1.Design and Research of Wearable Fall Protection Device for the Elderly.
Jie WANG ; Yeke SUN ; Zhenglong CHEN ; Yongchun JIN ; Yunhua XU
Chinese Journal of Medical Instrumentation 2023;47(3):278-283
A protective device was designed that can be worn on the elderly, which consists of protective airbag, control box and protective mechanism. The combined acceleration, combined angular velocity and human posture angle are selected as the parameters to determine the fall, and the threshold algorithm and SVM algorithm are used to detect the fall. The protective mechanism is an inflatable device based on CO2 compressed air cylinder, and the equal-width cam structure is applied to its transmission part to improve the puncture efficiency of the compressed gas cylinder. A fall experiment was designed to obtain the combined acceleration and angular velocity eigenvalues of fall actions (forward fall, backward fall and lateral fall) and daily activities (sitting-standing, walking, jogging and walking up and down stairs), showing that the specificity and sensitivity of the protection module reached 92.1% and 84.4% respectively, which verified the feasibility of the fall protection device.
Humans
;
Aged
;
Monitoring, Ambulatory
;
Activities of Daily Living
;
Wearable Electronic Devices
;
Walking
;
Acceleration
;
Algorithms
2.Application of generative adversarial network in magnetic resonance image reconstruction.
Xin CAI ; Xuewen HOU ; Guang YANG ; Shengdong NIE
Journal of Biomedical Engineering 2023;40(3):582-588
Magnetic resonance imaging (MRI) is an important medical imaging method, whose major limitation is its long scan time due to the imaging mechanism, increasing patients' cost and waiting time for the examination. Currently, parallel imaging (PI) and compress sensing (CS) together with other reconstruction technologies have been proposed to accelerate image acquisition. However, the image quality of PI and CS depends on the image reconstruction algorithms, which is far from satisfying in respect to both the image quality and the reconstruction speed. In recent years, image reconstruction based on generative adversarial network (GAN) has become a research hotspot in the field of magnetic resonance imaging because of its excellent performance. In this review, we summarized the recent development of application of GAN in MRI reconstruction in both single- and multi-modality acceleration, hoping to provide a useful reference for interested researchers. In addition, we analyzed the characteristics and limitations of existing technologies and forecasted some development trends in this field.
Humans
;
Acceleration
;
Algorithms
;
Magnetic Resonance Imaging
;
Technology
3.Peripheral blood immune cell-based biomarkers in anti-PD-1/PD-L1 therapy
Kyung Hwan KIM ; Chang Gon KIM ; Eui Cheol SHIN
Immune Network 2020;20(1):8-
Immune checkpoint blockade targeting PD-1 and PD-L1 has resulted in unprecedented clinical benefit for cancer patients. Anti-PD-1/PD-L1 therapy has become the standard treatment for diverse cancer types as monotherapy or in combination with other anti-cancer therapies, and its indications are expanding. However, many patients do not benefit from anti-PD-1/PD-L1 therapy due to primary and/or acquired resistance, which is a major obstacle to broadening the clinical applicability of anti-PD-1/PD-L1 therapy. In addition, hyperprogressive disease, an acceleration of tumor growth following anti-PD-1/PD-L1 therapy, has been proposed as a new response pattern associated with deleterious prognosis. Anti-PD-1/PD-L1 therapy can also cause a unique pattern of adverse events termed immune-related adverse events, sometimes leading to treatment discontinuation and fatal outcomes. Investigations have been carried out to predict and monitor treatment outcomes using peripheral blood as an alternative to tissue biopsy. This review summarizes recent studies utilizing peripheral blood immune cells to predict various outcomes in cancer patients treated with anti-PD-1/PD-L1 therapy.
