1.Preparation and in vitro property evaluation of β-cyclodextrin-daidzein/PEG_(20000)/Carbomer_(940) nanocrystals.
Yong-Mei GUAN ; Sheng-Hang YE ; Xiang ZHOU ; Zhen-Zhong ZANG ; Li-Hua CHEN ; Wei-Feng ZHU
China Journal of Chinese Materia Medica 2023;48(11):2949-2957
This study aims to improve the solubility and bioavailability of daidzein by preparing the β-cyclodextrin-daidzein/PEG_(20000)/Carbomer_(940) nanocrystals. Specifically, the nanocrystals were prepared with daidzein as a model drug, PEG_(20000), Carbomer_(940), and NaOH as a plasticizer, a gelling agent, and a crosslinking agent, respectively. A two-step method was employed to prepare the β-cyclodextrin-daidzein/PEG_(20000)/Carbomer_(940) nanocystals. First, the insoluble drug daidzein was embedded in β-cyclodextrin to form inclusion complexes, which were then encapsulated in the PEG_(20000)/Carbomer_(940) nanocrystals. The optimal mass fraction of NaOH was determined as 0.8% by the drug release rate, redispersability, SEM morphology, encapsulation rate, and drug loading. The inclusion status of daidzein nanocrystals was determined by Fourier transform infrared spectroscopy(FTIR), thermogravimetric analysis(TGA), and X-ray diffraction(XRD) analysis to verify the feasibility of the preparation. The prepared nanocrystals showed the average Zeta potential of(-30.77±0.15)mV and(-37.47±0.64)mV and the particle sizes of(333.60±3.81)nm and(544.60±7.66)nm before and after daidzein loading, respectively. The irregular distribution of nanocrystals before and after daidzein loading was observed under SEM. The redispersability experiment showed high dispersion efficiency of the nanocrystals. The in vitro dissolution rate of nanocrystals in intestinal fluid was significantly faster than that of daidzein, and followed the first-order drug release kinetic model. XRD, FTIR, and TGA were employed to determine the polycrystalline properties, drug loading, and thermal stability of the nanocrystals before and after drug loading. The nanocrystals loaded with daidzein demonstrated obvious antibacterial effect. The nanocrystals had more significant inhibitory effects on Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa than daidzein because of the improved solubility of daidzein. The prepared nanocrystals can significantly increase the dissolution rate and oral bioavailability of the insoluble drug daidzein.
Sodium Hydroxide
;
Acrylic Resins
;
Escherichia coli
;
Nanoparticles
2.Finite element analysis of PMMA bone cement reinforced screw plate fixation for osteoporotic proximal humeral fracture.
Wei-Bin WANG ; Xin-Hua YUAN ; Qing-Song FU ; Xin-You HAN
China Journal of Orthopaedics and Traumatology 2023;36(3):262-267
OBJECTIVE:
With the help of finite element analysis, to explore the effect of proximal humeral bone cement enhanced screw plate fixation on the stability of internal fixation of osteoporotic proximal humeral fracture.
METHODS:
The digital model of unstable proximal humeral fracture with metaphyseal bone defect was made, and the finite element models of proximal humeral fracture bone cement enhanced screw plate fixation and common screw plate fixation were established respectively. The stress of cancellous bone around the screw, the overall stiffness, the maximum stress of the plate and the maximum stress of the screw were analyzed.
RESULTS:
The maximum stresses of cancellous bone around 6 screws at the head of proximal humeral with bone cement enhanced screw plate fixation were 1.07 MPa for No.1 nail, 0.43 MPa for No.2 nail, 1.16 MPa for No.3 nail, 0.34 MPa for No.4 nail, 1.99 MPa for No.5 nail and 1.57 MPa for No.6 nail. These with common screw plate fixation were:2.68 MPa for No.1 nail, 0.67 MPa for No.2 nail, 4.37 MPa for No.3 nail, 0.75 MPa for No.4 nail, 3.30 MPa for No.5 nail and 2.47 MPa for No.6 nail. Overall stiffness of the two models is 448 N/mm for bone cement structure and 434 N/mm for common structure. The maximum stress of plate appears in the joint hole:701MPa for bone cement structure and 42 0MPa for common structure. The maximum stress of screws appeared at the tail end of No.4 nail:284 MPa for bone cement structure and 240.8 MPa for common structure.
