1.Determination of 6PPDQ in human plasma and urine by ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry
Wenjie ZHANG ; Jing YUAN ; Anping MA ; Jingjing QIU ; Yukun CHEN ; Yiru QIN ; Banghua WU
China Occupational Medicine 2025;52(4):441-444
Objective To establish an ultra-high-performance liquid chromatography-triple quadrupole tandem mass spectrometry method for the determination of N-(1,3-dimethylbutyl)-N′-phenyl-p-phenylenediamine quinone (6PPDQ) in human plasma and urine. Methods Plasma and urine samples (0.3 mL each) were mixed with 0.9 mL acetonitrile and dichloromethane, vortexed, and subjected to ultrasonic treatment to facilitate extraction. After centrifugation, the extract was collected, evaporated to dry powder under nitrogen, and reconstituted. Separation was performed on a C18 column, and detection was carried out using ultra-high-performance liquid chromatography-triple quadrupole tandem mass spectrometry with external standard quantification. Results 6PPDQ showed good linearity in the range of 0.01-25.00 μg/L in both human plasma and urine, with correlation coefficients of 0.999 5 and 0.999 7, respectively. The detection limits for plasma and urine were 8 and 6 ng/L, and the lower limits of quantification were 27 and 19 ng/L, respectively. The average recovery rates were 97.00%-100.00% for plasma and 90.00%-96.50% for urine. The within-run relative standard deviations (RSDs) were 4.35%-10.00% for plasma and 2.34%-11.11% for urine, while the between-run RSDs were 6.80%-8.46% and 2.60%-10.00%, respectively. Samples can be stored for seven days at 4 ℃ or -20 ℃. respectively. Samples can be stored for seven days at 4 ℃ or -20 ℃. Matrix effects ranged from 87.12%-99.27% for plasma and 91.00%-97.56% for urine. Conclusion The proposed method is simple, highly sensitive, and reproducible, and is suitable for the determination of 6PPDQ in human plasma and urine samples.
2.Improved gas chromatographic method for biphenyl detection in workplace air
Jiaheng HE ; Weifeng RONG ; Jiawen HU ; Jing YUAN ; Anping MA ; Ruibo MENG ; Banghua WU
China Occupational Medicine 2025;52(4):445-449
Objective To improve the national standardized method for determining biphenyl in workplace air, which was based on activated carbon tube sampling, carbon disulfide desorption, and gas chromatography, by developing a method using GDX-502 tubes for sampling, toluene for desorption, and gas chromatography. Methods Workplace air samples were collected using GDX-502 sampling tubes and desorbed with toluene, followed by determination with gas chromatography. Results The improved method demonstrated good linearity for biphenyl concentrations ranging from 0.33 to 330.00 mg/L, with a correlation coefficient of 0.999 9. The detection limit and lower limit of quantification were 0.06 and 0.21 mg/L, and the minimum detection concentration and minimum quantification concentration were 0.04 and 0.14 mg/m3 (based on 1.5 L air sample volume), respectively. The average desorption efficiency ranged from 96.6% to 101.1%. The within-run and between-run relative standard deviations were 0.6%-1.4% and 1.4%-3.3%, respectively, with 100.0% sampling efficiency. Samples remained stable for at least 14 days at room temperature. Conclusion The improved method for biphenyl detection demonstrates rapid and accurate performance, with the advantages of low detection limits and high sampling and desorption efficiency.
