1.Effects of ultrasonic rapid processing method on the protein, DNA, and RNA in paraffin-embedded tissues.
Xiaohong LI ; Jiadi LUO ; Qingchun LIANG ; Zhongyi TONG
Journal of Central South University(Medical Sciences) 2025;50(4):664-674
OBJECTIVES:
The traditional processing method for paraffin-embedded tissues is time-consuming, while the ultrasonic rapid processing method has a short processing time. However, its effects on tissue proteins, DNA, and RNA remain unclear. This study aims to evaluate the effects of the ultrasonic rapid processing method on proteins, DNA, and RNA in paraffin-embedded tissues through hematoxylin and eosin (HE) staining, immunohistochemical staining, and molecular pathological detection.
METHODS:
Surgical specimens from patients with breast cancer, colorectal cancer, lung cancer, signet-ring cell gastric cancer, liver cancer, and other tumors were selected. Two tissue blocks (1 to 3 mm in diameter) were obtained from each specimen (previously processed and diagnosed by routine pathology). One block was assigned to the control group (traditional processing method), and the other was the experimental group (ultrasonic rapid processing method). Via HE staining, immunohistochemical staining, DNA quality fragment analysis, fluorescent in situ hybrid for HER2 gene expression test, second-generation sequencing for EGFR and ALK gene mutation test, real-time reverse transcription PCR (real-time RT-PCR) for prognosis detection of breast cancer etc, the difference between 2 groups was compared, and further impact of the ultrasonic rapid processing method was analyzed.
RESULTS:
Compared with the control group, the ultrasound-assisted rapid method efficiently completed fixation, dehydration, clearing, and paraffin embedding, significantly reducing sample preparation time before pathological diagnosis. Results of HE staining, immunohistochemistry, DNA fragment analysis, fluorescence in situ hybridization for HER2 gene, next-generation sequencing for EGFR and ALK gene, and real-time RT-PCR for breast cancer prognosis were entirely consistent with those of the control group.
CONCLUSIONS
The ultrasonic rapid processing method can quickly and effectively shorten the time for specimen processing before pathological diagnosis, and will not affect the DNA, RNA and proteins of the specimens. It can meet the subsequent HE staining, immunohistochemistry and molecular pathological detection.
Humans
;
Paraffin Embedding/methods*
;
Female
;
RNA/analysis*
;
DNA/analysis*
;
Breast Neoplasms/pathology*
;
Neoplasms/genetics*
;
Ultrasonics/methods*
;
Proteins/analysis*
2.The influence of vowel and sound intensity on the results of voice acoustic formant detection was analyzed.
Bing XIE ; Zhe LI ; Hongxing WANG ; Xuyuan KUANG ; Wei NI ; Runqi ZHONG ; Yan LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2024;38(12):1149-1153
Objective:This study aims to explore the influence of vowels and sound intensity on formant, so as to provide reference for the selection of sound samples and vocal methods in acoustic detection. Methods:Thirty-eight healthy subjects, 19 male and 19 female, aged 19-24 years old were recruited. The formants of different vowels(/a/, //, /i/ and /u/) and different sound intensities(lowest sound, comfort sound, highest true sound and highest falsetto sound) were analyzed, and pairings were compared between groups with significant differences. Results:①The vowels /a/ and // in the first formant were larger than /i/ and /u/, and /i/ was the largest in the second formant. The minimum value of the first formant is the lowest sound of /i/ and the maximum is the highest sound of /a/. ②In the first formant, the chest sound area increases with the increase of sound intensity, while the second formant enters the highest falsetto and decreases significantly. Conclusion:Different vowels and sound intensity have different distribution of formant, that is, vowel and sound intensity have different degree of influence on formant. According to the extreme value of the first formant, the maximum normal range is determined initially, which is helpful to improve the acoustic detection.
Humans
;
Male
;
Female
;
Young Adult
;
Speech Acoustics
;
Voice Quality
;
Phonetics
;
Voice/physiology*
;
Adult
3.The effect of Wendler Glottoplasty to elevate vocal pitch in transgender women.
