1.Variability of foveal avascular zone measurements among Filipino eyes using optical coherence tomography angiography
Roberto Luis F. Franco ; Carlo Antonino L. Nasol
Philippine Journal of Ophthalmology 2025;50(1):33-42
OBJECTIVE
To determine the foveal avascular zone (FAZ) thickness and other FAZ measurements in eyes of healthy Filipino adults aged 20-49 years.
METHODSThis single-center, cross-sectional, observational study evaluated 186 subjects (372 eyes) of Filipino adults 20 to 49 years of age. Using Angioplex®, the automated software of the optical coherence tomography angiography (OCTA) machine, the FAZ area, perimeter, circularity, vascular density, and perfusion in the superficial FAZ were recognized. Statistical analysis was done using SPSS version 23. The mean and standard deviation of the values of superficial capillary free zone measurements were calculated.
RESULTSThe mean FAZ area was 0.297 ± 0.112 mm2, the mean circularity was 0.667 ± 0.080, and the mean perimeter was 2.316 ± 0.80 mm. These parameters were all larger in the female population (p CONCLUSIONS
In eyes of healthy Filipino adults aged 20-49 years, females exhibited larger FAZ area, higher circularity, and lower CMT, compared to males. Additionally, females displayed lower central vessel density and perfusion. While FAZ area and perimeter remained stable with age, circularity decreased, and CMT increased.
Human ; Angiography ; Tomography, Optical Coherence
3.A prospective study of the perforator evaluation and eccentric design of anterolateral thigh flap based on superficial fascial perforators assisted by modified computed tomography angiography.
Yue Heng ZHANG ; Wen Ju CUI ; Kun Xiu SONG ; Le Gang SUN ; Fang WANG ; Xiao Zhi LIU ; Zhi Yang DENG ; Zhi Qiang ZHANG ; Yong Tao LIU
Chinese Journal of Burns 2023;39(2):141-149
Objective: To explore the preoperative whole perforator evaluation and intraoperative eccentric design of anterolateral thigh flap (ALTF) based on superficial fascial perforators by modified computed tomography angiography (CTA), and the clinical effects were observed. Methods: A prospective observational study was adopted. Twelve patients with oral and maxillofacial tumors and 10 patients with open injury of the upper limb with large soft tissue defects were hospitalized in the Department of Hand & Microsurgery and Department of Oral & Maxillofacial Surgery of Affiliated Hospital of Binzhou Medical University from January 2021 to July 2022, with 12 males and 10 females, aged from 33 to 75 years, an average age of 56.6 years. The wounds of the patients with oral and maxillofacial tumors were reconstructed by ALTF after the extensive tumor resection and radical cervical lymph node dissection in the same stage; the wounds of the patients with skin and soft tissue defect on the upper limb were covered by ALTF in stage Ⅱ after debridement in stage Ⅰ. After debridement, the area of wound was 3.5 cm×3.5 cm-25.0 cm×10.0 cm and the area of the required flap area was 4.0 cm×4.0 cm-23.0 cm×13.0 cm. Modified CTA scan was performed on the donor site of ALTF before the operation, with the parameters of modified CTA being set to mainly reduce the tube voltage and tube current, and increase the contrast dose and the dual phase scan. The acquired image data were sent to GE AW 4.7 workstation and adopted the volume reconstruction function for visual reconstruction and evaluation of the whole perforator. The information of perforator and source artery was marked on the body surface before operation according to the above evaluation. During the operation, an eccentric flap centered on the visible superficial fascia whole perforator was designed and cut according to the desired flap area and shape. The donor sites of the flap were repaired by direct sutures or full-thickness skin grafts. The total radiation dose was compared between the modified CTA scan and the traditional CTA scan. The distribution of outlet point of perforator of double thighs, the length and direction of superficial fascia perforators based modified CTA were recorded. The type, number, and origin of the target perforator, distribution of of outlet point of perforator, and the diameter, course, and branch of the source artery observed before the operation were compared with those observed during the operation. The healing of donor site wound and the survival of flaps in recipient site were observed after operation. The texture and appearance of flap, oral and upper limb functions, and the functions of femoral donor sites were followed up. Results: The total radiation dose of modified CTA scan was lower than that of the traditional CTA scan. A total of 48 perforators of double thighs were