysis
;
Humans
;
Equipment Design
;
Stress, Mechanical
;
Computer Simulation
6.Retrospective Analysis of Irregular Antibodies Causing Hemolytic Disease of the Fetus and Newborn in Jiangxi Province.
Xin LIU ; Fang LE ; Lian-Hui WANG ; Jin SHU ; Xiu-Yun XU
Journal of Experimental Hematology 2023;31(1):215-220
OBJECTIVE:
To analyze the characteristics of antibody-specific distribution, laboratory detection results of hemolytic disease of the fetus and neonatal(HDFN) caused by irregular blood group antibodies other than ABO, and its correlation with the clinical situation.
METHODS:
The non-ABO-HDFN cases in our hospital from October 2012 to December 2021 were selected as the research objects, and the cases diagnosed with ABO-HDFN in the same period were randomly selected as the control group, and the data of antibody specific distribution, total bilirubin, direct antibodies, maternal history, age of the children, the presence or absence of combined ABO-HDFN, and whether to exchange/transfuse blood were retrospectively analyzed. The characteristics of non-ABO-HDFN in Jiangxi province were analyzed.
RESULTS:
The detection rate of non-ABO-HDFN in Jiangxi province increased. Among 187 non ABO-HDFN cases, the highest percentage of Rh-HDFN was detected (94.6%). Compared with the control group of ABO-HDFN, the non-ABO-HDFN had higher mean integral value of direct antibody, higher peak total bilirubin, and longer duration. Anti-M-HDFN may have severe disease but the direct antibody weak positive/negative, it was easy missed in clinical and delayed the treatment. There is no correlation between the specificity of irregular antibodies, the sex of the child, the mother's previous childbirth history, the presence or absence of combined ABO-HDFN and the need for blood exchange/transfusion(P>0.05).
CONCLUSION
The irregular antibodies of causing non ABO-HDFN in Jiangxi area are mainly Rh blood group system, followed by MNS blood group system. Understanding the characteristics of HDFN disease, serological features and the correlation with clinical indexes will help to detect and treat non ABO-HDFN in time and reduce the risk of complications.
Child
;
Female
;
Humans
;
Infant, Newborn
;
ABO Blood-Group System
;
Blood Group Antigens
;
Erythroblastosis, Fetal
;
Fetus
;
Hematologic Diseases/complications*
;
Hemolysis
;
Isoantibodies
;
Retrospective Studies
8.Research progress of oral allergy syndrome.
Zhuang Zhuang FAN ; Zhi Yue LU ; Jian Qiu JIN
Chinese Journal of Preventive Medicine 2023;57(3):341-347
Oral allergy syndrome (OAS) is an IgE-mediated hypersensitivity. Patients with pollen allergy will experience oropharyngeal allergy after eating fresh fruits or vegetables containing homologous pathogenesis-related allergen, occasionally accompanied by systemic symptoms, it is a special type of food hypersensitivity in which respiratory allergens and food allergens are similar structurally and lead to the cross-reactivity. At present, there is little research and attention to it in China. To master the definition, epidemiological characteristics, pathological mechanism, diagnosis, prevention and treatment of OAS is very important to the prevention and control of OAS. This article reviews the research progress of OAS, providing reference and prevention basis for clinicians to improve the diagnosis and differential diagnosis of OAS.
Humans
;
Pollen
;
Food Hypersensitivity/diagnosis*
;
Rhinitis, Allergic, Seasonal/therapy*
;
Allergens
;
Fruit
;
Cross Reactions
9.Poisonous substances and geographical distribution of poisoning in hospitalized children based on data from 25 hospitals in China from 2016 to 2020.
