1.Correlation of cone- and rod-derived retinal nonperfusion on ultrawide field fluorescein angiography with diabetic retinopathy severity and diabetic macular edema.
Recivall P. Salongcay ; Anna Karina D. Leopando ; Lizzie Anne C. Aquino ; Tunde Peto ; Paolo S. Silva
Philippine Journal of Ophthalmology 2026;51(1):26-33
OBJECTIVE
To evaluate cone- and rod-specific nonperfusion indices (CPI, RPI) on ultrawide field fluorescein angiography (UWF-FA) and their correlation with diabetic retinopathy (DR) severity and center-involving diabetic macular edema (ciDME).
METHODSSixty-nine eyes of 43 patients with diabetes underwent UWF color photography (UWF-CP), UWF-FA, and macular optical coherence tomography (OCT). DR severity was graded by a masked reader on UWF-CP. UWFFA images were segmented into posterior pole (≤10 mm from fovea), mid-periphery (10–15 mm) and far periphery (>15 mm), and into the macula, within ETDRS fields and extended peripheral fields. Ischemic areas were quantified using ImageJ to calculate nonperfusion index (NPI), CPI, and RPI. ciDME was determined on OCT. Correlations were analyzed using Pearson coefficients (r).
RESULTSDR severity correlated significantly with global NPI (r = 0.56, p < 0.0001) and across all retinal zones (r = 0.35– 0.57). Both CPI (global: r = 0.56, p < 0.0001; zones: r = 0.42–0.59) and RPI (global: r = 0.55, p < 0.0001; zones: r = 0.40–0.59) showed similar associations. ciDME presence was also correlated with NPI (global: r = 0.40, p = 0.0014; zones: r = 0.42–0.54), CPI (global: r = 0.47, p = 0.0001; zones: r = 0.32–0.55), and RPI (global: r = 0.46, p = 0.0002; zones: r = 0.33–0.54).
CONCLUSIONSCone- and rod-related retinal nonperfusion strongly correlate with DR severity and ciDME. UWF-FA may help identify high-risk eyes and guide surveillance of ischemia-related progression. Further studies are needed to define ischemic thresholds predictive of vision-threatening complications.
Human ; Diabetic Retinopathy ; Photoreceptor Cells, Vertebrate ; Rods And Cones ; Fluorescein Angiography ; Macular Edema ; Retinaldehyde
2.Spontaneous spinal epidural hematoma treated nonsurgically in a Philippine tertiary hospital: A case report.
Louie Lorenzo M. Alcantara ; Ramon Carlos Miguel L. Alemany
Philippine Journal of Neurology 2026;29(1):14-18
Spontaneous spinal epidural hematomas (SSEH) is a rare entity with an estimated incidence of 0.1 in 100,000, defined as a an epidural hematoma without any known inciting events such as trauma or an iatrogenic procedure. Currently, there are no local data pertaining to this disease entity. This paper presents a case of a 52 year old male, without any known comorbid coagulopathies or vasculopathies, and no preceding history of trauma or surgical procedures with sudden onset right-sided radicular pain and hemiparesis with left-sided hemianesthesia with spinal MRI findings of a spinal epidural hematoma but no vascular malformations seen on spinal angiogram. He was managed non-surgically, given short-course steroids, and sent home after 7 days in the hospital. There was no noted progression of his baseline deficits nor any recurrence of another acute spinal event. Upon follow up after 6 months, there was noted resolution of weakness and with only residual mild and patchy sensory deficit on the left. Traditionally treated surgically, this case reports highlights the role of conservative management in this rare condition with good functional outcome.
Human ; Male ; Middle Aged: 45-64 Yrs Old ; Surgical Procedures, Operative ; Hematoma, Epidural, Spinal ; Vascular Malformations ; Paresis ; Angiography ; Hematoma
3.Renal autotransplantation for the treatment of complex renal aneurysm in a child: A case report.
