1.Versatile, low-cost ophthalmic wet lab device to improve diagnostic and surgical eye training
Umar Mardianto ; Andi Arus Victor ; Prasandhya Astagiri Yusuf ; Vetnizah Juniantito ; Aria Kekalih ; Tri Rahayu ; Alhadi Bustamam ; Lukman Edwar
Medical Journal of Indonesia 2026;35(1):76-80
Ophthalmologists rely on wet lab training for both diagnostic procedures and surgical techniques. Existing wet lab devices are limited to surgical training and lack functionality for performing required perioperative diagnostic examinations. This study aimed to develop an affordable, easily manufactured eye holder to enhance ophthalmology training for wet lab simulations. A three-dimensional (3D)-printed animal eye holder was designed in 3D with a funnel-shaped structure resembling an orbital eye socket. The design was optimized for optimal wet lab activities. The animal eye holder device demonstrated potential use for ultrasound biometry, handheld keratometry, tonometry, and ophthalmological surgical training. These activities can be performed effectively after the animals’ eyes are stabilized inside the holder in flat and inclined positions. This innovative animal eye holder is the first designed to provide flexible diagnostic practice and surgical training, especially during wet lab activities.
3D printing
;
cataract
;
device
;
glaucoma
;
ophthalmologic surgical procedures
2.Design of a novel, modular, mouth retractor: A concept testing study
Miguel Sandino O. Aljibe ; Airene Maria C. Apacible ; Philip B. Fullante
Acta Medica Philippina 2025;59(Early Access 2025):1-10
BACKGROUND AND OBJECTIVES
Mouth retractors are essential in ensuring efficient yet safe exposure of the oral cavity and oropharynx. However, when applied improperly or haphazardly, retractors can cause tissue injuries and compromise patient safety. In addition, there are gaps in the usability of existing designs. This study aimed to identify the issues encountered by otorhinolaryngology surgeons in the use of commercially available mouth retractors, design and fabricate an improved retractor, and explore the use of additive manufacturing (popularly known as 3D printing) for retractor prototyping.
METHODSThe study used the United States Food and Drug Administration (US FDA) Design Control as its framework. End-user requirements from otorhinolaryngologists were collected through key informant interviews. Results were organized into a Design Input template which was used to guide the design and development process. Prototype designs were iteratively created using computer-aided design software and 3D printing. Once design specifications were satisfied, a beta prototype was fabricated and given to another cohort of otorhinolaryngologists. The participants assessed the usability of the beta prototype. System Usability Scale (SUS) was used to quantify participant's feedback.
RESULTSFive designs were created in the course of the study. The final prototype was fabricated using a Stereolithography (SLA) 3D printer. Several features were developed to address user requirements. The primary modification was to make the retractor modular to facilitate easier and shorter mounting and assembly. Gingival injury was addressed with the replacement of the maxillary alveolus hook with support bars. Five participants evaluated the beta prototype which received a mean SUS score of 75, well above the 50th percentile threshold.
CONCLUSIONThis study demonstrates the applicability of the US FDA Design Control Process in the local setting to improve the mouth retractor design. Clinical and ergonomic issues were identified and design solutions were proposed and some have been implemented in a low-fidelity prototype. Results of the small-scale usability test suggest that the present form factor can be the basis for further iterations. Future studies can implement the proposed features to address other clinical and ergonomic needs.
Human ; 3d Printing ; Printing, Three-dimensional ; Devices, Medical ; Equipment And Supplies
3.Three-dimentional printed personalized guide plate-assisted wrist arthroscopic repair of Palmer type ⅠB triangular fibrocartilage complex injury.
Jin LI ; Zhaoming ZHANG ; Lilian ZHAO ; Lilei HE ; Changbing WANG ; Yanjin LI ; Ting XU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1409-1413
OBJECTIVE:
To investigate the effectiveness of three-dimentional (3D) printed personalized guide plate-assisted wrist arthroscopic repair for Palmer type ⅠB triangular fibrocartilage complex (TFCC) injury.