Li Ming CAI ; Xin Yu WANG ; Guo Shuang FENG ; Yue Ping ZENG ; Xin XU ; Yong Li GUO ; Jian TIAN ; Heng Miao GAO
Chinese Journal of Pediatrics 2023;61(10):910-916
Objective: To investigate the poisonous substances and geographical distribution of poisoning in children in China. Methods: A cross-sectional study. The clinical data of 8 385 hospitalized children from January 2016 to December 2020 were extracted from the FUTang Updating Medical Records database. These children aged 0 to 18 years and were admitted due to poisoning. They were grouped according to age (newborns and infants, toddlers, preschoolers, school-age children, adolescents), place of residence (Northeast China, North China, Central China, East China, South China, Southwest China, Northwest China), and mode of discharge (discharge under medical advice, transfer to another hospital under medical advice, discharge without medical advice, death, other). The poisonous substance and causes of poisoning in different groups were analyzed. Results: Among these 8 385 children, 4 734 (56.5%) were male and 3 651 (43.5%) female, with a male-to-female ratio of 1.3∶1. The age was 3 (2, 7) years. The prevalence of poisoning was 51.8% (4 343/8 385) in toddlers, 16.5% (1 380/8 385) in adolescents, 14.8% (1 242/8 385) in preschoolers, 14.4% (1 206/8 385) in school-age children, and 2.5% (214/8 385) in newborns and infants. Drug poisoning accounted for 43.5% (3 649/8 385) and pesticide accounted for 26.8% (2 249/8 385). Drug poisoning was more common in adolescents (684/1 380, 49.6%) and toddlers (2 041/4 343, 47.0%); non-drug poisoning was more common in school-age children (891/1 206, 73.9%), of which carbon monoxide was mainly in newborns and infants (41/214, 19.2%) and food poisoning in children of school age (241/1 206, 20.0%). Regarding regional characteristics, drug poisoning was more frequent in South China (188/246, 64.2%) and non-drug poisoning was more frequent in Southwest China (815/1 123, 72.5%). For drugs, anti-epileptic drugs, sedative-hypnotic drugs and anti-Parkinson's disease drugs had a higher proportion of poisoning in North China (138/1 034, 13.0%) than that in other regions. For non-drug poisoning, pesticides (375/1 123, 33.3%), food poisoning (209/1 123, 18.6%) and contact with poisonous animals (86/1 123, 7.7%) were more common in Southwest China than in other regions; carbon monoxide poisoning was more common in North China (81/1 034, 7.6%) and Northwest China (65/1 064, 6.3%). In Central China, poisoning happened more in toddlers (792/1 295, 61.2%) and less in adolescents (115/1 295, 8.8%) than in other regions. Regarding different age groups, poisoning in adolescent happened more in Northeast China (121/457, 26.5%), North China (240/1 034, 23.2%), and Northwest China (245/1 064, 23.0%). The rate of discharge under medical advice, discharge without medical advice, and mortality rate within the 5 years were 77.0% (6 458/8 385), 20.8% (1 743/8 385), 0.5% (40/8 385), respectively. Conclusions: Poisoning is more common in male and toddlers. Poisonous substances show a regional characteristic and vary in different age groups, with drugs and insecticides as the most common substances.
Infant
;
Adolescent
;
Animals
;
Child
;
Male
;
Humans
;
Infant, Newborn
;
Female
;
Child, Hospitalized
;
Cross-Sectional Studies
;
Carbon Monoxide Poisoning/epidemiology*
;
Pesticides
;
Foodborne Diseases
;
Hospitals
;
Drug-Related Side Effects and Adverse Reactions
;
China/epidemiology*
10.Analysis of frequency and molecular genetics of Jk (a-b-) phenotype among blood donors from Jining area.
Na ZHANG ; Huanhuan GAO ; Hongjun GAO
Chinese Journal of Medical Genetics 2023;40(5):609-613
OBJECTIVE:
To screen for Jk(a-b-) phenotype among blood donors from Jining area and explore its molecular basis to enrich the rare blood group bank for the region.
METHODS:
The population who donated blood gratuitously at Jining Blood Center from July 2019 to January 2021 were selected as the study subjects. The Jk(a-b-) phenotype was screened with the 2 mol/L urea lysis method, and the result was confirmed by using classical serological methods. Exons 3 to 10 of the SLC14A1 gene and its flanking regions were subjected to Sanger sequencing.
RESULTS:
Among 95 500 donors, urea hemolysis test has identified three without hemolysis, which was verified by serological method as the Jk(a-b-) phenotype and demonstrated no anti-Jk3 antibody. The frequency of the Jk(a-b-) phenotype in Jining area is therefore 0.0031%. Gene sequencing and haplotype analysis showed that the genotypes of the three samples were JK*02N.01/JK*02N.01, JK*02N.01/JK-02-230A and JK*02N.20/JK-02-230A, respectively.
CONCLUSION
The splicing variant of c.342-1G>A in intron 4, missense variants of c.230G>A in exon 4, and c.647_ 648delAC in exon 6 probably underlay the Jk(a-b-) phenotype in the local population, which is different from other regions in China. The c.230G>A variant was unreported previously.
Humans
;
Phenotype
;
Blood Donors
;
Hemolysis
;
Kidd Blood-Group System/genetics*
;
Urea
;
Molecular Biology

Result Analysis
Print