1.Clinical Application of Multimodal MRI in Cognitive Impairment Associated with Cerebral Small Vessel Disease
Hong XU ; Mao-hua HUANG ; Quan-zhi ZHAO ; Meng-pan HUANG ; Bao LIAO
Progress in Modern Biomedicine 2025;25(17):2820-2826
Objective:To explore the clinical application value of multimodal Magnetic Resonance Imaging(MRI)in cognitive impairment related to Cerebral Small Vessel Disease(CSVD).Methods:This study was a retrospective analysis of 60 CSVD patients,who were divided into cognitive impairment group(n=32)and normal group(n=28)based on Montreal Cognitive Assessment scale(MoCA).Compare the general information and MRI parameters of two groups of patients,use correlation analysis and logistic regression analysis to investigate the relationship between MRI parameters and cognitive dysfunction,and use receiver operating characteristic curve(ROC)to explore the value of MRI parameters in diagnosing cognitive dysfunction in cerebral small vessel disease.Results:Compared with the cognitively normal group,the cognitive impairment group had older age,higher apparent diffusion coefficient(ADC),lower anisotropy score(FA),and an overall increase in microbleeds(P<0.05).Age(r=-0.510),ADC value(r=-0.591),and overall number of microbleeds(r=-0.369)were significantly negatively correlated with MoCA score(P<0.05),while FA value(r=0.262)was significantly positively correlated with MoCA score(P<0.05).The logistic regression results indicate that age,overall microbleeds,ADC value,and FA value are influencing factors for cognitive impairment in patients with cerebral small vessel disease.ROC curve analysis showed that the combination of age,ADC,FA,and microbleeds significantly improved diagnostic efficacy(AUC=0.990,95%CI=0.974-1.000).Conclusion:The joint analysis of multimodal MRI parameters can provide important imaging evidence for the early identification of cognitive dysfunction in CSVD.
2.Clinical Application of Multimodal MRI in Cognitive Impairment Associated with Cerebral Small Vessel Disease
Hong XU ; Mao-hua HUANG ; Quan-zhi ZHAO ; Meng-pan HUANG ; Bao LIAO
Progress in Modern Biomedicine 2025;25(17):2820-2826
Objective:To explore the clinical application value of multimodal Magnetic Resonance Imaging(MRI)in cognitive impairment related to Cerebral Small Vessel Disease(CSVD).Methods:This study was a retrospective analysis of 60 CSVD patients,who were divided into cognitive impairment group(n=32)and normal group(n=28)based on Montreal Cognitive Assessment scale(MoCA).Compare the general information and MRI parameters of two groups of patients,use correlation analysis and logistic regression analysis to investigate the relationship between MRI parameters and cognitive dysfunction,and use receiver operating characteristic curve(ROC)to explore the value of MRI parameters in diagnosing cognitive dysfunction in cerebral small vessel disease.Results:Compared with the cognitively normal group,the cognitive impairment group had older age,higher apparent diffusion coefficient(ADC),lower anisotropy score(FA),and an overall increase in microbleeds(P<0.05).Age(r=-0.510),ADC value(r=-0.591),and overall number of microbleeds(r=-0.369)were significantly negatively correlated with MoCA score(P<0.05),while FA value(r=0.262)was significantly positively correlated with MoCA score(P<0.05).The logistic regression results indicate that age,overall microbleeds,ADC value,and FA value are influencing factors for cognitive impairment in patients with cerebral small vessel disease.ROC curve analysis showed that the combination of age,ADC,FA,and microbleeds significantly improved diagnostic efficacy(AUC=0.990,95%CI=0.974-1.000).Conclusion:The joint analysis of multimodal MRI parameters can provide important imaging evidence for the early identification of cognitive dysfunction in CSVD.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Histaminergic Innervation of the Ventral Anterior Thalamic Nucleus Alleviates Motor Deficits in a 6-OHDA-Induced Rat Model of Parkinson's Disease.
Han-Ting XU ; Xiao-Ya XI ; Shuang ZHOU ; Yun-Yong XIE ; Zhi-San CUI ; Bei-Bei ZHANG ; Shu-Tao XIE ; Hong-Zhao LI ; Qi-Peng ZHANG ; Yang PAN ; Xiao-Yang ZHANG ; Jing-Ning ZHU
Neuroscience Bulletin 2025;41(4):551-568
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown. Here, we assessed the contribution of histamine to VA neuronal activity and PD motor deficits. Functional magnetic resonance imaging showed reduced VA activity in PD patients. Optogenetic activation of VA neurons or histaminergic afferents significantly alleviated motor deficits in 6-OHDA-induced PD rats. Furthermore, histamine excited VA neurons via H1 and H2 receptors and their coupled hyperpolarization-activated cyclic nucleotide-gated channels, inward-rectifier K+ channels, or Ca2+-activated K+ channels. These results demonstrate that histaminergic afferents actively compensate for Parkinsonian motor deficits by biasing VA activity. These findings suggest that targeting VA histamine receptors and downstream ion channels may be a potential therapeutic strategy for PD motor dysfunction.
