1.Evaluation of ankle joint protection effect of parachute ankle brace on paratrooper landing.
Xin Yu HUANG ; Ying Jie YU ; Yi Jun WANG ; Tao LIU ; Jing Di CHEN ; Lei WU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(7):504-508
Objective: To study the protective effect of parachute ankle brace on ankle joint during simulated parachuting landing. Methods: In August 2021, 30 male paratroopers were selected as the test subjects by simple random sampling method. They jumped from the 1.5 m and 2.0 m height platforms respectively with and without parachute ankle brace, and landed on the sandy ground in a semi-squat parachute landing position. The experiment was divided into 1.5 m experimental group and control group and 2.0 m experimental group and control group. Angle sensor and surface electromyograph were used to measure and analyze the coronal tilt range of the ankle joint and the percentage of maximal voluntary contraction (MVE%) of the muscles around the ankle joint, respectively, to evaluate the protective effect of the parachute ankle brace. Results: At the same height, the tilt range of coronal plane of ankle in experimental group was significantly reduced compared with control group, and the difference was statistically significant (P<0.05). Under the same protection state, the tilt range of the coronal plane of the ankle in the 1.5 m group was significantly reduced compared with that in the 2.0 m group, and the difference was statistically significant (P<0.05). The coronal plane inclination range of the ankle in 2 m experimental group was significantly lower than that in 1.5 m control group, and the difference was statistically significant (P<0.05). Compared with 1.5 m control group, MVE% of right tibialis anterior muscle and bilateral lateral gastrocnemius decreased in 1.5 m experimental group, while MVE% of bilateral peroneus longus increased, with statistical significance (P<0.05). Compared with 2.0 m control group, the MVE% of bilateral tibialis anterior muscle and right lateral gastrocnemius decreased in 2.0 m experimental group, while the MVE% of bilateral peroneus longus increased, with statistical significance (P<0.05). The MVE% of bilateral tibialis anterior muscle, bilateral lateral gastrocnemius muscle and right peroneus longus muscle in 1.5 m experimental group decreased compared with 2.0 m experimental group, and the differences were statistically significant (P<0.05). Compared with 2.0 m control group, the MVE% of bilateral tibialis anterior muscle, right lateral gastrocnemius muscle and right peroneus longus muscle in 1.5 m control group decreased, and the differences were statistically significant (P<0.05) . Conclusion: Wearing parachute ankle brace can effectively limit the coronal plane inclination range of ankle joint, improve the stability of ankle joint and reduce the load on the muscles around ankle joint by landing. Reducing the height of the jumping platform can reduce the coronal plane incline range of the ankle and the muscle load around the ankle during landing.
Humans
;
Male
;
Ankle
;
Ankle Joint/physiology*
;
Lower Extremity/physiology*
;
Muscle, Skeletal/physiology*
;
Electromyography
2.Effects of ankle exoskeleton assistance during human walking on lower limb muscle contractions and coordination patterns.
Wei WANG ; Jianquan DING ; Yi WANG ; Yicheng LIU ; Juanjuan ZHANG ; Jingtai LIU
Journal of Biomedical Engineering 2022;39(1):75-83
Lower limb ankle exoskeletons have been used to improve walking efficiency and assist the elderly and patients with motor dysfunction in daily activities or rehabilitation training, while the assistance patterns may influence the wearer's lower limb muscle activities and coordination patterns. In this paper, we aim to evaluate the effects of different ankle exoskeleton assistance patterns on wearer's lower limb muscle activities and coordination patterns. A tethered ankle exoskeleton with nine assistance patterns that combined with differenet actuation timing values and torque magnitude levels was used to assist human walking. Lower limb muscle surface electromyography signals were collected from 7 participants walking on a treadmill at a speed of 1.25 m/s. Results showed that the soleus muscle activities were significantly reduced during assisted walking. In one assistance pattern with peak time in 49% of stride and peak torque at 0.7 N·m/kg, the soleus muscle activity was decreased by (38.5 ± 10.8)%. Compared with actuation timing, the assistance torque magnitude had a more significant influence on soleus muscle activity. In all assistance patterns, the eight lower limb muscle activities could be decomposed to five basic muscle synergies. The muscle synergies changed little under assistance with appropriate actuation timing and torque magnitude. Besides, co-contraction indexs of soleus and tibialis anterior, rectus femoris and semitendinosus under exoskeleton assistance were higher than normal walking. Our results are expected to help to understand how healthy wearers adjust their neuromuscular control mechanisms to adapt to different exoskeleton assistance patterns, and provide reference to select appropriate assistance to improve walking efficiency.