CONCLUSION
Through finite element analysis, it is proved that the proximal humerus bone cement enhanced screw plate fixation of osteoporotic proximal humeral fracture can effectively reduce the stress of cancellous bone around the screw and enhance the initial stability after fracture operation, thus preventing from penetrating out and humeral head collapsing.
Humans
;
Finite Element Analysis
;
Bone Cements
;
Polymethyl Methacrylate
;
Biomechanical Phenomena
;
Shoulder Fractures/surgery*
;
Fracture Fixation, Internal
;
Humeral Head
;
Bone Screws
;
Bone Plates
3.Effect of acrylic bone cement mixed with calcium sulfate combined with percutaneous kyphoplasty in the treatment of osteoporotic fractures.
Yang FU ; Ying-Chao YAN ; Xuan-Liang RU ; Hang-Bo QU
China Journal of Orthopaedics and Traumatology 2023;36(9):896-900
OBJECTIVE:
To investigate the clinical efficacy of acrylic cement (PMMA) mixed with calcium sulfate combined with percutaneous kyphoplasty (PKP) in the treatment of osteoporotic fracture (OVCF).
METHODS:
The clinical data of 191 patients with OVCF treated with PKP from January 2020 to March 2021 were retrospectively analyzed. Among them, 82 patients with 94 vertebral bodies were treated with PMMA mixed with calcium sulfate as the observation group, and 109 patients with 125 vertebral bodies were treated with pure PMMA as the control group. Among the 82 patients in the observation group, there were 16 males and 66 females, with a mean age of (75.35±11.22) years old, including 36 thoracic vertebrae and 58 lumbar vertebrae. In the control group, there were 109 patients, 22 males and 87 females, with an average age of (74.51±9.21) years old, including 63 thoracic vertebrae and 62 lumbar vertebrae. The visual analog scale (VAS) before operation and 1 day, 3 months and 1 year after operation were calculated. The Oswestry disability index (ODI), Cobb's angle, vertebral body height and the probability of postoperative bone cement leakage were used to analyze the efficacy of the two groups.
RESULTS:
All the patients were followed up for more than one year. Compared with the control group, there was no significant difference in operation time, bleeding volume and bone cement injection volume between the two groups(P>0.05), while the leakage rate of bone cement was significantly lower in the observation group (P<0.05). In addition, there was no significant difference in VAS, ODI, Cobb angle, and vertebral body height between the two groups before operation, and 1 day, 3 months, and 1 year after operation (P>0.05), but each index was improved compared with that before operation (P<0.05).
CONCLUSION
PMMA mixed with calcium sulfate has equivalent efficacy in treating OVCF than PMMA alone, but can effectively reduce the probability of cement leakage.
Female
;
Male
;
Humans
;
Aged
;
Aged, 80 and over
;
Middle Aged
;
Polymethyl Methacrylate
;
Calcium Sulfate/therapeutic use*
;
Osteoporotic Fractures/surgery*
;
Bone Cements/therapeutic use*
;
Kyphoplasty
;
Retrospective Studies
;
Lumbar Vertebrae/surgery*
4.Application evaluation of prefabricated rigid connecting bar in implants immediate impression preparation of edentulous jaw.
Juan WANG ; Hua Jie YU ; Jing De SUN ; Li Xin QIU
Journal of Peking University(Health Sciences) 2022;54(1):187-192
OBJECTIVE:
To compare the operation complexity and accuracy of traditional splint impression technique and impression technique with prefabricated rigid connecting bar system for full-arch implants-supported fixed protheses in vitro.
