1.Anatomical research of positional relationship between protective channel and sural nerve during Achilles tendon repair using channel assisted minimally invasive repair technique.
Zhonghe WANG ; Wenhao CAO ; Hongzhe QI ; Lingtong KONG ; Haoyu LIU ; Chen CHEN ; Lianhua LI ; Lijun SUN ; Hua CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(11):1325-1329
OBJECTIVE:
To evaluate the positional relationship between protective channel and sural nerve while treating acute Achilles tendon rupture with channel assisted minimally invasive repair (CAMIR) technique based on anatomical observations of cadaver specimens.
METHODS:
Twelve adult cadaveric lower limb specimens (6 left, 6 right) were utilized. A CAMIR device was implanted at a distance of 4 cm from the proximal end of the specimen to the Achilles tendon insertion. The skin was incised along the tendon's medial side, the sural nerve was dissected, and the positional relationship with the protective channel was observed. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion, the vertical distance between protective channel and the calcaneal insertion, and the horizontal distance between the sural nerve and protective channel were measured by using vernier caliper.
RESULTS:
Anatomical examination demonstrated a variable positional relationship between the sural nerve and protective channel, with the sural nerve positioned above (8 specimens) or below (4 specimens) the protective channel. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion was (105.67±14.94) mm, the vertical distance between protective channel and the calcaneal insertion was (93.20±9.57) mm, and the horizontal distance between the sural nerve and protective channel was (0.31±0.14) mm.
CONCLUSION
The use of CAMIR technique for the treatment of acute Achilles tendon rupture can effectively avoid iatrogenic injury to the sural nerve.
Humans
;
Achilles Tendon/injuries*
;
Sural Nerve/anatomy & histology*
;
Cadaver
;
Minimally Invasive Surgical Procedures/methods*
;
Tendon Injuries/surgery*
;
Rupture/surgery*
;
Adult
;
Male
;
Calcaneus/injuries*
;
Female
;
Plastic Surgery Procedures/methods*
2.Qualitative and Quantitative Assessment of Isotropic Ankle Magnetic Resonance Imaging: Three-Dimensional Isotropic Intermediate-Weighted Turbo Spin Echo versus Three-Dimensional Isotropic Fast Field Echo Sequences.
Hyun Su KIM ; Young Cheol YOON ; Jong Won KWON ; Bong Keun CHOE
Korean Journal of Radiology 2012;13(4):443-449
OBJECTIVE: To compare the image quality of volume isotropic turbo spin echo acquisition (VISTA) imaging method with that of the three-dimensional (3D) isotropic fast field echo (FFE) imaging method applied for ankle joint imaging. MATERIALS AND METHODS: MR imaging of the ankles of 10 healthy volunteers was performed with VISTA and 3D FFE sequences by using a 3.0 T machine. Two radiologists retrospectively assessed the tissue contrast between fluid and cartilage (F-C), and fluid and the Achilles tendon (F-T) with use of a 4-point scale. For a quantitative analysis, signal-to-noise ratio (SNR) was obtained by imaging phantom, and the contrast ratios (CRs) were calculated between F-T and F-C. Statistical analyses for differences in grades of tissue contrast and CRs were performed. RESULTS: VISTA had significantly superior grades in tissue contrast of F-T (p = 0.001). Results of 3D FFE had superior grades in tissue contrast of F-C, but these result were not statistically significant (p = 0.157). VISTA had significantly superior CRs in F-T (p = 0.002), and 3D FFE had superior CRs in F-C (p = 0.003). The SNR of VISTA was higher than that of 3D FFE (49.24 vs. 15.94). CONCLUSION: VISTA demonstrates superior tissue contrast between fluid and the Achiles tendon in terms of quantitative and qualitative analysis, while 3D FFE shows superior tissue contrast between fluid and cartilage in terms of quantitative analysis.
Achilles Tendon/*anatomy & histology
;
Adult
;
Ankle Joint/*anatomy & histology
;
Female
;
Humans
;
Image Processing, Computer-Assisted
;
Imaging, Three-Dimensional/methods
;
Magnetic Resonance Imaging/*methods
;
Male
;
Phantoms, Imaging
;
Retrospective Studies
;
Statistics, Nonparametric

Result Analysis
Print
Save
E-mail