1.Influence of self-efficacy in health management and resilience on treatment compliance in Korean patients undergoing percutaneous coronary intervention: a descriptive survey study
Mi-Ra JUNG ; Eun JEONG ; Kyung Sim LEE ; Jang Hyun CHO
Journal of Korean Biological Nursing Science 2025;27(2):266-274
This study aimed to identify factors influencing treatment compliance in Korean patients undergoing percutaneous coronary intervention. Methods: The study included 130 patients who underwent percutaneous coronary intervention at St. Carollo Hospital. Data were collected using self-administered questionnaires from March 21, 2022 to May 30, 2023, and analyzed using descriptive statistics, the t-test, analysis of variance, the Scheffé test, Pearson correlation coefficients, and multiple regression in SPSS version 26.0. Results: Resilience (β = .59, p < .001), alcohol drinking (β = −.18, p = .005), and the diagnosis (β = .13, p = .040) accounted for 45.0% of the variance in treatment compliance in patients undergoing percutaneous coronary intervention. Conclusion: These results indicate that it is necessary to explore strategies for developing and implementing programs that can effectively enhance resilience in patients who have undergone percutaneous coronary intervention.
2.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
3.Neutralizing Activity and T-Cell Responses Against Wild Type SARSCoV-2 Virus and Omicron BA.5 Variant After Ancestral SARS-CoV-2 Vaccine Booster Dose in PLWH Receiving ART Based on CD4 T-Cell Count
Na Young HA ; Ah-Ra KIM ; Hyeongseok JEONG ; Shinhye CHEON ; Cho Rong PARK ; Jin Ho CHOE ; Hyo Jung KIM ; Jae Won YOON ; Miryoung KIM ; Mi Yeong AN ; Sukyoung JUNG ; Hyeon Nam DO ; Junewoo LEE ; Yeon-Sook KIM
Journal of Korean Medical Science 2025;40(9):e28-
Background:
We evaluated severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2)-specific humoral and cellular responses for up to 6 months after the 3rd dose of ancestral coronavirus disease 2019 (COVID-19) vaccination in people living with HIV (PLWH) and healthy controls (HCs) who were not infected with COVID-19.
Methods:
Anti-spike receptor-binding domain IgG (anti-RBD IgG) concentrations using chemiluminescence immunoassay and neutralizing antibodies using focus reduction neutralization test (FRNT) were assessed at 1 week after each dose of vaccination, and 3 and 6 months after the 3rd dose in 62 PLWH and 25 HCs. T-cell responses using intracellular cytokine stain were evaluated at 1 week before, and 1 week and 6 months after the 3rd dose.
Results:
At 1 week after the 3rd dose, adequate anti-RBD IgG (> 300 binding antibody unit /mL) was elicited in all PLWH except for one patient with 36 CD4 T-cell count/mm3 . The geometric mean titers of 50% FRNT against wild type (WT) and omicron BA.5 strains of SARS-CoV-2 in PLWH with CD4 T-cell count ≥ 500 cells/mm3(high CD4 recovery, HCDR) were comparable to HC, but they were significantly decreased in PLWH with CD4 T-cell count < 500/mm3 (low CD4 recovery, LCDR). After adjusting for age, gender, viral suppression, and number of preexisting comorbidities, CD4 T-cell counts < 500/mm3 significantly predicted a poor magnitude of neutralizing antibodies against WT, omicron BA.5, and XBB 1.5 strains among PLWH. Multivariable linear regression adjusting for age and gender revealed that LCDR was associated with reduced neutralizing activity (P = 0.017) and interferon-γ-producing T-cell responses (P = 0.049 for CD T-cell; P = 0.014 for CD8 T-cell) against WT, and strongly associated with more decreased cross-neutralization against omicron BA.5 strains (P < 0.001).
Conclusion
HCDR demonstrated robust humoral and cell-mediated immune responses after a booster dose of ancestral SARS-CoV-2 vaccine, whereas LCDR showed diminished immune responses against WT virus and more impaired cross-neutralization against omicron BA.5 strain.
4.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
5.Erratum to "Investigating the Immune-Stimulating Potential of β-Glucan from Aureobasidium pullulans in Cancer Immunotherapy" Biomol Ther 32(5), 556-567 (2024)
Jae-Hyeon JEONG ; Dae-Joon KIM ; Seong-Jin HONG ; Jae-Hee AHN ; Dong-Ju LEE ; Ah-Ra JANG ; Sungyun KIM ; Hyun-Jong CHO ; Jae-Young LEE ; Jong-Hwan PARK ; Young-Min KIM ; Hyun-Jeong KO
Biomolecules & Therapeutics 2025;33(1):233-233
6.Influence of self-efficacy in health management and resilience on treatment compliance in Korean patients undergoing percutaneous coronary intervention: a descriptive survey study
Mi-Ra JUNG ; Eun JEONG ; Kyung Sim LEE ; Jang Hyun CHO
Journal of Korean Biological Nursing Science 2025;27(2):266-274
This study aimed to identify factors influencing treatment compliance in Korean patients undergoing percutaneous coronary intervention. Methods: The study included 130 patients who underwent percutaneous coronary intervention at St. Carollo Hospital. Data were collected using self-administered questionnaires from March 21, 2022 to May 30, 2023, and analyzed using descriptive statistics, the t-test, analysis of variance, the Scheffé test, Pearson correlation coefficients, and multiple regression in SPSS version 26.0. Results: Resilience (β = .59, p < .001), alcohol drinking (β = −.18, p = .005), and the diagnosis (β = .13, p = .040) accounted for 45.0% of the variance in treatment compliance in patients undergoing percutaneous coronary intervention. Conclusion: These results indicate that it is necessary to explore strategies for developing and implementing programs that can effectively enhance resilience in patients who have undergone percutaneous coronary intervention.