observed, among which, 31 (64.6%) perforators went outward and downward, 9 (18.8%) perforators went inward and downward, 6 (12.5%) perforators went outward and upward, and 2 (4.2%) perforators went inward and upward, and the average length of superficial fascia perforators was 19.94 mm. The preoperative observed type, number, and source of the perforator, the distribution of the outlet point of the perforator, diameter, course, and branches of the source artery were basically consistent with the intraoperative exploration. The types of 15 septocutaneous (including musculoseptocutaneous) perforators and 10 musculocutaneous perforators observed before the operation was consistent with intraoperative exploration. The distance between the mark of the surface perforator point and the actual exit point of the perforator during operation was (0.38±0.11) mm. All flaps survived without vascular crisis. The donor site wounds of 5 cases of skin grafting and 17 cases of direct suturing wounds healed well. The postoperative follow-up was 2 months to 1 year, with an average of 8.2 months, the flaps were soft and slightly bloated; the function of diet and mouth closing was accessible in patients with oral and maxillofacial tumors, the speech function was mildly impaired in patients with tongue cancer, but they could complete basic oral communication; the wrist and elbow joints and forearm rotation function were not significantly limited in patients with upper limb soft tissue injuries; there was no obvious tightness in the donor sites, and the function of the hip and knee joints was not limited. Conclusions: The whole perforator and even the subcutaneous perforator of the donor site of ALTF can be evaluated by modified CTA, and the flap can be used in oral or maxillofacial reconstruction and repair of skin and soft tissue defects of upper limbs to achieve good results. By clarifying the type, number, and source of the perforator, the distribution of the outlet point of the perforator, diameter, course, and branches of the source artery before the operation, the eccentric design of the ALTF based on the superficial fascia perforator was realized. This study has strong guiding value.
Female
;
Male
;
Humans
;
Middle Aged
;
Adult
;
Aged
;
Thigh
;
Computed Tomography Angiography
;
Prospective Studies
;
Subcutaneous Tissue
;
Tomography, X-Ray Computed
4.Application of Three-dimensional Computed Tomography Bronchography and Angiography Combined with Perfusion Area Identification Technique in Uniport Thoracoscopic Complex Segmentectomy.
Yuanbo LI ; Yi ZHANG ; Xiuyi ZHI ; Lei SU ; Baodong LIU
Chinese Journal of Lung Cancer 2023;26(1):17-21
BACKGROUND:
With the extensive application of segmental lung resection in the treatment of early-stage lung cancer, how to complete segmentectomy more accurately and minimally invasively has become a research hotspot. The aim of this study is to explore the application of three-dimensional computed tomography bronchography and angiography (3D-CTBA) combined with perfusion area recognition technique in single-hole thoracoscopic complex segmentectomy.
METHODS:
From January 2021 to January 2022, the clinical data of 112 consecutive patients undergoing single-port thoracoscopic complex segmentectomy in the Department of Thoracic Surgery, Xuanwu Hospital, Capital Medical University were retrospectively analyzed. The three-dimensional reconstruction combined with perfusion area identification technique was used to perform the operation and the clinical data were analyzed.
RESULTS:
The average operation time was (141.1±35.4) min; the initial time of intersegmental plane display was (12.5±1.7) s; the maintenance time of intersegmental plane was (114.3±10.9) s; the intersegmental plane was clearly displayed (100%); the amount of bleeding was [10 (10, 20)] mL; the total postoperative drainage volume was (380.5±139.7) mL; the postoperative extubation time was (3.9±1.2) d; and the postoperative hospitalization time was (5.2±1.6) d. Postoperative complications occurred in 8 cases.
CONCLUSIONS
The advantages of 3D-CTBA combined with perfusion area recognition technique are fast, accurate and safe in identifying intersegmental boundary in single-port thoracoscopic complex segmentectomy, which could provide guidances for accuratding resection of tumors, shortening operation time and reducing surgical complications.
Humans
;
Lung Neoplasms/pathology*
;
Bronchography
;
Pneumonectomy/methods*
;
Retrospective Studies
;
Thoracic Surgery, Video-Assisted/methods*
;
Tomography, X-Ray Computed
;
Angiography/methods*
;
Perfusion
5.Clinical application of Neuroform Atlas stent-assisted coiling in the treatment of unruptured wide-neck intracranial aneurysms.