Lei YU ; Wenbo YANG ; Yufan YANG ; Qiang WANG
Journal of Peking University(Health Sciences) 2025;57(2):396-399
Renal autotransplantation (RA) offers significant technical advantages for the management of certain complex renal vascular diseases, such as complex renal aneurysms and renal artery malformations. This report describes a case of a 5-year-old child with a complex left renal artery aneurysm combined with multiple aneurysms. The child was admitted to Peking University People's Hospital in December 2023 due to a one-year history of intermittent abdominal pain, with an abdominal mass detected in the past month. Computed tomography angiography(CTA) revealed multiple vascular anomalies, including: (1) a left renal artery aneurysm, (2) an abdominal aortic aneurysm, and (3) a right iliac artery aneurysm. After a comprehensive evaluation of these findings, the surgical team developed a treatment plan that involved the excision of the left renal artery aneurysm, autotransplantation of the left kidney, and resection of the abdominal aortic aneurysm with an artificial vascular catheterization. During surgery, it was discovered that the left renal artery anatomy was highly complex. The artery had two primary branches, along with an additional polar artery located at the lower pole. The aneurysm was identified at the distal end of the renal artery trunk, with a pronounced bulging at the intersection between the main renal artery trunk and its secondary branches. Due to these structural complexities, the team decided to use an ex vivo surgical approach to repair the aneurysm. Ex vivo repair involves temporarily removing the kidney from the body to repair the renal artery aneurysm with enhanced precision, enabling the surgical team to meticulously reconstruct the complex vascular architecture without the constraints of in vivo manipulation. The ex vivo repair of the renal artery aneurysm was successful, allowing for accurate vascular reconstruction and avoiding potential intraoperative complications. Following the reconstruction, the kidney was autotransplanted back into the child's body, and blood flow was effectively restored to the organ. The therapeutic outcome was excellent, with the child experiencing no postoperative complications. The patient recovered well and was discharged from the hospital in stable condition. This case underscores the value of renal autotransplantation combined with ex vivo repair for pediatric patients with complicated renal artery aneurysms. Through this report, we aim to provide insights and considerations for the surgical treatment of similar cases in children with complex renal vascular anatomy.
Child, Preschool
;
Humans
;
Aneurysm/surgery*
;
Aortic Aneurysm, Abdominal/diagnostic imaging*
;
Computed Tomography Angiography
;
Iliac Aneurysm/surgery*
;
Kidney Transplantation/methods*
;
Renal Artery/abnormalities*
;
Transplantation, Autologous
4.Exploration of Rational Use of DSA Equipment in IoT and Clinical Service.
Jie YANG ; Xiaomin REN ; Jinning ZHANG
Chinese Journal of Medical Instrumentation 2025;49(2):186-190
OBJECTIVE:
This study aims to address the configuration and efficiency issues in the use of digital subtraction angiography (DSA) equipment through the practical implementation of a rationalization platform based on the Internet of Things (IoT).
METHODS:
By employing IoT and data integration technologies, the deep integration of DSA equipment operational data with clinical data was achieved to construct a knowledge base for rational use of DSA equipment. Simultaneously, a knowledge base was developed using software engineering techniques to visually display data analysis results.
RESULTS:
Through thorough data analysis, an imbalance in DSA usage between the southern and northern hospital campuses was identified. Addressing this issue, optimizations were implemented based on the data analysis results, which ultimately yielded significant effects. These adjustments not only effectively alleviated the pressure on DSA equipment usage in the southern campus, but also increased equipment utilization in the northern district (the average daily working hours have increased from 4.64 h to 7.19 h), shortened patient appointment wait time (the appointment duration in the southern campus decreased by 21.86% year-on-year, while the appointment duration in the northern campus decreased by 20.51% year-on-year).
CONCLUSION
Through the practical implementation of a DSA rationalization platform based on IoT, this study not only successfully explored methods for rational DSA usage but also provided valuable reference for the rational management of medical equipment.
Internet of Things
;
Angiography, Digital Subtraction/instrumentation*
;
Humans
;
Software
5.Multidetector computed tomography angiography for diagnosis of traumatic aneurysms associated with penetrating head injuries.
Konstantin Nickolaevich BABICHEV ; Aleksandr Viktorovich SAVELLO ; Alla Vladimirovna ISAEVA ; Dmitrij Vladimirovich SVISTOV ; Igor' Anatol'evich MEN'KOV ; Dzhamaludin Magomedrasulovich ISAEV
Chinese Journal of Traumatology 2025;28(2):91-95
PURPOSE:
To analyze the diagnostic efficacy of computed tomography angiography compared to digital cerebral angiography for the diagnosis of traumatic aneurysms (TAs) associated with combat-related penetrating head injuries and propose the most suitable angiography protocol in this clinical context.