METHODS:
A retrospective analysis was conducted on the clinical data of 20 patients with Palmer type ⅠB TFCC injuries admitted between January 2023 and March 2024 who met the selection criteria. Among them, 13 were male and 7 were female; ages ranged from 23 to 35 years, with a mean age of 30.3 years. All patients had a history of trauma, 12 cases involved falls and 8 cases involved sprains. All patients demonstrated a positive "piano key sign". MRI revealed deep ulnar-side tears of the TFCC. Conservative treatment for 6 weeks yielded poor or no clinical improvement. The interval from injury to surgery ranged from 2 to 9 months, with a mean of 5.0 months. Patients underwent wrist arthroscopic repair assisted by 3D printed personalized guide plate. Functional recovery was assessed preoperatively and postoperatively using the visual analogue scale (VAS) score for pain, modified Mayo wrist score, and range of motion (ROM) measurements for wrist flexion-extension, ulnar-radial deviation, and pronation-supination. At last follow-up, MRI was performed to evaluate the healing of TFCC.
RESULTS:
All 20 patients underwent successful surgery without complications such as vascular or nerve injury, fracture, incisional infection, or joint stiffness. All patients were followed up 9-18 months (mean, 12.4 months). At last follow-up, patients demonstrated significant improvements in VAS scores, modified Mayo wrist scores, wrist flexion-extension ROM, ulnar-radial deviation ROM, and pronation-supination ROM compared to preoperative levels ( P<0.05). MRI at last follow-up showed preserved TFCC continuity, excellent healing, and secure fixation.
CONCLUSION
3D-printed personalized guide plate significantly improve outcomes in wrist arthroscopic TFCC repair for Palmer type ⅠB injuries. They enable high-quality suturing, facilitate anatomical reconstruction, and markedly enhance wrist function.
Humans
;
Arthroscopy/methods*
;
Male
;
Adult
;
Triangular Fibrocartilage/diagnostic imaging*
;
Female
;
Retrospective Studies
;
Printing, Three-Dimensional
;
Wrist Injuries/diagnostic imaging*
;
Young Adult
;
Bone Plates
;
Treatment Outcome
;
Wrist Joint/surgery*
;
Magnetic Resonance Imaging
;
Range of Motion, Articular
4.Effectiveness evaluation of three-dimensional printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumor.
Yuhui SU ; Chao GAO ; Huajian WU ; Zhengwang SUN ; Wangjun YAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1414-1420
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D) printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumors.
METHODS:
A retrospective analysis was conducted on 26 patients with massive pelvic tumors who met the selection criteria and were treated between November 2021 and May 2024. The cohort included 11 males and 15 females, with a mean age of 52.65 years (range, 17-73 years). Histopathological diagnoses were as follows: 9 cases of chondrosarcoma, 2 of undifferentiated pleomorphic sarcoma, 4 of spindle cell sarcoma, 2 of osteosarcoma, 1 of solitary fibrous tumor, 1 of myxoid chondroma, 1 of malignant peripheral nerve sheath tumor, 1 of chondromyxoid epithelioma, and 5 of metastatic malignant tumors. According to the Enneking classification, tumor involvement was distributed as 4 cases in zones Ⅰ+Ⅱ, 9 in zones Ⅱ+Ⅲ, 3 in zones Ⅰ+Ⅳ, 8 in zones Ⅰ+Ⅱ+Ⅲ, and 2 in zones Ⅰ+Ⅱ+Ⅳ. The disease duration ranged from 3 to 40 months, with a mean of 9.85 months. All patients underwent reconstruction with customized 3D-printed hemi-pelvic prostheses. The effectiveness was evaluated by Musculoskeletal Tumor Society (MSTS) score and Harris hip score before operation and at last follow-up, and pain levels were evaluated by visual analogue scale (VAS) score before operation, at 3 months after operation, and at last follow-up.