Chi ZHANG ; Qian HOU ; Ting Ting GUO ; Jing Ting ZHONG ; Hui REN ; Ge Lin LI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(2):139-144
Objective: To evaluate the effect of Wendler Glottoplasty to elevate vocal pitch in transgender women. Methods: The voice parameters of pre-and 3-month post-surgery of 29 transgender women who underwent Wendler Glottoplasty in department of otorhinolaryngology head and neck surgery of Beijing Friendship Hospital from January, 2017 to October, 2020 were retrospectively analyzed. The 29 transgender women ranged in age from 19-47 (27.0±6.3) years old. Subjective evaluation was performed using Transsexual Voice Questionnaire for Male to Female (TVQMtF). Objective parameters included fundamental frequency (F0), highest pitch, lowest pitch, habitual volume, Jitter, Shimmer, maximal phonation time (MPT), noise to harmonic ratio (NHR) and formants frequencies(F1, F2, F3, F4). SPSS 25.0 software was used for statistically analysis. Results: Three months after surgery, the score of TVQMtF was significantly decreased [(89.9±14.7) vs. (50.4±13.6), t=11.49, P<0.001]. The F0 was significantly elevated [(152.7±23.3) Hz vs. (207.7±45.9) Hz, t=-6.03, P<0.001]. Frequencies of F1, F2 and F3 were significantly elevated. No statistical difference was observed in the frequencies of F4. The highest pitch was not significantly altered while the lowest pitch was significantly elevated [(96.8±17.7) Hz vs. (120.0±28.9) Hz, t=-3.71, P=0.001]. Habitual speech volume was significantly increased [(60.0±5.2) dB vs. (63.6±9.6) dB, t=-2.12, P=0.043]. Jitter, Shimmer, NHR and MPT were not obviously altered (P>0.05). Conclusions: Wendler Glottoplasty could notably elevate the vocal pitch, formants frequencies and degree of vocal femininity in transgender women without affecting phonation ability and voice quality. It can be an effective treatment modality for voice feminization.
Humans
;
Male
;
Female
;
Young Adult
;
Adult
;
Middle Aged
;
Transgender Persons
;
Retrospective Studies
;
Speech Acoustics
;
Voice Quality
;
Phonation
5.Evaluation of an investigational hearing screening device (HeLe) to demonstrate acoustic brainstem response among normal-hearing adults
Philip B. Fullante ; Patrick John P. Labra ; Juan Miguel A. Mauricio ; Amadona R. Luistro ; Portia Grace F. Marcelo ; Luis G. Sison ; Charlotte M. Chiong
Acta Medica Philippina 2023;57(9):55-59
Objective:
This pilot human trial demonstrates the ability of the investigational newborn hearing screening device to provide acoustic stimulation to produce evoked potentials, as well as its ability to capture and acquire auditory evoked potentials, especially the auditory brainstem response (ABR) wave V. This pilot study also demonstrates the ease of recognizing and identifying ABR waves in the graphical presentation of the evoked potentials over time.
Methods:
Fourteen normal-hearing adults or a total of twenty-eight (28) normal-hearing adult ears underwent auditory brainstem response testing using the investigational hearing screening device. A commercially available auditory brainstem response detection device was used to confirm that the acquired ABR waves of the investigational device are normal. The ABR waves displayed by the investigation device were also reviewed by the clinical audiologists to determine their recognizability and identifiability.
Results:
The pilot trial demonstrates the ability of the investigational newborn hearing screening device in providing acoustic stimulation to produce evoked potentials, and in acquiring and capturing ABR waves, specifically the wave V, among normal-hearing adult ears. The clinical audiologists recognized and identified the ABR wave V among the evoked potentials at 40dB, 60dB, and 80dB acoustic stimulation. About eighty-nine percent (89.2%) of all ears tested had identifiable and recognizable wave V upon acoustic stimulation at 40dB.
Conclusion
The investigational hearing screening device: (1) can provide acoustic stimulation to produce evoked potentials, (2) can accurately capture and acquire these evoked potentials, (3) can present these evoked potentials in a voltage per time graphical display which an audiologist and trained HCP can easily read and interpret (diagnostic ABR), and (4) can present wave V auditory brainstem potentials that can be easily identified by an audiologist and trained HCP (screening ABR).