METHODS:
A retrospective analysis was conducted on patients admitted to the neurosurgical clinic for penetrating traumatic brain injuries between February, 2022 and July, 2024, for whom both cerebral multidetector computed tomography angiography (MCTA) and digital cerebral angiography (DCA) were available. The inclusion were patients (1) with penetrating head injuries, (2) with missile trajectory traverses through the Sylvian or great longitudinal fissure, (3) basal cisterns with/or major subarachnoid hemorrhage. The sensitivity, specificity, positive predictive value, and negative predictive value of MCTA were calculated. DCA was considered as the gold standard of diagnosis. The sensitivity, specificity, positive predictive value, and negative predictive value of MCTA were calculated. Descriptive statistics and nonparametric statistics were used to analyze the study results and their differences, respectively.
RESULTS:
A total of 40 patients with 45 TAs were included in the study. Of these, 26 patients (65.0%) were found to have aneurysms on MCTA. The median diameter of the aneurysms diagnosed by MCTA was 4.9 (3.6, 4.8) mm (range of 2.5 - 10.4 mm). However, the mean diameter of TAs not detected by MCTA but diagnosed by DCA was (3.0 ± 1.3) mm (range of 1.3 - 4.9 mm). MCTA demonstrated sensitivity and specificity of 35.5% and 99.5%, respectively, with positive and negative predictive values of 92.3% and 90.7%.
CONCLUSIONS
A low sensitivity of MCTA for the diagnosis of TAs associated with combat-related penetrating head injuries was reported. When MCTA is inconclusive in the setting of radiologic predictors of cerebral artery injury, DSA may be required.
Humans
;
Male
;
Retrospective Studies
;
Adult
;
Multidetector Computed Tomography/methods*
;
Intracranial Aneurysm/etiology*
;
Computed Tomography Angiography/methods*
;
Female
;
Head Injuries, Penetrating/diagnostic imaging*
;
Middle Aged
;
Cerebral Angiography/methods*
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Young Adult
6.Predicting late aortic complications after acute type A dissection surgery with volumetric measurements in a Singapore cohort.
Jasmine GE ; Vinay Bahadur PANDAY ; Siew-Pang CHAN ; Bernard WEE ; Julian Chi Leung WONG ; Leok Kheng Kristine TEOH ; Moe Thu SAN ; Carlos A MESTRES ; Theodoros KOFIDIS ; Vitaly A SOROKIN
Singapore medical journal 2025;66(9):469-475
INTRODUCTION:
This study was conducted to evaluate the efficacy of postoperative computed tomography (CT) measurements of aortic lumen volumes in predicting aortic-related complications following acute type A aortic dissection (ATAAD) repair.
METHODS:
We conducted a single-institution retrospective aortic volumetric analysis of patients after ascending aorta replacement performed during 2001-2015. The volumetric measurements of total lumen (total-L), true lumen (TL), false lumen (FL), as well as the TL:FL ratio from the first and second postoperative computer angiograms were obtained. A generalised structural equation model was created to analyse the predictive utility of TL:FL ratio.
RESULTS:
One hundred and twenty-five patients underwent surgical intervention, of whom 97 patients were eventually discharged and analysed for postoperative complications. A total of 19 patients were included in the final analysis. Patients with late postoperative aortic complications had a significantly higher FL volume and total-L volume on the first (FL volume P = 0.041, total-L volume P = 0.05) and second (FL volume P = 0.01, total-L volume P = 0.007) postoperative scans. The odds of having aortic complications were raised by 1% with a 1 cm 3 increase in total-L volume and by 2% with a 1 cm 3 increase in FL volume. The TL:FL ratio was significantly lower in patients who developed complications.
CONCLUSION
Postoperative CT volumetric measurements in patients who developed complications are characterised by a significant increase in the FL volume and total-L volume from the first postoperative scans. Patients with disproportionately expanded FL presenting with TL:FL ratios less than 1 were associated with aortic complications. Hence, the TL:FL ratio may be a reliable and useful parameter to monitor postoperative disease progression and to evaluate the risk of late complications in ATAAD patients.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Singapore
;
Aortic Dissection/diagnostic imaging*
;
Middle Aged
;
Postoperative Complications/diagnostic imaging*
;
Aged
;
Tomography, X-Ray Computed
;
Aortic Aneurysm/diagnostic imaging*
;
Aorta/surgery*
;
Adult
;
Treatment Outcome
;
Computed Tomography Angiography
7.Cost-effectiveness of angiographic quantitative flow ratio-guided coronary intervention: A multicenter, randomized, sham-controlled trial.