Aged
;
Ankle/physiology*
;
Ankle Joint/physiology*
;
Biomechanical Phenomena/physiology*
;
Electromyography
;
Exoskeleton Device
;
Gait/physiology*
;
Humans
;
Muscle Contraction
;
Muscle, Skeletal/physiology*
;
Walking/physiology*
3.Botulinum Toxin Type A Injection for Spastic Equinovarus Foot in Children with Spastic Cerebral Palsy: Effects on Gait and Foot Pressure Distribution.
Ja Young CHOI ; Soojin JUNG ; Dong Wook RHA ; Eun Sook PARK
Yonsei Medical Journal 2016;57(2):496-504
PURPOSE: To investigate the effect of intramuscular Botulinum toxin type A (BoNT-A) injection on gait and dynamic foot pressure distribution in children with spastic cerebral palsy (CP) with dynamic equinovarus foot. MATERIALS AND METHODS: Twenty-five legs of 25 children with CP were investigated in this study. BoNT-A was injected into the gastrocnemius (GCM) and tibialis posterior (TP) muscles under the guidance of ultrasonography. The effects of the toxin were clinically assessed using the modified Ashworth scale (MAS) and modified Tardieu scale (MTS), and a computerized gait analysis and dynamic foot pressure measurements using the F-scan system were also performed before injection and at 1 and 4 months after injection. RESULTS: Spasticity of the ankle plantar-flexor in both the MAS and MTS was significantly reduced at both 1 and 4 months after injection. On dynamic foot pressure measurements, the center of pressure index and coronal index, which represent the asymmetrical weight-bearing of the medial and lateral columns of the foot, significantly improved at both 1 and 4 months after injection. The dynamic foot pressure index, total contact area, contact length and hind foot contact width all increased at 1 month after injection, suggesting better heel contact. Ankle kinematic data were significantly improved at both 1 and 4 months after injection, and ankle power generation was significantly increased at 4 months after injection compared to baseline data. CONCLUSION: Using a computerized gait analysis and foot scan, this study revealed significant benefits of BoNT-A injection into the GCM and TP muscles for dynamic equinovarus foot in children with spastic CP.
Adolescent
;
Ankle Joint
;
Botulinum Toxins, Type A/administration & dosage/*pharmacology
;
Cerebral Palsy/*complications/drug therapy
;
Child
;
Child, Preschool
;
Clubfoot/*drug therapy/*etiology/physiopathology
;
Female
;
Foot
;
Gait/*drug effects/physiology
;
Humans
;
Injections, Intramuscular
;
Male
;
Muscle Spasticity/drug therapy
;
Muscle, Skeletal/diagnostic imaging
;
Neuromuscular Agents/administration & dosage/*pharmacology
;
Pressure
;
Prospective Studies
;
Treatment Outcome
;
Weight-Bearing
4.Brachial-Ankle Pulse Wave Velocity as a Screen for Arterial Stiffness: A Comparison with Cardiac Magnetic Resonance.
Eun Kyoung KIM ; Sung A CHANG ; Shin Yi JANG ; Ki Hong CHOI ; Eun Hee HUH ; Jung Hyun KIM ; Sung Mok KIM ; Yeon Hyeon CHOE ; Duk Kyung KIM
Yonsei Medical Journal 2015;56(3):617-624
PURPOSE: Despite technical simplicity and the low cost of brachial-ankle pulse wave velocity (BA-PWV), its use has been hampered by a lack of data supporting its usefulness and reliability. The aim of this study was to evaluate the usefulness of BA-PWV to measure aortic stiffness in comparison to using cardiovascular magnetic resonance (CMR). MATERIALS AND METHODS: A total of 124 participants without cardiovascular risk factors volunteered for this study. BA-PWV was measured using a vascular testing device. On the same day, using CMR, cross-sectional areas for distensibility and average blood flow were measured at four aortic levels: the ascending, upper thoracic descending, lower thoracic descending, and abdominal aorta. RESULTS: Compared to PWV measured by CMR, BA-PWV values were significantly higher and the differences therein were similar in all age groups (all p<0.001). There was a significant correlation between BA-PWV and PWV by CMR (r=0.697, p<0.001). Both BA-PWV and PWV by CMR were significantly and positively associated with age (r=0.652 and 0.724, p<0.001). The reciprocal of aortic distensibility also demonstrated a statistically significant positive correlation with BA-PWV (r=0.583 to 0.673, all p<0.001). CONCLUSION: BA-PWV was well correlated with central aortic PWV and distensibility, as measured by CMR, regardless of age and sex.