METHODS:
Standard mandibular edentulous model with six implant analogs was prepared. The implants were placed at the bone level and multiunit abutments screwed into the implants. Two impression techniques were performed: the traditional splint impression technique was used in the control group, and the rigid connecting bar system was used in the test group. In the control group, impression copings were screwed into the multiunit abutments and connected with autopolymerizing acrylic resin. Open tray impression was fabricated with custom tray and polyether. In the test group, cylinders were screwed into the multiunit abutments. Prefabricated rigid bars with suitable length were selected and connected to the cylinders with small amount of autopolymerizing acrylic resin, and open tray impression was obtained. Impression procedures were repeated 6 times in each group. The working time of the two impression methods were recorded and compared. Analogs were screws into the impressions and gypsum casts were poured. The gypsum casts and the standard model were transferred to stereolithography (STL) files with model scanner. Comparative analysis of the STL files of the gypsum casts and the standard model was carried out and the root mean square (RMS) error value of the gypsum casts of the control and test groups compared with the standard model was recorded. The trueness of the two impression techniques was compared.
RESULTS:
The work time in the test group was significantly lower than that in the control group and the difference was statistically significant [(984.5±63.3) s vs. (1 478.3±156.2) s, P < 0.05]. Compared with the standard model, the RMS error value of the implant abutments in the test group was (16.9±5.5) μm. The RMS value in the control group was (20.2±8.0) μm. The difference between the two groups was not significant (P>0.05).
CONCLUSION
The prefabricated rigid connecting bar can save the chair-side work time in implants immediate loading of edentulous jaw and simplify the impression process. The impression accuracy is not significantly different from the traditional impression technology. The impression technique with prefabricated rigid connecting bar system is worthy of clinical application.
Acrylic Resins
;
Calcium Sulfate
;
Dental Implants
;
Dental Impression Materials
;
Dental Impression Technique
;
Humans
;
Jaw, Edentulous
;
Models, Dental
;
Mouth, Edentulous
5.Research progress on health hazards and occupational protection of prolymethylmethacrylate bone cement in the operating room.
Qiu Ping WU ; Xiao Qin GAN ; Hao Yu PEI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(5):396-400
There are many occupational risk factors in operating room work. Polymethyl methacrylate (PMMA) , as a kind of common bone filling and repairing material, is widely used in the fixation of artificial joints, oral braces and orthopedic prosthesis. However, PMMA will release methyl methacrylate (MMA) monomer when it is implanted into human tissues and polymerized to harden, which is toxic to the body. This paper analyzes harmful factors in using PMMA bone cement, and then explores corresponding occupational protection knowledge, in order to reduce the occurrence of occupational hazards related to PMMA bone cement and enhance the self-protection ability of the operation room medical staff.
Bone Cements/adverse effects*
;
Humans
;
Operating Rooms
;
Polymethyl Methacrylate/adverse effects*
6.Research progress on bone defect repair materials.
Guo-Ding CAO ; Yu-Qi PEI ; Jun LIU ; Peng LI ; Peng LIU ; Xu-Sheng LI
China Journal of Orthopaedics and Traumatology 2021;34(4):382-388
In the process of repairing of bone defects, bone scaffold materials need to be implanted to restore the corresponding tissue structure at the injury. At present, the repair materials used for bone defects mainly include autogenous bone, allogeneic bone, metal materials, bioceramics, polymer materials and various composite materials. Different materials have demonstrated strong reconstruction ability in bone repair, but the ideal bone implants in the clinic are still yet to be established. Except for autogenous bone, other materials used in bone defect repair are unable to perfectly balance biocompatibility, bone formation, bone conduction and osteoinduction. Combining the latest advances in materials sciences and clinical application, we believe that composite materials supplementedwith Chinese medicine, tissue cells, cytokines, trace elements, etc. and manufactured using advanced technologies such as additive manufacturing technology may have ideal bone repair performance, and may have profound significance in clinical repair of bone defects of special type. This article reviewed to the domestic and foreign literature in recent years, and elaborates the current status of bone defect repair materials in clinical application and basic research in regard to the advantages, clinical options, shortcomings, and how to improve the autogenous bone, allogeneic bone and artificial bone materials, in order to provide a theoretical basis for clinical management of bone defects.