7.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
8.Neutralizing Activity and T-Cell Responses Against Wild Type SARSCoV-2 Virus and Omicron BA.5 Variant After Ancestral SARS-CoV-2 Vaccine Booster Dose in PLWH Receiving ART Based on CD4 T-Cell Count
Na Young HA ; Ah-Ra KIM ; Hyeongseok JEONG ; Shinhye CHEON ; Cho Rong PARK ; Jin Ho CHOE ; Hyo Jung KIM ; Jae Won YOON ; Miryoung KIM ; Mi Yeong AN ; Sukyoung JUNG ; Hyeon Nam DO ; Junewoo LEE ; Yeon-Sook KIM
Journal of Korean Medical Science 2025;40(9):e28-
Background:
We evaluated severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2)-specific humoral and cellular responses for up to 6 months after the 3rd dose of ancestral coronavirus disease 2019 (COVID-19) vaccination in people living with HIV (PLWH) and healthy controls (HCs) who were not infected with COVID-19.
Methods:
Anti-spike receptor-binding domain IgG (anti-RBD IgG) concentrations using chemiluminescence immunoassay and neutralizing antibodies using focus reduction neutralization test (FRNT) were assessed at 1 week after each dose of vaccination, and 3 and 6 months after the 3rd dose in 62 PLWH and 25 HCs. T-cell responses using intracellular cytokine stain were evaluated at 1 week before, and 1 week and 6 months after the 3rd dose.
Results:
At 1 week after the 3rd dose, adequate anti-RBD IgG (> 300 binding antibody unit /mL) was elicited in all PLWH except for one patient with 36 CD4 T-cell count/mm3 . The geometric mean titers of 50% FRNT against wild type (WT) and omicron BA.5 strains of SARS-CoV-2 in PLWH with CD4 T-cell count ≥ 500 cells/mm3(high CD4 recovery, HCDR) were comparable to HC, but they were significantly decreased in PLWH with CD4 T-cell count < 500/mm3 (low CD4 recovery, LCDR). After adjusting for age, gender, viral suppression, and number of preexisting comorbidities, CD4 T-cell counts < 500/mm3 significantly predicted a poor magnitude of neutralizing antibodies against WT, omicron BA.5, and XBB 1.5 strains among PLWH. Multivariable linear regression adjusting for age and gender revealed that LCDR was associated with reduced neutralizing activity (P = 0.017) and interferon-γ-producing T-cell responses (P = 0.049 for CD T-cell; P = 0.014 for CD8 T-cell) against WT, and strongly associated with more decreased cross-neutralization against omicron BA.5 strains (P < 0.001).
Conclusion
HCDR demonstrated robust humoral and cell-mediated immune responses after a booster dose of ancestral SARS-CoV-2 vaccine, whereas LCDR showed diminished immune responses against WT virus and more impaired cross-neutralization against omicron BA.5 strain.
9.Clinical practice in office hysteroscopy
Namkung JEONG ; Angela CHO ; Yu-Jin KOO ; Jun-Woo AHN ; Hyuntae PARK ; Eun Sil LEE ; Sang Wook YI ; Won Duk JOO ; Sang-Hoon LEE ; Jae Kwan LEE ; Sa Ra LEE ;
Obstetrics & Gynecology Science 2025;68(3):175-185
Hysteroscopy is particularly valuable for the diagnosis of uterine cavity abnormalities through direct visualization. The development of office hysteroscopy has expanded the range of diagnostic and surgical procedures available. These detailed guidelines include patient counseling and the selection and setting of office hysteroscopy, including room, equipment, and medical staff. Analgesia or local anesthesia is often required in selective office hysteroscopy cases. Cervical dilation and preparation using medical or mechanical methods are required for most diagnostic hysteroscopic procedures. Methods for optimizing visualization and choosing suitable distension media are important for a successful office hysteroscopy. It is crucial to adhere to guidelines to prevent complications, such as vasovagal syncope, cervical trauma, uterine perforation, fluid overload, and embolism. Vaginoscopy can be a good alternative option for alleviating pain, especially in cases where the insertion of a vaginal speculum is expected to be challenging.
10.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.

Result Analysis
Print
Save
E-mail