Acceleration
;
Antigens, CD274
;
Biomarkers
;
Biopsy
;
Drug-Related Side Effects and Adverse Reactions
;
Fatal Outcome
;
Humans
;
Prognosis
;
Programmed Cell Death 1 Receptor
4.Feasibility of Simultaneous Multislice Acceleration Technique in Diffusion-Weighted Magnetic Resonance Imaging of the Rectum
Jae Hyon PARK ; Nieun SEO ; Joon Seok LIM ; Jongmoon HAHM ; Myeong Jin KIM
Korean Journal of Radiology 2020;21(1):77-87
acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) using a 3T scanner. Acquisition times of the three DWI sequences were measured. Image quality in the three DWI sequences was reviewed by two independent radiologists using a 4-point Likert scale and subsequently compared using the Friedman test. Apparent diffusion coefficient (ADC) values for rectal cancer and the normal rectal wall were compared among the three sequences using repeated measures analysis of variance.RESULTS: Acquisition times using C-DWI, SMS2-DWI, and SMS3-DWI were 173 seconds, 107 seconds, (38.2% shorter than C-DWI), and 77 seconds (55.5% shorter than C-DWI), respectively. For all image quality parameters other than distortion (margin sharpness, artifact, lesion conspicuity, and overall image quality), C-DWI and SMS2-DWI yielded better results than did SMS3-DWI (Ps < 0.001), with no significant differences observed between C-DWI and SMS2-DWI (Ps ≥ 0.054). ADC values of rectal cancer (p = 0.943) and normal rectal wall (p = 0.360) were not significantly different among C-DWI, SMS2-DWI, and SMS3-DWI.CONCLUSION: SMS-DWI using an acceleration factor of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of C-DWI.]]>
Acceleration
;
Artifacts
;
Diffusion
;
Humans
;
Magnetic Resonance Imaging
;
Rectal Neoplasms
;
Rectum
5.Comfort optimization of a new type of foot mechanism for lower extremity exoskeleton.
Yipeng LUAN ; Jianjun ZHANG ; Kaicheng QI ; Gaowei YANG
Journal of Biomedical Engineering 2020;37(2):324-333
In order to reduce the impact caused by the contact between the foot and the ground when wearing the lower extremity exoskeleton under the condition of high load, this paper proposed an exoskeleton foot mechanism for improving the foot comfort, and optimized the key index of its influence on the comfort. Firstly, the physical model of foot mechanism was established based on the characteristics of foot stress in gait period, and then the mathematical model of vibration was abstracted. The correctness of the model was verified by the finite element analysis software ANSYS. Then, this paper analyzed the influence of vibration parameters on absolute transmissibility based on vibration mathematical model, and optimized vibration parameters with MATLAB genetic algorithm toolbox. Finally, this paper took white noise to simulate the road elevation as the vibration input, and used the visual simulation tool Simulink in MATLAB and the vibration equation to construct the acceleration simulation model, and then calculated the vibration weighted root mean square acceleration value of the foot. The results of this study show that this foot comfort mechanism can meet the comfort indexes of vibration absorption and plantar pressure, and this paper provides a relatively complete method for the design of exoskeleton foot mechanism, which has reference significance for the design of other exoskeleton foot and ankle joint rehabilitation mechanism.
Acceleration
;
Ankle Joint
;
Biomechanical Phenomena
;
Exoskeleton Device
;
Finite Element Analysis
;
Foot
;
Gait
;
Humans
;
Lower Extremity
;
Models, Theoretical
;
Vibration
6.A Wearable System for Cervical Spondylosis Prevention Based on Artificial Intelligence.
Siyu LI ; Ping ZHOU ; Wenjin XIAO ; Guangquan ZHOU
Chinese Journal of Medical Instrumentation 2020;44(1):33-37
Accompanied by changes in modern work and lifestyle, the incidence of cervical spondylosis has increased year by year. In view of the fact long-term fixed posture of the head and neck is one of the main causes of cervical spondylosis, a set of wearable cervical spondylosis prevention system is developed. The system comprises a head and neck movement collection module based on the acceleration sensor and a head and neck motion recognition module based on artificial intelligence. Experimental results showed that the system can accurately identify long-term posture of the head and neck, and guide users to complete effective exercise therapy under the supervision of motion recognition module. Using this system can be beneficial for the prevention of cervical spondylosis.