Yanyan ZHAO ; Changdong GUAN ; Yang WANG ; Zening JIN ; Bo YU ; Guosheng FU ; Yundai CHEN ; Lijun GUO ; Xinkai QU ; Yaojun ZHANG ; Kefei DOU ; Yongjian WU ; Weixian YANG ; Shengxian TU ; Javier ESCANED ; William F FEARON ; Shubin QIAO ; David J COHEN ; Harlan M KRUMHOLZ ; Bo XU ; Lei SONG
Chinese Medical Journal 2025;138(10):1186-1193
BACKGROUND:
The FAVOR (Comparison of Quantitative Flow Ratio Guided and Angiography Guided Percutaneous Intervention in Patients with Coronary Artery Disease) III China trial demonstrated that percutaneous coronary intervention (PCI) lesion selection using quantitative flow ratio (QFR) measurement, a novel angiography-based approach for estimating fractional flow reserve, improved two-year clinical outcomes compared with standard angiography guidance. This study aimed to assess the cost-effectiveness of QFR-guided PCI from the perspective of the current Chinese healthcare system.
METHODS:
This study is a pre-specified analysis of the FAVOR III China trial, which included 3825 patients randomized between December 25, 2018, and January 19, 2020, from 26 centers in China. Patients with stable or unstable angina pectoris or those ≥72 hours post-myocardial infarction who had at least one lesion with a diameter stenosis between 50% and 90% in a coronary artery with a ≥2.5 mm reference vessel diameter by visual assessment were randomized to a QFR-guided strategy or an angiography-guided strategy with 1:1 ratio. During the two-year follow-up, data were collected on clinical outcomes, quality-adjusted life-years (QALYs), estimated costs of index procedure hospitalization, outpatient cardiovascular medication use, and rehospitalization due to major adverse cardiac and cerebrovascular events (MACCE). The primary analysis calculated the incremental cost-effectiveness ratio (ICER) as the cost per MACCE avoided. An ICER of ¥10,000/MACCE event avoided was considered economically attractive in China.
RESULTS:
At two years, the QFR-guided group demonstrated a reduced rate of MACCE compared to the angiography-guided group (10.8% vs . 14.7%, P <0.01). Total two-year costs were similar between the groups (¥50,803 ± 21,121 vs . ¥50,685 ± 23,495, P = 0.87). The ICER for the QFR-guided strategy was ¥3055 per MACCE avoided, and the probability of QFR being economically attractive was 64% at a willingness-to-pay threshold of ¥10,000/MACCE avoided. Sensitivity analysis showed that QFR-guided PCI would become cost-saving if the cost of QFR were below ¥3682 (current cost: ¥3800). Cost-utility analysis yielded an ICER of ¥56,163 per QALY gained, with a 53% probability of being cost-effective at a willingness-to-pay threshold of ¥85,000 per QALY gained.
CONCLUSION:
In patients undergoing PCI, a QFR-guided strategy appears economically attractive compared to angiographic guidance from the perspective of the Chinese healthcare system.
TRIAL REGISTRATION
ClinicalTrials.gov , NCT03656848.
Humans
;
Cost-Benefit Analysis
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Angiography/methods*
;
Middle Aged
;
Aged
;
Coronary Artery Disease/surgery*
;
Quality-Adjusted Life Years
;
Fractional Flow Reserve, Myocardial/physiology*
8.An adaptive multi-label classification model for diabetic retinopathy lesion recognition.
Xina LIU ; Jun XIE ; Junjun HOU ; Xinying XU ; Yan GUO
Journal of Biomedical Engineering 2025;42(5):892-900
Diabetic retinopathy is a common blinding complication in diabetic patients. Compared with conventional fundus color photography, fundus fluorescein angiography can dynamically display retinal vessel permeability changes, offering unique advantages in detecting early small lesions such as microaneurysms. However, existing intelligent diagnostic research on diabetic retinopathy images primarily focuses on fundus color photography, with relatively insufficient research on complex lesion recognition in fluorescein angiography images. This study proposed an adaptive multi-label classification model (D-LAM) to improve the recognition accuracy of small lesions by constructing a category-adaptive mapping module, a label-specific decoding module, and an innovative loss function. Experimental results on a self-built dataset demonstrated that the model achieved a mean average precision of 96.27%, a category F1-score of 91.21%, and an overall F1-score of 94.58%, with particularly outstanding performance in recognizing small lesions such as microaneurysms (AP = 1.00), significantly outperforming existing methods. The research provides reliable technical support for clinical diagnosis of diabetic retinopathy based on fluorescein angiography.