Adult
;
Ankle Brachial Index/*methods
;
Ankle Joint
;
Aorta/anatomy & histology/*physiology
;
*Blood Flow Velocity
;
Cardiovascular Diseases
;
Female
;
Heart/physiopathology
;
Humans
;
*Magnetic Resonance Imaging, Cine
;
Male
;
Pulse Wave Analysis/*methods
;
Regional Blood Flow
;
Reproducibility of Results
;
Risk Factors
;
*Vascular Stiffness
5.Underlying mechanisms of Tai-Chi-Chuan training for improving balance ability in the elders.
Lan-yuen GUO ; Chao-pin YANG ; Yu-lin YOU ; Shen-kai CHEN ; Chich-haung YANG ; Yi-you HOU ; Wen-lan WU
Chinese journal of integrative medicine 2014;20(6):409-415
OBJECTIVETo compare balance ability between elderly individuals who practiced Tai-Chi-Chuan (TCC) for average 9.64 years and elderly individuals who did not practice TCC and its relationship with lower extremity muscle strength and ankle proprioception.
METHODSTwenty-five elderly volunteers were divided into two groups according to their TCC practcing experience. Sixteen were TCC group and the other nine were control population. Subjects completed a static balance test and ankle proprioception test using a custom-designed evaluation system, and concentric and eccentric knee extensor and flexor muscle strength tests. Subjects stood on the plate form to measure the proprioception in functional standing position which was differed from the previous studies. Multiple linear regressions were also used to predict the important factor affecting balance.
RESULTSTCC group performed better than the control group in balance, proprioception, and muscle strength of lower extremity. The proprioception was the most important factor related to balance ability and it can be accounted for explaining 44% of variance in medial-lateral sway direction, and 53% of variance in antero-posterior sway direction. The proprioception may be a more important factor which affecting the balance ability.
CONCLUSIONTCC training is recommended to the elders; as it can improve balance ability through better proprioception.
Aged ; Ankle Joint ; physiology ; Female ; Humans ; Kinesthesis ; Linear Models ; Male ; Middle Aged ; Muscle Strength ; physiology ; Postural Balance ; physiology ; Posture ; physiology ; Proprioception ; physiology ; Tai Ji
6.Prognostic Factors after Intra-Articular Hyaluronic Acid Injection in Ankle Osteoarthritis.
Seung Hwan HAN ; Do Young PARK ; Tae Hun KIM
Yonsei Medical Journal 2014;55(4):1080-1086
PURPOSE: The goal of this study was to identify baseline prognostic factors of outcome in ankle osteoarthritis patients after intra-articular hyaluronic acid injection. MATERIALS AND METHODS: Patients with ankle osteoarthritis who received hyaluronic acid injection therapy were retrospectively reviewed. Each patient received weekly intra-articular hyaluronic acid injections (2 mL) for 3 weeks. Six predictors including gender, age, symptom duration, radiographic osteoarthritis stage, radiographic subchondral cyst, and fracture history were evaluated. Visual analogue scale (VAS) and patient satisfaction were evaluated as outcome measures. These predictors and outcome measurements were included in a logistic regression model for statistical analysis. RESULTS: Total of 40 consecutive patients (21 male, 19 female) were included in this study. Mean age was 60.6. Average follow up period was 13 months. The mean VAS recorded 3, 6, and 12 months after the first injection was 3.6 (SD 2.54, p<0.001), 4.33 (SD 2.9, p<0.001), and 5.3 (SD 2.7, p=0.0071), respectively, when compared to baseline VAS. Early stage disease was identified as an independent predictor associated with 'positive VAS outcome' at 3 and 6 months. Early stage disease and duration of pain less than 1 year were independent predictors associated with higher satisfaction. CONCLUSION: While hyaluronic acid injection for ankle osteoarthritis is a safe and effective treatment, careful selection of patients should be made according to the above prognostic predictors.