Acrylic Resins
;
Biocompatible Materials
;
Bone Substitutes
;
Bone and Bones
;
Osteogenesis
;
Tissue Engineering
;
Tissue Scaffolds
7.Preliminary application of CPC/PMMA composite bone cement in kyphoplasty for the elderly.
Xuan-Geng DENG ; Xiao-Ming XIONG ; Wei CUI ; Tao GU ; Dun WAN ; Hua-Gang SHI ; Xing CHEN ; Si-Mao SONG ; Wei HOU ; Guo-Long MEI ; Wen-Bing JIANG
China Journal of Orthopaedics and Traumatology 2020;33(9):831-836
OBJECTIVE:
From the perspective of clinical application to analyze the effectiveness and reliability of CPC/PMMA bone cement in percutaneous kyphoplasty (PKP) for the treatment of elderly patients with osteoporotic thoracolumbar fractures.
METHODS:
A retrospective analysis was performed on 62 patients with osteoporotic compression fracture of single-vertebral thoracic or lumbar segment who underwent PKP surgery and had a bone density less than or equal to -3.0 SD from February 2016 to December 2016. Among them, 23 patients were in CPC/PMMA group, with an average age of (77.6±2.2) years old, 39 patients in PMMA group, with an average age of (77.1±1.1) years old. The indexes between two groups were compared, including the visual analogue scale (VAS), height ratio of anterior vertebra (AVHR), local Cobb angle, cement leakage, new adjacent vertebral fracture(NAVF).
RESULTS:
There were no significant difference in gender, age, follow-up time and preoperative VAS, AVHR, local Cobb angle between two groups (>0.05), at the 1 day after operation, VAS, AVHR, local Cobb angle in all patients got obvious improvement (<0.05), which was no significant difference at 1 day after operation and final follow-up (>0.05). At the same time, there was no statistically significant difference in the incidence of new adjacent vertebral fracture and cement leakage (>0.05). The pain in both groups continued to improve at follow up after operation (<0.05), the local Cobb angle increased (<0.05) and AVHR decreased slightly (<0.05). However, the images of conventional methods (X-ray or CT) could not find signs about CPC degeneration and new bone ingrowth.
CONCLUSION
CPC/PMMA composite bone cement is safe and reliablein PKP for treatment of elderly patients with osteoporotic thoracolumbar fractures, which can effectively relieve pain and maintain vertebral body stability. It has the same curative effect as PMMA bone cement. It was worthy to research more in future, although no direct evidences support the CPC/PMMA composite bone cement can reduce the incidence of adjacent vertebral fracture, CPC degeneration or new bone ingrowth.
Aged
;
Bone Cements
;
Dinucleoside Phosphates
;
Fractures, Compression
;
Humans
;
Kyphoplasty
;
Osteoporotic Fractures
;
Polymethyl Methacrylate
;
Reproducibility of Results
;
Retrospective Studies
;
Spinal Fractures
;
Treatment Outcome
;
Vertebroplasty
8.Progress of antibiotic-loaded bone cement in joint arthroplasty.
Yi-Ming XU ; Hui-Ming PENG ; Bin FENG ; Xi-Sheng WENG
Chinese Medical Journal 2020;133(20):2486-2494
Bone cement, consisting of polymethyl methacrylate, is a bioinert material used for prothesis fixation in joint arthroplasty. To treat orthopedic infections, such as periprosthetic joint infection, antibiotic-loaded bone cement (ALBC) was introduced into clinical practice. Recent studies have revealed the limitations of the antibacterial effect of ALBC. Moreover, with the increase in high infection risk patients and highly resistant microbes, more researches and modification of ALBC are required. This paper reviewed latest findings about ALBC for most popular and destructive pathogens, summarized the influence of antibiotic kind, drug dosage, application method, and environment towards characteristic of ALBC. Subsequently, new cement additives and clinical applications of ALBC in joint arthroplasty were also discussed.