Acceleration
;
Artificial Intelligence
;
Cervical Vertebrae
;
Exercise Therapy/instrumentation*
;
Humans
;
Movement
;
Neck
;
Posture
;
Spondylosis/prevention & control*
;
Treatment Outcome
;
Wearable Electronic Devices
7.Real-Time Computed Tomography Volume Visualization with Ambient Occlusion of Hand-Drawn Transfer Function Using Local Vicinity Statistic
Jaewoo KIM ; Taejun HA ; Heewon KYE
Healthcare Informatics Research 2019;25(4):297-304
OBJECTIVES: In this paper, we present an efficient method to visualize computed tomography (CT) datasets using ambient occlusion, which is a global illumination technique that adds depth cues to the output image. We can change the transfer function (TF) for volume rendering and generate output images in real time. METHODS: In preprocessing, the mean and standard deviation of each local vicinity are calculated. During rendering, the ambient light intensity is calculated. The calculation is accelerated on the assumption that the CT value of the local vicinity of each point follows the normal distribution. We approximate complex TF forms with a smaller number of connected line segments to achieve additional acceleration. Ambient occlusion is combined with the existing local illumination technique to produce images with depth in real time. RESULTS: We tested the proposed method on various CT datasets using hand-drawn TFs. The proposed method enabled real-time rendering that was approximately 40 times faster than the previous method. As a result of comparing the output image quality with that of the conventional method, the average signal-to-noise ratio was approximately 40 dB, and the image quality did not significantly deteriorate. CONCLUSIONS: When rendering CT images with various TFs, the proposed method generated depth-sensing images in real time.
Acceleration
;
Computer Systems
;
Cues
;
Dataset
;
Lighting
;
Mathematical Computing
;
Methods
;
Signal-To-Noise Ratio
8.Implication of Porphyromonas gingivalis in colitis and homeostasis of intestinal epithelium
Yoojin SEO ; Su Jeong OH ; Ji Su AHN ; Ye Young SHIN ; Ji Won YANG ; Hyung Sik KIM
Laboratory Animal Research 2019;35(4):187-193
Emerging evidences have reported that periodontitis can be a risk factor for the pathogenesis of various systemic diseases. Porphyromonas gingivalis (Pg), one of the crucial pathogens in chronic periodontitis, has been spotlighted as a potential cause for the promotion and acceleration of periodontitis-associated systemic disorders. To investigate the association between Pg and intestinal disease or homeostasis, we treated Pg-derived lipopolysaccharide (LPS) in murine colitis model or intestinal organoid, respectively. Pg-derived LPS (Pg LPS) was administrated into chemically induced murine colitis model and disease symptoms were monitored compared with the infusion of LPS derived from E. coli (Ec LPS). Organoids isolated and cultured from mouse small intestine were treated with Pg or Ec LPS and further analyzed for the generation and composition of organoids. In vivo observations demonstrated that both Pg and Ec LPS exerted slight protective effects against murine colitis. Pg LPS did not affect the generation and growth of intestinal epithelial organoids. Among subtypes of epithelial cells, markers for stem cells, goblet cells or Paneth cells were changed in response to Pg LPS. Taken together, these results indicate that Pg LPS leads to partial improvement in colitis and that its treatment does not significantly affect the self-organization of intestinal organoids but may regulate the epithelial composition.