Jin Tao HAN ; Yu Xiang ZHANG ; Zi Chang JIA ; Chu Han JIANG ; Lian LIU ; Jing Yuan LUAN ; Fei LIANG ; Yan Qing ZHAO
Journal of Peking University(Health Sciences) 2023;55(1):139-143
OBJECTIVE:
To assess the safety and efficacy of Neuroform Atlas stent used in treatment of unruptured wide-neck intracranial aneurysms.
METHODS:
Clinical data of 62 patients with unruptured wide-neck intracranial aneurysms undergoing Neuroform Atlas stent-assisted coiling from August 2020 to September 2021 were retrospectively analyzed. There were 64 aneurysms in those 62 patients. Among them, 25 aneurysms were located at the bifurcation of M1 segment on middle cerebral artery, 16 at the anterior communicating artery, 10 at the C7 segment of internal carotid artery, 5 at the C6 segment of internal carotid artery, 4 at the apex of basilar artery, 3 at the A3 segment of anterior cerebral artery, and 1 at the M2 segment of middle cerebral artery. All the patients underwent Neuroform Atlas stent-assisted coiling, including 49 patients with single stent assisted coiling and 15 patients with dual stents assisted coiling (14"Y"style and 1"X"style). After the procedure, the immediate DSA was performed to evaluate the status of aneurysm occlusion and the parent artery patency. The clinical follow-up was performed 3 months after the operation and evaluated based on the modified Rankin Scale(mRS).DSA image was reviewed at 6 months after operation and Raymond grading scale was used to assess the status of aneurysm occlusion and the parent artery patency.
RESULTS:
A total of 62 patients with 64 aneurysms were all achieved technical success(100%).The immediate post-procedural Raymond scale was assessed, including Raymond Ⅰ in 57 aneurysms(89.1%, 57/64), Raymond Ⅱ in 6 aneurysms(9.3%, 6/64) and Raymond Ⅲ in 1 aneurysm(1.6%, 1/64). The peri-procedural complications rate was 4.8%(3/62), 2 patients developed intraoperative thrombosis and 1 patient suffered from local subarachnoid hemorrhage. Among them, 55 patients obtained 3 months clinical follow-up after operation and all the patients had good outcomes (mRS≤2), 50 patients with 52 aneurysms were followed up with DSA 6 months after operation, including Raymond Ⅰ in 45 aneurysms(86.5%, 45/52), Raymond Ⅱ in 4 aneurysms(7.7%, 4/52) and Raymond Ⅲ in 3 aneurysms(5.8%, 3/52).
CONCLUSION
Neuroform Atlas stent for the treatment of unruptured wide-neck intracranial aneurysms has high safety and good efficacy, and has its advantages over other traditional stents.
Humans
;
Intracranial Aneurysm/etiology*
;
Retrospective Studies
;
Treatment Outcome
;
Embolization, Therapeutic/methods*
;
Stents/adverse effects*
;
Cerebral Angiography
6.The effect of fluorescein angiography on renal function: A meta-analysis and systematic review
Kevin Elissandro C. Gumabon ; Paolo Nikolai H. So ; Anne Margaret J. Ang
Acta Medica Philippina 2023;57(3):42-49
Background:
Contrast-induced nephropathy (CIN) is a complication that occurs in patients undergoing an imaging procedure with intravenous injection of contrast media, most notably iodinated dyes. Fluorescein angiography is a diagnostic procedure performed by ophthalmologists to determine abnormalities in retinal blood vessels. It uses sodium fluorescein, an organic dye, to capture and visualize these blood vessels. There have been conflicting data and practices on how to approach the procedure especially in patients with renal insufficiency.
Objective:
To determine the risk of CIN among patients undergoing fluorescein angiography.
Methods:
We searched PubMed, HerdIn, Cochrane Library, and Google Scholar, for published articles on the
topic. Other sources were searched for unpublished data or ongoing clinical trials. All research articles pertaining to fluorescein angiography and its effect on renal function with serum creatinine monitoring were included. Two independent authors separately screened records, assessed full texts, and extracted data. We used RevMan computer software to analyze data from the included studies. The primary outcome was the risk of CIN among patients undergoing fluorescein angiography based on the differences on serum creatinine levels and estimated glomerular filtration rates pre- and post-angiography, while the secondary outcome included risk factors for CIN.
Results:
A total of 6 studies were included in the meta-analysis. Four studies had poor quality as assessed using the Newcastle-Ottawa Scale. One study was deemed to have good quality. Data analysis showed that hemoglobin (p = 0.002) and albumin (p < 0.001) levels may be associated with CIN using sodium fluorescein but were not independent risk factors for CIN (multivariable logistic regression, p = 0.648 and p = 0.069, respectively); while sex, diabetes mellitus and chronic kidney disease were not significantly associated. As a primary outcome, only 6.8% of included patients had CIN with serum creatinine levels post-exposure showed significant differences from baseline values (mean difference 0.05; 95% CI 0.02, 0.07; I2 = 49%), but translating it to eGFR yielded non-significant differences (mean difference -0.37; 95% CI -2.33, 1.59; I2 = 0%).
Conclusion
Among patients undergoing fluorescein angiography, sodium fluorescein does not pose an increased risk for CIN.
fluorescein angiography
;
renal function
7.Quality of Images Reconstructed by Deep Learning Reconstruction Algorithm for Head and Neck CT Angiography at 100 kVp.
Xiao-Ping LU ; Yun WANG ; Yu CHEN ; Yan-Ling WANG ; Min XU ; Zheng-Yu JIN
Acta Academiae Medicinae Sinicae 2023;45(3):416-421
Objective To evaluate the impact of deep learning reconstruction algorithm on the image quality of head and neck CT angiography (CTA) at 100 kVp. Methods CT scanning was performed at 100 kVp for the 37 patients who underwent head and neck CTA in PUMC Hospital from March to April in 2021.Four sets of images were reconstructed by three-dimensional adaptive iterative dose reduction (AIDR 3D) and advanced intelligent Clear-IQ engine (AiCE) (low,medium,and high intensity algorithms),respectively.The average CT value,standard deviation (SD),signal-to-noise ratio (SNR),and contrast-to-noise ratio (CNR) of the region of interest in the transverse section image were calculated.Furthermore,the four sets of sagittal maximum intensity projection images of the anterior cerebral artery were scored (1 point:poor,5 points:excellent). Results The SNR and CNR showed differences in the images reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D (all P<0.01).The quality scores of the image reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D were 4.78±0.41,4.92±0.27,4.97±0.16,and 3.92±0.27,respectively,which showed statistically significant differences (all P<0.001). Conclusion AiCE outperformed AIDR 3D in reconstructing the images of head and neck CTA at 100 kVp,being capable of improving image quality and applicable in clinical examinations.
Humans
;
Computed Tomography Angiography/methods*
;
Radiation Dosage
;
Deep Learning
;
Radiographic Image Interpretation, Computer-Assisted/methods*
;
Signal-To-Noise Ratio
;
Algorithms
8.Value of fractional flow reserve derived from coronary computed tomographic angiography and plaque quantitative analysis in predicting adverse outcomes of non-obstructive coronary heart disease.
Jun LIU ; Yong WU ; Hong HUANG ; Peng WANG ; Qinghua WU ; Hongyan QIAO
Chinese Critical Care Medicine 2023;35(6):615-619
OBJECTIVE:
To investigate the value of coronary computed tomographic angiography (CCTA)-based fractional flow reserve (CT-FFR) and plaque quantitative analysis in predicting adverse outcomes in patients with non-obstructive coronary heart disease (CAD).
METHODS:
Clinical data of patients with non-obstructive CAD who underwent CCTA at the Affiliated Hospital of Jiangnan University from March 2014 to March 2018 were retrospectively analyzed and followed up, and the occurrence of major adverse cardiovascular event (MACE) was recorded. The patients were divided into MACE and non-MACE groups according to the occurrence of MACE. The clinical data, CCTA plaque characteristics including plaque length, stenosis degree, minimum lumen area, total plaque volume, non-calcified plaque volume, calcified plaque volume, plaque burden (PB) and remodelling index (RI), and CT-FFR were compared between the two groups. Multivaritate Cox proportional risk model was used to evaluate the relationship between clinical factors, CCTA parameters and MACE. The receiver operator characteristic curve (ROC curve) was used to assess the predictive power of outcome prediction model based on different CCTA parameters.
RESULTS:
Finally 217 patients were included, of which 43 (19.8%) had MACE and 174 (80.2%) did not. The median follow-up interval was 24 (16, 30) months. The CCTA showed that patients in the MACE group had more severe stenosis than that in the non-MACE group [(44.3±3.8)% vs. (39.5±2.5)%], larger total plaque volume and non-calcified plaque volume [total plaque volume (mm3): 275.1 (197.1, 376.9), non-calcified plaque volume (mm3): 161.5 (114.5, 307.8) vs. 117.9 (77.7, 185.5)], PB and RI were larger [PB: 50.2% (42.1%, 54.8%) vs. 45.1% (38.2%, 51.7%), RI: 1.19 (0.93, 1.29) vs. 1.03 (0.90, 1.22)], CT-FFR value was lower [0.85 (0.80, 0.88) vs. 0.92 (0.87, 0.97)], and the differences were statistically significant (all P < 0.05). Cox regression analysis showed that non-calcified plaques volume [hazard ratio (HR) = 1.005. 95% confidence interval (95%CI) was 1.025-4.866], PB ≥ 50% (HR = 3.146, 95%CI was 1.443-6.906), RI ≥ 1.10 (HR = 2.223, 95%CI was 1.002-1.009) and CT-FFR ≤ 0.87 (HR = 2.615, 95%CI was 1.016-6.732) were independent predictors of MACE (all P < 0.05). The model based on CCTA stenosis degree+CT-FFR+quantitative plaque characteristics (including non-calcified plaque volume, RI, PB) [area under the ROC curve (AUC) = 0.91, 95%CI was 0.87-0.95] had significantly better predictive efficacy for adverse outcomes than the model based on CCTA stenosis degree (AUC = 0.63, 95%CI was 0.54-0.71) and the model based on CCTA stenosis degree+CT-FFR (AUC = 0.71, 95%CI was 0.63-0.79; both P < 0.01).
CONCLUSIONS
CT-FFR and plaque quantitative analysis based on CCTA are helpful in predicting adverse outcomes in patients with non-obstructive CAD. Non-calcified plaque volume, RI, PB and CT-FFR are important predictors of MACE. Compared with the prediction model based on stenosis degree and CT-FFR, the combined plaque quantitative index can significantly improve the prediction efficiency of adverse outcomes in patients with non-obstructive CAD.
Humans
;
Fractional Flow Reserve, Myocardial
;
Coronary Angiography/methods*
;
Constriction, Pathologic
;
Retrospective Studies
;
ROC Curve
;
Predictive Value of Tests
;
Plaque, Atherosclerotic/diagnostic imaging*
;
Coronary Stenosis/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Coronary Artery Disease/diagnostic imaging*
9.Comparison of CT Values between Thrombus and Postmortem Clot Based on Cadaveric Pulmonary Angiography.
Zhi-Ling TIAN ; Ruo-Lin WANG ; Jian-Hua ZHANG ; Ping HUANG ; Zhi-Qiang QIN ; Zheng-Dong LI ; He-Wen DONG ; Dong-Hua ZOU ; Mao-Wen WANG ; Zhuo LI ; Lei WAN ; Xiao-Tian YU ; Ning-Guo LIU
Journal of Forensic Medicine 2023;39(1):7-12
OBJECTIVES:
To explore the difference in CT values between pulmonary thromboembolism and postmortem clot in postmortem CT pulmonary angiography (CTPA) to further improve the application value of virtual autopsy.
METHODS:
Postmortem CTPA data with the definite cause of death from 2016 to 2019 were collected and divided into pulmonary thromboembolism group (n=4), postmortem clot group (n=5), and control group (n=5). CT values of pulmonary trunk and left and right pulmonary artery contents in each group were measured and analyzed statistically.
RESULTS:
The average CT value in the pulmonary thromboembolism group and postmortem clot group were (168.4±53.8) Hu and (282.7±78.0) Hu, respectively, which were lower than those of the control group (1 193.0±82.9) Hu (P<0.05). The average CT value of the postmortem clot group was higher than that of the pulmonary thromboembolism group (P<0.05).
CONCLUSIONS
CT value is reliable and feasible as a relatively objective quantitative index to distinguish pulmonary thromboembolism and postmortem clot in postmortem CTPA. At the same time, it can provide a scientific basis to a certain extent for ruling out pulmonary thromboembolism deaths.
Humans
;
Autopsy
;
Thrombosis
;
Pulmonary Embolism/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Angiography
;
Cadaver
10.Clinical efficacy of Kuanxiong aerosol in the treatment of coronary microvascular disease assessed by coronary angiography-derived index of microcirculatory resistance: three cases report.
Bei Li XIE ; Ming Wang LIU ; Bo Ce SONG ; Yu Long BIE ; Fu Hai ZHAO
Chinese Journal of Cardiology 2023;51(4):415-417


Result Analysis
Print
Save
E-mail