3.Metabolic profile analysis on urine of workers with occupational nickel exposure
Zuofei XIE ; Anping MA ; Wenjie ZHANG ; Lin ZHONG ; Jingjing QIU ; Zuokan LIN ; Yi SUN ; Weihui WANG ; Zhanhong YANG ; Liuqing ZHAO ; Yiru QIN ; Weifeng RONG
China Occupational Medicine 2024;51(5):488-495
Objective To analyze differential metabolites (DMs) in the urine of workers with occupational nickel exposure using non-targeted metabolomics, and to screen differential metabolic pathways. Methods A total of 30 nickel exposed workers were selected as the exposure group, and 30 administrative staff from the same factory were selected as the control group using the judgment sampling method. Urine samples of the individuals from the two groups were collected. The ultra-high performance liquid chromatography with quadrupole time-of-flight mass spectrometry and non-targeted metabolomics were used to detect and identify metabolites. The differential metabolic profiles were compared between workers of the two groups, and key differential metabolic pathways and potential biomarkers were screened. The association of DMs and urinary nickel level were evaluated by Spearman correlation coefficients. The sensitivity and specificity of biomarkers were assessed by receiver operating characteristic (ROC) curve analysis. Results A total of 418 metabolites were identified in the urine of worker in the exposure and control groups. The result of principal component analysis and orthogonal partial least squares analysis showed that there were 128 DMs in the urine of workers in the exposure group compared with the control group. These DMs were mainly enriched in glutathione metabolism, carnitine synthesis, and amino acid and nucleotide metabolism pathways, including glycine and serine metabolism. The result of correlation analysis and ROC curve analysis revealed that 4-methylcatechol, 4-vinylphenol sulfate, 2-hydroxyphenylacetone sulfate, 2-dodecylbenzenesulfonic acid, and decylbenzenesulfonic acid could be the potential biomarkers for nickel exposure (all area under the ROC curve >0.800). Conclusion There were significant differences in the urinary metabolic profiles of workers with occupational nickel exposure. The five DMs including 4-methylcatechol, 4-vinylphenol sulfate, 2-hydroxyphenylacetone sulfate, 2-dodecylbenzenesulfonic acid, and decylbenzenesulfonic acid. These DMs could be potential biomarkers of occupational nickel exposure.
4.Advances in rapid detection methods of biotoxins in blood
Wenjie ZHANG ; Yiru QIN ; Zuofei XIE ; Anping MA ; Jingjing QIU ; Zuokan LIN ; Jiaheng HE ; Zhanhong YANG ; Weifeng RONG ; Banghua WU
China Occupational Medicine 2024;51(5):575-580
Biotoxins, which include bacterial, fungal, marine, plant, and animal toxins, are widespread in living and occupational environments, posing potential threats to human health. Rapid detection of biotoxins in blood is crucial for preventing health hazards and enabling timely disease diagnosis and treatment. Biosensors and immunoassay technologies have critical advantages in the rapid detection of biotoxins in blood. Common biosensors, such as surface plasmon resonance biosensors and fluorescent biosensors, enhance sensitivity and reduce detection limits through signal amplification. Common immunoassay methods, such as colloidal gold immunochromatography, fluorescence immunochromatography, and chemiluminescence immunoassay, improve detection efficacy and sensitivity through specific antibody-antigen binding and nanotechnology. However, current rapid detection technologies of bitoxins in blood face challenges such as matrix interference and insufficient specificity, and they fall short in high-throughput detection of multiple toxins simultaneously. Future developments should focus on improving sample pretreatment, innovating signal amplification methods, enhancing specificity on recognition of elements, and designing portable detection devices and high-throughput platforms for simultaneous toxin analysis. These advancements aim to improve the sensitivity and reliability of detection methods, providing more accurate and convenient solutions for biotoxin detection in blood.