RESULTS:
The operation time ranged from 186 to 528 minutes, with a mean of 334.58 minutes. The intraoperative blood loss ranged from 1 400 to 4 000 mL, with a mean of 2173.08 mL, and the transfusion volume ranged from 750 to 3 500 mL, with a mean of 1 659.62 mL. All 26 patients were followed up 10-42 months (mean, 18.5 months). Postoperative complications included prosthetic dislocation in 2 cases, which were attributed to improper positioning during home care and an accidental fall, respectively. One patient developed a vesicocutaneous fistula and poor wound healing due to pre-existing tumor invasion into the bladder. One patient experienced failure and loosening of the internal fixation at 8 months after operation caused by local tumor recurrence, and subsequently died at 14 months postoperatively due to progression of brain metastases. Postoperative complications such as poor healing of incisions, prosthetic dislocation, or failure of internal fixation was not observed in the remaining patients. At last follow-up, the walking ability of most patients recovered to varying degrees. The VAS scores at 3 months and at last follow-up significantly improved when compared with those before operation, and the scores at last follow-up further improved when compared with 3 months after operation, all showing significant differences ( P<0.05). The MSTS scores and Harris scores at last follow-up were significantly higher than those before operation ( P<0.05).
CONCLUSION
3D printed customized hemi-pelvic prosthesis is effective for reconstruction of massive pelvic tumors after resection, but there are still some limitations, and soft tissue reconstruction should be paid attention to.
Humans
;
Printing, Three-Dimensional
;
Female
;
Male
;
Adult
;
Plastic Surgery Procedures/methods*
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Pelvic Bones/surgery*
;
Bone Neoplasms/surgery*
;
Adolescent
;
Pelvic Neoplasms/surgery*
;
Prosthesis Design
;
Young Adult
;
Treatment Outcome
;
Prostheses and Implants
5.Effectiveness of three-dimensional printing-assisted vascularized fibular graft for repairing metatarsal defects.
Rong ZHOU ; Jihui JU ; Liang YANG ; Liping GUO ; Yucheng LIU ; Chao GENG ; Zhongzheng LIU ; Zefeng NIU ; Shuai DONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1447-1451
OBJECITVE:
To investigate the effectiveness of three-dimensional (3D) printing-assisted vascularized fibular graft for repairing metatarsal defects.
METHODS:
Between November 2021 and February 2024, 11 patients with varying degrees of metatarsal defects caused by trauma were treated. There were 10 males and 1 female, aged 22-67 years, with a mean age of 51.2 years. The defect locations were as follows: the first metatarsal in 4 cases, the fifth metatarsal in 2 cases, the first and the second metatarsals in 1 case, the first to third metatarsals in 1 case, the third and the fourth metatarsals in 1 case, the third to fifth metatarsals in 1 case, and the first to fifth metatarsals in 1 case. The preoperative American Orthopaedic Foot & Ankle Society (AOFAS) score was 67.0 (48.5, 72.5). Based on 3D-printed bilateral feet models and mirrored healthy-side foot arch angles for preoperative planning and design, the vascularized fibular graft was performed to repair the metatarsal defects. At last follow-up, the medial and lateral longitudinal arches of bilateral feet were measured on weight-bearing X-ray films, and functional assessment was conducted using the AOFAS score.
RESULTS:
All operations were successfully completed, with an operation time ranging from 180 to 465 minutes (mean, 246.8 minutes). All incisions healed by first intention, with no occurrence of osteomyelitis. All patients were followed up 6-22 months (mean, 10 months). X-ray film reviews showed bone graft healing in all cases, with a healing time of 3-6 months (mean, 5 months). All patients underwent internal fixator removal at 6-12 months after operation. At last follow-up, no significant difference was observed in the medial and lateral longitudinal arches between the healthy and affected feet ( P>0.05). The AOFAS score of the affected foot was 78.0 (73.5, 84.0), showing a significant improvement compared to the preoperative score ( P<0.05). The effectiveness was rated as excellent in 1 case, good in 7 cases, fair in 2 cases, and poor in 1 case. Linear scarring remained at the donor site, with no functional impairment in adjacent joint movement.
CONCLUSION
3D printing-assisted vascularized fibular graft for repairing metatarsal defects can effectively restore the physiological angle of the foot arch, facilitate the recovery of weight-bearing alignment, promote good bone healing, and yield satisfactory clinical outcomes.