Anti-Bacterial Agents/therapeutic use*
;
Arthroplasty, Replacement, Knee
;
Bone Cements
;
Humans
;
Polymethyl Methacrylate
;
Prosthesis-Related Infections/drug therapy*
9.Preparation of Cangai oil transfersomes patches and its in vitro evaluation.
Kun ZHANG ; Lei XIONG ; Dan-Ye LI ; Jia-Ju GAO ; Yun-Kuan LIU ; Yun-Shu MA
China Journal of Chinese Materia Medica 2020;45(4):854-860
L_9(3~4) orthogonal experiment design was used to optimize the preparation of the patches,and investigate its affecting factors and skin irritation. Eugenol was taken as the index component to study the release behavior in vitro and percutaneous penetration of Cangai oil transfersomes patches by HPLC.The results showed that the optimal prescription for preparing Cangai oil transfersomes patches were Eudragit E100 0.6 g, succinic acid 0.08 g,triethyl citrate 0.25 g,glycerol 0.2 g.Patches prepared by the preferred preparation had a flat appearance without obvious bubbles.The initial adhesion was 18.33±2.52, the stickiness was(30.01±2.45) min,and the peel strength was(5.62±0.95) kN·m~(-1).The results of affecting factors experiment showed the order of factors affecting its adhesion was humidity>temperature>lighting,and the skin irritation test results showed no significant skin irritation after 24 h of single administration. The results of drug release behavior in vitro showed that the release and the percutaneous penetration of both Cangai oil patches and Cangai oil transfersomes patches conformed to the Higuchi equation.The release amount of eugenol were 80.66% and 82.25% at 72 h, with no significant difference. The cumulative permeation area of eugenol per unit area reached(0.195 6±0.065 9),(0.131 0±0.045 5) mg·cm~(-2) at 72 h, with significant differences(P<0.05).The experiment results proved that the preparation process of Cangai oil transfersomes patches was stable,and the prepared patches had a good adhesion. At the same time,the preparation of transfersomes patches could alleviate and control the release of the drug to a certain extent, and provide a certain experimental basis for clinical pediatric drug safety.
Administration, Cutaneous
;
Drug Carriers
;
Drug Liberation
;
Humans
;
Plant Oils/pharmacology*
;
Polymethacrylic Acids
;
Skin/drug effects*
;
Skin Absorption
;
Transdermal Patch
10.Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations
The Journal of Advanced Prosthodontics 2019;11(2):95-104
PURPOSE: To evaluate the effect of surface treatments and repair materials on the shear bond strength and to measure the fracture toughness of CAD/CAM provisional restoration materials. MATERIALS AND METHODS: Four CAD/CAM (3D printing: Nextdent C&B and ZMD-1000B Temporary, CAD/CAM resin block: Yamahachi PMMA disk and Huge PMMA block) and four conventional (monometacrylate: Jet and Alike, dimetacrylate: Luxatemp and Protemp 4) materials were selected to fabricate disk-shaped specimens and divided into six groups according to surface treatment (n=10). CAD/CAM materials were repaired with Jet or Luxatemp, while conventional materials were repaired with their own materials. The shear bond strength was measured by using universal testing machine. Ten rectangular column-shaped specimens for each material were fabricated to measure the fracture toughness by single edge v notched beam technique. Statistical analysis was performed by one-way ANOVA. RESULTS: The highest shear bond strength of CAD/CAM materials was achieved by SiC paper + sandblasting. It was also accomplished when repairing 3D printing materials with Luxatemp, and repairing CAD/CAM resin blocks with Jet. Yamahachi PMMA disk showed the highest fracture toughness. Nextdent C&B showed the lowest fracture toughness value but no statistically significant difference from Alike and Luxatemp (P>.05). CONCLUSION: In order to successfully repair the CAD/CAM provisional restoration, mechanical surface treatment and appropriate repair material according to the CAD/CAM material type should be selected. The CAD/CAM provisional materials have proper mechanical properties for clinical use as compared to conventional materials.
Computer-Aided Design
;
Polymethyl Methacrylate
;
Printing, Three-Dimensional

Result Analysis
Print
Save
E-mail