5.Exosome-mediated lnc-ABCA12-3 promotes proliferation and glycolysis but inhibits apoptosis by regulating the tolllike receptor 4uclear factor kappa-B signaling pathway in esophageal squamous cell carcinoma
Junliang MA ; Yijun LUO ; Yingjie LIU ; Cheng CHEN ; Anping CHEN ; Lubiao LIANG ; Wenxiang WANG ; Yongxiang SONG
The Korean Journal of Physiology and Pharmacology 2023;27(1):61-73
Esophageal squamous cell carcinoma (ESCC) is a kind of malignant tumor with high incidence and mortality in the digestive system. The aim of this study is to explore the function of lnc-ABCA12-3 in the development of ESCC and its unique mechanisms. RT-PCR was applied to detect gene transcription levels in tissues or cell lines like TE-1, EC9706, and HEEC cells. Western blot was conducted to identify protein expression levels of mitochondrial apoptosis and toll-like receptor 4 (TLR4)uclear factor kappa-B (NF-κB) signaling pathway. CCK-8 and EdU assays were carried out to measure cell proliferation, and cell apoptosis was examined by flow cytometry. ELISA was used for checking the changes in glycolysis-related indicators.Lnc-ABCA12-3 was highly expressed in ESCC tissues and cells, which preferred it to be a candidate target. The TE-1 and EC9706 cells proliferation and glycolysis were obviously inhibited with the downregulation of lnc-ABCA12-3, while apoptosis was promoted. TLR4 activator could largely reverse the apoptosis acceleration and relieved the proliferation and glycolysis suppression caused by lnc-ABCA12-3 downregulation. Moreover, the effect of lnc-ABCA12-3 on ESCC cells was actualized by activating the TLR4/NF-κB signaling pathway under the mediation of exosome. Taken together, the lnc-ABCA12-3 could promote the proliferation and glycolysis of ESCC, while repressing its apoptosis probably by regulating the TLR4/NF-κB signaling pathway under the mediation of exosome.
6.Metabolomics study on occupational acute methyl acetate poisoning using patient plasma
Yiru QIN ; Anping MA ; Jingjing QIU ; Yin HAN ; Jiayun WU ; Zuofei XIE ; Yangle SUN ; Junyi HUANG ; Ming DONG ; Weifeng RONG ; Banghua WU ; Shijie HU
China Occupational Medicine 2023;50(2):127-132
7.Determination of four organotin compounds in human whole blood by high performance liquid chromatography-inductively coupled plasma-mass spectrometry
Anping MA ; Banghua WU ; Ming DONG ; Xiaolin RUAN ; Jingjing QIU ; Weifeng RONG ; Jiaheng HE
China Occupational Medicine 2023;50(6):712-716
{L-End}Objective To establish a method for the simultaneous determination of dimethyltin (DMT), trimethyltin (TMT), diethyltin (DET), and triethyltin (TET) in human whole blood using high performance liquid chromatography-inductively coupled plasma-mass spectrometry (ICP-MS). {L-End}Methods The 1.0 mL of blood was added with 4.0 mL 65% aqueous solution (containing 6% acetic acid), extracted and separated by C4 column (150 mm×3 mm×3 μm) using a mobile phase of methanol and 4% acetic acid aqueous solution (containing 0.25 mmol/L tropolone) at a volume ratio of 35∶65, and detected by ICP-MS. {L-End}Results The linear range of DMT, TMT, DET, and TET was 30.60-550.80, 29.00-522.00, 46.10-829.80, and 34.05-612.90 μg/L, respectively. All correlation coefficients were 0.999. The detection limit of DMT, TMT, DET and TET was 21.40, 20.30, 32.27 and 23.80 μg/L, respectively. The recovery rate was 81.9%-104.9%. The within-run and between-run relative standard deviation was 1.6%-6.9% and 0.1%-10.0%, respectively. The samples can be stored at -20 ℃ and 4 ℃ for at least three days. {L-End}Conclusion This method can be used for trace analysis of DMT, TMT, DET, and TET in whole blood.
8.Predictive value of hemoglobin glycation index for chronic kidney disease
Lu LIN ; Anping WANG ; Jingtao DOU ; Yulong CHEN ; Yang LIU ; Fangling MA ; Hua ZHENG ; Liguang DONG ; Shuyu WANG ; Yiming MU
Chinese Journal of Internal Medicine 2022;61(12):1310-1317
Objective:To investigate the influence of hemoglobin glycation index (HGI) on the risk of incident chronic kidney disease (CDK) among nondiabetic patients.Methods:Prospective cohort study. At baseline, a total of 7 407 nondiabetic patients without a history of CKD from Pingguoyuan Community of the Shijingshan District in Beijing were included from December 2011 to August 2012, who were then divided into three groups according to the tertiles of their baseline HGI levels. The CKD incidence rate was compared among the different HGI groups at last follow-up. Cox multivariable regression was applied to evaluate whether HGI measures predicted CKD risk. Test for trend across tertiles were examined using ordinal values in separate models.Results:The mean age of the subjects was (56.4±7.5) years, and 4 933 (66.6%) were female. At mean follow-up of 3.23 years, 107 (1.4%) individuals developed CKD. The incidence of CKD was gradually increasing from the low to high HGI groups [1.1% (28/2 473) vs. 1.2% (31/2 564) vs. 2.0% (48/2 370), P=0.016]. In the multivariate Cox regression analysis, after adjustment for potential confounders, the high HGI group had a 68.5% increased risk of CKD compared with the low HGI group ( HR=1.685, 95% CI 1.023 to 2.774). CKD risk increased with increasing HGI tertiles ( P for trend=0.028). Conclusion:High HGI is associated with an increased risk for CKD in the nondiabetic population, indicating that HGI may help identify individuals at high risk for CKD.