Humans
;
Printing, Three-Dimensional
;
Middle Aged
;
Male
;
Fibula/blood supply*
;
Female
;
Metatarsal Bones/injuries*
;
Adult
;
Bone Transplantation/methods*
;
Aged
;
Plastic Surgery Procedures/methods*
;
Young Adult
;
Treatment Outcome
6.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
7.Key role of biomechanical properties and material selection in rotator cuff repair.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1606-1614
OBJECTIVE:
To summarize the biomechanical research progress of biomaterials in rotator cuff injury repair and to explore how biomaterials can restore the native histological and mechanical properties of the rotator cuff.
METHODS:
The relevant literature at home and abroad was widely reviewed to analyze the biomechanical properties of synthetic biomaterials, naturally derived biomaterials, and tissue grafts in the repair of rotator cuff injuries.
RESULTS:
Synthetic biomaterials [such as poly (lactic-co-glycolic acid) and polycaprolactone] can provide initial stable mechanical support due to their adjustable mechanical properties and degradation characteristics, while naturally derived biomaterials (such as collagen and hyaluronic acid) can promote cell adhesion and tissue integration due to their biocompatibility and bioactivity. Tissue grafts exhibit significant clinical utility by providing immediate mechanical stability and promoting tendon-to-bone healing. Three-dimensional bioprinting technology provides new possibilities for personalized repair of rotator cuff injuries by precisely controlling the spatial distribution and mechanical properties of biomaterials.
CONCLUSION
Future studies should further optimize the design of bioprinting materials, cell sources, and scaffolds to achieve better mechanical properties and clinical efficacy of biomaterials in the repair of rotator cuff injuries.
Humans
;
Rotator Cuff Injuries
;
Biocompatible Materials/chemistry*
;
Biomechanical Phenomena
;
Tissue Scaffolds
;
Rotator Cuff/surgery*
;
Tissue Engineering/methods*
;
Polyesters
;
Polyglycolic Acid/chemistry*
;
Hyaluronic Acid/chemistry*
;
Collagen/chemistry*
;
Lactic Acid/chemistry*
;
Polylactic Acid-Polyglycolic Acid Copolymer
;
Bioprinting
;
Wound Healing
;
Printing, Three-Dimensional
;
Tendon Injuries/surgery*
8.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
9.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
10.Digital study of IdebergⅡregional pelvic fracture anatomical plate based on 3D metal printing technology.
Yi ZHANG ; Jia-Kai ZHANG ; Jun-Long WU ; Yi ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(3):293-297
OBJECTIVE:
To establish digital model of Ideberg typeⅡregional glenoid fracture anatomical plate with 3D metal printing technology.
METHODS:
The scapular imaging data of a 34-year-old healthy male volunteer were retrospectively selected. Mimics 15.01, NX 12.0 and other software were used to design Ideberg typeⅡ regional scapular fracture guide plate system. STL data were input into a metal 3D printer to print 1∶1 scapular model and anatomical plate of scapular pelvis with guide sleeve. The fit of the plate was tested in vitro and the accuracy of the screw position was evaluated by imaging. The printing time of scapular model, design of the nail path and making time of the anatomic guided plate were recorded.
RESULTS:
3D metal-printed Ideberg typeⅡ guide plate for scapular fracture fitted well to 3D printed scapular model, the locking screw was oriented accurately, and X-ray and CT showed good screw position. The printing time of scapula model, time of nail path design and special-shaped anatomical guide plate production were 52.0, 15.0 and 320 min, respectively.
CONCLUSION
Anatomical plates based on 3D metal printing technology could achieve good adhesion of Ideberg typeⅡ regional fractures and precise screw placement, providing a new and accurate surgical method for the treatment of Ideberg typeⅡ glenoid fractures.
Humans
;
Printing, Three-Dimensional
;
Male
;
Adult
;
Bone Plates
;
Fractures, Bone/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Pelvic Bones/surgery*
;
Metals
;
Scapula/surgery*
;
Models, Anatomic


Result Analysis
Print