Infant, Newborn
;
Acoustics
;
Pilot Projects
6.The short-term outcomes of non-contact low frequency ultrasonic debridement in treating periprosthetic joint infections:a prospective single-arm clinical study.
Bao Chao JI ; Abudusaimi AIMAITI ; Fei WANG ; Jing Jie ZHENG ; Li CAO
Chinese Journal of Surgery 2023;61(2):129-137
Objective: To evaluate the short-term outcomes of non-contact low-frequency ultrasonic debridement in treating periprosthetic joint infections(PJI). Methods: The clinical data of patients with PJI who met the eligibility criteria and were treated with non-contact low-frequency ultrasonic debridement from August 2021 to January 2022 at the Department of Orthopaedics,the First Affiliated Hospital of Xinjiang Medical University were prospectively analyzed. PJI was defined according to the modified Musculoskeletal Infection Society criteria in 2016. After mechanical debridement,an 8-mm handheld non-contact low-frequency ultrasound probe was used for ultrasonic debridement in the whole surgical area at a frequency of (25±5)kHz and power of 90% for 5 minutes. Each ultrasound lasted 10 seconds with 3-second intervals. The probe was repeatedly sonicated among all soft tissue,bone interface and metal prosthesis surface(patients underwent debridement,antibiotics and implant retention (DAIR)) in the surgical area. The femoral canal of the hip joint,the distal femoral canal and the posterior capsule of the knee were fully sonicated with a special right-angle probe. Before and after ultrasonic debridement,20 ml of liquid was extracted from each operation area and injected into aerobic and anaerobic culture bottles,respectively,for pathogen culture. Harris hip score and Hospital for Special Surgery (HSS) score were used to evaluate clinical function. Treatment failure was defined as the recurrence of infection in the same joint. The patients were routinely followed up in the outpatient clinic at 1,3,and 6 months postoperatively and then annually with a deadline of August 2022. The paired t-test,rank sum,Mann-Whitney U or χ2 test was used to compare the observed data,and rates among multiple groups were compared using the Bonferroni approach. Results: A total of 45 patients were included in the study,including 21 men and 24 women with age of (65.8±15.2)years(range: 20 to 80 years) and body mass index of (29.3±4.2)kg/m2(range: 20.2 to 38.5 kg/m2). Twenty-eight patients (18 hips and 10 knees) underwent one-stage revision,and 17 cases (5 hips and 12 knees) underwent DAIR. Three of the patients (6.7%) had recurrent infections during follow-up. There were no intraoperative complications related to ultrasonic debridement (neurovascular and muscle injury,poor wound healing and fat liquefaction). Seventeen patients who received DAIR were followed for a median(M(IQR)) of 9(3) months,and two relapsed 3 weeks and 3 months post-operation,respectively. In addition,28 patients who underwent one-stage revision were followed for a median of 9(2) months,and one of the patients (3.6%,1/28) had a recurrence 6 months post-operation. The culture-positive rate of preoperative aspiration was 47.6% (20/42). The data of intraoperative soft tissue culture was 86.7% (39/45). The culture-positive rate of wound liquid before ultrasonic debridement was 46.7% (21/45). And the culture-positive rate after ultrasonic debridement was (75.6% (34/45)). After sonication,the culture-positive rate of explanted prostheses was 88.9% (40/45). There was a significant difference in culture-positive rates among all five cultures (χ2=35.483,P<0.01). Further pairwise comparison showed that the culture-positive rate of wound liquid after ultrasonic debridement was higher than that before ultrasonic debridement (χ2=7.901,P=0.005) but was not significantly different from the positive rates of other cultures (all P>0.05). The median number of colonies 24 hours after ultrasonic debridement(2 240 (1 310) CFU/ml,range: 310 to 3 140 CFU/ml) was significantly higher than that before debridement(450 (550) CFU/ml,range: 10 to 910 CFU/ml) (U=43, P=0.017). The post-operative Harris ((78.6±4.2)points,range:70.5 to 85.3 points) and HSS scores((76.4±4.8)points,range: 68.5 to 84.3 points) were significantly higher than the preoperative scores((46.0±9.8)points,range: 27.5 to 64.3 points;and (45.5±10.3)points,range: 27.6 to 63.1 points) (t=-14.6,t=-12.7;both P<0.01). Conclusions: Non-contact low-frequency ultrasonic debridement can increase the culture-positive rate and lead to a favorable short-term outcome. In addition,no complications are associated with using this new technique to treat PJI.