Adult
;
Aged
;
Aged, 80 and over
;
Ankle Joint/drug effects/*pathology/*physiopathology
;
Female
;
Humans
;
Hyaluronic Acid/administration & dosage/*therapeutic use
;
*Injections, Intra-Articular
;
Male
;
Middle Aged
;
Osteoarthritis/*drug therapy/pathology/physiopathology
;
Prognosis
;
Range of Motion, Articular/physiology
7.Investigation on the relationship between seat heights and performance during the sit-to-walk movement.
Jinjing ZHU ; Zhaoli MENG ; Wenxue YUAN
Journal of Biomedical Engineering 2013;30(3):518-524
DLUT4060 piezoelectric multi-component force platforms and DVM8820 three-dimensional infrared image capture system were used to test the sit-to-walk (STW) movements of 11 healthy elderly (72. 6 +/- 12. 2 years old) and 11 healthy young (19. 7 +/-1. 3 years old) individuals. Firstly, we studied the effects of seat-heights on the ground reaction forces, the velocity of the center of mass, and action time duration. Then we discussed the movement strategies and falling risks of the persons in the two age groups respectively. Finally, we decided the best seat height for the two age groups. It was found that the best seat heights for both the two age groups were 100% popliteal height. This height may make the subject get the greatest biomechanical advantages and the lowest falling risks. The popliteal height must be concerned when designing and fixing up the public activity area facilities and daily life of the elderly. To some extent, it can reduce the falling risk of the elderly.
Accidental Falls
;
prevention & control
;
Aged
;
Aged, 80 and over
;
Ankle Joint
;
physiology
;
Buttocks
;
physiology
;
Hip Joint
;
physiology
;
Humans
;
Interior Design and Furnishings
;
Knee Joint
;
physiology
;
Leg
;
anatomy & histology
;
physiology
;
Male
;
Middle Aged
;
Movement
;
physiology
;
Posture
;
Weight-Bearing
;
physiology
;
Young Adult
8.Association between improved trunk stability and walking capacity using ankle-foot orthosis in hemiparetic patients with stroke: evidence from three-dimensional gait analysis.
Yue LAN ; Guang-qing XU ; Dong-feng HUANG ; Yu-rong MAO ; Shao-zhen CHEN ; Zhong PEI ; Jin-sheng ZENG
Chinese Medical Journal 2013;126(20):3869-3873
BACKGROUNDRestoration of both normal movement of the pelvis and centre of mass is a primary goal of walking rehabilitation in post-stroke patients because these movements are essential components of effective gait. The aim of this study is to quantitatively analyze the effect of ankle-foot orthosis on walking ability, and to investigate the correlation between improvements in trunk motion and walking capacity.
METHODSWalking speed, centre of mass displacement, and pelvic movements were examined in 20 post-stroke hemiparetic patients with and without ankle-foot orthosis using three-dimensional motion analysis.
RESULTSUsing ankle-foot orthosis improved walking speed, pelvic rotation and tilt, and lateral and vertical displacements of the centre of mass (P < 0.01). Moreover, the gait asymmetry index was significantly decreased (P < 0.01), and the Functional Ambulation Categories score improved significantly when patients used an ankle-foot orthosis (P < 0.05). There was significant correlation between improvements in the walking capacity and the displacement of the centre of mass in both vertical and lateral directions (P < 0.01).
CONCLUSIONSUsing ankle-foot orthosis improves the walking capacity by improving the stability and concordant of the trunk in hemiplegic patients. The improvement in the walking capacity from using an ankle-foot orthosis may be attributed to its prevention of foot drop and compensation for the instability of the ankle joint.
Adult ; Aged ; Ankle ; physiology ; physiopathology ; Ankle Joint ; physiology ; physiopathology ; Female ; Foot Orthoses ; Gait ; physiology ; Humans ; Male ; Middle Aged ; Stroke ; physiopathology ; Walking ; physiology
9.Case-control study on bone setting manipulation for the treatment of over degree II supination-eversion fractures of ankle joint.