Diabetic Retinopathy/diagnostic imaging*
;
Humans
;
Fluorescein Angiography
;
Microaneurysm/diagnostic imaging*
;
Retinal Vessels
;
Algorithms
9.Imaging anatomy study on utilizing uncinate process "inflection point" as a landmark for anterior cervical spine decompression surgery.
Jianfeng JIANG ; Jun MA ; Maoyu YANG ; Yaozheng HAN ; Lintao SU ; Changyu LEI ; Chenguang GE ; Hui KANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):332-340
OBJECTIVE:
To explore the anatomical parameters of the cervical uncinate process "inflection point" through cervical CT angiography (CTA) and MRI measurements, offering a reliable and safe anatomical landmark for anterior cervical decompression surgery.
METHODS:
A retrospective analysis was conducted on the cervical CTA and MRI imaging data of normal adults who met the selection criteria between January 2020 and January 2024. The CTA dataset included 326 cases, with 200 males and 126 females, aged 22-55 years (mean, 46.7 years). The MRI dataset included 300 cases, with 200 males and 100 females, aged 18-55 years (mean, 43.7 years). Based on the CTA data, three-dimensional models of C 3-C 7 were constructed, and the following measurements were obtained from the superior view: uncinate process "inflection point" to vertebral artery distance (UIVD), uncinate process tip to vertebral artery distance (UTVD), uncinate process "inflection point" to "inflection point" distance (UID), uncinate process long-axis to sagittal angle (ULSA), and uncinate process "inflection point" to transverse foramen-sagittal angle (UITSA). From the anterior view, the anterior uncinate process to sagittal angle (AUSA) was measured. From the posterior view, the posterior uncinate process to sagittal angle (PUSA) was measured. Based on the MRI data, uncinate process "inflection point" to dural sac distance (UIDD) and dural sac width (DSW) were measured. The trends in measurement parameters of C 3-C 7 were observed, and the differences in measurement parameters between genders and between the left and right sides of the same segment were compared, as well as the difference in UID and DSW within the same segment was compared.
RESULTS:
The measurement parameters from C 3 to C 7 in the CTA data showed a general increasing trend, with no significant difference between the left and right sides within the same segment ( P>0.05). The UIVD, UTVD, and UID were greater in males than in females, with significant differences observed in the UIVD and UTVD at C 3 and C 6 and UID at C 3, C 6, and C 7 ( P<0.05). The MRI measured DSW showed a general increasing trend from C 3 to C 7, and the DSW at C 6 was greater in females than in males, with a significant difference ( P<0.05). The UIDD showed a gradual decreasing trend, with the smallest value at C 6. There was no significant difference between males and females or between the left and right sides within the same segment ( P>0.05). The UID was greater than the DSW at C 3-C 7, and the differences were significant ( P<0.05).
CONCLUSION
The uncinate process "inflection point" is a constant anatomical structure located at the anteromedial aspect of the uncinate process tip and laterally to the dural sac. It maintains a certain safe distance from the vertebral artery. As a decompression landmark in anterior cervical spine surgery, it not only ensures surgical safety but also guarantees complete decompression.
Humans
;
Adult
;
Male
;
Female
;
Middle Aged
;
Retrospective Studies
;
Cervical Vertebrae/surgery*
;
Magnetic Resonance Imaging
;
Decompression, Surgical/methods*
;
Young Adult
;
Adolescent
;
Computed Tomography Angiography
;
Imaging, Three-Dimensional
;
Vertebral Artery/anatomy & histology*
;
Anatomic Landmarks/diagnostic imaging*
10.A comparative study of color Doppler ultrasound and CT angiography for preoperative evaluation of perforator vessels in free posterior interosseous artery flap.
Hongquan WANG ; Shanshan LIU ; Yingzhi XIE ; Haoliang HU ; Miaozhong LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):483-487
OBJECTIVE:
To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps.
METHODS:
Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient's satisfaction with the appearance of the skin flap.
RESULTS:
The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods ( P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods ( P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture,with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9.
CONCLUSION
CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.
Humans
;
Female
;
Male
;
Adult
;
Perforator Flap/blood supply*
;
Middle Aged
;
Ultrasonography, Doppler, Color/methods*
;
Computed Tomography Angiography/methods*
;
Soft Tissue Injuries/diagnostic imaging*
;
Hand Injuries/diagnostic imaging*
;
Plastic Surgery Procedures/methods*
;
Hand/surgery*
;
Preoperative Care
;
Arteries/diagnostic imaging*


Result Analysis
Print
Save
E-mail