Female
;
Humans
;
Male
;
Anti-Bacterial Agents
;
Debridement
;
Knee Joint
;
Orthopedic Procedures
;
Prospective Studies
;
Ultrasonics
7.Analysis of wideband acoustic immittance measurements in patients with unilateral Ménière's disease.
Hui PAN ; Min XIE ; Bo LIU ; Hongjun XIAO
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(10):809-814
Objective:To investigate the characteristics of wideband acoustic immittance(WAI) measurements in patients with unilateral Ménière's disease(MD) and evaluate the clinical value of WAI in diagnosis of MD. Methods:WAI was performed in 30 patients with unilateral MD(30 ears for symptomatic and 30 ears for asymptomatic) and in 26 healthy individuals(52 ears)(control group). The WAI measurements, including the frequency first appearing two peaks in energy absorbance(EA) tympanogram, resonance frequency(RF), the peak value of absorbance(PVA), the integral area of absorbance(IAA), EA curve at peak pressure, were analyzed. Results:①The occurrence of two peaks in EA tympanogram in both the MD symptomatic and asymptomatic ear was observed in 27 ears(84.4%), and 38 ears(70.4%) in the control group, with no significant difference in the frequency of first appearing in two peaks onset between the groups(all P>0.05). ②The RF of the MD symptomatic ears was significantly lower than that of the asymptomatic ears(t=-3.544, P=0.001) and that of the control subjects(t=2.084, P=0.041); there was no difference of RF between the MD asymptomatic ears and the control group(P>0.05). ③The PVA were significantly lower in both MD symptomatic(t=4.240, P<0.01) and asymptomatic ears(t=4.202, P=0.001) than in controls. ④The IAA in MD symptomatic(t=3.295, P=0.001) and asymptomatic ears(t=3.193, P=0.003) was significantly lower than in the control group. ⑤Comparison of the EA curve at peak pressure of the three groups: the EAs of MD symptomatic ears were lower than those of the control group at the range of 1 059-2 911 Hz(all P<0.05); the EAs of MD symptomatic ears were lower than those of MD asymptomatic ears within 1 000 Hz and 1 834-2 119 Hz(all P<0.05); the EAs of MD asymptomatic ears were lower than those of the control group at the range of 515-2 748 Hz(all P<0.05). Conclusion:Symptomatic ears in unilateral MD patients show alterations in some WAI measurements compared to asymptomatic ears and/or controls, suggesting that middle ear mechanical fuction of the affected side may be modified due to the endolymphatic hydrops. The clinical significance of WAI needs to be further explored in the context of evaluating MD.
Humans
;
Meniere Disease/diagnosis*
;
Endolymphatic Hydrops/diagnosis*
;
Ear
;
Hearing Tests
;
Acoustics
8.Advances of ultrasonic neuromodulation based on mechanosensitive channels.
Bozhan WANG ; Xin LI ; Jiajia YANG ; Yutao TIAN
Chinese Journal of Biotechnology 2023;39(10):4029-4045
Mechanosensitive channels (MSCs) are special membrane proteins that can convert mechanical stimulation into electrical or chemical signals. These channels have become potential targets for ultrasonic neuromodulation due to their properties. The good spatial resolution and focusing effect of ultrasound make it theoretically possible to achieve non-invasive whole-brain localization. Therefore, ultrasonic neuromodulation is a promising method for performing physical neuromodulation and treating neurological disorders. To date, only a few ion channels have been reported to be activated by ultrasound, while recent research has identified more channels with mechanosensitive properties. Moreover, the opening process and mechanism of MSCs under ultrasound excitation remain unknown. This review provides an overview on recent research advances and applications in MSCs, including large conductance mechanosensitive channels, transient receptor potential channels, degenerated protein/epithelial sodium channels, two-pore potassium channels, and piezo channels. These findings will facilitate future studies and applications of ultrasonic neuromodulation.
Ultrasonics
;
Ion Channels/metabolism*
9.Research on magneto-acoustic-electrical tomography method based on liquid metal contrast agent and M sequence coded excitation.