9.The application of "internet +" disease management based on the AISAS model on young and middle-aged patients after PCI therapy
Jiaoyu CAO ; Panpan SUN ; Lixiang ZHANG ; Xia CHEN ; Anping OU ; Wenjuan GUI ; Likun MA
Chinese Journal of Practical Nursing 2021;37(15):1121-1127
Objective:To investigate the effect of the application of "internet +" disease management based on the AISAS model on the young and middle-aged patients after PCI therapy.Method:A total of 90 young and middle-aged patients hospitalized in cardiological department of the First Affiliated Hospital of University of Science and Technology of China (Anhui Provincial Hospital) were enrolled between June 2018 to October 2019, and they were randomly divided into observation group and control group with 45 cases in each group. Patients in the control group received telephone follow-up while "internet +" disease management based on the AISAS model was applied in the observation group. The drug therapy compliance, acquisition of the disease knowledge, quality of life, anxiety and depression levels, return to workand incidence of cardiovascular events.Results:One year after the intervention, the drug therapy compliance score, disease-related knowledge score, quality of life score, SAS and SDS scores of the observation group were 7.55±1.21, 7.29±1.27, 701.17±74.86, 32.55± 4.31, 34.74±4.16, the scores of patients in the control group were 6.48±1.56, 6.12±1.94, 670.58±65.29, 41.72±4.33, 40.79±4.17. The difference was statistically significant ( t value was 2.066-11.203, P<0.05). The comparison between the return of the patients and the incidence of cardiovascular events in the two groups was statistically significant ( χ2 value was 5.031, 11.275, P<0.05). Conclusion:This management model can increase the knowledge of disease PCI postoperative patients, improve their quality of life, make patients return to society earlier, and promote the improvement of the quality of continuous nursing service.
10. Detecting thiocyanate in human urine by precolumn derivatization-high performance liquid chromatography
Jing YUAN ; Xiaolin RUAN ; Weifeng RONG ; Jiawen HU ; Anping MA
China Occupational Medicine 2018;45(03):373-376
OBJECTIVE: To establish a method for detecting thiocyanate in human urine by high performance liquid chromatography( HPLC) with 2,3,4,5,6-pentafluorobenzyl bromide as precolumn derivatization reagent.METHODS: Thiocyanate in human urine was derived with 2,3,4,5,6-pentafluorobenzyl bromide, and separated by poroshell 120EC-C18 column with acetonitrile:deionized water( 60:40,V/V) as mobile phase.detected by HPLC,Liquid chromatography-UV detector was used for determination.The wavelength was 212.00 nm.RESULTS: Good linearity was obtained in the range of 0.05-10.32 mg/L with the correlation coefficient of 0.999.The detection limit was 6.31 μg/L and the minimum detection concentration was 63.10 μg/L( 0.1 mL urine).The recovery rate was 95.1%-102.9%.The within-run relative standard deviation( RSD) and the between-run RSD were 0.9%-1.0% and 0.9%-2.1%,respectively.The urine samples could be stored at 4 ℃ for 7 days.CONCLUSION: This method has high sensitivity,good specificity and sample preparation,which can be used for detecting urine thiocyanate in occupational population.

Result Analysis
Print
Save
E-mail