Yue-Feng QI ; Fa-Lin CHEN ; Shu-Ren BAO ; Cheng-Huan LI ; Xing-Wei ZHAO ; Shi-Ming LIU ; Wen-Xue CHEN ; Ye LI ; Peng WANG
China Journal of Orthopaedics and Traumatology 2012;25(8):634-638
OBJECTIVETo explore therapeutic effects of bone setting manipulation for the treatment of over degree II supination-eversion fractures of ankle,and analyze manipulative reduction mechanism.
METHODSFrom 2005 to 2008, 95 patients with over degree II supination-eversion fractures of ankle were treated respectively by manipulation and operation. There were 43 cases [11 males and 32 females with an average age of (44.95 +/- 12.65) years] in manipulation group, and 2 cases were degree II, 11 cases were degree III, and 30 cases were degree IV. There were 52 cases [21 males and 31 females with an average age of (39.96 +/- 13.28) years] in operative group,and 6 cases were degree II, 18 cases were degree III, and 28 cases were degree IV. Bone setting manipulation and hard splint external fixation were applied to manipulative group. Operative reduction internal fixation was performed in operative group. X-ray was used to evaluate reduction of fracture before and after treatment, 2 months after treatment. Ankle joint function was evaluated according to Olerud-Molander scoring system after 6 months treatment.
RESULTSAll patients were followed up with good reduction. Three cases occurred wound complication in operative group, but not in manipulative group. In manipulation group, 19 cases got excellent results, 20 cases good and 4 cases fair; while in operative group, 30 cases got excellent results, 20 cases good and 2 cases poor. There were no significant differences in fracture reduction and ankle joint function recovery between two groups (P > 0.05). Efficacy of operative treatment was better than that of manipulative treatment at degree IV fracture (P < 0.05).
CONCLUSIONBone setting manipulation is a good method for treating supination-eversion ankle joint fractures, which has advantages of simple and safe operation, reliable efficacy. For ankle join fracture at degree IV, manipulative reduction should be adopted earlier, and operative treatment also necessary
Adult ; Ankle Injuries ; physiopathology ; therapy ; Ankle Joint ; physiology ; Case-Control Studies ; Female ; Fractures, Bone ; physiopathology ; therapy ; Humans ; Male ; Manipulation, Orthopedic ; methods ; Supination
10.Micromovement characteristic of distal tibiofibular joints in normal Chinese.
Qing-Jun LIU ; Bin LIN ; Ya-Yu XU ; Zhi-Min GUO
China Journal of Orthopaedics and Traumatology 2012;25(8):627-631
OBJECTIVETo analyze micromovement of distal tihiofihular joints in different motion range of ankle joint ,and define the micromovement characteristic and range of distal tibiofihular joints.
METHODSTwelve normal Chinese were chosen. There were 9 males and 3 females, aged from 19 to 37 years old with an average (26.5 +/- 0.5) years. Detection terminals of laser photographic scanner were installed near the highest point between medial malleolus and lateral malleolos, the change of detection terminals on the position of dorsiflex, extension, introversion and eversion of ankle joint were scanned by 3D-laser scanner. The displacement of two detection terminals on the X ,Y and Z-axis (X-axis stands for the vertical-axis between coronal plane and Z-axis Y-axis stands for the vertical-axis between sagittal plane and Z-axis Z-axis stands for macroaxis of tibia).
RESULTSAlong with increased range of motion on the position of dorsiflex ,extension, introversion and eversion of ankle joint, the range of micromovement of distal tibiofibolar joints increased too. The max-displacement of X, Y and Z were respectively (1.04 +/- 0.12) mm, (1.70 +/- 0.16) mm and--(0.87 +/- 0.10) mm.
CONCLUSION3D-laser scanner can be used to determine the detailed displacement of distal tibiofibolar joint on the X , Y and Z, and measure the motion of distal tibiofibular joint. The method can be used to study the pathologic change of distal tibiofibular joint ,and provide basic biomechnics data for internal fixtor fitting for the characteristic of distal tibiofibular joint.
Adult ; Ankle Joint ; physiology ; Asian Continental Ancestry Group ; Female ; Fibula ; Humans ; Male ; Movement ; Range of Motion, Articular ; Tibia ; Young Adult

Result Analysis
Print
Save
E-mail