Yuheng WANG ; Junjie LIN ; Wenshu MAI ; Zhipeng LIU ; Tao YIN ; Shunqi ZHANG
Journal of Biomedical Engineering 2023;40(4):718-724
Magneto-acoustic-electric tomography (MAET) boasts high resolution in ultrasound imaging and high contrast in electrical impedance imaging, making it of significant research value in the fields of early tumor diagnosis and bioelectrical monitoring. In this study, a method was proposed that combined high conductivity liquid metal and maximum length sequence (M sequence) coded excitation to improve the signal-to-noise ratio. It was shown that, under rotational scanning, the liquid metal significantly improved the signal-to-noise ratio of the inter-tissue magneto-acoustic-electric signal and enhanced the quality of the reconstructed image. The signal-to-noise ratio of the signal was increased by 5.6, 11.1, 21.7, and 45.7 times under the excitation of 7-, 15-, 31-, and 63-bit M sequence code, respectively. The total usage time of 31-bit M sequence coded excitation imaging was shortened by 75.6% compared with single-pulse excitation when the same signal-to-noise ratio was improved. In conclusion, the imaging method combining liquid metal and M-sequence coding excitation has positive significance for improving MAET image quality.
Contrast Media
;
Electricity
;
Electric Conductivity
;
Acoustics
;
Tomography
10.Study on application of ultrasonic bone curette in anterior cervical spine surgery.
Chen XU ; Zhaodong WANG ; Yajun LIU ; Zhonglian ZHU ; Keyou DUAN ; Min WU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):996-1001
OBJECTIVE:
To investigate the effect of ultrasonic bone curette in anterior cervical spine surgery.
METHODS:
A clinical data of 63 patients with cervical spondylosis who were admitted between September 2019 and June 2021 and met the selection criteria was retrospectively analyzed. Among them, 32 cases were operated with conventional instruments (group A) and 31 cases with ultrasonic bone curette (group B). There was no significant difference between the two groups (P>0.05) in gender, age, surgical procedure, surgical segment and number of occupied cervical space, disease type and duration, comorbidities, and preoperative Japanese Orthopaedic Association (JOA) score, cervical dysfunction index (NDI), and pain visual analogue scale (VAS) score. The operation time, intraoperative bleeding, postoperative drainage, postoperative hospital stay, and the occurrence of postoperative complications were recorded in both groups. Before operation and at 1, 3, and 6 months after operation, the JOA score and NDI were used to evaluate the function and the postoperative JOA improvement rate was calculated, and VAS score was used to evaluate the pain improvement. The anteroposterior and lateral cervical X-ray films were taken at 1, 3, and 6 months after operation to observe whether there was any significant loosening and displacement of internal fixators.
RESULTS:
Compared with group A, group B had shorter operation time and postoperative hospital stay, less intraoperative bleeding and postoperative drainage, and the differences were significant (P<0.05). All incisions healed by first intention in the two groups, and postoperative complications occurred in 5 cases (15.6%) in group A and 2 cases (6.5%) in group B, showing no significant difference (P>0.05). All patients were followed up 6-12 months (mean, 7.9 months). The JOA score and improvement rate gradually increased in groups A and B after operation, while the VAS score and NDI gradually decreased. There was no significant difference in VAS score between 3 months and 1 month in group B (P>0.05), and there were significant differences between the other time points of each indicator in the two groups (P<0.05). At 1, 3, and 6 months after operation, the JOA score and improvement rate in group B were better than those in group A (P<0.05). X-ray films examination showed that there was no screw loosening or titanium plate displacement in the two groups after operation, and the intervertebral cage or titanium mesh significantly sank.
CONCLUSION
Compared with traditional instruments, the use of ultrasonic bone curette assisted osteotomy in anterior cervical spine surgery has the advantages of shorter operation time, less intraoperative bleeding, less postoperative drainage, and shorter hospital stay.
Humans
;
Ultrasonics
;
Retrospective Studies
;
Titanium
;
Postoperative Complications/epidemiology*
;
Bone Plates
;
Cervical Vertebrae/surgery*


Result Analysis
Print
Save
E-mail