Acceleration
;
Animals
;
Chronic Periodontitis
;
Colitis
;
Epithelial Cells
;
Goblet Cells
;
Homeostasis
;
Intestinal Diseases
;
Intestinal Mucosa
;
Intestine, Small
;
Mice
;
Organoids
;
Paneth Cells
;
Periodontitis
;
Porphyromonas gingivalis
;
Porphyromonas
;
Risk Factors
;
Stem Cells
9.Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
Hehan TANG ; Na HU ; Yuan YUAN ; Chunchao XIA ; Xiumin LIU ; Panli ZUO ; Aurelien F STALDER ; Michaela SCHMIDT ; Xiaoyue ZHOU ; Bin SONG ; Jiayu SUN
Korean Journal of Radiology 2019;20(2):265-274
OBJECTIVE: To compare the image quality of three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) with sparse undersampling and iterative reconstruction (sparse TOF) with that of conventional TOF MRA. MATERIALS AND METHODS: This study included 56 patients who had undergone sparse TOF MRA for intracranial artery evaluation on a 3T MR scanner. Conventional TOF MRA scans were also acquired from 29 patients with matched acquisition times and another 27 patients with matched scanning parameters. The image quality was scored using a five-point scale based on the delineation of arterial vessel segments, artifacts, overall vessel visualization, and overall image quality by two radiologists independently, and the data were analyzed using the non-parametric Wilcoxon signed-rank test. Contrast ratios (CRs) of vessels were compared using the paired t test. Interobserver agreement was calculated using the kappa test. RESULTS: Compared with conventional TOF at the same spatial resolution, sparse TOF with an acceleration factor of 3.5 could reduce acquisition time by 40% and showed comparable image quality. In addition, when compared with conventional TOF with the same acquisition time, sparse TOF with an acceleration factor of 5 could also achieve higher spatial resolution, better delineation of vessel segments, fewer artifacts, higher image quality, and a higher CR (p < 0.05). Good-to-excellent interobserver agreement (κ: 0.65–1.00) was obtained between the two radiologists. CONCLUSION: Compared with conventional TOF, sparse TOF can achieve equivalent image quality in a reduced duration. Furthermore, using the same acquisition time, sparse TOF could improve the delineation of vessels and decrease image artifacts.
Acceleration
;
Arteries
;
Artifacts
;
Humans
;
Magnetic Resonance Angiography
10.High-Resolution Magnetic Resonance Imaging Using Compressed Sensing for Intracranial and Extracranial Arteries: Comparison with Conventional Parallel Imaging
Chong Hyun SUH ; Seung Chai JUNG ; Ho Beom LEE ; Se Jin CHO
Korean Journal of Radiology 2019;20(3):487-497
OBJECTIVE: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries. MATERIALS AND METHODS: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF(t))-5.5, 6.8, and 9.7 for T1WI and 3.2, 4.0, and 5.8 for PD-to achieve reduced scanning times in comparison with the original imaging sequence (SENSE T1WI, AF(t) 3.5; SENSE PD, AF(t) 2.0) using the 3-tesla system. Two neuroradiologists measured signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and used visual scoring systems to assess image quality. Acceptable imaging was defined as a visual score ≥ 2. Repeated measures analysis of variance and Cochran's Q test were performed. RESULTS: CS yielded better image quality and vessel delineation than SENSE in T1WI with AF(t) of 5.5, 6.8, and 9.7, and in PD with AF(t) of 5.8 (p < 0.05). CS T1WI with AF(t) of 5.5 and CS PD with AF(t) of 3.2 and 4.0 did not differ significantly from original imaging (p > 0.05). SNR and CNR in CS were higher than they were in SENSE, but lower than they were in the original images (p < 0.05). CS yielded higher proportions of acceptable imaging than SENSE (CS T1WI with AF(t) of 6.8 and PD with AF(t) of 5.8; p < 0.0167). CONCLUSION: CS is superior to SENSE, and may be a reliable acceleration method for vessel HR-MRI using AF(t) of 5.5 for T1WI, and 3.2 and 4.0 for PD.
Acceleration
;
Arteries
;
Healthy Volunteers
;
Magnetic Resonance Imaging
;
Methods
;
Protons
;
Signal-To-Noise Ratio

Result Analysis