Animals
;
Histamine/metabolism*
;
Male
;
Oxidopamine/toxicity*
;
Rats
;
Ventral Thalamic Nuclei/physiopathology*
;
Rats, Sprague-Dawley
;
Disease Models, Animal
;
Parkinson Disease/metabolism*
;
Neurons/physiology*
;
Humans
;
Optogenetics
5.Expert consensus on management of instrument separation in root canal therapy.
Yi FAN ; Yuan GAO ; Xiangzhu WANG ; Bing FAN ; Zhi CHEN ; Qing YU ; Ming XUE ; Xiaoyan WANG ; Zhengwei HUANG ; Deqin YANG ; Zhengmei LIN ; Yihuai PAN ; Jin ZHAO ; Jinhua YU ; Zhuo CHEN ; Sijing XIE ; He YUAN ; Kehua QUE ; Shuang PAN ; Xiaojing HUANG ; Jun LUO ; Xiuping MENG ; Jin ZHANG ; Yi DU ; Lei ZHANG ; Hong LI ; Wenxia CHEN ; Jiayuan WU ; Xin XU ; Jing ZOU ; Jiyao LI ; Dingming HUANG ; Lei CHENG ; Tiemei WANG ; Benxiang HOU ; Xuedong ZHOU
International Journal of Oral Science 2025;17(1):46-46
Instrument separation is a critical complication during root canal therapy, impacting treatment success and long-term tooth preservation. The etiology of instrument separation is multifactorial, involving the intricate anatomy of the root canal system, instrument-related factors, and instrumentation techniques. Instrument separation can hinder thorough cleaning, shaping, and obturation of the root canal, posing challenges to successful treatment outcomes. Although retrieval of separated instrument is often feasible, it carries risks including perforation, excessive removal of tooth structure and root fractures. Effective management of separated instruments requires a comprehensive understanding of the contributing factors, meticulous preoperative assessment, and precise evaluation of the retrieval difficulty. The application of appropriate retrieval techniques is essential to minimize complications and optimize clinical outcomes. The current manuscript provides a framework for understanding the causes, risk factors, and clinical management principles of instrument separation. By integrating effective strategies, endodontists can enhance decision-making, improve endodontic treatment success and ensure the preservation of natural dentition.
Humans
;
Root Canal Therapy/adverse effects*
;
Consensus
;
Root Canal Preparation/adverse effects*
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Expert consensus on surgical treatment and rehabilitation for competitive sports athletes returning to sports after anterior cruciate ligament injury (version 2025)
Kai HUANG ; Lunhao BAI ; Qing BI ; Hong CHEN ; Jiwu CHEN ; Xuesong DAI ; Wenyong FEI ; Weili FU ; Zhizeng GAO ; Lin GUO ; Yinghui HUA ; Jingmin HUANG ; Suizhu HUANG ; Xuan HUANG ; Jian LI ; Qiang LI ; Shuzhen LI ; Yanlin LI ; Yunxia LI ; Zhong LI ; Ning LIU ; Yuqiang LIU ; Wei LU ; Hongbin LYU ; Haile PAN ; Xiaoyun PAN ; Chao QI ; Weiliang SHEN ; Luning SUN ; Jin TANG ; Zimin WANG ; Bide WANG ; Ru WANG ; Shaobai WANG ; Licheng WEI ; Weidong XU ; Yongsheng XU ; Jizhou YANG ; Liang YANG ; Rui YANG ; Hongbo YOU ; Tengbo YU ; Jiakuo YU ; Bing YUE ; Hua ZHANG ; Hui ZHANG ; Qingsong ZHANG ; Xintao ZHANG ; Jiajun ZHAO ; Lilian ZHAO ; Qichun ZHAO ; Song ZHAO ; Jiapeng ZHENG ; Jiang ZHENG ; Zhi ZHENG ; Jingbin ZHOU ; Jinzhong ZHAO
Chinese Journal of Trauma 2025;41(4):325-338
With the rapid development of competitive sports, the incidence of anterior cruciate ligament (ACL) injury is on the rise. Such injuries may shorten athletes′ career and lead to other long-term adverse consequences. Although athletes generally recover well after ACL reconstruction, many still struggle to return to their pre-injury performance levels. Advances in the understanding of ACL anatomy and injury mechanisms, along with the evolution of surgical techniques and rehabilitation methods, have provided more individualized and tailored options for athletes following ACL injuries. However, there is currently no consensus in China regarding surgical and rehabilitation strategies for competitive athletes aiming to return to sports after ACL injuries. To this end, the Sports Medicine Committee of the Chinese Research Hospital Association and the Editorial Board of the Chinese Journal of Trauma jointly formulated the Expert consensus on surgical treatment and rehabilitation for competitive sports athletes returning to sports after anterior cruciate ligament injury ( version 2025), and presented 14 recommendations covering surgical indications, preoperative rehabilitation, surgical timing, surgical strategies and postoperative rehabilitation strategies, aiming to improve the surgical treatment and rehabilitation system for ACL injuries in competitive athletes and facilitate their return to high-level sports performance after injury.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail